• Title/Summary/Keyword: CM fusion

Search Result 207, Processing Time 0.025 seconds

Effect of the TiO2 Nanotubes in the Photoelectrode on Efficiency of Dye-sensitized Solar Cell

  • Rahman, Md. Mahbubur;Son, Hyun-Seok;Lim, Sung-Su;Chung, Kyung-Ho;Lee, Jae-Joon
    • Journal of Electrochemical Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.110-115
    • /
    • 2011
  • The effect of $TiO_2$ nanotube (TNT) and nanoparticle (TNP) composite photoelectrode and the role of TNT to enhance the photo conversion efficiency in dye-sensitized solar cell (DSSC) have investigated in this study. Results demonstrated that the increase of the TNT content (1-15 %) into the electron collecting TNP film increases the open-circuit potential ($V_{oc}$) and short circuit current density ($J_{sc}$). Based on the impedance analysis, the increased $V_{oc}$ was attributed to the suppressed recombination between electrode and electrolyte or dye. Photochemical analysis revealed that the increased Jsc with the increased TNT content was due to the scattering effect and the reduced electron diffusion path of TNT. The highest $J_{sc}$ (12.6 mA/$cm^2$), Voc (711 mV) and conversion efficiency (5.9%) were obtained in the composite photoelectrode with 15% TNT. However, $J_{sc}$ and $V_{oc}$ was decreased for the case of 20% TNT, which results from the significant reduction of adsorbed dye amount and the poor attachment of the film on the fluorine-doped tin oxide (FTO). Therefore, application of this composite photoelectrode is expected to be a promising approach to improve the energy conversion efficiency of DSSC.

Influence of Series Resistance and Interface State Density on Electrical Characteristics of Ru/Ni/n-GaN Schottky structure

  • Reddy, M. Siva Pratap;Kwon, Mi-Kyung;Kang, Hee-Sung;Kim, Dong-Seok;Lee, Jung-Hee;Reddy, V. Rajagopal;Jang, Ja-Soon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.5
    • /
    • pp.492-499
    • /
    • 2013
  • We have investigated the electrical properties of Ru/Ni/n-GaN Schottky structure using current-voltage (I-V) and capacitance-voltage (C-V) measurements at room temperature. The barrier height (${\Phi}_{bo}$) and ideality factor (n) of Ru/Ni/n-GaN Schottky structure are found to be 0.66 eV and 1.44, respectively. The ${\Phi}_{bo}$ and the series resistance ($R_S$) obtained from Cheung's method are compared with modified Norde's method, and it is seen that there is a good agreement with each other. The energy distribution of interface state density ($N_{SS}$) is determined from the I-V measurements by taking into account the bias dependence of the effective barrier height. Further, the interface state density $N_{SS}$ as determined by Terman's method is found to be $2.14{\times}10^{12}\;cm^{-2}\;eV^{-1}$ for the Ru/Ni/n-GaN diode. Results show that the interface state density and series resistance has a significant effect on the electrical characteristics of studied diode.

Polymethylmethacrylate-Augmented Screw Fixation for Stabilization of the Osteoporotic Spine : A Three-Year Follow-Up of 37 Patients

  • Moon, Bong-Ju;Cho, Bo-Young;Choi, Eun-Young;Zhang, Ho-Yeol
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.305-311
    • /
    • 2009
  • Objective : The purpose of this study was to determine the efficacy, radiological findings, clinical outcomes and complications in patients with lumbar stenosis and osteoporosis after the use of polymethylmethacrylate (PMMA) augmentation of a cannulated pedicle screw. Methods : Thirty-seven patients with degenerative spinal stenosis and osteoporosis (T-score < -2.5) underwent lumbar fusion using the Dream Technology Pedicle Screw ($DTPS^{TM}$, Dream Spine Total Solutions, Dream STS, Seoul. Korea) between 2005 and 2007. The clinical outcomes were evaluated by using the visual analog scale (VAS) and the Prolo scale. Radiologic findings were documented through computed tomography (CT) and plain films. Results : Thirty-seven patients were evaluated and included, 2 males and 35 females with an average bone mineral density (BMD) of $0.47g/cm^2$. The average age of the patients was 68.7 (range, 57-88). The preoperative VAS for low back and leg pain ($7.87{\pm}0.95$ and $8.82{\pm}0.83$) were higher as compared with postoperative VAS ($2.30{\pm}1.61$ and $1.42{\pm}0.73$) with statistical significance (p = 0.006, p = 0.003). According to the Prolo scale, 11, 22, one and three patients were in excellent, good, fair and poor conditions, respectively. The average amount of the injected cement per one cannulated screw was $1.83{\pm}0.11\;mL$. Conclusion : The results show favorable outcome both clinically and radiographically for 37 patients who underwent lumbar fusion using $DTPS^{TM}$ and PMMA. Based on the results, the use of this surgical method can be a safe and effective option for the operation on the osteoporotic spine.

Study on Electrical Conductivity, Transmittance and Gas Barrier Properties of DLC Thin Films (DLC 박막의 전기전도성, 투과율 및 가스베리어 특성에 관한 연구)

  • Park, S.B.;Kim, C.H.;Kim, T.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.4
    • /
    • pp.187-193
    • /
    • 2018
  • In this study, the electrical conductivity, transmittance and gas barrier properties of diamond-like carbon (DLC) thin films were studied. DLC is an insulator, and has transmittance and oxygen gas barrier properties varying depending on the thickness of the thin film. Recently, many researchers have been trying to apply DLC properties to specific industrial conditions. The DLC thin films were deposited by PECVD (Plasma Enhanced Chemical Vapor Deposition) process. The doping gas was used for the DLC film to have electrical conductivity, and the optimum conditions of transmittance and gas barrier properties were established by adjusting the gas ratio and DLC thickness. In order to improve the electrical conductivity of the DLC thin film, $N_2$ doping gas was used for $CH_4$ or $C_2H_2$ gas. Then, a heat treatment process was performed for 30 minutes in a box furnace set at $200^{\circ}C$. The lowest sheet resistance value of the DLC film was found to be $18.11k{\Omega}/cm^2$. On the other hand, the maximum transmittance of the DLC film deposited on the PET substrate was 98.8%, and the minimum oxygen transmission rate (OTR) of the DLC film of $C_2H_2$ gas was 0.83.

Surgical Treatment of Lumbosacral Stenosis Caused by Bacterial Discospondylitis in a Great Dane Dog

  • Yim, Hyeongjun;Kim, Jong-Hoon;Kim, Hyeonjo;Kim, Jieyoo;Lee, Si Eun;Lee, Hee Chun;Kim, Nahyun;Lee, Dongbin;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.38 no.1
    • /
    • pp.45-48
    • /
    • 2021
  • A 6-year-old, 26 kg spayed female Great Dane presented with back pain and hindlimb paresis. On neurological examination, severe pain was detected on the lumbosacral joint displaying nerve-root signature. The animal presented with lower motor neuron paresis with normal deep pain perception. Radiographic examination revealed narrowing of the lumbosacral joint disc space with endplate destructive lysis. Magnetic resonance imaging of the lumbosacral joint revealed a cauda equina compression, especially on the left. On T2 and T1-weighted images, a mass sized 1 × 1 cm was identified laterally to the left of the lumbosacral joint with hyperintense signal. The lumbosacral joint was stabilized by applying the dorsal distraction fixation-fusion technique and dorsal laminectomy. The soft tissue mass was removed, and a bacterial culture was performed. Coagulase-negative Staphylococcus spp. were detected and discospondylitis was treated with clindamycin for 6 weeks. The patient showed clinical improvement without pain and hindlimb paresis until 6 months follow-up postoperatively.

Geometry Design of a Pitch Controlling Type Horizontal Axis Turbine and Comparison of Power Coefficients (피치각 제어형 수평축 조류 터빈의 형상설계 및 출력계수 비교)

  • Park, Hoon Cheol;Truong, Quang-Tri;Phan, Le-Quang;Ko, Jin Hwan;Lee, Kwang-Soo;Le, Tuyen Quang;Kang, Taesam
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.3
    • /
    • pp.167-173
    • /
    • 2014
  • In this work, based on the blade element-momentum theory (BEMT), we proposed the geometry of a lab-scale horizontal axis tidal turbine with a diameter of 80cm, which can demonstrate the maximum power coefficient, and investigated the effect of blade pitch angle increase on the power coefficient. For validation of the computed power coefficients by the BEMT, we also computed the power coefficient using the computational fluid dynamics (CFD) for each case. For the CFD, 15 times of the turbine radius was used for the length and diameter of the computational domain, and the open boundary condition was prescribed at the boundary of the computational domain. The maximum power coefficients of the turbine acquired by the BEMT and CFD were about 48%, showing a good agreement. Both of the power coefficients computed by the BEMT and CFD tended to decrease when the blade pitch angle increases. The two power coefficients for a given tip-speed ratio were in good agreement. Through the present study, we have confirmed that we can trust the proposed geometry and the computed power coefficients based on the BEMT.

Survival and Histological Changes in Gill of the Rockfish, Sebastes schlegeli Following Exposure to Naphthalene (나프탈렌에 노출된 조피볼락의 생존 및 아가미의 조직학적 변화)

  • Cho, Jae Kwon;Kim, Tae Ik;Son, Maeng Hyun;Kim, Kyong Min;Jin, Young Guk
    • Korean Journal of Ichthyology
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • Rockfish, Sebastes schlegeli (total length; $10.36{\pm}0.49cm$, total weight; $16.28{\pm}1.86g$, N; 290) were exposed to various concentrations of naphthalene for 28 days. Exposure concentrations of naphthalene established control, ethanol (solvent) control, 0.5, 1.0, 1.5 and 2.0 mg Nap $L^{-1}$. After exposure, We observed survival rate, and degree of tissue change (DTC) in gill under optical microscopy. Survival rate of the rockfish was more than 90% in control, ethanol control, 0.5 and 1.0 mg Nap $L^{-1}$, whereas it decreased in 1.5 and 2.0 mg Nap $L^{-1}$ (respectively 80%, 62.2%). In histological observation of gill, hyperplasia of epithelial cells observed in all exposure groups. But no showed increase of DTC which was related to concentration. Whereas, DTC at fusion of gill lamellar, lamellar telangiectasia, stasis, aneurysm and necrosis showed dose dependent increase. Especially, fusion of gill lamellar, lamellar telangiectasia and stasis observed at more 1.0 mg Nap $L^{-1}$, and aneurysm and necrosis at more 1.5 mg Nap $L^{-1}$. These results showed naphthalene caused survival and severe change to the gill of the rockfish which was related to exposure concentration.

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Effect of Electric Stimulation on Parthenogenesis of In Vitro Matured Oocytes from Korean Native Cows (한우 체외성숙란의 단위발생에 대한 전기자극의 효과)

  • 노규진;공일근;곽대오;이효정;최상용;박충생
    • Journal of Embryo Transfer
    • /
    • v.9 no.2
    • /
    • pp.145-152
    • /
    • 1994
  • The suitable electric stimulation is essential for activation and fusion of oocytes before or after nuclear transplantation The present study was undertaken to determine the optirnal condition for the parthenogenetic activation of in vitro rnatured(IVM) bovine oocytes by electric stimulation. Different direct current(DC) electric voltage of 1.0, 1.5 and 2.0 kV/cm and pulse duration of 30, 60 and 120 $\mu$sec were applied to the JVM nocytes in 0.3 M mannitol solution containing each 100 $\mu$M CaCl$_2$ and MgCl$_2$. IVM occytes at 24, 28 and 32 hours Post-maturation(hpm) were also electrically stimulated at 1.5 kV /cm, for 60 $\mu$ sec. The stimulated nocytes were then co-cultured in TCM-199 solution containing 10% fetal calf serum with bovine oviductal epithelial cells for 7~9 days in a 5% $CO_2$ incubator at 39$^{\circ}C$ ~ Their activation and in vitro development to morula and blastocyst were assessed under an inverted microscope. The higher activation rates 62.8 and 63.4% and in vitro de- velopment rates to morula and blastocyst 5.1 and 10.9% were shown in the oocytes stimulated at the voltage of 1.0 and 1.5 kV/cm than 2.0 kV/cm, respectively. No signifi- cantly(P<0.05) different activation rate was shown in JVM oocytes stimulated for 30, 60 and 120 $\mu$sec, but developmental rates to morula and blastocyst was significantly(P<0.05) higher in the oocytes stimulated for 30 $\mu$sec(6~3%) and 60 $\mu$sec(10~0%) than 120 $\mu$sec(0~ 0%). The aged oocytes at 28 and 30 hpm showed significantly(P<0.05) higher activation rates(72~7 and 79.7%) than the oocytes at 24 hpm(50~9%)~ Also, their developmental rates to morula and blastocyst were significantly(P<0.05) higher in the nocytes at 28(14.3%) and 32 hpm(15.9%) than 24 hpm(3.6%). From these results, it can be suggested that the optimal electric stimulation for IVM bovine occytes is a DC voltage between 1.0 and 1.5 kV/cm, pulse duration of 30 or 60 $\mu$sec, and the optimal age of IVM oocytes for electric activation is at 32 hpm.

  • PDF

Characteristic Study of Small-sized and Planer Resonator for Mobile Device in Magnetic Wireless Power Transfer (소형 모바일 기기용 공진형 무선전력전송 시스템의 공진기 평면화 및 소형화에 따른 특성 연구)

  • Lee, Hoon-Hee;Jung, Chang-Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • In this paper, a Small-sized and planer resonator design of Magnetic Resonance - Wireless Power Transfer(MR-WPT) were proposed for practical applications of mobile devices, such as a laptop, a smart-phone and a tablet pc. The proposed MR-WPT system were based on four coil MR-WPT and designed as a transmitter part (Tx) and a receiver part (Rx) both are the same shape with the same loop and resonator. There are four different spiral coil type of resonators with variable of line length, width, gap and turns in $50mm{\times}50mm$ size. The both of top and bottom side of substrate(acrylic; ${\varepsilon}_r=2.56$, tan ${\delta}=0.008$) ere used to generate high inductance and capacitance in limited small volume. Loops were designed on the same plane of resonator to reduce their volume, and there are three different size. The proposed MR-WPT system were fabricated with two acrylic substrate plane of Tx and Rx each, the Rx and Tx loops and resonators were fabricated of copper sheets. There are 12 combinations of 3 loops and 4 resonators, each combination were measured to calculate transfer efficiency and resonance frequency in transfer distance from 1cm to 5cm. The measured results, the highest transfer efficiency was about 70%, and average transfer efficiency was 40%, on the resonance frequency was about 6.78 MHz, which is standard band by A4WP. We proposed small-sized and planer resonator of MR-WPT and showed possibility of mobile applications for small devices.