• Title/Summary/Keyword: Building Material

Search Result 2,846, Processing Time 0.029 seconds

A Basic Study of Production Management of Free-form Concrete Panels (비정형 콘크리트 패널의 생산관리 기초연구)

  • Son, Seung-Hyun;Lim, Jee-Young;Na, Young-Ju;Kim, Sun-Kuk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.33-34
    • /
    • 2018
  • Currently, free-form building has been increased worldwide. However, as a finishing material of free-form building, the production of free-form concrete panels(FCPs) spends lots of cost and efforts since it is difficult to reuse the FCP formwork and lots of workers are needed to make free-form curve. In addition, the technology to produce the FCP economically and easily is insufficient. Therefore, the objective of this study is a basic study regarding production management for developing free-form concrete panels. To achieve the objective, the property of FCP and condition for effective production management and production process are analyzed. The results of this study can utilize to develop the algorithm for FCP production management.

  • PDF

An Experimental Study on the Compressive Strength of Cement Mortar mixing Anion Exchange Resin (음이온교환수지 혼입 시멘트 모르타르의 압축강도에 관한 실험적 연구)

  • Jeong, Do-Hyun;Lee, Yun-Su;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.54-55
    • /
    • 2018
  • Reinforced concrete is a building material that is generally used in modern society. Securing the performance of reinforced concrete is directly connected to the durability and longevity of the building. One of the major factors that deteriorate the durability of concrete is harmful ion. Recently, the quality and improvement method of reinforced concrete for penetration of harmful ion has been studied. In this study, the bead type ion exchange resin is substituted for 0%, 3%, and 6% of the fine aggregate volume in the mortar. The speciments underwent underwater curing and were checked for compressive strengths of 3 days and 28 days. From the results of compressive strength, it can be seen that the higher the substitution ratio of the ion exchange resin, the lower the early strength and long-term strength development, especially the early strength development.

  • PDF

Evaluating high performance steel tube-framed diagrid for high-rise buildings

  • Lee, Dongkyu;Ha, Taehyu;Jung, Miyoung;Kim, Jinho
    • Steel and Composite Structures
    • /
    • v.16 no.3
    • /
    • pp.289-303
    • /
    • 2014
  • In recent, development of construction and design technology gives taller, larger and heavier steel framed structures. With the tendency of increasing high-rise building, this study is strongly related to structural system, one of significant components in structural design. This study presents an innovative structural system, with high performance steel material, diagrid. Its detail, structural analysis, and structural experiments are all included for the development of new structures.

A Basic Study of Legal Standards for Building Health Performance (건축물의 건강성능에 관한 법적 기준의 기초연구)

  • Lee, Hyun-Min;Ryu, Sang-Yeon;Kim, Sun-Kuk
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.19-26
    • /
    • 2009
  • In modern architecture, the air-tight construction aimed at saving the energy rather causes ventilation problems and the artificial materials for cost reduction worsen the residential quality. To deal with such negative effect, the study on evaluating the health performance becomes increasingly critical. Among the various factors such as design quality, selected material, construction method and mechanical system that shall be subject to evaluation to identify the health performance of the building, the study was aimed at investigating the legal standards associated with healthy building in various countries. Such evaluation items will provide inputs for an attempt to build legal criteria for a building health performance rating system in Korea.

Analysis of Construction RCB Exterior Wall Formwork Placing High on Nuclear Power Plant (원자력 발전소 RCB 외벽 거푸집 1단 타설 높이별 시공성 분석)

  • Song, Hyo-Min;Shin, Yoon-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.205-206
    • /
    • 2014
  • It is very important to reduce the construction duration of the Reactor Containment Building (RCB) when considering the more than 50 months on average from concrete placement to completion. The purpose of this study attempts to evaluate the single-stage workability of the system given a change in the height of the setting of RCB exterior wall formwork to be used in nuclear power plant construction. As a result of this study, it is possible height of 3.5m~4m uses formwork when analyzing the construction period and material costs an increase in formwork by concrete lateral pressure, to ensure the workability of the RCB exterior wall formwork. Through this study, I want to provide as basic data for the improvement of workability and RCB shortening the construction period.

  • PDF

A study on the construction technology for major building material to reduce indoor air pollution (실내오염물질방출저감을 위한 주요건축자재의 시공기술에 관한 연구)

  • Heo, Jung-Yong;Choi, Chang-Ho;Ann, Hyung-June;Lee, Yun-Gyu
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.143-148
    • /
    • 2007
  • Recently indoor air pollution caused by exposing hazardous chemicals (VOCs, formaldehyde) due to undiscriminated use of new construction materials and air-tightness to save energy is becoming a big issue. We have developed technologies to estimate the amounts of contaminants from constructions materials and method. We have further developed construction technologies to reduce and characterize these contaminants. The developed technologies were then refined to eliminate defects through considering field applicability.

  • PDF

A Study on the Establishment and Construction Work of Bungang Seowon (안동 분강서원의 창원 및 조영(造營)에 관한 연구)

  • Lee, Ho-Yeo
    • Journal of architectural history
    • /
    • v.29 no.1
    • /
    • pp.7-20
    • /
    • 2020
  • This paper is a review of the construction process, craftsmanship, architectural economy of Bungang Seowon through the Changwon Ilgi(diary). The Bungang Seowon, which was built in the early 18th century, was initially built as a shrine, but was later completed as a seowon upon the decision of the scholars. It was the descendants of Nongam and the Hyanggyo, Seowon, and the government offices that provided economic, human and material support to the construction of Seowon. The small building of Bungang Seowon was run by a civilian carpenter, while the large building was run by a monk carpenter. The mobilization of the building workers was done by local scholars assigning the number of workers needed for each village.

A Study on the Major Building Material and Construction Method Influencing to IAQ through Full-Scale House Construction (실물 주거 시공을 통한 실내공기질에 영향을 미치는 주요 건축자재 및 시공방법에 관한 연구)

  • Yu Hyung-Ku;Park Jin-Chul;Rhee Eon-Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.3
    • /
    • pp.262-269
    • /
    • 2006
  • Formaldehyde and total volatile organic compounds (TVOC) from building materials have been known as main causes of IAQ problem in Newly-Constructed Multi-Family Houses. Because Multi-Family Houses are built in large quantities in a similar manner, inappropriate selection of building materials and method will detrimental affect IAQ. This research aims to identify major causes of Indoor Air Pollutants in Multi-Family Houses, by constructing Mock-Up & One-Room House. As a result, self leveling concrete, door, and furniture construction is a major cause of indoor formaldehyde increase, and tile bond is TVOC, and urethane water proof is Etylbenzene, and Xylene.

The Output Characteristics of 3kW BIPV System (3kW 건물일체형 태양광발전시스템의 출력특성)

  • Kim, Ji-Hoon;Kim, Pyouug-Ho;Lim, Yang-Su;Cho, Geum-Bae;Baek, Hyung-Lae;Oh, Geum-Gon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.471-474
    • /
    • 2006
  • BIPV(Building Integrated PV) system can expect dual effects that reduce expenses for establishment of PV system by adding new function as outer covering material of building expect producing the electricity. But, there are many generation differences according to the exterior environmental facts(solar cell away, design and installation condition of interactive inverter system) Therefore, it is difficult to optimum design. Consequently in advance design system, we experiment 3kW BIPV(Building Integrated PV) generation. We concrete PV system efficient application of variable. BIPV system that is proposed in this paper, was established in Solar Energy research center of Chosun University, composed with system. This research is a basic study for application of building integrated photovoltaic system for builing.

  • PDF

A DEVELOPMENT OF MODEL FOR FIRE HAZARD ASSESSMENTS H THE BUILDINGS

  • Lee, Su-Kyung;Kim, Su-Tae;Ha, Dong-Myung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.384-391
    • /
    • 1997
  • The hazard assessment in which the potential hazard factors In the buildings are investigated and the scale of the hazard is analyzed should be performed first in order to prevent personal and material damages due to building fire. In this study, the building fire hazard are assessed using 822-item checklist, for the qualitative evaluation of which the main factors are classified into 10 items, yielding 100 scale points with some weighting. It is shown that present model is applicable for the assessment of all general buildings through the examination of the suitability of assessment model by actual assessment of existing building. Also, the checklist is prepared in itemized questionnaire form for easy assessment of building fire hazard. Therefore, the present model will be helpful for those working in fire prevention, who are suffering from the lack of manifest evaluation model for the fire prevention assessment so far in Korea.

  • PDF