Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

Assessment of DRL for Computed Tomography in Local Hospital (지역병원에서의 전산화단층촬영 검사에 대한 DRL 평가)

  • Choi, Seok-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.619-625
    • /
    • 2022
  • In the field of imaging medicine, computed tomography is one of the most common test methods and one of the most frequently used test methods in hospitals. However, it is accompanied by a very high radiation exposure compared to other test methods. In order to reduce exposure, CT scans should be performed only when absolutely necessary, and even if the tests are performed because they are absolutely necessary, a protocol that serves the purpose of the test and allows the test to be performed in a small dose should be used. In this study, we wanted to learn about the most up-to-date radiation dose usage information used by the region's leading general hospitals and develop a diagnostic reference level (DRL). In the experimental results, the Head CT and Abdomen CT tests showed that DLP was higher than the NRPB (U.K) and Korean DRL. The DLP values used by Chest CT were low for all 3 types of CT devices. The hospital found that efforts to reduce exposure should be made during CT examinations, and in particular, Head CT and Abdomen CT determined that efforts to reduce exposure were necessary.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

Dose Reduction and Image Quality Assessment of the CareDose 4D Technique on Abdomen Liver Computed Tomography (복부 간 CT 검사에서 CareDose 4D 사용에 따른 선량 감소 및 화질 평가)

  • Seok, Jong-Min;Jeon, Woo-Jin;Park, Young-Joon;Lee, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • The purpose of this study was to evaluate the clinical efficacy of 128 MDCT (multi-detector computed tomography) for reducing the CareDose 4D dose and comparing the image quality with the fixed tube current technique. For this purpose, we conducted the phantom and clinical studies to evaluate the exposure dose and image of the subject before and after applying the CareDose 4D system in abdominal examination using 128 MDCT. In the phantom study, ROI (Region of interest) was located at the center, 3, 6, 9, 12 o'clock, into two groups: group A without CareDose 4D and Group B applied were measured. In the clinical study, ROI was located at the liver 8 segments, divided into two groups too. The measured items were CT number, noise, and dose length product (DLP) dose. The result of CTDIvol (CT Dose Index volume) measurements in phantom and clinical studies were lower than those before CareDose 4D application, and dose and effective dose were also measured lower (p<.05). There was no difference in CT number before and after application (p>.05). In conclusion, using CareDose 4D, we can obtain optimal image information without deteriorating image quality while reducing patient dose.

3-D Radiosurgery Planning Using Personal Computer (Personal Computer를 이용한 3차원적 뇌정위적 방사선 치료계획)

  • 서태석;서덕영;박찬일;하성환;강위생
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.63-69
    • /
    • 1992
  • Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on three steps. The first step is to input the image information of the patient obtained from CT or MR scan into personal computer through on-line or digitizer. The position and shape of target are also transferred into computer using Angio or CT localization. The second step is to compute dose distribution on image plane, which is transformed into stereotactic frame coordinate. and to optimize dose distribution through the selection of optimal treatment parameters. The third step is to display both isodose distribution and patient image simultaneously using superimpose technique. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modelities such as angio, CT and MRI. It is also possible to develop 3-D planning system in radiation therapy using beam's eye view or CT simulation in future.

  • PDF

Findings on Chest Low-Dose CT Images of Group Exposed to Inorganic Dusts (분진에 노출되었던 집단의 흉부 저선량 CT영상 소견)

  • Lee, Won-Jeong;Seon, Jong-Ryul;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.305-314
    • /
    • 2011
  • The purpose of this study was to compare the findings on the chest low-dose CT (LDCT) images between the negative and positive groups for pneumoconiosis in the group exposed to inorganic dust. From May 30, 2007 to August 31, 2008, total 328 subjects were examined by a LDCT. LDCT images were read by a chest radiologist who has much experience for reading of pneumoconiosis. All subjects were classified into two groups based on digital images after consensus reading of two radiologists according to the ILO 2000 guidelines; negative group (87, 26.5%) without pneumoconiosis and positive group (241, 73.5%). Statistical analysis was performed using a SPSS 14.0. There were significant differences in age (60.9 vs. 65.0, p<0.001), and in dust expose duration (17.0 vs. 19.2, p=0.024) between two groups, but no significant difference in smoking (p=0.784). Of the 328 subjects, 13 diagnosis were extracted from 245 subjects (74.7%). Coronary artery calcification (CAC) was significantly higher in positive group than that in negative group (36.9% vs. 25.3%, p=0.049). Honeycombing showed higher frequency in positive group than in negative group (6.2% vs. 1.2%, p=0.079). Pneumoconiosis findings caused by inorganic dusts exposure showed the significant relation with CAC on LDCT images. Future studies need to prove that pneumoconiosis finding is independent risk factor for CAC using a coronary artery angiography.

Dose and Image Evaluation of Pediatric Head Image according to CT Scan Mode and kVp Changes (CT Scan Mode와 관전압 변경에 따른 소아 두부 영상의 선량 및 영상평가)

  • Byeong-Je Kim;Dong-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.801-808
    • /
    • 2023
  • In order to minimize radiation exposure and secure diagnostic value images during CT examination of the head of children, the usefulness of volume axial mode is evaluated through comparison and analysis of exposure dose and images of volume axial mode, high pitch mode, and helical mode. Image evaluation and dose evaluation were performed in CT high pitch mode, helical mode, and volume axial mode for infants under the age of 1 according to the voltages of 70, 80, and 100 kVp tubes. The image evaluation was conducted by comparing image quality by setting ROI for each image, calculating SNR and CNR, using ONE-WAY (ANOVA) to evaluated statistical significance, and cross-examining the dose evaluation using DLP values displayed in the Dose Report. When inspected using volume axial mode, DLP values were generally low, and SNR and CNR values differed by ROI and kVp. When volume axial mode evaluated the quality of the image compared to other scan modes, the difference is not uniform. For the reason, certain modes are not considered excellent, but the exposure dose was reduced the most in terms of dose. In addition, the point that the volume axial mode can be examined at its original location, short scanning time and needless of table movement is useful for CT tests for children under 1 year of age with high radiation sensitivity.

Dose Reduction Method for Chest CT using a Combination of Examination Condition Control and Iterative Reconstruction (검사 조건 제어와 반복 재구성의 조합을 이용한 흉부 CT의 선량 저감화 방안)

  • Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1025-1031
    • /
    • 2023
  • We aimed to evaluate the radiation dose and image quality by changing the Scout view voltage in low-dose chest CT (LDCT) and applying scan parameters such as AEC (auto exposure control) and ASIR (adaptive statistical iterative reconstruction) to find the optimal protocol. Scout view voltage was varied at 80, 100, 120, 140 kV and after measuring the dose 5 times using the existing low-dose chest CT protocol, the appropriate kV was selected for the study using the Dose report provided by the equipment. After taking a basic LDCT shot at 120 kV, 30 mAs, ASIR 50% was applied to this condition. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed by measuring Background noise (B/N). For dose comparison, CTDIvol and DLP provided by the equipment were compared and analyzed using the formulas. The results indicated that the protocol of scout 140 + LDCT + ASIR 50 + AEC reduced radiation exposure and improved image quality compared to traditional LDCT, providing an optimal protocol. As demonstrated in the experiment, LDCT screenings for asymptomatic normal individuals are crucial, as they involve concerns over excessive radiation exposure per examination. Therefore, applying appropriate parameters is important, and it is expected to contribute positively to the public health in future LDCT based health screenings.