• Title/Summary/Keyword: Building Energy Assessment

Search Result 292, Processing Time 0.027 seconds

아트리움 건축의 개방감을 상승시키는 계획조건에 관한 연구 (A Study on Planning Conditions to Improve Openness assessment in Atrium)

  • 이지영;임재한;정진주
    • KIEAE Journal
    • /
    • 제8권2호
    • /
    • pp.41-46
    • /
    • 2008
  • Owing to a space covered by glass, atrium is an attractive space with a possibility as an inner public space but a typical building type with a high-energy load. From the aspect of global environmental issues, to reduce energy load is an important assignment to solve. Contriving a planning guideline of an opening is considered as the most effective environment adjustment method, to offer a highly assessed amenity space and secure openness to outside, keep the energy load to a minimum, and apply the natural energy such as daylight to a maximum at the same time. Users' assessment of environment was performed by questionnaire survey, then the structure of users' assessment was analyzed and design condition was regulated by multiple regression analysis. The opening design guideline to offer a highly assessed space was proposed with concrete environment adjustment method.

Study for Improvement of Domestic System through Regulation based on Comparison of Green Building Certification System Analysis - Focused on the G-SEED, BREEAM

  • Hyun, Eun-Mi;Kim, Yong-Sik
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.13-20
    • /
    • 2015
  • The main purpose of the green buildings by reducing energy consumption and carbon footprint of the building society, global as to ensure the sustainability of the building and the environment. These regulations and schemes are used to activate the green buildings were made on the basis of the relevant laws and regulations. Mainly in the research for the improvement of the domestic institutional assessment items, the analysis of the legislation was fundamentally focused on Scoring the incomplete state. The analysis based on the laws and regulations of the institution is the way to know the purpose and direction of the respective certification. This study was performed in the following order to target the new commercial buildings. First, the analysis of the geungeobeop G-SEED and BREEAM. Second, we analyze the content and method of building energy performance in the certification system. As a result, Green Building Act is broad in relation to the composition of the contents are building for the activation energy green building and EPI is dealt with in an abstract and presented the applicability of such documentary content of insulation and airtightness, efficient machine. In contrast, the UK has been directly limit the carbon footprint of buildings in the Building Regulations Part L and evaluate them in BREEAM. This analysis of the ways to reduce substantially the energy for domestic green building regulations should be addressed through the feed.

실내 건축자재 중 천연방사성핵종의 정량분석법 연구 (Method development for quantitative analysis of naturally occurring radioactive nuclides in building materials)

  • 임종명;이훈;김창종;장미;박지영;정근호
    • 분석과학
    • /
    • 제30권5호
    • /
    • pp.252-261
    • /
    • 2017
  • 천연방사성핵종을 함유한 물질들은 인간 활동에 의해 인위적인 조작과정을 거치면서 농축되는 경우 방사선 노출에 따른 위해를 증가시킬 수 있다. 본 연구는 다양한 전처리 방법 및 분석 방법 간 비교를 통해 분석정확도를 평가하고 실내 건축자재 중 $^{232}Th$, $^{235}U$, $^{238}U$의 천연방사성핵종을 분석하기 위한 최적의 분석 방법을 확립하고자 하였다. ICP-MS를 이용한 실내 건축자재 중 천연방사성핵종 분석방법을 확립하기 위하여, 인증표준물질 5종을 왕수, 불산, 과염소산의 습식산화법과 용융법의 전처리법에 따른 U, Th의 분석 정확도 및 정밀도를 평가하였고, 최적의 전처리법으로써 용융법과 $Fe(OH)_3$ 공침법을 선정하였다. 확립된 분석방법을 석고보드, 벽돌, 시멘트, 페인트, 타일과 벽지 총 51 종의 실내 건축자재 시료에 적용하여 천연방사성핵종의 농도를 정량 분석하였다. 또한 동일한 시료에 대해 감마분광분석법 중 간접측정법을 사용하여 $^{238}U$, $^{232}Th$의 농도를 정량하고 ICP-MS 분석 결과와 비교하였다.

RADIANCE 프로그램을 이용한 오피스 건축물에서의 에너지 절감율 예측을 위한 BIN Method 검토 (Assessment of BIN Method to Predict Energy Saving in Office Building Using the RADIANCE Program)

  • 홍성관;박병철;최안섭;이정호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.154-159
    • /
    • 2008
  • Daylight is an important component for human and energy saving. Also, available daylight in inside provides positive influence on psychological and physiological aspects as well as good visual environment. It is important to lighting design for office building not only designing for artificial lighting but also using daylight for energy savings. Therefore, lighting designers and architectures must consider the effects of the daylight for human environment and energy savings. The BIN Method is one of the methods to predict energy savings using computer simulation but it spends more time than expectation. So, this study performs to simulate a simple space using the RADIANCE for examination and simplification of the BIN Method.

  • PDF

Development of a Quality Assurance Safety Assessment Database for Near Surface Radioactive Waste Disposal

  • Park J.W.;Kim C.L.;Park J.B.;Lee E.Y.;Lee Y.M.;Kang C.H.;Zhou W.;Kozak M.W.
    • Nuclear Engineering and Technology
    • /
    • 제35권6호
    • /
    • pp.556-565
    • /
    • 2003
  • A quality assurance safety assessment database, called QUARK (QUality Assurance Program for Radioactive Waste Management in Korea), has been developed to manage both analysis information and parameter database for safety assessment of low- and intermediate-level radioactive waste (LILW) disposal facility in Korea. QUARK is such a tool that serves QA purposes for managing safety assessment information properly and securely. In QUARK, the information is organized and linked to maximize the integrity of information and traceability. QUARK provides guidance to conduct safety assessment analysis, from scenario generation to result analysis, and provides a window to inspect and trace previous safety assessment analysis and parameter values. QUARK also provides default database for safety assessment staff who construct input data files using SAGE(Safety Assessment Groundwater Evaluation), a safety assessment computer code.

Development of Initial Design Stage Guidelines for nearly Zero Energy Offices : A Central-Climate Zone of Korea Case Study

  • Kang, Hae Jin;Yi, Won
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.67-74
    • /
    • 2015
  • This study aimed to develop a design manual to be used during the initial stage of the nearly Zero Energy Building (nZEB) design process. Recently, with the increased demand for nZEBs, there are many architects and architectural firms who are becoming interested in nZEB design. However, since the nZEB design process requires a different approach to the conventional building design process, architects have difficulties with application of the nZEB design process in their projects. Therefore, a design manual which can be used in the nZEB design process was developed in this study. Based on an intensive literature review, energy-saving strategies and their performance levels, which affect heating and cooling energy consumptions were established for a reference building. To analyze the sensitivity of each energy strategy to the overall performance, computer simulations using EnergyPlus were performed. At the same time, an Analysis of Variance assessment was conducted to estimate the relative importance of each energy factor. The energy sensitivity and priority of the energy factors was developed into a set of design guidelines.

초고층 건축물의 환경적 특성 반영을 위한 국내.외 친환경 건축물 인증제도 비교.분석 (Comparison of Domestic and International Green Building Certification Criteria for Application of Environmental Characteristics in Tall Buildings)

  • 차민수;김태훈;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.247-251
    • /
    • 2010
  • Recently due to the crisis of environment and resources, construction industry that effect a lot on nature than any other industries is essentially required to consider environmental element through the life cycle. Lots of advanced countries and Korea have already been running green building certification systems. However, GBCC(Green Building Certification Criteria) in Korea is lack of assessment criteria that apply environmental characteristics of tall building in compared with that in advanced countries. To improve the problem, we compared GBCC with LEED(Leadership in Energy and Environmental Design) through the case study. This study provides preliminary data for reflecting environmental characteristics of tall building in GBCC.

  • PDF

사무소건축 리모델링에서의 전과정 평가에 관한 연구 - 전기 부분을 중심으로 - (A study of LCA(Life Cycle Assessment) to a office building remodeling - Focused on Electrical Equipment -)

  • 이선동;유호천
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.85-92
    • /
    • 2004
  • Environmental issues become one of today's central concerns due to draining natural resources and environmental pollution. Architecture is given a great deal of weight on the evoking environmental pollution. In this point of view, polluting factors in architectural planning and construction were predicted in advance and alternative plans were studied, In investigation of alternative plans, both environmental pollution and economical efficiency of various alternatives were considered. A office building was analyzed for energy consumption and construction environmental load by appling LCA. Applying LCA to a office building includes a total amount of materials and energy consumption, environmental impacts and economical efficiency evaluation. In present study, LCA applied to electrical part of a office building and economical efficiency evaluation was considered.

창호시스템의 환경성능평가기법 정립에 관한 연구 (A study on the proposal of environmental capacity criterion method for windows system in buildings)

  • 최두성;김은규;조균형
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.101-109
    • /
    • 2004
  • This research investigates the life-cycle energy consumption of the windows used for the building's exterior cladding, and its environmental potential aspects by utilizing the LCA. The research scope has taken account of the entire life-cycle of the windows from the extraction of raw materials to its disposal, of which given sample building type is an apartment building. Results gained from the LCA of the windows as one of the steps in analysis reflects the current global interest and analysis trend towards the world's environmental issue on all fields of industry including the architectural industry, of which its newly established standards of architectural windows can further promote more environmentally sustainable factor compared to the previous analysis (focused more on energy efficiency assessment of the use stage).

외피 친환경 성능평가 II: 광선반, RetroLux (Performance Assessment of Building Envelopes II: LightShlef, RetroLux)

  • 김덕우;박철수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.83-90
    • /
    • 2009
  • As a series of 'Performance Assessment of Building Envelopes I: Double Skin Facade', three types (interior, exterior, mixed (int.&ext.)) of lightshelves and RetroLux were examined in terms of $CO_2$ emissions. It is shown that the exterior lightshelf could achieve the most energy savings (9.6-38.7%) in general office buildings due to blocking solar radiation before entering the indoor space. However, the interior lightshelf is the worst (1.4-5.2%) among three of them. The RetroLux has two components: (1) sun-reflector (first louver component), (2) light shelf for improving daylight induction (second louver component). Due to these two components, solar radiation from windows is filtered depending on seasonal variation (solar altitude). Therefore, the RetroLux can reduce 18.0-27.9% of annual energy consumption (both cooling and heating), and $552-3,290Won/m^2{\cdot}yr$ of operation cost is saved.

  • PDF