• Title/Summary/Keyword: C-DGS

Search Result 29, Processing Time 0.031 seconds

Design of the Microwave Oscillator with the C type DGS Resonator (C형태의 DGS 공진기를 이용한 초고주파 발진기 설계)

  • Kim, Gi-Rae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.4
    • /
    • pp.243-248
    • /
    • 2015
  • Since phase noise is one of the most important parameters in the design of microwave oscillators, several methods have been proposed to reduce the phase noise. These methods have focused on improving the quality factor of resonators, which result in low phase noise oscillators. Dielectric resonators have been widely used for low phase noise in microwave oscillators due to their high quality factor. However this cannot be used in MMIC oscillators because they have a 3D structure. In this paper, to overcome this problem a novel resonator using open ring type DGS is proposed for improvement of phase noise characteristics that is weak point of oscillator using planar type microstrip line resonator, and oscillator for 5.8GHz band is designed using proposed DGS resonator. The open ring type DGS resonator is composed of DGS cell etched on ground plane under $50{\Omega}$ microstrip line. At the fundamental frequency of 5.8GHz, 6.1dBm output power and -82.7 dBc@100kHz phase noise have been measured for oscillator with ring type DGS resonator. The phase noise characteristics of oscillator is improved about 96.5dB compared to one using the general ${\lambda}/4$ microstrip resonator.

A study on the effect to altered geometry of band pass filter with Defected Ground Structure for wireless LAN (DGS를 이용한 WLAN 대역 통과 여파기의 구조변화에 따른 특성 연구)

  • Cho Yeong-Kyun;Kim Hyeong-Seok;Song Hee-Seok;Park Kyu-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.3-6
    • /
    • 2003
  • Effect to altered geometry of a suggested defected ground structure(DGS) unit cell was investigated . And equivalent circuit model was extracted from the DGS unit cell A microstrip band Pass filter with DGS has been designed in this Paper. The BPF with DGS was fabricated and obtained experimental results with network analyzer HP8510C. Experimental results show the center frequency of 2.45GHz, the insertion loss of 0.85dB, and the 3-dB bandwidth of 470MHz (19.5%). The center frequency of BPF is 2.4GHz which is available for wireless LAN.

  • PDF

Transformerless DGS Control using a Z-source Boost Inverter (Z-원 승압인버터를 이용한 변압기 없는 DGS제어)

  • Park Young-San
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.9
    • /
    • pp.1617-1624
    • /
    • 2006
  • This paper presents system modeling, modified space vector PWM implementation and design of a closed loop controller of the Z-source inverter which consists of L and C components and shoot-through zero vectors for DGS. Zero vector periods of SVPWM utilized to boost DC-link voltage instead of conventional DC/DC converter and transformer. Only two shoot-through vut(nn are used for DC link voltage control during one switching period without loss of non-zero vectors. Discrete time sliding mode controller, robust servomechanism controller are designed to realize fast and no-overshoot current response and a steady state voltage error. Simulation results are shows the effectiveness of the proposed algorithm.

A Method to Reduce the Size of Amplifiers using Defected Ground Structure (결합된 접지 구조를 이용한 증폭기의 소형화 방법)

  • Lim, Jong-Sik;Park, Jun-Seok;Kim, Chul-Soo;Lee, Young-Tak;Ahn, Dal;Nam, Sang-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.5
    • /
    • pp.436-444
    • /
    • 2002
  • This paper presents a new method, which uses defected ground structure (DGS) on the ground planes of planar transmission lines such as microstrip and coplanar waveguide (CPW), to reduce the size of amplifiers. The main idea can be summarized as follow; DGS on the ground plane of microstrip or CPW line shows an increased slow-wave effect due to the additional equivalent L-C components. So the electrical length of the transmission line with DGS is longer than that of the standard transmission line for the same physical length. Then, the length of the transmission line with DGS can be shortened in order to maintain the original electrical length to be the same. This leads the matching of the original amplifier to be kept. In order to show the proposed method is valid, two kinds of amplifiers, the original amplifier and reduced amplifier, are fabricated, measured, and compared using both microstrip and CPW. The measured performances of the reduced amplifiers with DGS are quite similar to the ones of the original amplifiers for both microstrip and CPW amplifiers, even though the size of matching networks of the amplifiers with DGS are much smaller than those of the original amplifiers.

A Design of 5.8 ㎓ Oscillator using the Novel Defected Ground Structure

  • Joung, Myoung-Sub;Park, Jun-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.2
    • /
    • pp.118-125
    • /
    • 2003
  • This paper presents a 5.8-㎓ oscillator that uses a novel defected ground structure(DGS), which is etched on the metallic ground plane. As the suggested defected ground structure is the structure for mounting an active device, it is the roles of a feedback loop inducing a negative resistance as well as a frequency-selective circuit. Applying the feedback loop between the drain and the gate of a FET device produces precise phase conversion in the feedback loop. The equivalent circuit parameters of the DGS are extracted by using a three-dimensional EM simulation ,md simple circuit analysis method. In order to demonstrate a new DGS oscillator, we designed the oscillator at 5.8-㎓. The experimental results show 4.17 ㏈m output power with over 22 % dc-to-RF power efficiency and - 85.8 ㏈c/Hz phase noise at 100 KHz offset from the fundamental carrier at 5.81 ㎓.

Control of Z-Source MSVPWM Inverter for DGS (DGS용 Z-원 MSVPWM 인버터 제어)

  • Park, Young-San;Bae, Cherl-O;Nam, Taek-Kun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.277-278
    • /
    • 2006
  • This paper presents circuit models and control algorithms of distributed generation system(DGS) which consists of Z-type converter and PWM inverter Z-type converter which employs both the L and C passive components and shoot-through zero vectors instead of the conventional DC/DC converter in order to step up DC-link voltage. Discrete time sliding mode control with the asymptotic observer is used for current control.

  • PDF

Design of High Efficiency Power Amplifier Using Adaptive Bias Technique and DGS (적응형 바이어스기법과 DGS를 이용한 고효율 전력증폭기설계)

  • Oh, Chung-Gyun;Son, Sung-Chan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.403-408
    • /
    • 2008
  • In this paper, the high efficiency and linearity Doherty power amplifier using DGS and adaptive bias technique has been designed and realized for 2.3GHz WiBro applications. The Doherty amplifier has been implemented us-ing silicon MRF 281 LDMOS FET. The RF performances of the Doherty power amplifier (a combination of a class AB carrier amplifier and a bias-tuned class C peaking amplifier) have been compared with those of a class AB amplifier alone, and conventional Doherty amplifier. The Maximum PAE of designed Doherty power amplifier with DGS and adaptive bias technique has been 36.6% at 34.01dBm output power. The proposed Doherty power amplifier showed an improvement 1dB at output power and 7.6% PAE than a class AB amplifier alone.

  • PDF

The Advanced Voltage Regulation Method for ULTC in Distribution Systems with DG

  • Kim, Mi-Young;Song, Yong-Un;Kim, Kyung-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.737-743
    • /
    • 2013
  • The small-scaled onsite generators such as photovoltaic power, wind power, biomass and fuel cell belong to decarbonization techniques. In general, these generators tend to be connected to utility systems, and they are called distributed generations (DGs) compared with conventional centralized power plants. However, DGs may impact on stabilization of utility systems, which gets utility into trouble. In order to reduce utility's burdens (e.g., investment for facilities reinforcement) and accelerate DG introduction, the advanced operation algorithms under the existing utility systems are urgently needed. This paper presents the advanced voltage regulation method in power systems since the sending voltage of voltage regulators has been played a decisive role restricting maximum installable DG capacity (MaxC_DG). For the proposed voltage regulation method, the difference from existing voltage regulation method is explained and the detailed concept is introduced in this paper. MaxC_DG estimation through case studies based on Korean model network verifies the superiority of the proposed method.

Frequency Adjustable Dual Composite Right/Left Handed Transmission Lines (주파수 가변성을 갖는 D-CRLH 전송 선로)

  • Lim, Jong-Sik;Koo, Ja-Kyung;Han, Sang-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.12
    • /
    • pp.1375-1382
    • /
    • 2008
  • Frequency adjustable D-CRLH(dual-composite right/left handed) transmission lines, which solve the problem of design complexity and uncontrolled frequency of the existing structures, are proposed in this paper. The first design(type I), consisting of defected ground structure(DGS), island pattern in DGS, fixed stub and varactor diodes, controls $C_L$ in the parallel resonant circuit, while the second structure(type 2) composed of fixed DGS, shunt stub and diode adjusts $C_R$ in the series resonant circuit. The dual band frequency points which correspond to the meaningful electrical length of +/-90 degree in the RH/LH region are adjustable according to the bias voltage. The measurement shows that the LH frequency point which has -90 degree of electrical length are adjusted over $4.22{\sim}5.39\;GHz$ and $4.21{\sim}5.05\;GHz$ for type 1 and type 2, respectively, under $1{\sim}12\;V$ of bias voltage. In addition, the frequency Woo where RH turns over LH is controled over $3.26{\sim}4.22\;GHz$ for type 2 with the same bias condition.

DP Formulation of Microgrid Operation with Heat and Electricity Constraints

  • Nguyen, Minh Y;Choi, Nack-Hyun;Yoon, Yong-Tae
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.919-928
    • /
    • 2009
  • Microgrids (MGs) are typically comprised of distributed generators (DGs) including renewable energy sources (RESs), storage devices and controllable loads, which can operate in either interconnected or isolated mode from the main distribution grid. This paper introduces a novel dynamic programming (DP) approach to MG optimization which takes into consideration the coordination of energy supply in terms of heat and electricity. The DP method has been applied successfully to several cases in power system operations. In this paper, a special emphasis is placed on the uncontrollability of RESs, the constraints of DGs, and the application of demand response (DR) programs such as directed load control (DLC), interruptible/curtaillable (I/C) service, and/or demand-side bidding (DSB) in the deregulated market. Finally, in order to illustrate the optimization results, this approach is applied to a couple of examples of MGs in a certain configuration. The results also show the maximum profit that can be achieved.