• Title/Summary/Keyword: CAD reference model

Search Result 58, Processing Time 0.027 seconds

Reference Feature Based Cell Decomposition and Form Feature Recognition (기준 특징형상에 기반한 셀 분해 및 특징형상 인식에 관한 연구)

  • Kim, Jae-Hyun;Park, Jung-Whan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.12 no.4
    • /
    • pp.245-254
    • /
    • 2007
  • This research proposed feature extraction algorithms as an input of STEP Ap214 data, and feature parameterization process to simplify further design change and maintenance. The procedure starts with suppression of blend faces of an input solid model to generate its simplified model, where both constant and variable-radius blends are considered. Most existing cell decomposition algorithms utilize concave edges, and they usually require complex procedures and computing time in recomposing the cells. The proposed algorithm using reference features, however, was found to be more efficient through testing with a few sample cases. In addition, the algorithm is able to recognize depression features, which is another strong point compared to the existing cell decomposition approaches. The proposed algorithm was implemented on a commercial CAD system and tested with selected industrial product models, along with parameterization of recognized features for further design change.

A comparison of three design tree based search algorithms for the detection of engineering parts constructed with CATIA V5 in large databases

  • Roj, Robin
    • Journal of Computational Design and Engineering
    • /
    • v.1 no.3
    • /
    • pp.161-172
    • /
    • 2014
  • This paper presents three different search engines for the detection of CAD-parts in large databases. The analysis of the contained information is performed by the export of the data that is stored in the structure trees of the CAD-models. A preparation program generates one XML-file for every model, which in addition to including the data of the structure tree, also owns certain physical properties of each part. The first search engine is specializes in the discovery of standard parts, like screws or washers. The second program uses certain user input as search parameters, and therefore has the ability to perform personalized queries. The third one compares one given reference part with all parts in the database, and locates files that are identical, or similar to, the reference part. All approaches run automatically, and have the analysis of the structure tree in common. Files constructed with CATIA V5, and search engines written with Python have been used for the implementation. The paper also includes a short comparison of the advantages and disadvantages of each program, as well as a performance test.

Evaluation on machining accuracy according to convergence angle and radius of curvature value used for fabricating custom abutments (맞춤형 지대주 제작에 사용되는 수렴 각과 곡률 반경의 값에 따른 가공 정확도 평가)

  • Hong, Min-Ho;Choi, Sung-Min;Kwon, Tae-Yub
    • Korean Journal of Dental Materials
    • /
    • v.44 no.4
    • /
    • pp.329-336
    • /
    • 2017
  • This study evaluates the machining accuracy of the custom abutment design according to the selected convergence angle and radius of curvature value in the CAD program. Ten custom abutments were designed based on dental CAD. And then, the fabricated custom abutment was scanned ten times using a contact scanner. The data of the scanned custom abutment was saved as "Test STL" file. The Geomagic studio software was used to superposition each exported as an "Test STL" file with the CAD-reference-model STL file (CRM) specified by the same name. In the experimental results, the A8 group (convergence angle $8^{\circ}$) showed lower error than the A4 group (convergence angle $4^{\circ}$) . In addition, the higher the radius of curvature, the less error in the top and chamfer regions of the custom abutment (p< 0.05). Overall, the convergence angle and radius of curvature value in the custom abutment design were found to affect the machining accuracy.

A Reference Model for the Computer-Aided Design of Hull Forms (전산 선형설계 시스템의 개발을 위한 기준모델)

  • Soon-Hung Han;Soon-Sub Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.4
    • /
    • pp.15-22
    • /
    • 1994
  • The efforts to utilize modern computers for the hull form design of ships, started in the 1960s. In Korea, tools for the computer-aided hull form design such as FORAN system have been used from the 1970s. However, the development efforts for such tools have just started. To maximize the output from the limited research resources in this field, a reference model for the development is proposed. The model cail be used to decompose the task into sub-tasks, and to integrate the separately developed component technologies afterwards. To produce the reference model, the state-of-the-arts has been surveyed. including both foreign and domestic researches, within both shipbuilding industry and general CAD sectors. In the process, component functions for the hull form design have been identified. The reference model is constructed using these identified component functions.

  • PDF

Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

  • Kim, Min-Kyu;Son, KeunBaDa;Yu, Beom-Young;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.361-368
    • /
    • 2020
  • PURPOSE. The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS. Seven reference models were fabricated based on the volumetric dimensions of complete arch (70%, 80%, 90%, 100%, 110%, 120%, and 130%). The reference models were digitized using an industrial scanner (Solutionix C500; MEDIT) for the fabrication of a computer-aided design (CAD) reference model (CRM). The reference models were digitized using three intraoral scanners (CS3600, Trios3, and i500) and one desktop scanner (E1) to fabricate a CAD test model (CTM). CRM and CTM were then superimposed using inspection software, and 3D analysis was conducted. For statistical analysis, one-way analysis of variance was used to verify the difference in accuracy based on the volumetric dimensions of the complete arch and the accuracy based on the scanners, and the differences among the groups were analyzed using the Tukey HSD test as a post-hoc test (α=.05). RESULTS. The three different scanners showed a significant difference in accuracy based on the volumetric dimensions of the complete arch (P<.05), but the desktop scanner did not show a significant difference in accuracy based on the volumetric dimensions of the complete arch (P=.808). CONCLUSION. The accuracy of the intraoral scanners was dependent on the volumetric dimensions of the complete arch, but the volumetric dimensions of the complete arch had no effect on the accuracy of the desktop scanner. Additionally, depending on the type of intraoral scanners, the accuracy differed according to the volumetric dimensions of the complete arch.

The comparison of accuracy on three-unit fixed dental prosthesis made with CAD/CAM milling machines (치과 캐드캠 밀링장비에 따른 3본브릿지의 정확도 비교)

  • Bae, So-Yeon;Park, Jin-Young;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the maxillary three-unit fixed dental prosthesis (FDPs) made using two CAD/CAM milling machines : DCM Group(Dentaim CAD/CAM milling machine), WCM Group(Wieland CAD/CAM milling machine). Methods: Each of 10 duplicate models was scanned by blue light scanner(Identica, Medit, Korea), and the three-unit FDPs (STL file) was designed using DelcamCAD. A total of 20 three-unit FDPs was fabricated, comprising 2 groups of 10 specimens each (shrinkage ratio is 1:1). The first three-unit FDPs STL file was used as a CAD reference model (CRM). Obtained STL files by scanning the inner surface of three-unit FDPs were convened into the point clouds-ASC II files. Discrepancies between the point clouds and CRM were measured by superimposition software. Statistical methods to analyze the data were used non-parametric method. The mean (SD) values were compared by a Mann-Whitney U-test. Type one error rate was set at 0.05. Results: WCM group had small discrepancies with $2.17{\mu}m$ of mean value compared to $4.44{\mu}m$ in DCM group. The accuracy values between the two groups showed a sratistically significant difference (Table 2, p<.05). Conclusion: The accuracy of the three-unit fixed dental prosthesis(FDPs) made of two CAD/CAM milling machines were statistically different. Accuracy with which the prosthesis made of WCM group was superior.

A Fast Generation Method of CAM Model for Machining of Jet Engines Using Shape Search (형상 검색을 이용한 제트엔진 절삭가공을 위한 빠른 CAM 모델 생성 방법)

  • Kim, Byung Chul;Song, Ilhwan;Shin, Suchul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.3
    • /
    • pp.327-336
    • /
    • 2016
  • Manufacturers of aircraft engines have introduced computer-aided manufacturing (CAM) software to operate and control computerized numerical control (CNC) machine tools. However, the generation of a CAM model is a time consuming and error-prone task since machining procedure and operational details are manually defined. For the automatic generation of a CAM model, feature recognition techniques have been widely studied. However, their recognition coverage is limited so that complex shapes such as a jet engine cannot be fully developed. This study presents a novel approach to quickly generate a CAM model from a CAD model using shape search techniques. Once an operator sets a machining operation as a reference operation, the same shapes as the shapes referenced by the operation are searched. The reference operation is copied to the positions of the searched shapes. The proposed method was verified through experiments with a jet engine compressor case.

A Study on the Architectural Design Utility of Object-based CAD System (객체기반 CAD 시스템의 건축설계적 효용에 관한 연구)

  • Yoo, Chang-Geun
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.2 no.1
    • /
    • pp.9-15
    • /
    • 2002
  • As architectural forms tend to be large-scaled, high-storied and complicated, use of computer for processing design information has been generalized. However, CAD use in the process of developing architectural design has been neglected greatly in the educational field of architectural field due to the surging of recognition that it may limit the essential property of architectural design. It may be resulted from the limitation of CAD system, that is, it is because of tardy speed of application development for the related areas with the lack of simplicity and clarity of flexibility to be secured on the drawing and user interface. Recent CAD systems, however, overcome such a limitation, convert into object-based design from entity-based drawing, drafting and modeling for implementing design concept of architects and it connects with internet linked to superspeed information communication network and changes process and stream of architectural design. Therefore, this study deals with utility of object based CAD system with products of Autodesk Co. and consequently obtain the following conclusions. First, it expands architect's design areas by supporting cooperative design system based on model-based architectural design and internet. Second, it reduces consumption of personal and material resources and time in the process of drawing production for improving architectural design works. Third, it can reduce the frequent design changes by improving understanding of architectural space with visualization of immediate 3D information, escaping from traditional methods to deliver design information to building owner through 2D drawing or model and perspective drawing requiring much cost and time. Fourth, it keeps exactness without omission or duplication of design information and generate and renew information of all related drawings on a drawing. Fifth, it is possible to change difficult and boring architectural design work into a pleasure owing to immediate modeling and drawing of design idea. In addition, digital drawing generated by using object-based CAD system can playa role of establishing Urban Information System to be used for protecting from building in disaster and urban disasters in connection with GIS numerical map and be used for reference of all kinds of information required fro post-management of buildings. However, what is more important is that surplus time from introduction of object-based CAD system should be used for consideration to be recognized as a good space and building built as a product of this project for comfort to urban people.

  • PDF

Coronary Artery Stenosis Quantification for Computed Tomography Angiography Based on Modified Student's t-Mixture Model

  • Sun, Qiaoyu;Yang, Guanyu;Shu, Huazhong;Shi, Daming
    • ETRI Journal
    • /
    • v.39 no.5
    • /
    • pp.662-671
    • /
    • 2017
  • Coronary artery disease (CAD) is a major cause of death in the world. As a non-invasive imaging modality, computed tomography angiography (CTA) is now usually used in clinical practice for CAD diagnosis. Precise quantification of coronary stenosis is of great interest for diagnosis and treatment planning. In this paper, a novel cluster method based on a Modified Student's t-Mixture Model is applied to separate the region of vessel lumen from other tissues. Then, the area of the vessel lumen in each slice is computed and the estimated value of it is fitted with a curve. Finally, the location and the level of the most stenoses are captured by comparing the calculated and fitted areas of the vessel. The proposed method has been applied to 17 clinical CTA datasets and the results have been compared with reference standard degrees of stenosis defined by an expert. The results of the experiment indicate that the proposed method can accurately quantify the stenosis of the coronary artery in CTA.

Three-dimensional evaluation on the repeatability and reproducibility of dental scanner-based digital models (치과용 스캐너로 채득한 디지털 모형의 반복성 및 재현성에 관한 3차원적 평가)

  • Lee, Gyeong-Tak;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.3
    • /
    • pp.213-220
    • /
    • 2012
  • Purpose: The aim of this study was to determine the repeatability and reproducibility of two dental scanners. Methods: The master die and the stone replicas(Kavo, Germany) were digitized in touch-probe scanner(Incise, Renishaw, UK), white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The number of points in the point clouds from each reading were calculated and used as the CAD reference model(CRM). Discrepancies between the points in the 3-dimensional surface models and the corresponding CRM were measured by a matching-software(Power-Inspect R2, Delcam Plc, UK). The t-student test for one samples were used for statistical analysis. Results: The reproducibility of both scanner was within $3{\mu}m$, based on mean value. The mean value between measurements made directly on the touch probe scanner digital models and those made on the white light scanner digital models was $2.20-2.90{\mu}m$, and was statistically significant(P<0.05). Conclusion: With respect to adequate data acquisition, the reproducibility of dental scanner differs. Three-dimensional analysis can be applied to differential quality analysis of the manufacturing process as well as to evaluation of different analysis methods.