• Title/Summary/Keyword: Bone to Implant Contact

Search Result 255, Processing Time 0.026 seconds

A HISTOMORPHOMETRIC STUDY OF TWO DIFFERENT THREADED CP TITANIUM IMPLANTS (국내 제작 Avana 임프란트와 $Br{\aa}nemark$ 임프란트 주위 골조직에 대한 광학 및 형광 현미경학적 연구)

  • Han, Dong-Hoo;Jeon, Young-Sik;Kim, Jin;Kim, Seon-Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.531-541
    • /
    • 1999
  • The purpose of this study was to compare surface roughness and bone formation around two types of threaded commercially pure titanium implants manufactured by two different companies. The test implants were manufactured by Sumin synthesis dental materials Co. (Avana, Busan, Korea), while the controls were manufactured by Nobel Biocare (MK II, Goteborg, Sweden). To compare bone formation adjacent to newly product implant with $Br{\aa}nemark$ MK II implant, surface roughness was measured by Accurate 1500M and histomorphometric analysis was done. The results were as follows: 1. Measurement of surface roughness showed that Avana implant had a slightly more irregular surface compared with $Br{\aa}nemark$ implant. 2. In the light microscopic studies, no infiltration of inflammatory cells nor the giant cells were observed on both groups. 3. In the light and fluorescent microscopic studies, the amount of osseointegration and the extent and the timing of bone formation were similar. 4. There were no statistically difference between two groups in the average bone to implant con-tacts. Branemark implant; 67% (SD 23%), Avana implant; 70% (SD 16%). Comparing with $Br{\aa}nemark$ implant, Avana implant made of CP grade II titanium showed similar good bone healing, formation and osseointegration.

  • PDF

Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial

  • Kim, Jin-Cheol;Lee, Jungwon;Kim, Sungtae;Koo, Ki-Tae;Kim, Hae-Young;Yeo, In-Sung Luke
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.147-154
    • /
    • 2019
  • PURPOSE. This study aimed to evaluate the effect of two different implant-abutment connection structures with identical implant design on peri-implant bone level. MATERIALS AND METHODS. This clinical study was a patient-blind randomized controlled trial following the CONSORT 2010 checklists. This trial was conducted in 24 patients recruited between March 2013 and July 2015. Implants with internal friction connection were compared to those with external hex connection. One implant for each patient was installed, replacing the second molar. Implant-supported crowns were delivered at four months after implant insertion. Standardized periapical radiographs were taken at prosthesis delivery (baseline), and one year after delivery. On the radiographs, distance from implant shoulder to first bone-to-implant contact (DIB) and peri-implant area were measured, which were the primary and secondary outcome, respectively. RESULTS. Eleven external and eleven internal implants were analyzed. Mean changes of DIB from baseline to 1-year postloading were 0.59 (0.95) mm for the external and 0.01 (0.68) mm for the internal connection. Although no significant differences were found between the two groups, medium effect size was found in DIB between the connections (Cohen's d = 0.67). CONCLUSION. Considering the effect size in DIB, this study suggested the possibility of the internal friction connection structure for more effective preservation of marginal bone.

A histomorphometric study of dental implants with different surface characteristics

  • Pak, Hyun-Soon;Yeo, In-Sung;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.142-147
    • /
    • 2010
  • PURPOSE. One of the major keys to achieve successful osseointegration of the implant is its surface properties. The aim of this study was to investigate the bone response to dental implants with different surface characteristics using the rabbit tibia model. Tricalcium phosphate (TCP) coated, anodic oxidized and turned (control) surfaces were compared. MATERIALS AND METHODS. Seventy two implants were placed in the tibia of eighteen rabbits. Nine rabbits were sacrificed at 3 weeks of healing and the remaining nine were sacrificed at 6 weeks of healing. The bone-to-implant contact (BIC) and the bone volume density (BVD) were assessed by light microscope after 3 and 6 weeks of healing. RESULTS. Statistical analysis showed that no significant differences in the BIC and BVD were observed between the different implant surfaces and the control group at 3 weeks and 6 weeks of healing. Data also suggested that the BVD of all the surfaces showed significant difference at 3 and 6 weeks. CONCLUSION. The present study has showed that osseointegration occurred in all investigated types of surface-treated implants. In the current study all of the threads of the implants were observed to calculate BIC and BVD values (instead of choosing some of the threads from the bone cortex for example), which didn't make BIC or BVD percentage values better than in the control group, therefore the clinical relevance of these results remains to be shown.

Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load (임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석)

  • Jang, Jong-Seok;Jeong, Yong-Tae;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

The Study of Bone Healing Response According to the Various Surfaces of the Implant in the Mandible of the Mature Dog (성견 하악골에 식립한 다양한 임플란트 표면에서의 골 치유 양상에 관한 연구)

  • Lim, Hyun-Pil;Kim, Yong-Hak;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Choi, Hong-Ran
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.125-137
    • /
    • 2009
  • There are many reports that these implant surface treatments may affect to cellular reaction in the surface of implant. This study was done by installing the 8 type implant with the variable surface treatment, used or developed, in the mandible of the mature dog to evaluate how the method of surface treatment of the implant can affect to the bone healing by analyzing histologically and histomorphometrically and find out bone healing appearance periodically after installing implant. By using the 8 type implants which have the different surface treatment, 72 implants were installed on the mandible of 9 mature dogs, and 3 dogs were sacrificed on every 2, 4, 8 weeks. After making bone fragment by cutting and managing, we analyzed histologically, then compared with BIC(Bone to implant contact) for the histomorphometrical analysis. In the result of histological analysis, there was large amount of bone formation in good state on the adjacent area of implant in the 2 weeks testing group. At 4 weeks, although there was general bone formation, the new bone was separated with the basal bone. At 8 weeks, the new bone became matured and connected tightly to the basal bone. There was no difference in the each surface of 8 implants. In the result of histomorphometrical analysis, 2 weeks group had considerably lower value than 4 and 8 weeks group, and there was no difference between 4 and 8 weeks group. There was no difference in the each surface treatment of implants.

Biologic stability of plasma ion-implanted miniscrews

  • Cho, Young-Chae;Cha, Jung-Yul;Hwang, Chung-Ju;Park, Young-Chel;Jung, Han-Sung;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.43 no.3
    • /
    • pp.120-126
    • /
    • 2013
  • Objective: To gain basic information regarding the biologic stability of plasma ion-implanted miniscrews and their potential clinical applications. Methods: Sixteen plasma ion-implanted and 16 sandblasted and acid-etched (SLA) miniscrews were bilaterally inserted in the mandibles of 4 beagles (2 miniscrews of each type per quadrant). Then, 250 - 300 gm of force from Ni-Ti coil springs was applied for 2 different periods: 12 weeks on one side and 3 weeks contralaterally. Thereafter, the animals were sacrificed and mandibular specimens including the miniscrews were collected. The insertion torque and mobility were compared between the groups. The bone-implant contact and bone volume ratio were calculated within 800 mm of the miniscrews and compared between the loading periods. The number of osteoblasts was also quantified. The measurements were expressed as percentages and analyzed by independent t-tests (p < 0.05). Results: No significant differences in any of the analyzed parameters were noted between the groups. Conclusions: The preliminary findings indicate that plasma ion-implanted miniscrews have similar biologic characteristics to SLA miniscrews in terms of insertion torque, mobility, bone-implant contact rate, and bone volume rate.

A HISTOLOGIC COMPARATIVE STUDY OF LOADED AND UNLOADED TITANIUM IMPLANTS (LOADED IMPLANT와 UNLOADED IMPLANT의 조직학적 비교 연구)

  • Kim, Yung-Soo;Ko, Jea-Seung;Hwang, Sung-Myung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.1-16
    • /
    • 1991
  • In order to see the possible effect of the functional load-bearing after osseointegration of the titanium root form implant in dog a histologic study was conducted. One side of lower jaw was surgically prepared edentulousness and titanium implants were inserted. Some implants were functionally loaded through fixed detachable prosthesis and some are isolated and unloaded. The dog was sacrificed four months later and bone sections with implants were processed for histologic evaluation and the results were as follows ; (1) The bone to implant interface after four months of load bearing presented no mobility and no marginal bone loss radiographically and histologically. (2) The interface zone between compact bone and implant revealed a direct bone to implant contact and in some areas marrow tissue contacts were examined at the light microscopic level. (3) At the ultrastructural level the interface of surrounding compact bone matrix and implant, three types of superficial layers were found ; one with moderate electron dense amorphous granular substance layer, other with high electron dense fine granular substance layer, and another type of amorphous granular substance covered with high electron dense line of minute granules. (4) The osteoblasts in the marrow tissue neighboring implants and osteocytes in compact bone showed typical normal characteristics and in the marrow tissues some of lymphocytes and mast cells were observed. (5) The abscence of abnormal tissue reactions at a cellular level indicates a high degree of biocompatibility for the experimental titanium implant and basically no difference was found between functionally loaded and unloaded implants.

  • PDF

In vivo comparison between the effects of chemically modified hydrophilic and anodically oxidized titanium surfaces on initial bone healing

  • Lee, Hyo-Jung;Yang, Il-Hyung;Kim, Seong-Kyun;Yeo, In-Sung;Kwon, Taek-Ka
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.3
    • /
    • pp.94-100
    • /
    • 2015
  • Purpose: The aim of this study was to investigate the combined effects of physical and chemical surface factors on in vivo bone responses by comparing chemically modified hydrophilic sandblasted, large-grit, acid-etched (modSLA) and anodically oxidized hydrophobic implant surfaces. Methods: Five modSLA implants and five anodized implants were inserted into the tibiae of five New Zealand white rabbits (one implant for each tibia). The characteristics of each surface were determined using field emission scanning electron microscopy, energy dispersive spectroscopy, and confocal laser scanning microscopy before the installation. The experimental animals were sacrificed after 1 week of healing and histologic slides were prepared from the implant-tibial bone blocks removed from the animals. Histomorphometric analyses were performed on the light microscopic images, and bone-to-implant contact (BIC) and bone area (BA) ratios were measured. Nonparametric comparison tests were applied to find any significant differences (P<0.05) between the modSLA and anodized surfaces. Results: The roughness of the anodized surface was $1.22{\pm}0.17{\mu}m$ in Sa, which was within the optimal range of $1.0-2.0{\mu}m$ for a bone response. The modSLA surface was significantly rougher at $2.53{\pm}0.07{\mu}m$ in Sa. However, the modSLA implant had significantly higher BIC than the anodized implant (P=0.02). Furthermore, BA ratios did not significantly differ between the two implants, although the anodized implant had a higher mean value of BA (P>0.05). Conclusions: Within the limitations of this study, the hydrophilicity of the modSLA surface may have a stronger effect on in vivo bone healing than optimal surface roughness and surface chemistry of the anodized surface.

INFLUENCE OF TOPICAL IRRIGATION USING THE HA & PURE Ti IMPLANTS ON BONE FORMATION;A STUDY ON THE IRRADIATED RABBIT TIBIA (방사선 조사후 매식한 임프란트와 관주에 따른 골치유에 대한 비교연구)

  • Hong, Sung-Pal;Rhee, Gun-Joo;Cha, Yong-Doo;Oh, Se-Jong;Hyun, Jung-Min;Choi, Dong-Joo;Park, Young-Joo;Park, Jon-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.59-72
    • /
    • 2000
  • In this study, the rate of bone formation and the pattern of bone to implant contact surface around HA coated implant and pure Ti implant inserted into the irradiated tibia of rabbit were compared. Sixteen mongrel mature male rabbits were used as experimental animal. Each rabbit received 15 Gy of irradiation. Four weeks after irradiation, two holes were prepared on the tibia of each rabbit for placement of HA coated type and pure Ti type implants. Prior to implant placement, one group received steroid irrigation and the control group was similarly irrigated with normal saline. This was immediately followed by placement of the two different types of implants. Postoperatively, tetracycline was injected intramuscularly for 3 days. For fluorescent labelling, 3 days of intramuscular alizarine red injection was given. 2 weeks before sacrifice, followed by intramuscular calcein green on the last 3 days before specimen collection. Each rabbit was sacrificed on the second, fourth, sixth and eighth week after the implantation. The specimens were observed by the light microscope and the fluorescent microscope. The results were as follows; 1. All implants inserted into the irradiated tibia of rabbit were free from clinical mobility and no signs of bony resorption were noted around the site of implant placement. 2. Under the light microscope, new bone formation proceeded faster around implants that received steroid irrigation compared to the control group irrigated with saline. Bone to implant contact surface was greater in the steroid irrigated group than the saline irrigated group. Therefore, better initial stabilization was observed in the group pretreated with steroid irrigation. 3. Under the light microscope. HA coated implants showed broader bone to implant contact surface than pure Ti implants, and HA coated implants had better bone healing pattern than pure Ti implants. 4. In the steroid pretreated group, acceleration of bone formation was demonstrated by fluorescent microscopy around the 2, 4 weeks group and the 6 weeks HA coated implant group. The difference in the rate of bone formation proved to be statistically significant(P<0.05). Faster bone formation was noted in the saline irrigated group in the 6 weeks pure Ti implants and 8 weeks group. The difference was not statistically significant(P<0.05). 5. For the rabbits that were sacrificed on the second and fourth week after the implant placements, the rates of bone formation around HA coated implants proceeded faster than those around pure Ti implants under the fluorescent microscopy. For the rabbits that were sacrificed on the sixth week after the implant placements, the rates of bone formation around pure Ti implants proceeded faster than those around HA coated implants under the fluorescent microscopy. But this result did not show statistical significance (P<0.05) For the rabbits that were sacrificed on the eighth week after the implant placements, the rates of bone formation around HA coated implants proceeded faster than those around pure Ti implants under the fluorescent microscopy. This result was statistically significant (P<0.05).

  • PDF

The effect of various thread designs on the initial stability of taper implants

  • Park, Ju-Hee;Lim, Young-Jun;Kim, Myung-Joo;Kwon, Ho-Beom
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.1
    • /
    • pp.19-25
    • /
    • 2009
  • STATEMENT OF PROBLEM. Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc. PURPOSE. The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone(Group 1) and the rest of which were not engaged to inferior cortical wall(Group 2) by measuring the implant stability quotient(ISQ) and the removal torque value(RTV). MATERIAL AND METHODS. In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell $mentor^{(R)}$ and with removal torque using MGT50 torque gauge. RESULTS. In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants(P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not(P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2(P < .05). CONCLUSIONS. Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.