• 제목/요약/키워드: Build-up factor

검색결과 166건 처리시간 0.03초

SLA를 이용한 신속 시작작업에서 최적 성형방향의 결정 (Determination of Optimal Build-up Direction for Stereolithographic Rapid Prototyping)

  • 허정훈;이건우
    • 한국정밀공학회지
    • /
    • 제13권4호
    • /
    • pp.163-173
    • /
    • 1996
  • Stereolithography is a process used to rapidly produce polymer components directly form a computer representation of the part. There are several considerations to be made for the efficient use of the process. Especially, the build-up orientation of part critically affects the part accuracy, total build time and the volume of support structures. The purpose of tis study is to determine the optimal build-up part orientation for the SLA process with improving part accuracy, and minimizing total build time and the volume of support structures. The forst factor is related to the area of surfaces whioch have staircase protrusions after solidification, the second factor is related to the total number of layers, and the third factor is related to the area of the surfaces which need to be supported with support structures. An algorithm is developed to calculate the staircase area, quantifying the process errors by the volume of materials supposed to be removed or added to the part, and the optimal layer thickness for the SLA system which can handle the variable layer thickness. So the optima l part orientation is determined based on the user's selections of primary criter- ion and the optimal thickness of layers is calculated at any part orientations.

  • PDF

SLA를 이용한 신속 시작작업에서 최적 성형방향의 결정

  • 허정훈;이건우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 춘계학술대회 논문집
    • /
    • pp.552-558
    • /
    • 1995
  • Stereolithography is a process used to rapidly produce polymer components directly from a computer-representation of the part. There are several considerations to be made for the efficient use of te process. Especially, the build-up orientation of part critically affect to the part accuracy, total build time and the volume of support structures. Te purpose of this study is to determine the optimal build-up part orientation for the SLA process with improving part accuracy, minimizing total build time, and the volume of supprot structures. The first factor is related to the area of surfaces which have staircase protrusions after solidification, the second factor is related to the total number of layers, and the third factor is related to the area of the surfaces which need to be supported with support structures. An algorithm is developed to calculate the staircase area with quantifying the process planning errors that the volume of materials is supposed to be removed or added to the part, and the optimal layer thickness for the SLA system whichcan hadle the variable layer thickness in different orientations achieved by rotating the given part to the specified finite directions. So the optimal part orientation is determined based on the user's selections of primary criterion and the optimal thickness of layers is calculated at any part orientations.

BCB Polymer Dielectrics for Electronic Packaging and Build-up Board Applications

  • Im, Jang-hi;Phil-Garrou;Jeff-Yang;Kaoru-Ohba;Masahiko-Kohno;Eugene-Chuang;Jung, Moon-Soo
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.19-25
    • /
    • 2000
  • Dielectric polymer films produced from benzocyclobutene (BCB) formulations (CYCLOTENE* family resins) are known to possess many desirable properties for microelectronic applications; for example, low dielectric constant and dissipation factor, low moisture absorption, rapid curing on hot plate without reaction by-products, minimum shrinkage in curing process, and no Cu migration issues. Recently, BCB-based products for thick film applications have been developed, which exhibited excellent dissipation factor and dielectric constant well into the GHz range, 0.002 and 2.50, respectively. Derived from these properties, the applications are developed in: bumping/wafer level packaging, Ga/As chip ILD, optical waveguide, flat panel display, and lately in BCB-coated Cu foil for build-up board. In this paper, we review the relevant properties of BCB, then the application areas in bumping/wafer level packaging and BCB-coated Cu foil for build-up board.

  • PDF

On the use of flyash-lime-gypsum (FaLG) bricks in the storage facilities for low level nuclear waste

  • Sidhu, Baltej Singh;Dhaliwal, A.S.;Kahlon, K.S.;Singh, Suhkpal
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.674-680
    • /
    • 2022
  • In the present study, radiation shielding and protection ability of prepared Flyash-lime-Gypsum (FaLG) bricks has been studied in terms of energy exposure build up factors and dose parameters. The energy exposure build up factors of Flyash-lime-Gypsum (FaLG) bricks have been calculated for the energy range of 0.015 MeV-15 MeV and for penetration depth upto 40 mfp directly using a new and simplified Piecewise Linear Spline Interpolation Method (PLSIM). In this new method, the calculations of G.P fitting parameters are not required. The verification and accuracy of this new method has been checked by comparing the results of exposure build up factor for NBS concrete calculated using present method with the results obtained by using G.P fitting method. Further, the relative dose distribution and reduced exposure dose rate for various radioactive isotopes without any shielding material and with Flyash-lime-Gypsum (FaLG) bricks have been calculated in the energy range of 59.59-1332 keV. On the basis of the obtained results, it has been reported that the prepared Flyash-lime-Gypsum (FaLG) bricks possess satisfactory radiation shielding properties and can be used as environmentally safe storage facilities for low level nuclear waste.

Bolus를 대체하기 위해 자체 제작된 선량상승영역 변환기를 투과한 광자선의 특성 (Characteristics of Photon Beam through a Handmade Build-Up Modifier as a Substitute of a Bolus)

  • 김성준;이승준;문수호;설기호;이정은
    • 한국의학물리학회지:의학물리
    • /
    • 제25권4호
    • /
    • pp.225-232
    • /
    • 2014
  • 본 논문에서는 자체 제작된 선량상승영역 변환기(build-up modifier, BM)을 투과하는 high energy photon beam의 심부선량백분율(PDD)을 특성을 측정하고 이 결과를 토대로 BM 산란인자(BM scatter factor, $S_{BM}$)를 계산하였다. 다양한 조건에서 BM scatter가 PDD의 Build-up region에 미치는 영향을 평가하고 BM의 유용성을 알아보는 것이 본 연구의 목적이다. $S_{BM}$는 BM을 사용하지 않은 SFS 30 mm에서 측정된 산란인자의 값을 1로서 정규화 하였다. 가장 큰 SFS 200 mm의 경우, 6 MV 광자선을 사용할 때 $S_{BM}$는 두께에 따라 각각 1.331, 1.519, 1.598, 1.641, 그리고 1.657이었다. 10 MV 광자선에는 각각 1.384, 1.662, 1.825, 1.913, 그리고 2.001이었다. BM의 효과는 bolus의 최대 76% 효율을 가지는 것으로 나타났다. Bolus를 밀착시키기 어려운 특정적 부위에 대해 BM은 그 대안으로써 효과적인 장치가 될 수 있을 것으로 기대된다.

Broad Beam Gamma-Ray Spectrometric Studies with Environmental Materials

  • El-Kateb, Abdul-Hamid Hussein
    • Journal of Radiation Protection and Research
    • /
    • 제43권2호
    • /
    • pp.75-84
    • /
    • 2018
  • Background: Gamma-ray spectrometry helps in radiation shielding problems and different applications of radioisotopes. Experimental arrangements including broad beam geometries are widely used. The aim is to investigate and evaluate the ${\gamma}-ray$ spectra via attenuation by environmental materials. Materials and Methods: The photo peak to nominated parts in the ${\gamma}-ray$ spectra and the attenuation coefficients ${\mu}_b/{\rho}$ from broad beam geometries are measured for the materials water, soil, sand and cement at the energies 0.662, 1.25, and 1.332 MeV with a $3{^{\prime}^{\prime}}{\times}3{^{\prime}^{\prime}}$ NaI(Tl) detector. Results and Discussion: The ${\gamma}-ray$ spectra vary according to changes in the effective atomic number $Z_{eff}$ of the attenuator, the photon energy and the solid angle. The peak to total ratios are the most sensitive parts to variations in the experimental conditions and overturn in the region 0.663 MeV to 1.332 MeV. This is indicated as inversion trend. The results are discussed in view of $Z_{eff}$ and the experimental conditions. The intensity build-up is larger at the lower energy and larger scattering angles in agreement with Klein-Nishina formula and other results. The build-up factor B is$${\sim_=}$$1 at high ${\gamma}-energies$ and small scattering angles. Conclusion: The sensitivity to material characteristics decrease gradually from peak: to total, to Compton valley, to Compton plateau ratios. Rigorous collimation is necessary at small energies. Cement, of the largest $Z_{eff}$, is characterized by the maximum broad beam mass attenuation coefficients ${\mu}_b/{\rho}$. The obtained results provide information to decide for the suitable experimental set-up based on aim of the work.

진동대 시험을 통한 액상화되는 지반의 수평지반반력계수에 대한 연구 (Modulus of Horizontal Subgrade Reaction in Liquefying Sand by Shaking Table Test)

  • 박종관;한성길;김상규;이용도
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.255-262
    • /
    • 2000
  • Shaking table tests were peformed to evaluate the subgrade reaction of ground according to the build-up of pore water pressure. Model pile was installed in the sand ground. The acceleration of the model ground, the pore water pressure build-up and displacement of pile were recorded by measuring devices. Subgrade reaction approach based on Winker soil model was applied to obtain the modulus of the horizontal subgrade reaction. The results of analysis show that the reduction factor of the subgrade reaction due to pore pressure increase is about 1 and the horizontal subgrade reaction of liquefied ground is not influenced by the stiffness of pile, a ground acceleration and the intial ground density.

  • PDF

패드 베어링에서 패드사이의 거리가 유막압력에 미치는 영향 (Effects of Distance between Pads on the Film Pressure in Pad Bearings)

  • 김종수;김경웅
    • Tribology and Lubricants
    • /
    • 제13권1호
    • /
    • pp.53-61
    • /
    • 1997
  • Experiments are conducted to investigate the effects of distance between pads on the film pressure and the inlet pressure build-up at the entrance of pad bearings. The inlet pressure and the film pressure are measured by manometers in several cases of the distance between pads. The experimental results are also compared with the theoretical results which are calculated using the several methods for the estimation of the inlet pressure. In the experimental results , the distance between pads has a large influence on the film pressure and the inlet pressure build-up a bearing entrance. It is also shown that the effects of the inlet pressure on the film pressure are remarkable, although inertia parameter is a little higher (${\ge}0.05$).

Chopper 방식을 이용한 형광등의 집단조광제어 시스템 개발 (Dimming Control System for Multi-Fluorescent Lamp Using Chopper Technique)

  • 전경준;임병노;박종연
    • 전기학회논문지
    • /
    • 제56권9호
    • /
    • pp.1584-1588
    • /
    • 2007
  • This paper proposed the voltage compulsion method that used chopper for light dimming control of fluorescent lamp. During the dimming period, electronic ballasts have the bad characteristics such as low power factor, high THD(Total Harmonic Distortion) and etc. The proposed dimmer improves power factor, THD of electronic ballast and has benefit such as low cost, simple build up.

선형가속기에서 상위조리개와 하위조리개의 교환에 의한 선량 변화의 고찰 (The study on dose variation due to exchange of Upper and Lower jaw in the linear accelerator)

  • 임충근;김회남;송기원
    • 대한방사선치료학회지
    • /
    • 제11권1호
    • /
    • pp.6-10
    • /
    • 1999
  • The field size can be beam output, therefore MonitorUnit can be varied due to field size dependence The purpose of this study is to evaluate and compare the dose variation according to exchange of collimator The measurements were perfomed with Wellhofer dosimetry system(water phantom. ion chamber. electrometer. system controller. build up cap. etc)and two types of linear accerlerator (Mevatron KD, MevatronMX) Scatter can be affected to field size dependence and scatter correction is separated into collimator and phantom components, scatter components can affect by exchanging of collimator Measurements of collimator scatter factor(Sc) was done in air with build up cap. 1)Square field (5cm2 to 40cm2) was measured 2)and then keeping the upper jaw constant at loom and varing lower jaw from 5cm to 40cm, 3)keeping the lower jaw constant at 10cm and varing upper jaw from 5cm to 40cm Measurements of total scatter factor(Scp) was done in water at Dmax as the procedure of collimator scatter factor measurements in water Dmax The total scatter factors were obtained to the following equation(Sp=Scp/Sc) The measured data is normalized to the data of reference field size($10{\times}10$), rectangular field is inverted to equivalent field to compare three field size data As the collimator setting is varied, the output was changed In conclusion, the error was obtained small but it must be eliminated if we intend to reach the common stated goal of $5\%$ overall uncertainty in dose determination

  • PDF