• Title/Summary/Keyword: C-M modules

Search Result 135, Processing Time 0.029 seconds

SIMMER extension for multigroup energy structure search using genetic algorithm with different fitness functions

  • Massone, Mattia;Gabrielli, Fabrizio;Rineiski, Andrei
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1250-1258
    • /
    • 2017
  • The multigroup transport theory is the basis for many neutronics modules. A significant point of the cross-section (XS) generation procedure is the choice of the energy groups' boundaries in the XS libraries, which must be carefully selected as an unsuitable energy meshing can easily lead to inaccurate results. This decision can require considerable effort and is particularly difficult for the common user, especially if not well-versed in reactor physics. This work investigates a genetic algorithm-based tool which selects an appropriate XS energy structure (ES) specific for the considered problem, to be used for the condensation of a fine multigroup library. The procedure is accelerated by results storage and fitness calculation speedup and can be easily parallelized. The extension is applied to the coupled code SIMMER and tested on the European Sustainable Nuclear Industrial Initiative (ESNII+) Advanced Sodium Technological Reactor for Industrial Demonstration (ASTRID)-like reactor system with different fitness functions. The results show that, when the libraries are condensed based on the ESs suggested by the algorithm, the code actually returns the correct multiplication factor, in both reference and voided conditions. The computational effort reduction obtained by using the condensed library rather than the fine one is assessed and is much higher than the time required for the ES search.

Uncertainty in Scenarios and Its Impact on Post Closure Long Term Safety Assessment in a Potential HLW Repository

  • Y.S. Hwang;Kim, S-K;Kang, C-H
    • Nuclear Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.108-120
    • /
    • 2003
  • In assessing the long term post closure radiological safety assessment of a potential HLW repository in Korea, three categories of uncertainties exist. The first one is the scenario uncertainty where series of different natural events are translated into written statements. The second one is the modeling uncertatinty where different mathematical models are applied for an identical scenario. The last one is the data uncertainty which can be expressed in terms of probabilistic density functions. In this analysis, three different scenarios are seleceted; a small well scenario, a radiolysis scenario, and a naturally discharged scenario. The MASCOT-K and the AMBER, probabilistic safety assessment codes based on connection of sub-modules and a compartment theory respectively, are applied to assess annual individual doses for a generic biosphere. Results illustrate that for a given scenario, predictions from two different codes fairly match well each other But the discrepancies for the different scenarios are significant. However, total doses are still well below the guideline of 2 mRem/yr. Detailed analyses with model and data uncertainties are underway to further assure the safety of a Korean reference dispsoal concept.

A Comparative Study of Production of [68Ga]PSMA-11 with or without Cassette Type Modules (비 카세트 방식과 카세트 방식을 이용한 [68Ga]PSMA-11의 자동 합성 방법 비교)

  • Hyun-Sik, Park;Byeong-Min, Jo;Hyun-Ho, An;Hong-Jin, Lee;Jin-Hyeong, Lee;Gyeong-Jae, Lee;Byung-Chul, Lee;Won-Woo, Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.15-19
    • /
    • 2022
  • Purpose [68Ga]PSMA-11 is needed the high reproducibility, excellent radiochemical yield and purity. In term of radiation safety, the radiation exposure of operator for its production also should be considered. In this work, we performed a comparative study for the fully automated synthesis of [68Ga]PSMA-11 between non-cassette type and cassette type. Materials and Methods Two different type of modules (TRACERlab FX N pro for non-cassette type and BIKBox for cassette type) were used for the automated production of [68Ga]PSMA-11. According to the previously identified elution profile, Only 2.5 ml with high radioactivity was used for the reaction. After adjusting the pH of the reaction solution with HEPES buffer solution, the precursor was added and reacted with at 95 ℃ for 15 minutes. The reaction mixture was separated and purified using a C18 light cartridge. The product was eluted with 50% EtOH/saline solution and diluted with saline. It was completed by sterilizing filter. In the non-cassette type, the aforementioned process must be prepared directly. However, in the cassette method, synthesis was possible simply by installing a kit that was already completed. Results Both total [68Ga]PSMA-11 production time were 25±3(non-cassette type) and 23±3 minutes(cassette type). The radiochemical yield of the non-cassette type(65.5±5.7%) was higher than that of the cassette type(61.6±4.8%) after sterilization filter. The non-cassette type took about 120 minutes of preparation time before synthesis due to washing of synthesizer and reagent preparation. However, since the cassette type does not require washing and reagent preparation, it took about 20 minutes to prepare before synthesis. Both type of synthesizer had a radiochemical high purity(>99%). Conclusion The non-cassette type production of [68Ga]PSMA-11 showed higher radiochemical yield and lower cost than the cassette type. However, The cassette type has an advantage in terms of preparation time, convenience, and equipment maintenance.

Development of A Three-Variable Canopy Photosynthetic Rate Model of Romaine Lettuce (Lactuca sativa L.) Grown in Plant Factory Modules Using Light Intensity, Temperature, and Growth Stage (광도, 온도, 생육 시기에 따른 식물공장 모듈 재배 로메인 상추의 3 변수 군락 광합성 모델 개발)

  • Jung, Dae Ho;Yoon, Hyo In;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.268-275
    • /
    • 2017
  • The photosynthetic rates of crops depend on growth environment factors, such as light intensity and temperature, and their photosynthetic efficiencies vary with growth stage. The objective of this study was to compare two different models expressing canopy photosynthetic rates of romaine lettuce (Lactuca sativa L., cv. Asia Heuk romaine) using three variables of light intensity, temperature, and growth stage. The canopy photosynthetic rates of the plants were measured 4, 7, 14, 21, and 28 days after transplanting at closed acrylic chambers ($1.0{\times}0.8{\times}0.5m$) using light-emitting diodes, in which indoor temperature and light intensity were designed to change from 19 to $28^{\circ}C$ and 50 to $500{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, respectively. At an initial $CO_2$ concentration of $2,000{\mu}mol{\cdot}mol^{-1}$, the canopy photosynthetic rate began to be calculated with $CO_2$ decrement over time. A simple multiplication model expressed by simply multiplying three single-variable models and a modified rectangular hyperbola model were compared. The modified rectangular hyperbola model additionally included photochemical efficiency, carboxylation conductance, and dark respiration which vary with temperature and growth stage. In validation, $R^2$ value was 0.849 in the simple multiplication model, while it increased to 0.861 in the modified rectangular hyperbola model. It was found that the modified rectangular hyperbola model was more suitable than the simple multiplication model in expressing the canopy photosynthetic rates affected by environmental factors (light Intensity and temperature) and growth factor (growth stage) in plant factory modules.

Development of Mono Layer Cell Adsorption Apparatus to Create a Slide for Microscopic Diagnosis (현미경 진단용 슬라이드 제작을 위한 단층세포 흡착장치 개발)

  • Oh, H.Y.;Mun, M.G.;Kim, S.H.;Kim, D.W.;Kang, S.M.;Sung, R.G.;Kim, H.C.
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • This study aims to design a monolayer cell adsorption apparatus that would help to produce high-quality slides for Liquid-Based Cytology (LBC) of an early cancer diagnosis for human bodies. The LBC collects exfoliated cells of human bodies and spreads the cells on the slides. Through processes of dyeing and cytological examination, the LBC screens for cancers in early stage. In this study, both of a cell suction module and a cell adsorption module, which are the key elements of the monolayer cell adsorption apparatus, were developed, and using those modules, the study set, first, conditions to help both GYN and NON-GYN apply principal cells without de-endothelialization before conducting its own analysis on the utility. As a results, for GYN, apparatus was determined to be able to produce high-quality slides under the condition of 4 and for NON-GYN, the apparatus would come up with other slides of high-quality under the condition of 2. The study carried out a repetitive test on selected conditions and proved 96% of the repetitive success rate. By the results of what has been learned so far, the study presents that the apparatus has a possibility to replace device from South Korea as one of those other currently-applied systems to run the LBC and that the system will also present a new paradigm for cancer diagnosis as it makes a contribution to the improvement in the LBC.

Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application (자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구)

  • Yoon, Jong-Ho;Kim, Seok-Ge;Song, Jong-Wha;Lee, Sung-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

Implementation of 5.0GHz Wide Band RF Frequency Synthesizer for USN Sensor Nodes (USN 센서노드용 5.0GHz 광대역 RF 주파수합성기의 구현)

  • Kang, Ho-Yong;Kim, Se-Han;Pyo, Cheol-Sig;Chai, Sang-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.4
    • /
    • pp.32-38
    • /
    • 2011
  • This paper describes implementation of the 5.0GHz RF frequency synthesizer with 0.18${\mu}m$ silicon CMOS technology being used as an application of the IEEE802.15.4 USN sensor node transceiver modules. To get good performance of speed and noise, design of the each module like VCO, prescaler, 1/N divider, fractional divider with ${\Sigma}-{\Delta}$ modulator, and common circuits of the PLL has been optimized. Especially to get excellent performance of high speed and wide tuning range, N-P MOS core structure and 12 step cap banks have been used in design of the VCO. The chip area including pads for testing is $1.1{\times}0.7mm^2$, and the chip area only core for IP in SoC is $1.0{\times}0.4mm^2$. Through analysing of the fabricated frequency synthesizer, we can see that it has wide operation range and excellent frequency characteristics.

Implementation of 1.9GHz RF Frequency Synthesizer for USN Sensor Nodes (USN 센서노드용 1.9GHz RF 주파수합성기의 구현)

  • Kang, Ho-Yong;Kim, Nae-Soo;Chai, Sang-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.5
    • /
    • pp.49-54
    • /
    • 2009
  • This paper describes implementation of the 1.9GHz RF frequency synthesizer with $0.18{\mu}m$ silicon CMOS technology being used as an application of the USN sensor node transceiver modules. To get good performance of speed and noise, design of the each module like VCO, prescaler, 1/N divider, fractional divider with ${\Sigma }-{\Delta}$ modulator, and common circuits of the PLL has been optimized. Especially to get good performance of speed, power consumption, and wide tuning range, N-P MOS core structure has been used in design of the VCO. The chip area including pads for testing is $1.2{\times}0.7mm^2$, and the chip area only core for IP in SoC is $1.1{\times}0.4mm^2$. The test results show that there is no special spurs except -63.06dB of the 6MHz reference spurs in the PLL circuitry. There is good phase noise performance like -116.17dBc/Hz in 1MHz offset frequency.

Design of 5.0GHz Wide Band RF Frequency Synthesizer for USN Sensor Nodes (USN 센서노드용 50GHz 광대역 RF 주파수합성기의 설계)

  • Kang, Ho-Yong;Kim, Nae-Soo;Chai, Sang-Hoon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.6
    • /
    • pp.87-93
    • /
    • 2008
  • This paper describes implementation of the 5.0GHz RF frequency synthesizer with $0.18{\mu}m$ silicon CMOS technology being used as an application of the IEEE802.15.4 USN sensor node transceiver modules. To get good performance of speed and noise, design of the each module like VCO, prescaler, 1/N divider, fractional divider with ${\Sigma}-{\Delta}$ modulator, and common circuits of the PLL has been optimized. Especially to get good performance of speed, power consumption, and wide tuning range, N-P MOS core structure has been used in design of the VCO. The chip area including pads for testing is $1.1*0.7mm^2$, and the chip area only core for IP in SoC is $1.0*0.4mm^2$. Through comparing and analysing of the designed two kind of the frequency synthesizer, we can conclude that if we improve a litter characteristics there is no problem to use their as IPs.

APOLLO2 YEAR 2010

  • Sanchez, Richard;Zmijarevi, Igor;Coste-Delclaux, M.;Masiello, Emiliano;Santandrea, Simone;Martinolli, Emanuele;Villate, Laurence;Schwartz, Nadine;Guler, Nathalie
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.474-499
    • /
    • 2010
  • This paper presents the mostortant developments implemented in the APOLLO2 spectral code since its last general presentation at the 1999 M&C conference in Madrid. APOLLO2 has been provided with new capabilities in the domain of cross section self-shielding, including mixture effects and transfer matrix self-shielding, new or improved flux solvers (CPM for RZ geometry, heterogeneous cells for short MOC and the linear-surface scheme for long MOC), improved acceleration techniques ($DP_1$), that are also applied to thermal and external iterations, and a number of sophisticated modules and tools to help user calculations. The method of characteristics, which took over the collision probability method as the main flux solver of the code, allows for whole core two-dimensional heterogeneous calculations. A flux reconstruction technique leads to fast albeit accurate solutions used for industrial applications. The APOLLO2 code has been integrated (APOLLO2-A) within the $ARCADIA^{(R)}$ reactor code system of AREVA as cross section generator for PWR and BWR fuel assemblies. APOLLO2 is also extensively used by Electricite de France within its reactor calculation chain. A number of numerical examples are presented to illustrate APOLLO2 accuracy by comparison to Monte Carlo reference calculations. Results of the validation program are compared to the measured values on power plants and critical experiments.