• 제목/요약/키워드: Building Integrated System

검색결과 824건 처리시간 0.028초

건물일체형 태양광발전 시스템 성능평가 프로그램 개발 (The Development of Performance Evaluation Program of Building Integrated Photovoltaic System)

  • 김법전;박재완;윤종호;신우철
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: In design and planning Building Integrated Photovoltaic(BIPV) system can reduce cost by replacing building facade as construction material such as roofs, outer walls and windows as well as generating electricity. BIPV system should be applied at the early stage of architectural design. However, it is hard to decide whether using BIPV system or not for architects and builders who are not professional at BIPV system because performance of system is considerably influenced by types of module, installation position, installation methods and so on. It is also hard for experts because commercialized analytical program of photovoltaic systems is too complicated to use and domestic meteorological data is limited to partial areas. Therefore, we need evaluation program of BIPV system which can easily but accurately interpret generating performance and evaluate validity of BIPV system at the early stage of architectural design even for inexpert. Method: In this study, we collected meteorological data of domestic major region and analyzed generation characteristic of BIPV system by using PVsyst(commercialized software) in accordance with regions, types of solar module, place and methods of installation and so on. Based on this data, we developed performance evaluation program of BIPV system named BIPV-Pro, through multiple regression analysis and evaluated its validity. Result: When comparing predictive value of annual average PR and annual electricity production of BIPV-Pro an that of PVsyst, each of root mean square error was 0.01897 and 123.9.

초고층건물에서의 풍력발전 적용을 위한 건물형태별 기류분석 (A Study on Analysis of Air Flow for Wind Power System by Shape of Super High-rise building)

  • 장호진;이동윤;박진철;이언구
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.42-47
    • /
    • 2011
  • This study aims to choose installation location of wind power system and analyze influence factors of wind power system by shape of super high-raise building by using CFD simulation. As a result of this study, wind power system is more applicable to streamlined building than normal building. Round openings are seemed to be the most efficient shape for building integrated wind power system in types applying venturi effect. Safety and vibration should be considered in the case of application of wind power system between the buildings.

  • PDF

발코니 일체형 태양광발전시스템의 발전성능 분석 (Analysis of Performance of Balcony Integrated PV System)

  • 김현일;강기환;박경은;소정훈;유권종;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.32-37
    • /
    • 2009
  • Photovoltaic(PV) permits the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of building integrated balcony PV system and analyzed both performance and problems of this system. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 74.7%.

BIM지침의 통합관리를 위한 구조화에 관한 연구 (A Study on Development of Framework Based BIM Guideline System)

  • 한지수;이세잎;조찬원;김구택;조주원
    • 한국CDE학회논문집
    • /
    • 제20권2호
    • /
    • pp.210-219
    • /
    • 2015
  • As various contractors have been asking BIM data in the construction industry, BIM guidelines and standards has become increasingly important these days. Above all, BIM guidelines should be established properly because it is utilized at the earliest stage of BIM data creation. However, each of the existing BIM guidelines was totally different by contractors, disciplines or phases so that it caused problems about repetitious work, inefficient management and so on. In order to overcome these problems, we suggest integrated management system for BIM guidelines. We firstly collected and analyzed existing guidelines, secondly standardized guideline phrases and lastly constructed data structure of integrated management system. This integrated management system is expected to increase work efficiency to avoid working error for designers and enable easy creation or revision of BIM guidelines for contractors.

차양형 태양광발전시스템의 설치 및 운영에 관한 연구 (Installation and Operating with Photovoltaic System of Sunshade Type)

  • 이소미;심헌;이용호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.136-141
    • /
    • 2005
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. So, the purpose of this research is to present how to get PVIB which can be applied building facade and how to apply it. From the basis of these results this study will intend to develop an integrated for optimal design of PV System.

  • PDF

10kW급 지붕재용 태양전지모듈 실증연구 (Demonstration Study of 10kW Poly Metal Panel integrated PV Module)

  • 이소미;노지희;주만식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.246-249
    • /
    • 2007
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are sol id state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. So, this paper describes a design and performance test of the 10kW poly metal pv module(pmpp) system. It is concluded that the prediction of BIPV system's performance should be based on the more accurate PV module installation.

  • PDF

빌딩 오토메이션 시스템의 향상된 통합 방안 (Advanced Integration of Building Automation System)

  • 임채성;심일주;장경배;백상민;유종일;정의국;박귀태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.496-499
    • /
    • 2003
  • System Integration is significant role in building, because it is that the more building system is integrated, the more they can save management costs and energy costs. Nowadays system protocols in building use BACnet, LonWorks, etc. to integrate effectively, but their interoperability is not perfect. Therefore, we propose system integration using Ethernet and TCP/IP for perfect harmony. When data network protocol, Ethernet and TCP/IP is used for control network, there are several problems. But there have been solved by many researches. therefore it is possible that building system integrate to use Ethernet and TCP/IP. Finally, we show that Ethernet and TCP/IP can be used for building automation system integration.

  • PDF

중약진지역 구조물과 스마트 최상층 면진시스템의 통합최적설계에 대한 연구 (Study of Integrated Optimal Design of Smart Top-Story Isolation and Building Structures in Regions of Low-to-Moderate Seismicity)

  • 김현수;강주원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권5호
    • /
    • pp.13-20
    • /
    • 2013
  • 구조물의 지진응답을 저감시키기 위하여 추가적인 감쇠기나 진동제어장치가 일반적으로 사용된다. 이때, 추가적인 감쇠장치의 제어성능은 대상구조물 특성의 변화 없이 검토된다. 본 연구에서는 구조물과 스마트 제어장치의 다목적 통합최적화를 수행하였고 스마트 최상층 면진시스템이 설치된 구조물의 구조물량 저감의 가능성을 분석하였다. 이를 위하여 20층 예제구조물이 사용되었으며 MR 감쇠기와 저감쇠 탄성베어링을 사용하여 스마트 면진시스템을 구성하였다. 중약진지역의 설계스펙트럼을 바탕으로 생성된 인공지진하중을 사용하여 구조해석을 수행하였다. 수치해석결과, 스마트 최상층 면진시스템이 중약진지역에 있는 구조물의 응답과 면진층 변위를 동시에 효과적으로 줄일 수 있는 것을 확인하였다. 본 연구에서 제안된 통합최적설계기법으로 구조물량 및 감쇠기 용량을 적절하게 줄이면서도 우수한 제어성능을 발휘하는 다양한 설계 대안을 제공할 수 있었다.

대학교 기숙사의 전력소비량과 BIPV시스템의 발전효율·부하부담율에 관한 연구 (A Study on the Power Consumption and the Generation Efficiency and Load Rate of the Building Integrated Photovoltaic System in University Dormitories)

  • 서원덕;이강국;홍원화
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.87-93
    • /
    • 2011
  • This study examines building's power consumption unit cost and Building Integrated Photovoltaic (BIPV)'s generation efficiency and load rate with the subjects of university dormitory buildings in order to suggest foundational data for new and recycled energy use and management to plan and operate university dormitories afterwards. Thereby, this research gained the following findings. 1. The quantity of solar radiation and efficiency change in the BIPV system applied to the research subject buildings after the lapse of time was averagely 8.7%, and it is thought that temperature increase determines conversion efficiency with the influence of surrounding outside temperature and the module's temperature. 2. The generation efficiency of the BIPV system in the research subject buildings was averagely 10.9%. In May, it was 13.9%, and in January, it was the lowest as 10.25%. Considering the fact that power consumption reduces during an intermediate period, it will be necessary to establish measures for equipment and power consumption load balancing. 3. The monthly load rate of the BIPV system was averagely 4.09%. In May, it was the highest as 4.94%, and in July, it was the lowest as 3.24%. 4. It is intended to conduct constant follow-up research on estimating university dormitory building's power consumption unit cost and examining the generation efficiency and load rate of the BIPV system.

구조물 내구성 향상을 위한 방수품질 관련 통합정보시스템 활용방안에 관한 연구 (Application Method of Integrated Information System on waterproofing Quality for Improving Structure Durability)

  • 강효진;안기원;김병일;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.339-340
    • /
    • 2018
  • Contemporary concrete structures make use of underground spaces as parking lots and other comfort facilities for efficiency purposes. As underground environmental conditions are in constant exposure to degradation factors from the environment such as groundwater, hydraulic and soil pressure, structural movement and settlement, structural defects in the form of leakage occur. Current maintenance regulations and regimes are unable to respond to this field, as degradation mechanisms in underground environments are still unclear. In this regard, this study proposes the utilization of integrated information sharing system that can provide various technical information for construction designs to prevent leakages in underground concrete structures.

  • PDF