References
- Ericsson I, Johansson CB, Bystedt H, Norton MR. A histomorphometric evaluation of bone-to-implant contact on machine-prepared and roughened titanium dental implants: A pilot study in the dog. Clin Oral Implants Res 1994;5(4):202-206 https://doi.org/10.1034/j.1600-0501.1994.050402.x
- Webster TJ, Ergun C, Doremus RH, Siegel RW, Bizios R. Enhanced functions of osteoblast on nanophase ceramics. Biomaterials 2000;21:1803-10 https://doi.org/10.1016/S0142-9612(00)00075-2
- Webster TJ, Schandler LS, Siegel RW, Bizios R. Mechanics of enhanced osteoblast adhesion on nanophase alumina involve vitronectin. Tissue Eng 2001;7:291-310 https://doi.org/10.1089/10763270152044152
- Meredith, N., Shagaldi, F., alleyne, D., Sennerby, L., Cawley, P. The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia. Clin Oral Implants Res 1997b;8:234-243 https://doi.org/10.1034/j.1600-0501.1997.080310.x
- Sennerby L. Roos J Surgical determinants of clinical success of osseointegrated Prosthodont 1998;11:408- 420
- Sennerby L. Roos J. RFA: Measuring implant stability and osseointegration. Compendium 1998;19: 493-502
- Sennerby L. Friberg B. Linden B. Jemt T. Meredith N. A comparison of implant bone using RFA:European commission demonstration Project. RFA Symposium. 2002 Sweden
- Park CJ. A study on the change of implant stability using resonance frequency analysis SNUDH Dept of Pros. Unpublished 2003
- Berglundh T, Abrahamsson I, Lang NP, Lindhe J. De novo alveolar bone formation adjacent to endosseous implants. Clin Oral Implants Res 2003;14:251-262 https://doi.org/10.1034/j.1600-0501.2003.00972.x
- Misch CE. Density of bone: Effect on treatment plans, surgical approach, healing, and progressive bone loading. Int J Oral IMplantol 1990;6:23-31
- Sun L. Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: A review. J Biomed Mater Res 2001;58: 570-592 https://doi.org/10.1002/jbm.1056
- Tal H. Spontaneous early exposure of submerged implants.Ⅱ: Histopathology and histomorphometry of non-perforated mucosa covering submerged implants. J Periodontol 2000;71:1231-1235 https://doi.org/10.1902/jop.2000.71.8.1231
- Uchida M, Kim HM, Kokubo T, Fujibayashi S, Makamura T. Structural dependence of apatite formation on titania gels in a simulated body fluid. J Biomed Mater Res 2003;64:164-70
- Li D, Rerguson SJ, Beutler T, Cochran DL, Sittig C, Hirt HP, Buser D. Biomechanical coparison of the sandblasted and acid-etched and the achined and acid-etched titanium surface for dental implants. J Biomed Mater Res. 2002;60:325-332 https://doi.org/10.1002/jbm.10063
- Cochran DL, Schenk RK, Lussi A, Higginbottom FL, Buser D, Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible. J Biomed Mater Res 1998;40:1-11 https://doi.org/10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO;2-Q
- Rocci A, Martignoni M, Burgos PM, Gottlow J, Sennerby L. Histology of retrieved immediately and early loaded oxidized implants: light microscopic observations after 5 to 9 months of loading in the posterior mandible. Clin Implant Dent Related Res 2003;5(Suppl 1):88-98 https://doi.org/10.1111/j.1708-8208.2003.tb00020.x
- Parel SM, Triplett RG. Immediate fixture placement: a treatment planning alternative. Int J Oral Maxillofac Implants 1990;5(4):337-345
- Meredith N, Friberg B, Sennerby L. Araricio C. Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability. Int J Prosthodontics 1998;11: 269-275
- Sennerby L. Resonance frequency measurements of implant stability in vivo: A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res 1997;8:226-333
- Derhami K, Wolfaardt JF, Dent M, Faulkner G. Grace M. Assessment of the Periotest device in baseline mobility measurements of craniofacial implants. Int J Oral Maxillofac Implants 1995;10:221-229
- Schatzker J, Horne JG, Sumnet SG. The effect of movement on holding power of screws in bone. Clin Orthop 1975;111:257-262 https://doi.org/10.1097/00003086-197509000-00032
- Papalexiou V, Novaes AB Jr, Grisi MFM, Souza SSLS. Influence of implant microstructure on the dynamics bone healing round immediate implants placed into periodontally infected sites. Clin Oral Impl Res 2004;15:44-53 https://doi.org/10.1111/j.1600-0501.2004.00995.x