• Title/Summary/Keyword: CAP System

Search Result 415, Processing Time 0.031 seconds

New S-PVA Technology for Advanced LCD Performance

  • Um, Yoon-Sung;Park, Seung-Beom;Kim, Hoon;You, Hye-Ran;Lyu, Jae-Jin;Kim, Kyeong-Hyeon;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.403-406
    • /
    • 2007
  • A New S-PVA which is named as charge-shared super PVA (CS S-PVA) LCD mode is proposed. CS SPVA controls the voltage ratio of low pixel by sharing system between low pixel and control cap, resulting in improved off-axis image quality and transmittance increase without any side effects. Moreover, the new S-PVA LCD mode is free of image-sticking. Operating schemes and display performance of CS S-PVA are presented.

  • PDF

Electroencephalogram Analysis on Learning Factors during Relaxed or Concentrated Attention according to the Color Temperatures of LED Illuminance (이완집중 및 긴장집중 시 LED 조명의 색온도에 따른 학습요인의 뇌파분석)

  • Jee, Soon-Duk;Kim, Chae-Bogk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.21 no.6
    • /
    • pp.33-42
    • /
    • 2014
  • The objective of this study is to investigate learning factors (stability, attention and activation) in school by electroencephalogram (theta, alpha and beta waves) analysis during relaxed or concentrated. In order to measure electroencephalograms, MP 150 by Biopac and ECI Electro-Cap are employed. Three types of color temperatures (3000K, 5000K, 7000K) are used and 13 undergraduate and 12 graduate students are selected as experimental subjects. When subjects are relaxed during contemplation or concentrated during mental arithmetic, we compare with stability, attention and activation indices. The test results show that subjects were stable when color temperature is 5000K. Subjects gave best attention when color temperature is 7000K. Subjects activated well when color temperature is 3000K during relaxed attention. However, subjects activated rigorous when color temperature is 7000K during constrained attention.

Capacitor bank assisted Battery fed Boost Converter for self-electricity-generated transportation cart system (자가발전 이동 카트 시스템을 위한 배터리-캐패시터 뱅크를 갖는 부스트 컨버터)

  • Kong, Sung Jae;Yang, Tae Cheol;Kang, Kyung Soo;Roh, Chung Wook
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.130-131
    • /
    • 2017
  • 기존 이동 트레이의 경우 모터를 구동하기 위해 외부 전원장치가 필요하고 지속적인 유지보수가 필요한 문제점이 있다. 이를 해결하기 위해 외부 전원 장치가 아닌 발전기 바퀴를 통해 배터리를 충전하여 3배 이상 승압 가능한 Boost Converter로 모터를 구동한다. 하지만 모터 기동 시 필요한 순간적인 큰 전류를 배터리에서 공급하기 때문에 배터리의 수명이 감소되는 문제점이 있다. 본 논문에서는 3배 이상 승압이 가능하면서 배터리 부담을 줄이는 Super Cap. String을 사용하여 순간적으로 필요한 큰 전류를 공급하는 Boost Converter를 제안한다. 이를 이론적, 실험적 분석을 통해 그 타당성을 검증한다.

  • PDF

Study of sand blaster dry etched glass wafer surface for micro device package (샌드 블러스터로 건식 식각한 마이크로 소자 패키지용 유리 웨이퍼의 표면 연구)

  • Kim, Jong-Seok;Nam, Kwang-Woo;Choa, Sung-Hoon;Kwon, Jae-Hong;Ju, Byeong-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.245-250
    • /
    • 2006
  • In this paper, glass cap wafer for MEMS device package is fabricated by using sand blaster dry etcher and Its surface is studied. The surface of dry etched glass is analyzed by using SEM, and many glass particles and micro cracks are observed. If these kind of particles were dropped from glass to the surface of device, It would make critical failure to the operation of device. So, several cleaning and etching methods are induced to remove these kinds of dormant failure mode and optimized condition is found out.

A Analysis of Solidification of Castings by Computer (전산기(電算機)를 이용(利用)한 주물(鑄物)의 응고해석(凝固解析)에 관하여)

  • Yoon, Eui-Pak;Cho, Soon-Hyoung
    • Journal of Korea Foundry Society
    • /
    • v.3 no.2
    • /
    • pp.83-91
    • /
    • 1983
  • In this paper analytical and numerical methods fur analysis of solidification of castings are described, and the matrix method, one of numerical method, where the nodal point is designated on the element boundary was adapted. The cooling curve obtained by experimental values, when cast steel (0.29%C. 0.62%Si) was poured into $CO_2$ mold, is compared with that of computed values by exploiting computer (V77-600 Data Proceeding System, UNIVAC). The computed value is nearly approximation to the experimental. But the computed value shows a tendency that is a little higher than the experimental in solid-liquid coexisting temperature ranges and much lower than the experimental after solidification. It is considered to result from the lacks and difficulties of ultimately appropriate adaptation of various physical properties and also air cap between castings and mold.

  • PDF

Measurement and Analysis of Electromagnetic field for DC electric railway train (직류철도차량에 대한 자계측정 및 분석)

  • Jang, Dong-Uk;Kim, Min-Cheol;Lee, Chang-Mu;Han, Moon-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1637-1639
    • /
    • 2005
  • The measurement of magnetic field is performed about DC and AC magnetic field in test track of depot. The test point is cap, on the converter/inverter box, on the traction motor, on the APSE and on the line filter, the height of measurement is bottom and 50 cm height. In case of AC magnetic field, the selected specific frequency is measured on the converter/inverter box. The AC magnetic field is checked and analysis through RS-232C and notebook PC. The DC magnetic field is measured by using the Hall Probe, test result is saved and analysis by PXI system. On the line filter, the maximum value is 1.4 mT in case of DC magnetic field and 0.044 mT in case of AC magnetic field at 50 Hz.

  • PDF

SPECTRAL LOCALIZING SYSTEMS THAT ARE t-SPLITTING MULTIPLICATIVE SETS OF IDEALS

  • Chang, Gyu-Whan
    • Journal of the Korean Mathematical Society
    • /
    • v.44 no.4
    • /
    • pp.863-872
    • /
    • 2007
  • Let D be an integral domain with quotient field K, A a nonempty set of height-one maximal t-ideals of D, F$({\Lambda})={I{\subseteq}D|I$ is an ideal of D such that $I{\subseteq}P$ for all $P{\in}A}$, and $D_F({\Lambda})={x{\in}K|xA{\subseteq}D$ for some $A{\in}F({\Lambda})}$. In this paper, we prove that if each $P{\in}A$ is the radical of a finite type v-ideal (resp., a principal ideal), then $D_{F({\Lambda})}$ is a weakly Krull domain (resp., generalized weakly factorial domain) if and only if the intersection $D_{F({\Lambda})}={\cap}_{P{\in}A}D_P$ has finite character, if and only if $F({\Lambda})$ is a t-splitting set of ideals, if and only if $F({\Lambda})$ is v-finite.

A study on data sharing system based on threshold quorum consensus for fairness in permissioned blockchain (허가된 블록체인에서의 공정성을 보장하는 임계값 쿼럼 합의 기반의 데이터 공유 시스템에 관한 연구)

  • Ra, Gyeongjin;Lee, Imyeong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.334-336
    • /
    • 2021
  • 허가형 블록체인 기반 데이터 공유 시스템은 분산 환경에서 신뢰 수준을 구축하고 일관된 메시지를 기록 및 공유함으로써 서비스의 상호 운용성을 가능하게 한다. 그러나 허가형 블록체인은 종종 탈중앙화, 보안 및 상호 운용성과 충돌한다. 이는 중앙 집중식 시스템으로 돌아가거나 데이터의 독점 및 남용 및 오용으로 이어질 수 있다. 따라서 CAP (Consistency, Availability, Partition tolerance)에 이론 검증에 따라 메시지 공유, 비잔틴 내결함성 및 메시지 일관성을 고려하고 적용해야 한다. 기존의 PBFT(Practical Byzantine Fault Tolerance) 합의 알고리즘는 노드의 증가시, 장애내성을 갖기위해 계산되어야 할 합의 처리시간이 증가하며, DPOS(Delegated Proof of Stake) 알고리즘은 보상, 리더 선출의 공정성 문제 등에 따라 허가형 블록체인에서의 적합한 방식이 연구되고 있다. 본 논문에서는 서비스의 상호 운용성과 과제에 대해 논의하고 허가된 블록체인의 합의 개선을 통한 데이터 공유 시스템을 제안한다.

In Vitro Development of Porcine Parthenogenetic Embryos under the Oil-free Culture System

  • Park, Sang-Kyu;Choi, Young-Ju;Roh, Sang-Ho
    • Journal of Embryo Transfer
    • /
    • v.25 no.4
    • /
    • pp.259-262
    • /
    • 2010
  • Optimization of the preimplantation mammalian embryo culture condition was widely focused on refining medium composition under the name of chemically defined media. However, recent research revealed that the alteration of physical environment can be a crucial factor to a successful embryo development. In this study, under the same embryo density, a novel culture device named oil-free micro tube culture (MTC) system was evaluated using porcine parthenogenetic embryos. The activated oocytes were placed into the 0.2 ml thin-wall flat cap PCR tube and cultured to the blastocyst stage. As a preliminary step, embryo density and culture medium volume were optimized under a standard drop culture system. The optimal embryo density range for in vitro culture was 0.5 embryos per ${\mu}l$ in $20\;{\mu}l$ drop (20.5%) and 1.0 embryos per ${\mu}l$ in $10\;{\mu}l$ drop (20.6%). Based on these results, we compared drop culture system and 'MTC' system in terms of the developmental rate to the blastocyst stage. In $20\;{\mu}l$ medium volume, the 'MTC' system showed similar blastocyst formation rate when compared with drop culture system (20.2% versus 20.5%, respectively) while the 'MTC' system showed lower blastocyst formation rate than drop culture system in $10\;{\mu}l$ one (12.7% versus 20.0%, respectively). Therefore the $20\;{\mu}l$ MTC system may be an alternative incubation system for short-distance embryo transport without carrying the $CO_2$ incubator and this provides novel embryo culture device to clinical veterinary embryologists.

Implementation of a Medical Information Transmission Protocol Based on Mobile Wireless Communication (무선 이동통신 기술에 기반한 의료 정보 전송 프로토콜 구현)

  • 정희창;한민수
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.19-24
    • /
    • 1998
  • The main goal of this paper is to propose and to test a radio protocol based CSMA/CA (Carrier Sense Multiple Access with Collision Avoidance) for the purpose of enhancing the existing medical information system. The feature of the new medical information system, Medical Application Radio System(MARS), which operating in real time is the transmission of medical information in bi-direction between the hospital control office and patients mobile stations. MARS monitors patients linked to the network by radio and provides quick alarm, flexible documentation capabilities, asnd fast treatment for the analysis of collected medical data. The existing medical information system, radio telemetry system which transfers the message of patients to the CAP(Central Access Point) unit in one way at the speed of 9.6Kbps and operates a channel frequency bandwidth. To verify the Performance of the proposed system, we have performed the numerical analysis and have implemented a test system which consists of the 2.4Ghz radio transceiver and personal computer.

  • PDF