• 제목/요약/키워드: C-24 configuration

검색결과 45건 처리시간 0.03초

Cgd 성분을 포함한 공정별 주요 잡음원 천이 과정 연구 (The transition of dominant noise source for different CMOS process with Cgd consideration)

  • Koo, Minsuk
    • 한국정보통신학회논문지
    • /
    • 제24권5호
    • /
    • pp.682-685
    • /
    • 2020
  • In this paper, we analyze the dominant noise source of conventional inductively degenerated common-source (CS) cascode low noise amplifier (LNA) when width and gate length of stacked transistors vary. Analytical MOSFET and its noise model are used to estimate the contributions of noise sources. All parameters are based on measured data of 60nm, 90nm and 130nm CMOS devices. Based on the noise analysis for different frequencies and device parameters including process nodes, the dominant noise source can be analyzed to optimize noise figure on the configuration. We verified analytically that the intuctively degenerated CS topology can not sustain its benefits in noise above a certain operation frequency of LNA over different process nodes.

Low Spurious Image Rejection Mixer for K-band Applications

  • Lee, Moon-Que;Ryu, Keun-Kwan;Kim, Hyeong-Seok
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권6호
    • /
    • pp.272-275
    • /
    • 2004
  • A balanced single side-band (SSB) mixer employing a sub-harmonic configuration is designed for up and down conversions in K-band. The designed mixer uses anti-parallel diode (APD) pairs to effectively eliminate even harmonics of the local oscillator (LO) spurious signal. To reduce the odd harmonics of LO at the RF port, we employ a balanced configuration for LO. The fabricated chip shows 12$\pm$2dB of conversion loss and image-rejection ratio of about 20dB for down conversion at RF frequencies of 24-27.5GHz. As an up-conversion mode, the designed chip shows 12dB of conversion loss and image-rejection ratio of 20 ~ 25 dB at RF frequencies of 25 to 27GHz. The odd harmonics of the LO are measured below -37dBc.

젊은 한국인 남성의 유두 유륜 복합체의 모양과 위치 (The Configuration and Location of the Nipple-Areola Complex of Young Korean Adult)

  • 윤상엽;심형보
    • Archives of Plastic Surgery
    • /
    • 제32권6호
    • /
    • pp.706-709
    • /
    • 2005
  • The absence of the nipple-areolar complex(NAC) in men are seldom stated, as a result of trauma, burn, mastectomy, or after the correction of extreme bilateral gynecomastia. A total of 50 healthy men aged 21 to 27 years were examined. We recorded the configuration (dimensions and shape) and the location of the NAC with respect to fixed skeletal anatomic landmarks. Of the 50 subjects examined, 44 had oval and 6 had a round NAC. The mean diameter for a round NAC was 24.3 mm. The center of the NAC was in the fourth intercostal space in 41 volunteers and in the fifth intercostal space in 9 of the subjects. To localize the NAC on the chest wall, at least three reproducible measurements proved to be necessary, composed of a horizontal line(distance from the midsternal line to the nipple, A), a medial oblique line(distance from the sternal notch to the nipple, B) and a lateral oblique line(distance from the acromioclavicular joint to the nipple, C). Using these three parameters, we recommend that the appropriate location can be calculated derived from the circumference of the chest.

The loss coefficient for fluctuating flow through a dominant opening in a building

  • Xu, Haiwei;Yu, Shice;Lou, Wenjuan
    • Wind and Structures
    • /
    • 제24권1호
    • /
    • pp.79-93
    • /
    • 2017
  • Wind-induced fluctuating internal pressures in a building with a dominant opening can be described by a second-order non-linear differential equation. However, the accuracy and efficiency of the governing equation in predicting internal pressure fluctuations depend upon two ill-defined parameters: inertial coefficient $C_I$ and loss coefficient $C_L$, since $C_I$ determines the un-damped oscillation frequency of an air slug at the opening, while $C_L$ controls the decay ratio of the fluctuating internal pressure. This study particularly focused on the value of loss coefficient and its influence factors including: opening configuration and location, internal volumes, as well as wind speed and approaching flow turbulence. A simplified formula was presented to predict loss coefficient, therefore an approximate relationship between the standard deviation of internal and external pressures can be estimated using Vickery's approach. The study shows that the loss coefficient governs the peak response of the internal pressure spectrum which, in turn, will directly influence the standard deviation of the fluctuating internal pressure. The approaching flow characteristic and opening location have a remarkable effect on the parameter $C_L$.

침적 Lance를 이용한 가스 injection시 ladle내 액체의 교반특성 연구 (The Mixing Characteristics of Melt during the Injection of Gas into a Ladle through an Immersed Lance)

  • 박현서
    • 자원리싸이클링
    • /
    • 제11권3호
    • /
    • pp.17-24
    • /
    • 2002
  • There has been an increasing demand over the years for steels with lower[s] content. For the purpose of improving the efficiency of desulphrization in the powder injection process of ladle, experimental studies were carried out by using cold model to optimize the lance configuration, gas flow rate, immersion depth of lance nozzle, position of lance nozzle relative to the ladle and the effect with slag, etc. As the results of this study, it was made clear that 2-hole nozzle lance (C, E type) placed in an asymmetric position gives the shortest mixing times.

A New 5α, 8α-Epidioxy Sterol from the Marine Sponge Plakortis simplex

  • Oh, Jung-Soon;Kim, Myoung-Ha;Song, Ah-Rin;Rho, Jung-Rae
    • 한국자기공명학회논문지
    • /
    • 제14권1호
    • /
    • pp.1-8
    • /
    • 2010
  • Four 5,8-epidioxy sterols were isolated from the marine sponge Plakortis simplex. Their structures were completely determined by an extensive NMR analysis and comparison with NMR data of similar compounds for absolute stereochemistry of the side chain. The compounds were assigned as 5,8-epidioxy- (24S)-ethylcholesta-6,22(E),25-trien-3-ol(1), 5,8-epidioxy-(24S)-methylcholesta- 6,22(E)-dien-3-ol(2), 5,8-epidioxycholesta-6,22(E)-dien-3-ol(3) and 5,8- epidioxycholesta-6-en-3-ol (4).

법랑질 변연으로 이루어진 복합레진 수복물의 체적과 C-factor가 미세누출에 미치는 영향 (THE EFFECT OF C-FACTOR AND VOLUME ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS WITH ENAMEL MARGINS)

  • 구봉주;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제31권6호
    • /
    • pp.452-459
    • /
    • 2006
  • 와동벽과 복합레진 수복물이 접착될 때, 복합레진의 치질에 대한 접착력과 레진 자체의 중합 시 발생하는 수축응력이 상충하게 된다. 이러한 수축응력의 크기는 와동의 형태요소 (C-factor)와 수복물의 체적에 영향을 받는다. 이에 본 실험에서는 단일 병 접착제를 사용한 복합레진 수복 시 법랑질 변연만으로 이루어진 와동의 C-factor와 체적이 미세누출에 미치는 영향을 미세 전류 측정법을 이용하여 정량적으로 분석하고 평가하였다. 연마기를 이용하여 40개의 건전한 우치 협면에 편평한 법랑질 표면을 형성하였다. 각각 10개의 치아에 원통형 와동을 형성하였으며, 와동의 깊이와 직경에 따라 4개 군으로 분류하였다 ( I군: 1.5 mm ${\times}$ 2.0 mm, II군: 1.5 mm ${\times}$ 6.0 mm, III군: 2.0 mm ${\times}$ 1.72 mm, IV군: 2.0 mm ${\times}$ 5.23 mm). 각기 와동의 C-factor는 4, 5.62, 2, 2.54를 보였다. 산 부식 후 단일 병 접착제인 BC Plus$^{TM}$ (Vericom, Korea)를 제조사의 지시에 따라 적용하고, 미세혼합형 복합레진인 Denfil$^{TM}$(Vericom)을 충전하였다. 40초씩 광중합 후 치아를 실온에서 증류수에 24시간 동안 보관한 다음, Sof-Lex system을 이용하여 연마하였고, 5$^{\circ}$C와 55$^{\circ}$C범위에서 500회 열순환을 시행하였다. 이후 미세전류 측정을 위해 치수강 내에 증류수를 채우고 치근단공을 통해 0.018 stainless wire를 삽입한 후 sticky wax로 근첨부를 밀봉하였으며, nail varnish를 수복물의 변연에서 1 mm를 제외한 전체 치면에 2회 도포하였다. 미세누출의 측정은 전기 화학적 방법을 이용하여 측정하였으며, 통계적 유의성은 95% 유의 수준의 Two-way ANOVA로 검증하여 , 다음과 같은 결과를 얻었다. 1. 복합레진 수복물의 체적이 적은 것이 큰 것에 비해 미세누출도가 적었으나, 통계학적으로 유의한 차이는 없었다. 2. 와동 형태와 연관된 C-factor는 복합레진 수복물의 미세누출도에 영향을 주지 않았다. 법랑질 변연을 갖는 와동에 단일 병 접착제를 사용한 본 실험에서는 복합레진의 중합 시 발생하는 수축응력에 영향을 미치는 것으로 알려진 수복물의 체적과 C-factor가 미세누출도에 영향을 주지 못하였다. 이는 법랑질과 접착시스템과의 강력한 접착력에 기인한 것으로 보이며, 앞으로 이에 대한 더 많은 연구가 필요할 것으로 사료된다.

RFSoC의 양성자 시험 로직 개발 및 SEU 측정 평가 (Development of proton test logic of RFSoC and Evaluation of SEU measurement)

  • 윤승찬;이주영;김현철;유경덕
    • 한국인터넷방송통신학회논문지
    • /
    • 제24권1호
    • /
    • pp.97-101
    • /
    • 2024
  • 본 논문에서는 Xilinx 사의 RFSoC FPGA에 대해 양성자 빔 조사 시험 로직 구현과 시험 결과를 제시한다. RFSoC는 FPGA 기능 외에도 CPU, ADC, DAC가 집적화되어 있는 칩으로 소형경량화를 목적으로 둔 방위산업 및 우주 산업에서 주목받고 있는 칩이다. 이러한 칩을 우주 환경에서 사용하려면 방사선 영향에 대한 분석이 필요하며 방사선 경감 대책이 필요하게 되었다. 양성자 조사 시험을 통해 RFSoC의 방사선 영향을 측정할 수 있는 로직을 설계하였다. Memory에 저장된 값을 정상 값과 비교하는 로직을 구현하고 RFSoC에 양성자를 조사하여 Block memory 영역에서 발생하는 SEU를 측정하였다. 다른 영역에서의 SEU 발생을 완화하기 위해 TMR, SEM을 적용하여 설계하였다. 시험 결과를 통해 본 시험 구성에 대해 검증하고 향후 위성용 로직 설계를 검증할 수 있는 환경을 구축하고자 한다.

Preliminary investigation of Ic homogeneity along the longitudinal direction of YBCO coated conductor tape under tensile loading

  • Dizon, J.R.C.;Oh, S.S.;Sim, K.D.;Shin, H.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.24-28
    • /
    • 2013
  • In this study, the homogeneity of critical current, $I_c$, along the lengthwise direction in the coated conductor (CC) tape under uniaxial tension was investigated using a multiple voltage tap configuration. Initially, a gradual and homogeneous $I_c$ degradation occurred in all subsections of the tape up to a certain strain value. This was followed by an abrupt $I_c$ degradation in some subsections, which caused scattering in $I_c$ values along the length with increasing tension strain. The $I_c$ degradation behaviour was also explained through n-value as well as microstructure analyses. Subsections showed $I_c$ scattering corresponding to damaged areas of the CC tape revealed that transverse cracks were distributed throughout the gauge length. This homogeneous $I_c$ degradation behaviour under tension is similar with the case under torsion strain but different with the case under hard bending which were previously reported. This behaviour is also different with the case using Bi-2223 HTS tapes under tension strain.

국소의치용 티타늄 합금의 부식 특성 (Corrosion Characteristics of Ti alloy for Removable Partial Denture)

  • 김정재;김원기
    • 한국콘텐츠학회논문지
    • /
    • 제14권4호
    • /
    • pp.237-242
    • /
    • 2014
  • 본 연구의 목적은 저탄성계수 Ti-30Ta 합금에 Zr 원소를 첨가하여 표면 특성 및 부식 거동을 조사하였다. 저탄성계수 Ti-30Ta-xZr(x : 3, 7, 15 wt %)합금은 아크 멜팅기로 제조하였고, 아르곤 분위기에서 $1000^{\circ}C$ 24시간 동안 열처리하였다. 합금의 미세구조는 FE-SEM 그리고 XRD를 이용하여 조사하였다. 전기화학적 특성은 시편 작업전극, 고밀도 탄소 보조전극 그리고 포화칼로멜 기준전극의 통상적인 3상을 이용하여 수행하였다. Ti-30Ta-xZr 합금의 분극 거동 결과, 균질화 처리된 Ti-30Ta-15Zr 합금의 부동태 전류밀도가 다른 합금에 비해 낮았다.