• Title/Summary/Keyword: Building Facility

Search Result 1,260, Processing Time 0.03 seconds

A Study on the Earthquake Safety Assessment of Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 지진 안전성평가에 관한 연구)

  • Ham, Eun-Gu;Lee, Sung-Il
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.226-235
    • /
    • 2021
  • Purpose: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Method: The risk assessment for earthquakes was conducted in accordance with the current design standard (KBC2016) for the Coalescer facility, which is a major facility of energy storage facilities. Result: In this study, by statically loading earthquake loads and evaluating the level of collapse prevention of special-class structures, facility managers can easily recognize and evaluate the risk level, and this analysis result can be applied to future facility risk management. Earthquake analysis was performed so that. Conclusion: As a result of analyzing the Coalescer facility according to the current design standard KBC2016, the stress ratio of the main supporting members was found to be up to 4.7%. Therefore, the members supporting Coalescer were interpreted as being safe against earthquakes with a reproducibility period of 2400 years that may occur in Korea.

A Construction of the N-BMS Focused on the Building Service Equipment (N-BMS : National Building Management System) (건물 군관리시스템 구축방안)

  • Lee, Tae-Won;Kim, Yong-Ki;Kang, Sung-Ju
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.149-154
    • /
    • 2007
  • Now, in Korea, the performances of the building service equipment relay on the individual superintendent's share for the assessment of performance, fault detection, deterioration diagnosis of the building service equipment. As the result, very different quality of the performance or the durability of equipment is being obtained with his skill and effort and it is also not easy to assess that quality. This finally lead to the waste of labor force and the operating cost due to the high-cost, low-efficiency system. How to construct the N-BMS was considered to save energy, resource and to conserve performance of building service equipment. The FEMIS, facility, energy/environmental management & information system, for building service offer management process integrated with BAS, FMS and EMS and so on.

  • PDF

A Study on Comparing and Analyzing Domestic and Foreign Green Building Certification Criteria for School Facility -Focused on the G-SEED and LEED, BREEAM- (국내외 학교시설 녹색 건축 인증제도의 비교분석에 관한 기초연구 -G-SEED와 LEED, BREEAM을 중심으로-)

  • Lee, Jong-Kuk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.3
    • /
    • pp.15-22
    • /
    • 2014
  • Proceeded with a research with basic data about the qualification standard improvement scheme about the environment school architecture in which a comparison analyze the specialized field of BREEAM system of LEED of the hit environment building qualification standard G-SEED of the domestic and U.S Green Building Counci evaluated with the certification system of the world top class and Building Research Establish, essential item, and mark distribution and weight in this study at this and which I hit with a domestic afterward. The school facility with a hub among the equipment receiving the hit environmental qualification standard, and the range of this research does LEED of the domestic green building certification system February is revised in 2013 G-SEED and which US and BREEAM in UK with a range. The way of the research checked the environment school building certification system and situation hit home and abroad, and a comparison analyze the division of the specialized field of each country qualification standard, essential item, and mark distribution and weight.

A Study on the Decision Factors and Satisfaction of SMEs

  • Yongsang PARK;Jaetae KIM
    • The Journal of Economics, Marketing and Management
    • /
    • v.11 no.3
    • /
    • pp.81-92
    • /
    • 2023
  • Purpose: The purpose of this study is to identify the determinants of store occupancy based on the rental characteristics of small and medium-sized enterprises (SMEs) renting buildings across the country, and to analyze the satisfaction level after opening. Research design, data and methodology: The study conducted an empirical survey through questionnaires targeting individual business owners, corporate representatives, and executives and employees nationwide, including Seoul, Gyeonggi, and other metropolitan areas and provincial cities. Results: In this study, the most important factor that SMEs consider when deciding whether to rent a commercial building or office is financial characteristics, followed by management characteristics, location characteristics, building characteristics, and facility characteristics. In addition, management characteristics were found to have the greatest impact on rental satisfaction of SMEs, followed by financial characteristics, building characteristics, and location characteristics in order. Conclusions: Since the lessor cannot immediately improve the location characteristics or building characteristics, in order to increase the rental satisfaction of small and medium-sized businesses in a relatively short period of time, it is necessary to improve managerial characteristics such as prompt civil complaint handling and clean management of the building. In addition, it is analyzed that if the factors that can reduce the burden on the tenants are found in advance and reflected in the financial characteristics, the satisfaction of the tenants can be increased.

Simulations for the cesium dynamics of the RF-driven prototype ion source for CRAFT N-NBI

  • Yalong Yang;Yong Wu;Lizhen Liang;Jianglong Wei;Rui Zhang;Yahong Xie;Wei Liu;Chundong Hu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1145-1152
    • /
    • 2024
  • To realize an initial objective of the negative ion-based neutral beam injection (N-NBI) at the Comprehensive Research Facility for Fusion Technology (CRAFT) test facility, which targets an H0 beam power of 2 MW at an energy of 200-400 keV and a pulse duration of 100 s, it is crucial to study the cesium dynamics of the negative ion source. Here a numerical simulation program CSFC3D is developed and applied to simulate the distribution and time dynamics of cesium during short pulses. The calculations show that most of the cesium on the plasma grid (PG) area originates from the release of cesium that is accumulated within the ion source in the plasma phase. Increasing the wall temperature reduces the loss of cesium on the wall of the ion source. Furthermore, the thickness of the cesium monolayer is directly influenced by the PG temperature. Both simulated and experimental results demonstrate that maintaining the PG temperature between 180 ℃ and 200 ℃ is essential for enhancing the performance of the ion source and optimizing the cesium behavior.

3-D Modelling of Facility Using Digital Map and Aerial Photos (수치지도와 항공사진을 이용한 시설물 3차원 모델링)

  • 손홍규;최종현;김의명
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.303-308
    • /
    • 2003
  • Facility management system has been studied recently due to its increasing demand. As a starting step it is necessary to create 3-D shape of the facility. In this study, we attempted to create 3-D shape of the buildings by fusing the raster and vector information. the raster information comes from stereo aerial photographs and the vector information comes from the existing 2-D digital map. GPS surveying and data conversion using ACAD and ARCINFO also performed to extract building height from stereo aerial photographs. Finally we could be able to perform semi-automatic 3-D building modeling with fusion of two sources of information.

  • PDF

Patterns in User Requests for Facility Management Services in Higher Education Facilities (대학 시설물 유지관리 서비스 사용자 요청 패턴 분석)

  • Uhm, Miyoung;Lee, Ghang
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.95-96
    • /
    • 2015
  • This paper aims to identify patterns in users' requests for facility management (FM) services in higher education facilities. We analyzed data collected from 309 service request forms, made available via a department office and an enterprise resource planning system, at a private university in Seoul between May 2009 and February 2015. We found that the number of user requests were the highest in September and October. Requests for electronic and communication (E/C) services outnumbered those for architectural services and mechanical and plumbing (M/P) services. Repair requests for doors and windows were the most common under architectural services; repairs for air-conditioners and radiators were the most commonly under M/P services; and installation of electrical outlets, telephone wires, and internet services were the most sought-after E/C services. Maintenance requests were received every three months, while repair requests were received every six or seven months.

  • PDF

A Conceptual Framework for Comprehending the Spatial and Communication Layers in R & D Laboratories

  • Yoo, Uoo Sang
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.35-45
    • /
    • 2005
  • This study discusses "mechanisms" in a research facility, specifically focusing on the question of how we can understand what happens in the physical environment and the communication between researchers. This study attempts to address this question by examining two physical settings, before and after the move of one research-educational facility, the Institute of Paper Science and Technology. The objective of the study is to suggest conceptual models to comprehend the relationships between spatial layouts and communication. The study examines the underlying mechanism of how the levels of communication meet the layers of spatial structure. The paper has four parts. First, the preceding studies will be reviewed evoking some issues of communication and physical setting in research facilities. Second a conceptual typology in office plan will be developed providing a theoretical framework to review the spatial organization of the subject research facility, the Institute of Paper Science and Technology (IPST). Third, the spatial organization of the former building (before the move) and the present building (after the move) of IPST will be analyzed. Finally, conceptual models of the mechanism between the communication and the spatial organization will be drawn up.

A Study on the Improvement for the Facility targeted to Aged Person (노인전용주거시설의 발전방향에 관한 연구)

  • Yun Kun-Sug;Lee Min-Su;Cho Young-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.167-169
    • /
    • 2005
  • Currently the industrialization, the urbanization, and the phenomenon of nuclear family is mainstream of korean society. And our country enter into an aging society, on the contrary. The concept of support for aged person is dwindled away. The main reason can be summarized as the aged person's consciousness and the family's economical burden. So, the concern about the facility for the aged person has being issued as a necessary factor to be considered by public. Therefore. the problems of the facility were analyzed and the improvement direction for them were suggested in this study.

  • PDF

Hydrogen Behavior at a Subcomparment in The Containment Building

  • Lee, U.J.;Park, G.C.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.495-500
    • /
    • 1997
  • For hydrogen management in severe accidents with degraded nuclear core of PWR's, several experiments have been performed in the SNU hydrogen mixing facility. The objectives are understanding the extent of hydrogen mixing and analyzing the effects of factors which dominate uniform or non-uniform mixing at compartments in the containment building. The facility represents on a 1/11th linearly scaled model of the YGN unit 3&4, hydrogen was simulated by helium. Because there are the gaps between safety injection tank and compartment layers in the containment, the test facility was constructed in three dimentinal mode for analyzing of mixture behavior through the gaps. From the experimental results we could conclude that overall hydrogen concentration distributed uniformly in the free volume of the test compartment, but fluctuated in the gaps. This paper is focused on experimental result from several experiment.

  • PDF