• Title/Summary/Keyword: CAD/CAM dentistry

Search Result 455, Processing Time 0.025 seconds

The effects of different polishing techniques on the staining resistance of CAD/CAM resin-ceramics

  • Sagsoz, Omer;Demirci, Tevfik;Demirci, Gamze;Sagsoz, Nurdan Polat;Yildiz, Mehmet
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.417-422
    • /
    • 2016
  • PURPOSE. The purposes of this study were to evaluate the staining resistance of CAD/CAM resin-ceramics polished with different techniques and to determine the effectiveness of the polishing techniques on resin-ceramics, comparing it with that of a glazed glass-ceramic. MATERIALS AND METHODS. Four different CAD/CAM ceramics (feldspathic ceramic: C-CEREC Blocs, (SIRONA) and three resin-ceramics: L-Lava Ultimate, (3M ESPE), E-Enamic, (VITA) and CS-CeraSmart, (GC)) and one light cure composite resin: ME-Clearfil Majesty Esthetic (Kuraray) were used. Only C samples were glazed (gl). Other restorations were divided into four groups according to the polishing technique: nonpolished control group (c), a group polished with light cure liquid polish (Biscover LV BISCO) (bb), a group polished with ceramic polishing kit (Diapol, EVE) (cd), and a group polished with composite polishing kit (Clearfil Twist Dia, Kuraray) (kc). Glazed C samples and the polished samples were further divided into four subgroups and immersed into different solutions: distilled water, tea, coffee, and fermented black carrot juice. Eight samples ($8{\times}8{\times}1mm$) were prepared for each subgroup. According to CIELab system, four color measurements were made: before immersion, immersion after 1 day, after 1 week, and after 1 month. Data were analyzed with repeated measures of ANOVA (${\alpha}=.05$). RESULTS. The highest staining resistance was found in gl samples. There was no difference among gl, kc and cd (P>.05). Staining resistance of gl was significantly higher than that of bb (P<.05). Staining resistances of E and CS were significantly higher than those of L and ME (P<.05). CONCLUSION. Ceramic and composite polishing kits can be used for resin ceramics as a counterpart of glazing procedure used for full ceramic materials. Liquid polish has limited indications for resin ceramics.

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

Current Orthodontic Treatment using CAD/CAM technology: from orthodontic diagnosis to indirect bonding procedure (임상가를 위한 특집 2 - CAD/CAM 기술을 활용한 최신 교정치료 - 교정진단에서 간접부착술식까지)

  • Cha, Jung-Yul
    • The Journal of the Korean dental association
    • /
    • v.52 no.1
    • /
    • pp.17-26
    • /
    • 2014
  • Computerized 3D virtual dental models are currently available, and their use has started to improve treatment outcomes. The accuracy of digital models has been demonstrated by many studies and various intra-oral scanners are innovated for short scanning time and high precision. Recently, a digital model was combined with a high technology computer-driven system, which was developed for the application of a digital set-up and indirect bonding of lingual attachments. In this section, virtual treatment planning using a virtual set-up program is be introduced, and the clinical applications and accuracy of computer-generated indirect bonding are discussed.

Properties of Dental CAD/CAM Zirconia (CAD/CAM 지르코니아 재료의 특성)

  • Bae, Tae-Sung
    • The Journal of the Korean dental association
    • /
    • v.49 no.5
    • /
    • pp.260-264
    • /
    • 2011
  • Zirconia ($ZrO_2$) is a crystalline dioxide of zirconium. Dental zirconia blocks for CAD/CAM are usually fabricated with powders of tetragonal zirconia polycrystals (TZP) stabilized with 3mol% yttria. Because of its mechanical properties similar to those of metals and color similar to tooth, it is evaluated to attain the two purposes at a time, strength and aesthetic in prosthetic dentistry. The ability of transformation of Y-TZP from tetragonal to monoclinic helps to prevent crack propagation and contributes the increase of strength and fracture toughness. Two different types of blocks, soft and hard, are used to prepare the zirconia frameworks. The fuzzy-sintered block is difficult in machining, so pre-sintered soft 3Y-TZP block is usually used to mill by computer aided machining.

Potential of monolithic zirconia crown using Ko's coloring (심미 수복 치료의 관점에서 바라본 Ko's Coloring을 이용한 Monolithic zirconia crown의 가능성)

  • Ko, Kyung-Hun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.25 no.2
    • /
    • pp.109-126
    • /
    • 2016
  • According of the development and spread of CAD/CAM, a number of prostheses we have done had been replaced. Dental technicians have a difficulty reproducing natural color when producing these zirconia crowns. Difficulty reproducing natural color when producing these zirconia crowns. In my case, in the beginning of experimenting with zirconia, I had a hard time dealing with zirconia and I have tried solve these problems. Therefore, I would like to share Ko's coloring technique made of my effort with you.

A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems (치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구)

  • Jeong, Chang-Seop;Park, Jong-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.

Comparison of the mechanical properties and microstructures of fractured surface for Co-Cr alloy fabricated by conventional cast, 3-D printing laser-sintered and CAD/CAM milled techniques (주조, 3-D printing을 활용한 laser sintered 및 CAD/CAM milled 기법을 이용하여 제작된 코발트-크롬 합금의 물리적 성질 및 파절 단면 관찰 비교 연구)

  • Choi, Yun-Jung;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Ahn, Jin-Soo;Park, Dong-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2014
  • Purpose: The purpose of present study is to compare mechanical properties and microstructural characteristics of fractured surface for cast, 3-D printing laser sintered and CAD/CAM milled cobalt-chromium (Co-Cr) alloy specimens and to investigate whether laser sintered technique is adequate for dental applications. Materials and methods: Thirty six flat disc shape Co-Cr alloy specimens were fabricated for surface hardness test and divided into three groups according to the manufacturing methods; 12 specimens for casting (n=12), 12 specimens for laser sintered technology (n=12) and 12 specimens for milled technology (n=12). Twelve dumbbell shape specimens for each group were also fabricated for a tensile test. Statistical comparisons of the mechanical properties for the alloys were performed by Kruskal-Wallis test followed by Mann-Whitney and Bonferroni test. The microstructural characteristics of fractured surfaces were examined using SEM. Results: There were significant differences in the mean Vickers hardness values between all groups and the cast specimen showed the highest (455.88 Hv) while the CAD/CAM milled specimen showed the lowest (243.40 Hv). Significant differences were found among the three groups for ultimate tensile strength, 0.2% yield stress, elongation, and elastic modulus. The highest ultimate tensile strength value (1442.94 MPa) was shown in the milled group and the highest 0.2% yield strength (1136.15 MPa) was shown in the laser sintered group. Conclusion: Different manufacturing methods influence the mechanical properties and microstructure of the fractured surfaces in Co-Cr alloys. The cast Co-Cr alloy specimens showed the highest Vickers hardness, and the CAD/CAM milled specimens revealed the highest tensile strength value. All alloys represent adequate mechanical properties satisfying the ISO standards of dental alloy.

Retention of CAD/CAM Metal Copings Cemented on Short Titanium Abutments with Different Cements (짧은 티타늄 지대주에 합착된 CAD/CAM 금속 코핑의 시멘트 종류에 따른 유지력 비교)

  • Kim, Hyo-Jung;Song, Eun-Young;Yoon, Ji-Young;Lee, Si-Ho;Lee, Yong-Keun;Oh, Nam-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • State of problem: Cement-retained implant-supported prostheses are routinely used in dentistry. The use of high strength cements has become more popular with the increasing confidence in the stability of the implant-abutment screw connection and the high survival rates of osseointegrated implants. No clinical data on retention of metal copings using CAD/CAM. To evaluate retention of metal copings using CAD/CAM system bonded to short titanium abutment with four different cements and compare retentive strength of metal copings with sandblasting or without sandblasting before cementation. Forty titanium abutment blocks were fabricated and divided into 4 groups of 10 samples each. Forty metal copings with occlusal hole to allow for retention testing were fabricated using CAD/CAM technology. The four cements were Fujicem(Fuji, Japan), Maxcem Elite(Kerr, USA), Panavia F2.0(Kurarary, Japan) and Superbond C&B(Sunmedical, Japan). The copings were cemented on the titanium abutment according to manufacture's recommendation. All samples were stored for 24h at 37oC in 100% humidity and tested for retention using universal testing machine(Instron) at a crosshead speed of 1.0mm/min. Force at retentive failure was recorded in Newton. The mode of failure was also recorded. Means and standard deviations of loads at failure were analyzed using ANOVA and Paired t-test. Statistical significance was set at P<0.05. Panavia F2.0 provided significantly higher retentive strength than Fujicem, Maxcem Elite(P<0.05). Sandblasting significantly increased bond strength(P<0.05). The mode of failure was cement remaining principally on metal copings. Within the limitation of this study, Panavia F2.0 showed significantly stronger retentive strength than Fujicem, Maxcem Elite(p<0.05). The Ranking order of the cements to retain the copings was Panavia F2.0, Fujicem = Maxcem Elite. Sandblasting significantly increased bond strength(P<0.05). The retentive strength of metal copings on implant abutment were influenced by surface roughness and type of cements.

A study on the marginal fit of CAD/CAM 3-unit bridges (CAD/CAM 3-unit bridges의 변연 적합도에 관한 연구)

  • Lee, Ki-Hong;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.101-105
    • /
    • 2011
  • The purpose of this study was to assess the marginal fit of three-unit bridges produced using LAVA CAD/CAM (computer-aided design/computer-aided manufacturing) system and conventional PFG in vitro. Materials and methods: #11, 13 resin teeth were prepared on dentiform, then duplicated. Twenty resin models were fabricated, ten for PFG 3-unit bridges and ten for LAVA 3-unit bridges. Each bridge was cemented on the resin model. Marginal discrepancy was measured with stereoscopic microscope (Nikon DS-Fi 1, Nikon, Japan) at a magnification of ${\times}75$. Independent t-test was done for the statistical analysis. Results: The mean marginal discrepancy values and standard deviations of the PFG bridges was $97.1{\pm}18.7\;{\mu}m$ for incisors, $76.6{\pm}21.8\;{\mu}m$ for canines; that of the LAVA bridges was $90.4{\pm}26.7\;{\mu}m$ for incisor, $110.2{\pm}30.2\;{\mu}m$ for canines. The mean marginal discrepancy between PFG and LAVA for incisor did not show significant difference (P<.05). But for canine, the mean marginal discrepancy of PFG bridges was smaller than that of LAVA bridges (P<.05). Conclusion: The LAVA CAD/CAM 3-unit bridges and the PFG 3-unit bridges showed clinically acceptable marginal discrepancy.

MARGINAL ADAPTATION OF THE CONICAL INNER CROWN FABRICATED WITH CAD/CAM (CAD/CAM으로 제작한 코누스내관의 변연적합)

  • Kim In-Sup;Kang Dong-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.30-41
    • /
    • 2002
  • This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM. The informations on abutment teeth were transferred to a computer with a micro contact digitizer, which had a $50{\mu}m$ accuracy on the master die. A conical inner crown was designed on a computer and a real crown was machined based on this design using CAM. The marginal fit of a computer-machined conical inner crown was assessed using electron microscopy Measurement of the marginal gap between the conical inner crown and the abutment was performed on four different locations (mesial, distal, buccal, and lingual surfaces) of the finish line. The evaluation was based on 10 test specimens. The results were as follow. 1 The mean marginal gap between the conical inner crown and abutment tooth was $83.2{\pm}43{\mu}m$, 28.9% of the specimen showed marginal gap over $100{\mu}m$. 2. The fabrication method using CATRS and CAM provided clinically acceptable marginal fitness compared to conventional casting method (P<0.05).