• 제목/요약/키워드: CPR feedback device

검색결과 7건 처리시간 0.025초

Study of military CPR quality and education by feedback device and debriefing

  • Moon, Soo-Jae;Kim, Seon-Rye;Cho, Byung-Jun
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권9호
    • /
    • pp.107-112
    • /
    • 2016
  • In this paper, we propose the effects of military cardiopulmonary resuscitation(CPR) on the quality of debriefing and feedback device training. The key idea of combination debriefing and feedback device training is to maximize effects of CPR. The participants of the research were non-medic soldiers in ROK army, and had not undergone any professional CPR training before. Each group of soldier was randomized to perform of military CPR by using training method in each group. After 5 minutes of performing CPR, each D, F, DF group showed significant improvement in CPR performance. When comparing each group, the rate of success in CPR performance in DF group was significantly higher than that of F group with the average difference of 11.160(p<.01) points. In summation, the training programs that DF received seemed to be more efficient and effective than that of D and F. The fatigue level was evaluated by comparing the lactate concentration in blood after performing CPR. Through this experiment, we show that the training programs that DF received is more efficient and effective than that of D and F.

코로나19 의심 또는 확진 환자가 병원 밖 심정지 발생 시 구조자의 개인 보호장비(PPE) 착용에 의한 가슴압박 효과 비교 : 무작위 교차 시뮬레이션 연구 (Effect of level D personal protective equipment on chest compression for pre-hospital arrest patients with suspected or confirmed COVID-19 : A randomized crossover simulation trial)

  • 홍석환;양연수;한상균
    • 한국응급구조학회지
    • /
    • 제25권1호
    • /
    • pp.23-36
    • /
    • 2021
  • Purpose: The purpose of this study was to determine how the use of level D personal protective equipment (PPE) and cardiopulmonary resuscitation (CPR) feedback equipment affects chest compression (CC). Furthermore, this study provides basic data for developing Korean CPR guidelines that can be applied to patients with suspected or confirmed COVID-19. Methods: This randomized, single-blinded, crossover simulation trial included 26 student paramedics who performed 2-minute chest compressions using three different methods: Method A involved performing traditional CC for two minutes without donning level D PPE, Method B involved performing CC while donning level D PPE, and Method C involved performing CC with a CPR feedback device while donning level D PPE. Results: The use of a CPR feedback device during the 2-minute CC increased the exercise intensity of the subjects, but donning level D PPE didn't affect the quality of CC and the exercise intensity. The results of methods A and B showed changes in the quality of compression 80 seconds after the start of CC. No significant changes occurred in 2-minute CC when using the CPR feedback device. Conclusion: Using a CPR feedback device could prevent deterioration in the quality of CC while donning level D PPE.

성인 심폐소생술 술기 점수 비교: 레어달 애니 스킬리포터 대 액타 911 마네킹 (Comparison of adult CPR skill scores: Real-time visual feedback manikin(Resusci Anne SkillReporterTM) vs. Non-feedback manikin(Actar 911 SquadronTM))

  • 김지희;문태영;엄태환
    • 한국응급구조학회지
    • /
    • 제15권2호
    • /
    • pp.101-108
    • /
    • 2011
  • Purpose: Cardiopulmonary resuscitation (CPR) prevents tissue necrosis of the brain and cardiac muscle in the cardiac arrest patient and requires exact skills in order to increase survival rate. Through comparison of the training effects of feedback manikin and non-feedback manikin, this study present the effective CPR device to CPR instructors. Method: This CPR course for 80 students by using Resusci Anne $SkillReporter^{TM}$ (RASR; Laerdal Medical, Stavanger, Norway) and Actar 911 $Squadron^{TM}$ (A911; Vital Signs, New Jersey, USA) held on December 22, 2009. Thirty seven students and two assistants were placed in one laboratory, there were five RASR manikins which provide the LED performance indicator, not the metronome. Forty two students and two assistants were placed in the other laboratory, there were 20 A911 manikins which don't provide any feedback indicator. Chest compression scores and ventilation compression scores obtaining from two groups were analysed statistically by using independent t-test. Results: Chest compression scores, average depth (mm) was 37.5 in RASR and 41.80 A911 (p=.004), too depth (#) was 2.8 in RASR and 19.4 A911 (p=.005), average number per min (#/min) was 64.4 in RASR and 68.2 A911 (p=.038), wrong hand position (#/min) was 10.9 in RASR and 30.8 A911 (p=.040). Four items that showed better scores in group RASR had statistically significant difference. Ventilation compression scores, percent correct (%) was 40.6 in RASR and 20.6 A911 (p<.001), number correct (#) was 4.7 in RASR and 2.1 A911 (p=.002), too fast (#) was 0.9 in RASR and 2.9 A911 (p=.003), average volume (ml) was 536.5 in RASR and 707.1 A911 (p=.011). Also, three items that showed better scores in group RASR had statistically significant difference. Conclusions: Regarding the positive effect of CPR training feedback, comparison between the real-time visual feedback manikin (RASR) and the non-feedback manikin (A911) showed that RASR had better results than A911 in chest compression except average number per min (it means that we need harder chest manikin) and ventilation. Verification of the training effect in the real world such as CPR outcomes is also necessary. A proper application of manikin in training circumstances and research on retention of CPR skills will be needed.

이동용 영상촬영기기 바디캠을 활용한 팀단위 심폐소생술의 교육피드백 효과 (Training Feedback effect of team-based CPR using a mobile video recording device body camera)

  • 임성빈
    • 스마트미디어저널
    • /
    • 제13권5호
    • /
    • pp.62-71
    • /
    • 2024
  • 본 연구는 구급현장에서 사용되고 있는 바디캠을 활용하여 교육피드백 효과를 파악하고자 응급구조학과 4학년 32명을 대상으로 팀단위 심폐소생술 시뮬레이션을 진행하여 바디캠 피드백 전후에 대한 인식도, 교육피드백 효과, 만족도, 바디캠 기기활용 선호도 및 애로사항을 파악하였다. 자료분석은 SPSS 27.0 프로그램을 이용하여 기술통계, 빈도분석, paried t-test, Wilcoxon signed rank test를 수행하였다. 연구결과 바디캠 사용에 대한 인식은 3.73±0.62점에서 4.45±0.54점으로 긍정적인 인식변화를 보였으며, 3.98±0.51의 긍정적인 만족도는 나타냈다(p<.001). 또한 바디캠 피드백 후 자가점검 정확도와 수행능력점수에서 유의한 상승효과를 나타냈다(p<.001). 따라서 팀단위 시뮬레이션 소생술 훈련 시 강사의 직접적인 피드백 없이도 바디캠 영상시청을 통한 자가피드백을 수행하여 자가점검능력 향상 및 수행능력향상의 긍정적인 교육피드백 효과를 발휘할 수 있다.

단일주파수분석을 이용한 심폐소생술 흉부압박깊이 추정 (Estimation of Chest Compression Depth during Cardiopulmonary Resuscitation by using Single Frequency Analysis)

  • 유원상;강성민;최성욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권4호
    • /
    • pp.211-217
    • /
    • 2017
  • During the emergency situation such as cardiac arrest, cardiopulmonary resuscitation(CPR) is the most important treatment to maintain patient's blood circulation. Since the quality of CPR can not be easily measured or evaluated by the eye, an assistive device with an accelerometer can help to assess the pressure depth of CPR. In this study, we propose a single frequency analysis method to reduce the error of the accelerometer by extracting only one frequency component from the Fourier transform process. To verify the effectiveness of the single frequency analysis, acceleration data at CPR conditions were measured at a sampling rate of 50 / sec using a wristband equipped with an acceleration sensor. Then, We compared the existing distance estimation method and the single frequency analysis method using the measured data. The amplitude value proportional to the compression depth was obtained by applying the single frequency analysis method.

심폐소생술에서 두 개의 가속도 센서를 활용한 흉부 압박 깊이 추정 (Estimation of Chest Compression Depth using two Accelerometers during CPR)

  • 송영탁;오재훈;서영수;지영준
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권5호
    • /
    • pp.407-411
    • /
    • 2010
  • During the cardiopulmonary resuscitation (CPR), the correct chest compression depth and period are very important to increase the resuscitation possibility. For the feedback of chest compression depth, the depth monitoring device based on the accelerometer is developed and widely used. But this method tends to overestimate the compression depth on the bed. To overcome this limitation, the chest compression depth estimation method using two accelerometers is suggested With the additional accelerometer between the patient and mattress on the bed, the compression of the mattress is also measured and it is used to compensate the overestimation error. The experimental results show that the single accelerometer estimates as 61.4mm for the actual compression depth of 43.6mm on the mattress. The depth estimation with the dual accelerometer was 44.6mm which is close to the actual depth. With the automatic zeroing in every single compression, the integration error for the depth can be reduced. The dual accelerometer method is effective to increase the accuracy of the chest compression depth estimation.

확장현실 기반의 심폐소생술 교육 시스템의 사용성 평가 (Usability of CPR Training System based on Extended Reality)

  • 이영호;김선경;최종명;박건우;고영혜
    • 사물인터넷융복합논문지
    • /
    • 제8권6호
    • /
    • pp.115-122
    • /
    • 2022
  • 최근 병원 밖 심정지 환자의 생존율 향상을 위한 일반인 대상 심폐소생술 교육의 중요성이 강조되고 있다. 일반인 대상 효과적인 심폐소생술 교육을 위해 보다 정확하고 생동감 있는 교육전략이 필요하다. 이에 본 연구에서는 확장현실 기반의 심폐소생술 교육시스템을 개발하고 일반인을 대상으로 교육한 사용성 평가 결과를 제시한다. 3개의 응용프로그램으로 구성된 확장현실 기반 심폐소생술 교육시스템에서는 첫 번째 마네킹에 정합된 3D 심장 해부도를 스마트글라스에 전송하여 가슴압박 지점을 안내한다. 두 번째 응용프로그램은 스마트글라스를 통해 심폐소생술 과정에 대한 시·청각적 정보를 제공함과 동시에 스마트워치의 진동 알림을 전송하여 심폐소생술의 정확한 압박 속도를 안내한다. 세번째 Add on kit는 마네킹에 설치된 센서를 통하여 흉부 압박의 깊이와 속도에 대한 즉각적인 피드백 정보를 스마트폰으로 전송한다. 본 연구에 참여한 93명의 대상자는 확장현실 기반 심폐소생술 교육시스템이 현장감과 효과성 측면에서 긍정적이라 평가하였다. 확장현실 기술을 이용한 정합기술은 현장감과 몰입도를 높이고 자기 주도적 훈련을 쉽게 함으로서 심폐소생술 교육 운영 효율성 향상에 이바지할 수 있다.