• Title/Summary/Keyword: Building Lighting

Search Result 311, Processing Time 0.032 seconds

Performance Analysis of Electricity Demand Forecasting by Detail Level of Building Energy Models Based on the Measured Submetering Electricity Data (서브미터링 전력데이터 기반 건물에너지모델의 입력수준별 전력수요 예측 성능분석)

  • Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.627-640
    • /
    • 2018
  • Submetering electricity consumption data enables more detail input of end use components, such as lighting, plug, HVAC, and occupancy in building energy modeling. However, such an modeling efforts and results are rarely tried and published in terms of the estimation accuracy of electricity demand. In this research, actual submetering data obtained from a university building is analyzed and provided for building energy modeling practice. As alternative modeling cases, conventional modeling method (Case-1), using reference schedule per building usage, and main metering data based modeling method (Case-2) are established. Detail efforts are added to derive prototypical schedules from the metered data by introducing variability index. The simulation results revealed that Case-1 showed the largest error as we can expect. And Case-2 showed comparative error relative to Case-3 in terms of total electricity estimation. But Case-2 showed about two times larger error in CV (RMSE) in lighting energy demand due to lack of End Use consumption information.

A Study on the Limit Analysis of the LED Lighting Subsidy Program Considering the Perspective of Individual Building Clients (건축주 입장을 고려한 LED조명 프로그램의 한계 분석 연구)

  • Hwang, Sung-Wook;Park, Jung-Sung;Chae, Woo-Kyu;Lee, Hak-Ju;Song, Il-Keun;Kim, Jung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.18-25
    • /
    • 2013
  • Various DSM (Demand Side Management) programs have been developed and carried out to use the limited energy resources of human-beings reasonably. LED lighting is one of essential DSM programs and the development of technologies is ongoing vigorously. Recently, one-person households have been increased and the electricity consumption pattern is different with conventional households because residents live as a single. On the other hand, owners of the one-person households tend to not prefer to install high efficient appliances due to the cost increasement. Therefore, the existing DSM subsidy programs should be revaluated so that the owners decide to install high efficient appliances.

Analysis of Saving Rates according to Energy Consumption Factors in Office Building (사무소 건물의 에너지 소비 요소별 절감률 분석)

  • Park, Byung-Il;Yang, In-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.115-122
    • /
    • 2016
  • In this study, 21 energy reduction factors were selected as architecture, system & operation, and lighting and equipment parts to analyze reduction method of the load occurring in office buildings. Energy consumption simulation was performed. In the architecture part, saving rate (1.53%) of "occupant density" factor was the most efficient. In the system and operation part, saving rate (1.28%) of "interior VAV and exterior FPU type" factor was the most efficient. In case of lighting and equipment part, saving rate (12.42%) of "schedule" factor was the most efficient. In the three parts, saving rate of the lighting and equipment part was 27.32%. This was caused by the "schedule" factor. Saving rates of the architecture part and the system and operation part were 3.39% and 1.20%, respectively.

Spectral Analysis of Sunlight Collector System (태양광 채광시스템의 스펙트럼 분석)

  • 박준석;어익수;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.80-84
    • /
    • 1999
  • Sunlight Collector System is a new way to make sunlight available to living things. It transmits sunlight through fiber optics to wherever is needs. It applies the artificial lighting, underground lighting, intelligent building, museum lighting, restoration-room to health etc. Cutting out most of the ultra-violet and intra-red radiation. In this paper, we measured the spectrum analysis of sunlight and Sunlight collector System's light. Also, we found out the distance to get visible light.

  • PDF

An Analysis of Daylighting in Each Space of Apartment Houses (공동주택의 공간별 채광실태에 관한 연구)

  • Hwang, Min Ku;Shin, Hae Mi
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.43-48
    • /
    • 2008
  • One of the most important factors in determining the quality of living environment is daylighting. Especially its influence in the psychological and biological life of human beings cannot be underestimated. Therefore, lots of researches have been given to develop a more efficient daylighting system. The sunlighting system, one of many developed systems, has been developed and applied in various ways. However, the high cost of sunlighting system has been the most difficult stumbling-block in making it commercial. However, as domestic apartment houses tend to be more luxury, life environment becomes a very important factor more than cost in building apartment house. Therefore, it would be possible to adopt sunlighting system in the non-window areas such as a restroom in an apartment house. This research is a preliminary work in order to measure a possibility of applying sunlighting system in an apartment house. In order to do so, I measure Sunlight Illuminance Ratio in various areas of apartment house. As a result, in case of a residential-commercial building, areas such as kitchen, restroom, and entrance are relatively weak-lighting areas. In case of a traditional apartment house, restroom and entrance are relatively weak-lighting areas. For that reason, a special lighting support is needed in these areas.

Feasibility Study on Retrofitting Lighting and Heat Source Equipments in Office Buildings (사무소건물 조명기기와 열원기기의 고효율기기로의 교체에 관한 경제성 검토)

  • Lee, Chul-goo;Kim, Jong-dae;Im, Tae-soon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.2
    • /
    • pp.13-18
    • /
    • 2016
  • Energy saving has been main concern, thus government supporting policies which are based on Fundamentals of Low-carbon Green Growth Act', 'Green Building Support Act, have been prepared in Korea. The objective of this study is to estimate energy conservation effectiveness and economic advantage assuming that lighting equipments and heat source equipments would be retrofitted. Office building, which has total floor area of $30,000m^2$, was a subject of this study. From the estimations, electric rate will be decreased by 62,886,000 won per year due to lighting equipments retrofit, and gas rate will be decreased 11,141,000 won or 17,332,000 won per year due to heat source equipments retrofit (in case of COP 1.2 or 1.5). Payback period of each case that are calculated by energy saving cost and retrofit cost are estimated 27.9 year, 38.6 year and 29.2 year, thus economic supporting policies is necessary for effective energy saving in buildings. Meanwhile payback period of heat source equipment for new building is estimated 6.1 year and 8.3 year.

A CO2 Emission Reduction Method through Correlation Analysis of Design Parameters in Buildings (건축물 설계변수의 상관관계 분석을 통한 CO2 배출저감 방안)

  • Lee, Hyun-Woo;Chae, Min-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.100-106
    • /
    • 2011
  • This study proposes a $CO_2$ emission reduction method through correlation analysis of a sample building. First, energy saving factors of heating, cooling, lighting were determined for the correlation analysis and $CO_2$ emission contribution rate of the design parameters have been analyzed. Then optimal combination of each design parameter has been drawn. Heat transfer coefficient of walls and windows, air permeability, windows area ratio, and shading devices were selected as applicable energy saving factors of the sample building. Also computer simulation was conducted using experimental design by Orthogonal Arrays of the statistical method. And the contribution rate was estimated by Analysis of Variance-ANOVA. As a result, the $CO_2$ emission in heating was reduced to 51.9%; in cooling to 16.8%; and in lighting to 2% compared to the existing building. The majority of the reduction was presented by heating energy.

Energy Efficient LED Lighting Design to utilize the Sun Light (태양광 활용을 위한 효율적 LED 조명기구 설계 방안)

  • Jeong, Hak-Geun;Han, Soo-Bin;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.31-36
    • /
    • 2011
  • LED is expected as an environmentally friendly next generation light source with its good reliability and long lifetime. The light sources for illumination have a variety of applications in the indoor and outdoor, and the variation of optical power and color rendering of the light source limits their applications. Therefore, it is necessary to research the LED lamp and its luminaire to minimize the variation of dynamic characteristics and to improve the color rendering due to that illuminating environment. Daylight is very good light source to human and can be used as primary or a secondary light source with benefits of energy, productivity and health.This paper presents the design method of LED lighting system to improve poor property in terms of CR(color redering) characteristic to use daylight effectively.

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

A Study on the Status of Illumination Environment in Workplaces (업무공간의 조명 환경 실태 조사 연구)

  • Choi Han-Hee;Ha Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.6
    • /
    • pp.167-174
    • /
    • 2004
  • The purpose of this study is to examinethe present illumination conditions in office environment and to suggest an efficient illumination plan in office planning process. Illumination conditions in work environment were surveyed in 6 offices to investigate whether the present illumination conditions were appropriate to the work type. The results of this study are as follows: Most of the general Illuminance level in the area of work were all at an adequate level, except one. The average Illuminance level in the all meeting rooms were met for the standard. Illuminance in the all reception area were extremely over the standard, The illuminations of this area were rather designed according to the image of the company than the standard. As for the illumination method in the area of general work, four offices used a general lighting by a direct lighting type, while two offices used a general lighting and a task lighting at the same time. This survey suggested that first, each company should consider illumination plan in the building planning process, second, illumination plan considering the type of places is needed, and third, illumination environment may be differentiated according to the work type. In conclusion, efficient illumination environment should be considered in office building planning process, especially In terms of illumination materials and methods.