• Title/Summary/Keyword: C.V.A.

Search Result 10,497, Processing Time 0.038 seconds

Electrical Properties of Zn-Pr-Co-Cr-Er Oxides-based Varistors (Zn-Pr-Co-Cr-Er 산화물계 바이스터의 전기적 성질)

  • 남춘우;류정선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.5
    • /
    • pp.362-369
    • /
    • 2001
  • The electrical properties of varistors consisting of Zn-Pr-Co-Cr-Er oxides were investigated in the Er$_2$O$_3$content range of 0.0 to 2.0 mol%. the varistors without Er$_2$O$_3$ exhibited a relatively low nonlinearity, which was 14.24 in the nonlinear exponent and 21.47 $\mu$A in the leakage current. However, the varistors with Er$_2$O$_3$ sintered at 1335$^{\circ}C$ for 1h exhibited very high nonlinear exponent of 70, in particular, reaching a maximum value of 78.05 in 2.0 mol% Er$_2$O$_3$, and those sintered at 1335$^{\circ}C$ for 2h exhibited the nonlinear exponent close to 50, in particular, reaching a maximum value of52.76 in 0.5 mol% Er$_2$O$_3$. The others except for 0.5 mol% Er$_2$O$_3$-added varistors exhibited very high instability resulting in a thermal runaway within a short time, even a weak DC stress. Increasing soaking time decreased the nonlinearity, but increased the stability. The varistors containing 0.5mol% Er$_2$O$_3$ sintered for 2h exhibited excellent stability, in which the variation rate of the varistor voltage and nonlinear exponent was -1.70% and -7.15%, respectively, under more severe DC stress such as (0.80 V$_{1mA}$/9$0^{\circ}C$/12h)+(0.85 V$_{1mA}$/115$^{\circ}C$/12h)+(0.90 V$_{1mA}$/12$0^{\circ}C$/12h)+(0.95 V$_{1mA}$/1$25^{\circ}C$/12h)+(0.95 V$_{1mA}$/15$0^{\circ}C$/12h).TEX>/12h).

  • PDF

Effect of Matrix Structures on the Fracture Characteristics of Austempered C/V Graphite Iron (오스템퍼링처리한 C/V흑연주철의 파괴특성에 미치는 기지조직의 영향에 관한 연구)

  • Kim, Chang-Gyu;Kim, Hong-Beum;Choi, Chang-Ock
    • Journal of Korea Foundry Society
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 1996
  • Effect of various austempered structures on fracture characteristics of C/V graphite cast iron has studied. The tensile strength and hardness reached the maximum value of 971.4MPa and HB302 at the austempering temperature of $250^{\circ}C$, respectively. As the austempering temperature increased, the amount of retained austenite increased from 18% to 22, 29%, while $K_{IC}$ values ranged from the value of $65MPa{\cdot}m^{12} to 70MPa{\cdot}m^{1/2}, 66MPa{\cdot}m^{1/2}. This fact that $K_{IC}$ value was not sensitive to the increase of the amount of the retained austenite was that $K_{IC}$ was dependent on the matrix structure in lower bainitic matrix, while dependent on the notch effect from C/V graphite shape in upper bainitic matrix. Fractured surfaces showed a ductile fracture pattern at $300^{\circ}C$. Very large coalescence by C/V graphite and relatively small voids by spheroidal graphite were observed.

  • PDF

The Estimation of the Constrained Modulus and the Coefficient of Consolidation from the Piezocone Penetration Test Data (피에조 콘 관입시험결과에 따른 구속탄성계수, 압밀계수 산정에 관한 연구)

  • Lee, Kise;Ku, Namshil;Han, Woonwoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.4
    • /
    • pp.47-55
    • /
    • 2007
  • Using the results of the Piezocone Penetration Test (PCPT) which were executed at the Yangsan-Mulgum site, the applicability of the interpretation methods for estimating the coefficient of consolidation ($C_v$) of soft clay was evaluated. At the same time, laboratory soil tests using the total of 172 undisturbed soft clay samples from the 44 regions of the Yangsan-Mulgum site were performed to study the differency in the coefficient of consolidation ($C_v$) compared to the results of PCPT. The calculated constrained modulus ($M_{\varepsilon}$) and coefficient of consolidation ($C_v$) using the results of consolidation laboratory tests which are based upon the consolidation theory of Terzaghi were compared with the predicted constrained modulus ($M_p$) and coefficient of consolidation ($C_{v-{M_p}}$) from the PCPT. The relationship between the predicted constrained modulus ($M_p$) and the calculated constrained modulus($M_c$) were showed good correlation. The $M_p$ by the Jones & Rust method were showed mostly similar to the calculated constrained modulus ($M_c$). The relationship between the coefficient of consolidation ($C_v$) obtained from the consolidation tests and the calculated coefficient of consolidation ($C_{v-{M_p}}$) were showed a linear relationship. The results of the calculated coefficient of consolidation ($C_{v-{M_p}}$) were about 54% of the value of the coefficient of consolidation ($C_v$) obtained from the consolidation tests.

  • PDF

Analysis of whole genome sequencing and virulence factors of Vibrio vulnificus 1908-10 isolated from sea water at Gadeok island coast

  • Hee-kyung Oh;Nameun Kim;Do-Hyung Kim;Hye-Young Shin;Eun-Woo Lee;Sung-Hwan Eom;Young-Mog Kim
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.9
    • /
    • pp.558-568
    • /
    • 2023
  • Vibrio vulnificus is an aquatic bacterium causing septicemia and wound infection in humans. To understand this pathogen at the genomic level, it was performed whole genome sequencing of a cefoxitin-resistant strain, V. vulnificus 1908-10 possessing virulence-related genes (vvhA, viuB, and vcgC) isolated from Gadeok island coastal seawater in South Korea. The genome of V. vulnificus 1908-10 consisted of two circular contigs and no plasmid. The total genome size was estimated to be 5,018,425 bp with a guanine-cytosine (GC) content of 46.9%. We found 119 tRNA and 34 rRNA genes respectively in the genome, along with 4,352 predicted protein sequences. Virulence factor (VF) analysis further revealed that V. vulnificus 1908-10 possess various virulence genes in classes of adherence, antiphagocytosis, chemotaxis and motility, iron uptake, quorum sensing, secretion system, and toxin. In the comparison of the presence/absence of virulence genes, V. vulnificus 1908-10 had fur, hlyU, luxS, ompU, pilA, pilF, rtxA, rtxC, and vvhA. Of the 30 V. vulnificus comparative strains, 80% of the C-genotype strains have all of these genes, whereas 40% of the E-genotype strains have all of them. In particular, pilA were identified in 80% of the C-type strains and 40% of the E-type strains, showing more difference than other genes. Therefore, V. vulnificus 1908-10 had similar VF characteristics to those of type C strains. Multifunctional-autoprocessing repeats-in-toxin (MARTX) toxin of V. vulnificus 1908-10 contained 8 A-type repeats (GXXGXXXXXG), 25 B.1-type repeats (TXVGXGXX), 18 B2-type repeats (GGXGXDXXX), and 7 C-type repeats (GGXGXDXXX). The National Center for Biotechnology Information (NCBI) Basic Local Alignment Search Tool (BLAST) showed that the RtxA protein of V. vulnificus 1908-10 had the effector domain in the order of cross-liking domain (ACD)-C58_PaToxP-like domain- α/β hydrolase-C58_PaToxP-like domain.

The Application of Frequency Modulated Quartz Oscillator Using a V.V.C. Diode. (VVC 다이오드를 사용한 수정주파수 변조기의 응용)

  • Jeong, Man-Yeong;Kim, Yeong-Ung;Kim, Byeong-Sik
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.5
    • /
    • pp.19-26
    • /
    • 1972
  • A newly developed quartz frequency modulator utili3ing a V. V. C. diode is briefly described. Its electrical characteristics-including modulation linearity, modulation distortion, and carrier frequency stability depending upon the variation of the environmental temperature and the applied power voltage, etc.-are suitable for the modulator of a mobile or a portable F.M. transmitter according to the experimental results. The excellent over-all electrical characteristics were proved from the experimental development of the two kinds of transceivers. One is the single channal transceiver which contains a direct frequency modulator at the carrier frequency of 52.750 MHg. The other is the dual channel transceiver (the frequencies are selected from about 40 channels without tuning adjustment) whose operational frequency is composed of a modulated frequency of 10.7 MHz and the frequency generated at a channel control oscillator, As mentioned above, it is realized that the electrical characteristics of this modulation method are suitable for portable F. M. transceivers.

  • PDF

POSITIVE SOLUTION FOR A CLASS OF NONLOCAL ELLIPTIC SYSTEM WITH MULTIPLE PARAMETERS AND SINGULAR WEIGHTS

  • AFROUZI, G.A.;ZAHMATKESH, H.
    • Journal of applied mathematics & informatics
    • /
    • v.35 no.1_2
    • /
    • pp.121-130
    • /
    • 2017
  • This study is concerned with the existence of positive solution for the following nonlinear elliptic system $$\{-M_1(\int_{\Omega}{\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^pdx)div({\mid}x{\mid}^{-ap}{\mid}{\nabla}u{\mid}^{p-2}{\nabla}u)\\{\hfill{120}}={\mid}x{\mid}^{-(a+1)p+c_1}\({\alpha}_1A_1(x)f(v)+{\beta}_1B_1(x)h(u)\),\;x{\in}{\Omega},\\-M_2(\int_{\Omega}{\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^qdx)div({\mid}x{\mid}^{-bq}{\mid}{\nabla}v{\mid}^{q-2}{\nabla}v)\\{\hfill{120}}={\mid}x{\mid}^{-(b+1)q+c_2}\({\alpha}_2A_2(x)g(u)+{\beta}_2B_2(x)k(v)\),\;x{\in}{\Omega},\\{u=v=0,\;x{\in}{\partial}{\Omega},$$ where ${\Omega}$ is a bounded smooth domain of ${\mathbb{R}}^N$ with $0{\in}{\Omega}$, 1 < p, q < N, $0{\leq}a$ < $\frac{N-p}{p}$, $0{\leq}b$ < $\frac{N-q}{q}$ and ${\alpha}_i,{\beta}_i,c_i$ are positive parameters. Here $M_i,A_i,B_i,f,g,h,k$ are continuous functions and we discuss the existence of positive solution when they satisfy certain additional conditions. Our approach is based on the sub and super solutions method.

PSEUDOLINDELOF SPACES AND HEWITT REALCOMPACTIFICATION OF PRODUCTS

  • Kim, Chang-Il
    • The Pure and Applied Mathematics
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 1999
  • The concept of pseudoLindelof spaces is introduced. It is shown that the followings are equivalent: (a) for any two disjoint zero-sets in X, at least one of them is Lindelof, (b) $\mid$vX{\;}-{\;}X$\mid${\leq}{\;}1$, and (c) for any space T with $X{\;}{\subseteq}{\;}T$, there is an embedding $f{\;}:{\;}vX{\;}{\rightarrow}{\;}vT$ such that f(x) = x for all $x{\;}{\in}{\;}X$ and that if $X{\;}{\times}{\;}Y$ is a z-embedded pseudoLindelof subspace of $vX{\;}{\times}{\;}vY,{\;}then{\;}v(X{\;}{\times}{\;}Y){\;}={\;}vX{\;}{\times}{\;}vY$.

  • PDF

A Low-Power CMOS Current Reference Circuit (저전력 CMOS 기준전류 발생회로)

  • 김유환;권덕기;이종렬;유종근
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.89-92
    • /
    • 2001
  • In this paper, a simple low-power CMOS current reference circuit is proposed. The reference circuit includes parasitic pnp BJTs and resistors. Temperature compensation is made by adding a current component proportional to a thermal voltage to a current component proportional to a base-to-emitter voltage. The designed circuit has been simulated using a 0.25${\mu}{\textrm}{m}$ n-well CMOS process parameters. The simulation results show that the reference current is 34.96$mutextrm{A}$$\pm$0.04$mutextrm{A}$ in the temperature range of -2$0^{\circ}C$ to 12$0^{\circ}C$ The reference current varies less than 0.6% when the power supply voltage changes from 2.5V to 3.5V For $V_{DD=5V}$ and T=3$0^{\circ}C$ the power consumption is 520㎼ during normal operation but reduces to 0.l㎻ during power-down mode.

  • PDF

Effect of deposition temperature on field emission property of carbon thin film grown by PECVD (PECVD에 의해 작성된 탄소계 박막의 전계전자방출특성에 대한 증착온도 의존성에 관한 연구)

  • ;;M. Katayama;;K. Oura
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • Using RF plasma enhanced chemical vapor deposition, amorphous carbon films were grown in pure methane plasma. Field electron emission of these films were examined at a function of deposition temperature. It was found that the electron emission current of the sample prepared at deposition temperature above $600^{\circ}C$ was considerably improved. The film grown at deposition temperature of $800^{\circ}C$ had the best threshold field of 8 V/$\mu\textrm{m}$ in this experiment. According to the results of Raman spectroscopy. growth of graphite crystallites was promoted with higher deposition temperatures. Moreover the surface morphology was abruptly changed at deposition temperature above $600^{\circ}C$. We discuss the field electron emission characteristics of amorphous carbon films with regard to the structural feature and surface morphology.

Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study

  • Kwak, Se-Jung;Kim, Young-Min;Baek, Hee Jin;Kim, Se Hong;Yim, Hyeon Woo
    • Clinical and Experimental Emergency Medicine
    • /
    • v.3 no.3
    • /
    • pp.148-157
    • /
    • 2016
  • Objective Our aim was to compare the compression quality, exercise intensity, and energy expenditure in 5-minute single-rescuer cardiopulmonary resuscitation (CPR) using 15:1 or 30:2 compression-to-ventilation (C:V) ratios or chest compression only (CCO). Methods This was a randomized, crossover manikin study. Medical students were randomized to perform either type of CPR and do the others with intervals of at least 1 day. We measured compression quality, ratings of perceived exertion (RPE) score, heart rate, maximal oxygen uptake, and energy expenditure during CPR. Results Forty-seven students were recruited. Mean compression rates did not differ between the 3 groups. However, the mean percentage of adequate compressions in the CCO group was significantly lower than that of the 15:1 or 30:2 group ($31.2{\pm}30.3%$ vs. $55.1{\pm}37.5%$ vs. $54.0{\pm}36.9%$, respectively; P<0.001) and the difference occurred within the first minute. The RPE score in each minute and heart rate change in the CCO group was significantly higher than those of the C:V ratio groups. There was no significant difference in maximal oxygen uptake between the 3 groups. Energy expenditure in the CCO group was relatively lower than that of the 2 C:V ratio groups. Conclusion CPR using a 15:1 C:V ratio may provide a compression quality and exercise intensity comparable to those obtained using a 30:2 C:V ratio. An earlier decrease in compression quality and increase in RPE and heart rate could be produced by CCO CPR compared with 15:1 or 30:2 C:V ratios with relatively lower oxygen uptake and energy expenditure.