• Title/Summary/Keyword: CA/TP

Search Result 74, Processing Time 0.031 seconds

Research on Design Capacity Evaluation of Low Impact Development according to Design Criteria (저영향개발 시설 설계 기준에 따른 용량 평가 방법 연구)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • The interest in LID facilities is increasing worldwide for recovery of natural water cycle system to destroy by urbanization. However, problems are raised when installation of LID because comprehensive analysis about design capacity adequacy of LID facilities was not conducted completely. In this research, removal efficiency and design volume adequacy of LID facilities were analyzed based on rainfall monitoring data in four LID facilities(Vegetated Swale, Vegetative Filter Strip, Bio-Retention and Permeable Pavement). As a result, group of LID facility designed on WQV was shown higher flow(37%) and pollutants(TSS, BOD, TN and TP) removal efficiencies(20 ~ 37%) than group of LID facility designed on WQF. SA/CA graph was drawn for evaluation of design volume adequacy based on rainfall monitoring data. In this SA/CA graph, coefficient of determination show over 0.5 in all parameter, especially, Flow and TP were show over 0.95. And, 'SA/CA & L/CA' graph considering difference of structure mechanism in LID facility suggested in this research was confirmed that improved coefficient of determination in flow, TSS and TP than SA/CA graph. According to this research results, feasibility of applying 'SA/CA & L/CA' graph for evaluation of design volume adequacy in LID facility, and it is necessary to follow up research for generalization and normalization.

Effect of Magnesium and Calcium Ions on the Phosphorus Removal by Aluminium Coagulation (마그네슘 및 칼슘 이온이 알루미늄 응집에 의한 인 제거에 미치는 영향)

  • Tian, Dong-Jie;Lee, Beom;Lee, Young-Ju;Jun, Hang-Bae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.231-236
    • /
    • 2011
  • The effects of magnesium and calcium ions on phosphorus removal by aluminium coagulation were investigated with various jar tests using settled raw sewage. Maximum TP (total phosphate) removal occurred at pH around 5~6 with aluminium coagulation, and it decreased above pH 6. TP and $H_nPO_4^{n-3}$ removal efficiencies, however, were kept above 95% at pH above 6 by adding the divalent metallic ions like magnesium or calcium ions on aluminium coagulation process. At molar ratio of Al/P ($Al^{3+}/H_nPO_4^{n-3}$) above 3, TP removal efficiency was as high as 80%, and residual TP less than 0.2 mg/L occurred at Al/P ratio above 6. TP removal efficiency was improved by adding magnesium or calcium ions and the optimum $Al^{3+}/Mg^{2+}$ and $Al^{3+}/Ca^{2+}$ ratios were about 2. The required dose of aluminium coagulant was reduced for equivalent amount of TP removal by adding magnesium or calcium ions, as a result sludge generation was also reduced.

The Development of GA with Priority-based Genetic Representation for Fixed Charge Transportation Problem (고정비용 수송문제를 위한 우선순위기반 유전자 표현법을 이용한 유전 알고리즘 개발)

  • Kim, Dong-Hun;Kim, Jong-Ryul;Jo, Jung-Bok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.793-796
    • /
    • 2008
  • 본 논문은 생산 물류 시스템최적화의 실현에 가장 대표적인 생산수송계획문제인 수송문제(TP: Transportation Problem)에 고정비용을 고려한 고정비용 수송문제(fcTP: Fixed charge Transportation Problem)를 다룬다. 특히 NP-hard문제로 널리 알려진 TP에서 수송량에 비례하는 가변비용과 함께 추가적으로 모든 경로에서 발생하는 고정비용을 함께 고려한 fcTP를 다룬다. 따라서 이러한 fcTP를 해결하기 위해 메타 휴리스틱기법 중에 가장 널리 이용되고 있는 유전 알고리즘(CA: Genetic Algorithm)을 이용한 해법을 제시하고자 한다. 본 논문에서는 CA를 이용해 고정비용 수송문제의 해를 우선순위기반 유전자 표현법을 이용해 fcTP에 적용해 보고 수치 실험을 통해 그 성능에 대한 연구를 한다.

  • PDF

Lung Adenocarcinoma Mutation Hotspot in Koreans: Oncogenic Mutation Potential of the TP53 P72R Single Nucleotide Polymorphism (한국인의 폐선암 돌연변이 핫스팟: TP53 P72R Single Nucleotide Polymorphism의 발암성 돌연변이 가능성)

  • Jae Ha BAEK;Kyu Bong CHO
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.93-104
    • /
    • 2023
  • This study aimed to identify new markers that cause lung adenocarcinoma by analyzing mutation hotspots for the top five genes with high mutation frequency in lung adenocarcinoma in Koreans by next generation sequencing (NGS) analysis. The association between TP53 mutation types and patterns with smoking, a major cause of lung cancer, was examined. The clinicopathological characteristics of lung adenocarcinoma patients with TP53 P72R SNPs were analyzed. In Korean lung adenocarcinoma cases, regardless of the smoking status, the TP53 P72R SNP was the most frequently occurring mutational hotspot, in which the nucleotide base was transversed from C to G, and the amino acid was substituted from proline to arginine at codon 72 of TP53. An analysis of the clinicopathological characteristics of lung adenocarcinoma cases with TP53 P72R SNP revealed no significant correlation with the patient's age, gender, smoking status, and tumor differentiation, but a significant correlation with low stage (P-value =0.026). This study confirmed an increase in TP53 rather than EGFR, which was reported as the most frequent mutations in lung adenocarcinoma in Koreans through NGS. Among them, TP53 P72R SNP is the most frequent regardless of smoking status.

Voltage-sensitive Calcium Channels Are Linked to P2X Purinoceptors in PC12 Cells

  • Hur, Eun-Mi;Park, Tae-Ju;Kim, Kyong-Tai
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1999.06a
    • /
    • pp.68-68
    • /
    • 1999
  • Extracellular A TP is known to function as a neurotransmitter and as a modulator in the variety of cell types. In PC12 cells, extracellular A TP elevates [Ca$\^$2+/]j through receptor-operated Ca$\^$2+/ channels and through the activation of phospholipase C, thereby facilitating the secretion of neurotransmitters.(omitted)

  • PDF

Empirical Study on Applicability of Phosphorus Recovery Process in Wastewater Treatment Plant (하수처리시설에서 인 회수공정의 도입 가능성에 대한 실증적 검토)

  • Park, Na-ri;Chang, Hyang-Youn;Lim, Hyun-Man;Ahn, Kwang-Ho;Kim, Weon-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.1
    • /
    • pp.40-49
    • /
    • 2017
  • In this study, we have made the annual total phosphorus (TP) mass balance diagrams for I wastewater treatment plant by utilizing the data of flow rate and TP of each process and tried to choose the optimum unit process empirically for phosphorus recovery. For the applicability evaluation, we have suggested several quantitative indices of flow rate, TP concentration, TP load and SS. Based on the analyses of TP mass balance, it became clear for reducing TP load of the wastewater treatment plant that it is efficient to recover phosphorus from the side stream in which the amount of flow rate is just 1/16, but TP concentration and load are 78 and 4.8 times larger than those of the influent of the plant. After the detailed applicability evaluation for the side stream, it could be concluded that the unit process of waste activated sludge thickener supernatant or dehydration filtrate are appropriate. Meanwhile, we did fundamental experiments utilizing the dewatering filtrate with TP concentration of 141.5 mg/L. After adjusting pH 10 and $Ca^{2+}$ concentration 250, 500, 1000 mg/L, it was stirred slowly. As a result, the $PO_4-P$ and TP removal efficiencies were above 95 percent; the results of the experiment imply the applicability of phosphorus recovery process in a wastewater treatment plant strongly.

Studies on body types by body growth and blood chemical values in the Jindo dog 1. Blood chemical values of Jindo dogs (진도견의 혈액화학치 및 성장에 따른 체형에 관한 연구 I. 진도견의 혈액화학치)

  • Kim, Woo-kwon;Lee, Jae-hong;Kim, Ja-suk
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.3
    • /
    • pp.263-274
    • /
    • 1989
  • The present study was conducted ill. order to get the normal blood chemical values of Korean Jindo dogs. Blood samples were taken from 160(♂34, ♀126) healthy Jindo dogs in Jindo area. The results obtained in this study were summarized as follows: 1. The mean values of serum total protein(TP), albumin(Alb) and globulin(Glb) content, cholesterol(Chole), magnesium(Mg), calcium(Ca), inorganic phosphate(P), potassium(K), sodium(Na) and chloride(Cl) concentration in the group of less than one year old were 6.64(♂6.62, ♀6.64), 3.63(♂3.57, ♀3.65) and 3.00(♂3.05, ♀2.99)g/100ml, 170.97(♂166.46, ♀172.68)mg/100ml, 1.45(♂1.43, ♀1.46), 5.76(♂5.62, ♀5.81), 4.80(♂4.95, ♀4.75), 4.84(♂4.72, ♀4.89), 148.93(♂148.79, ♀148.98) and 110.22(♂110.42, ♀110.14)mEq/L, respectively, whereas the TP, Alb and Glb content, Chole Mg, Ca, P, K, Na and Cl concentration in the group of one year old and more were 6.88(♂6.84, ♀6.89), 3.65(♂3.63, ♀3.66) and 3.23(♂3.21, ♀3.23)g/100ml, 167.48(♂173.80, ♀166.48)mg/100ml, 1.40(♂1.36, ♀1.40), 5.69(♂5.53, ♀5.71), 4.62(♂4.73, ♀4.60), 4.88(♂4.90, ♀4.87), 149.86(♂149.60, ♀149.90) and 110.03(♂110.70, ♀109.92)mEq/L, respectively. The ratios of mean serum albumin to globulin(A/G), calcium to inorganic phosphate(Ca/P) and sodium to potassium(Na/K) in the group of less than one year old were 1.21(♂1.17, ♀1.22), 1.20(♂1.14, ♀1.22) and 30.77(♂31.52, ♀30.47), respectively, whereas the A/G, Ca/P and Na/K in the group of one year old and more were 1.13(♂1.13, ♀1.13), 1.23(♂1.17, ♀1.24) and 30.71(♂30.53, ♀30.78), respectively. 2. The mean values of Alb content, Mg, Ca and K concentration, A/G and Ca/P ratio appeared to be higher in the female than in the male, whereas the reverse was the case with P concentration. No differences were found between male and female in the TP and Glb content, Chole, Na and Cl concentration and Na/K ratio. 3. The mean values of Glb content appeared to be higher in the group less than one year old than in the group of one year old and more, whereas the reverse was the case with A/G ratio. The mean values of TP and Alb content and Ca/P ratio in the age groups less than one year tended to increase with aging, whereas the reverse was the case with Ca and P concentration. No differences were found between age groups in the Mg, K, Na and Cl concentration and Na/K ratio.

  • PDF

Feedback Regulation of ATP-induced $Ca^{2+}$ Signaling in HL-60 Cells

  • Lee, Hyosang;Suh, Byung-Chang;Kim, Kyong-Tai
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1997.07a
    • /
    • pp.33-33
    • /
    • 1997
  • In HL-60 cells, extracellular A TP increases intracellular $Ca^{2+}$ ([Ca$^{2+}$]$_{i}$) in a concentration-dependent manner with the maximal response occurring around 10 $\mu$M. However, above the maximal responsive concentration ATP elicits different patterns of $Ca^{2+}$ signaling.(omitted)d)

  • PDF

Melting and Analysis of Antibacterial and Far-Infrared Emission Glass for the mass production (항균ㆍ원적외선방사 유리의 양산화를 위한 용융 및 분석)

  • 권면주;윤태민;윤영진;이용수;강원호
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.05a
    • /
    • pp.74-76
    • /
    • 2002
  • 항균성 및 원적외선 방사량이 높은 원적외선 방사 항균 글라스 및 글라스 세라믹스의 양산화를 위한 유리 용융에 있어 대량용융의 가능성을 확인할 수 있었으며, 열처리온도는 5Li₂Oㆍ36CaOㆍ20TiO₂ㆍ27P₂O/sub 5/와 1Ag₂Oㆍ4Li₂Oㆍ36CaOㆍ20TiO₂ㆍ27P₂O/sub 5/ 조성에서 최적핵형성온도가 620℃, 최적결정성장온도가 각각 78℃, 800℃였다. 원가절감을 위산 건식법과 습식법의 결정상분석의 결과 피크의 차이는 거의 없었다. 이온교환의 경우 5.0mol AgNO₃수용액에 담지한 시편에서는 많은 LTP 결정상이 AgTP 결정상으로 변환되기 시작하여 1.0omol 농도의 AgNO₃ 수용액에서는 결정상의 주피크가 AgTP 절정상으로 변이 되었다. 이 결과로 AgNO₃ 수음액 0.5mol 농도 이상의 이온교환시 항균특성에 있어서도 매우 유리하리라 예상되어진다.

Fabrication of Disposable pH Sensor with Micro-volume Type (Micro-volume형 일회용 pH 센서 제작)

  • Jung, Ho;Kim, Heung-Rak;Kim, Young-Duk;Jung, Woo-Chul;Kim, Dong-Su;Nam, Hyo-Duk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.950-952
    • /
    • 2003
  • This paper have been studied fabrication and characteristics of disposable pH sensor using MEMS technology. The sensor has two open-well structure, the container for the internal electrolyte and electrode were formed by anisotropically etching a silicon substrate. unlike currently used KCI saturated solution, the structure was introduced hydrogel which take an advantage of miniaturization, bulk product, a low price. PU and CA/TP used to measurement ion detection, one is reference membrane and the other is pH. fabricated sensor is encapsulated entirely with epoxy, finally sensor was estimated various ion sorts and pH ranges.

  • PDF