• 제목/요약/키워드: Bone micro-architecture

검색결과 12건 처리시간 0.027초

Three-dimensional microstructure of human alveolar trabecular bone: a micro-computed tomography study

  • Lee, Ji-Hyun;Kim, Hee-Jin;Yun, Jeong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제47권1호
    • /
    • pp.20-29
    • /
    • 2017
  • Purpose: The microstructural characteristics of trabecular bone were identified using micro-computed tomography (micro-CT), in order to develop a potential strategy for implant surface improvement to facilitate osseointegration. Methods: Alveolar bone specimens from the cadavers of 30 humans were scanned by high-resolution micro-CT and reconstructed. Volumes of interest chosen within the jaw were classified according to Hounsfield units into 4 bone quality categories. Several structural parameters were measured and statistically analyzed. Results: Alveolar bone specimens with D1 bone quality had significantly higher values for all structural parameters than the other bone quality categories, except for trabecular thickness (Tb.Th). The percentage of bone volume, trabecular separation (Tb.Sp), and trabecular number (Tb.N) varied significantly among bone quality categories. Tb.Sp varied markedly across the bone quality categories (D1: $0.59{\pm}0.22mm$, D4: $1.20{\pm}0.48mm$), whereas Tb.Th had similar values (D1: $0.30{\pm}0.08mm$, D4: $0.22{\pm}0.05mm$). Conclusions: Bone quality depended on Tb.Sp and number-that is, endosteal space architecture-rather than bone surface and Tb.Th. Regardless of bone quality, Tb.Th showed little variation. These factors should be taken into account when developing individualized implant surface topographies.

돼지 하악 과두의 해면골에서 유한요소분석법으로 예측한 방향에 따른 탄성율과 3차원 골 미세지표 간의 상관관계 (The relationship between 3D bone architectural parameters and elastic moduli of three orthogonal directions predicted from finite elements analysis)

  • 박관수;이삼선;허경회;이원진;허민석;최순철
    • Imaging Science in Dentistry
    • /
    • 제38권2호
    • /
    • pp.81-87
    • /
    • 2008
  • Purpose: To investigate the relationship between 3D bone architectural parameters and direction-related elastic moduli of cancellous bone of mandibular condyle. Materials and Methods: Two micro-pigs (Micro-$pig^R$, PWG Genetics Korea) were used. Each pig was about 12 months old and weighing around 44 kg. 31 cylindrical bone specimen were obtained from cancellous bone of condyles for 3D analysis and measured by micro-computed tomography. Six parameters were trabecular thickness (Tb. Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI), degree of anisotropy (DA) and 3-dimensional fractal dimension (3DFD). Elastic moduli of three orthogonal directions (superior-inferior (SI), medial-lateral (ML), andterior-posterior (AP) direction) were calculated through finite element analysis. Results: Elastic modulus of superior-inferior direction was higher than those of other directions. Elastic moduli of 3 orthogonal directions showed different correlation with 3D architectural parameters. Elastic moduli of SI and ML directions showed significant strong to moderate correlation with BV/TV, SMI and 3DFD. Conclusion: Elastic modulus of cancellous bone of pig mandibular condyle was highest in the SI direction and it was supposed that the change into plate-like structure of trabeculae was mainly affected by increase of trabeculae of SI and ML directions.

  • PDF

돼지 하악골의 micro-CT영상에서 추출한 3차원 골미세구조와 골강도 사이의 상관관계 (Relationship between trabecular strength and three-dimensional architecture in the pig mandible using microcomputed tomography)

  • 허경회;박무순;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제35권3호
    • /
    • pp.167-173
    • /
    • 2005
  • Purpose : To investigate the relationship between three-dimensional (3D) bone imaging parameters and trabecular strength in the mandible. Materials and Methods : Bone specimens were obtained from the mandibles of five male pigs weighing around 110 kg each. Of those, 43 samples were selected for 3D analysis and measured by micro-computed tomography. The five morphometric parameters were trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DA). Through destructive mechanical testing, strength parameters were obtained. Results : BV/TV, SMI, BS/BV, and Tb.Th showed significant correlations with strength parameters. DA did not show any correlation with the other parameters. In multiple linear regression analysis, BV/TV alone explained $43\%$ of the variance in Young's modulus. By stepwise inclusion of SMI, the variance in the Young's modulus was better explained up to $52\%$. Conclusions : Predicting trabecular strength in the mandible through architectural analysis would be possible. Further study is needed to establish the tendency and variety of trabecular architecture and strength according to the locations within the mandible.

  • PDF

Socket preservation using eggshell-derived nanohydroxyapatite with platelet-rich fibrin as a barrier membrane: a new technique

  • Kattimani, Vivekanand Sabanna;Lingamaneni, Krishna Prasad;Kreedapathi, Girija Easwaradas;Kattappagari, Kiran Kumar
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권6호
    • /
    • pp.332-342
    • /
    • 2019
  • Objectives: Socket grafting is vital to prevent bone resorption after tooth extraction. Several techniques to prevent resorption have been described, and various bone graft substitutes have been developed and used with varying success. We conducted this pilot study to evaluate the performance of nanohydroxyapatite (nHA) derived from chicken eggshells in socket preservation. Materials and Methods: This was a prospective, single center, outcome assessor-blinded evaluation of 23 sockets (11 patients) grafted with nHA and covered with platelet-rich fibrin (PRF) membrane as a barrier. Bone width and radiographic bone density were measured using digital radiographs at 1, 12, and 24 weeks post-procedure. Postoperative histomorphometric and micro-computed tomography (CT) evaluation were performed. The study protocol was approved by the Institutional Ethics Committee. Results: All patients had uneventful wound healing without graft material displacement or leaching despite partial exposure of the grafted socket. Tissue re-epithelialized with thick gingival biotype (>3 mm). Width of the bone was maintained and radiographic density increased significantly with a trabecular pattern (73.91% of sockets) within 12 weeks. Histomorphometric analysis showed 56.52% Grade 3 bone formation and micro-CT analysis revealed newly formed bone with interconnecting trabeculae. Conclusion: Use of a PRF membrane with nHA resulted in good bone regeneration in sockets. Use of a PRF membrane prevents periosteal-releasing incisions for primary closure, thereby facilitating the preservation of keratinized mucosa and gingival architecture. This technique, which uses eggshell-derived nHA and PRF membrane from the patient's own blood, is innovative and is free of disease transfer risks. nHA is a promising economic bone graft substitute for bone regeneration and reconstruction because of the abundant availability of eggshell waste as a raw material.

성장 중인 쥐에서 음식물의 경도가 하악 과두의 해면골에 미치는 영향 : 미세전산화 단층촬영을 이용한 연구 (THE EFFECTS OF DIETARY CONSISTENCY ON THE TRABECULAR BONE ARCHITECTURE IN GROWING MOUSE MANDIBULAR CONDYLE : A STUDY USING MICRO-CONFUTED TOMOGRAPHY)

  • 윤석희;이상대;김정욱;이상훈;한세현;김종철
    • 대한소아치과학회지
    • /
    • 제31권2호
    • /
    • pp.228-235
    • /
    • 2004
  • 하악 과두의 발달과 증식은 측두하악관절 부위의 생역학적 환경의 변화에 따라 변경될 수 있다. 이 부위에 전달되는 생역학적 하중은 섭취하는 음식물의 경도를 다르게 함으로써 변화시킬 수 있다. 이번 연구의 목적은 성장 중인 쥐에서 부드러운 음식물의 섭취에 의해 저작력을 변화시키는 것이 하악 과두의 해면골의 형태를 변화시킬 수 있는지 미세전산화 단층촬영을 이용하여 분석하는 것이었다. 생후 21일 된 C57BL/6 쥐 36마리를 무작위로 두 그룹으로 나누었다. 8주 동안 대조군의 쥐들은 일반적인 딱딱한 덩어리의 사료를, 실험군의 쥐들은 덩어리의 사료를 잘게 갈은 후 물과 섞어 부드럽게 만들어 먹였다. 또한 실험군의 쥐들의 하악 절치를 일주일에 두 번씩 잘라서 짧게 만들었다. 8주 후 모든 쥐들을 희생하여 우측 하악 과두를 준비하였다. 미세전산화 단층촬영과 삼차원 영상 분석프로그램을 이용하여 하악 과두 해면골의 bone volume(BV), bone surface(BS), total volume(TV) bone volume fraction(BV/TV), surface to volume ratio(BS/BV), trabecular thickness(Tb. Th.), structure model index(SMI)와 degree of anisotropy(DA)를 측정하고 이들 값으로부터 trabecular number(Tb. N.)와 trabecular separation (Tb. Sp.)을 계산하였다 미세전산화 단층영상을 얻은 후 하악 과두의 조직 표본을 만들었다. 연구 결과는 다음과 같았다. 1. Bone volume fraction(BV/TV), trabecular thickness(Tb. Th.)와 trabecular number(Tb. N.)가 대조군에 비해 부드러운 음식을 먹인 실험군에서 유의하게 감소되었다(p<0.05). 2. Trabecular separation(Tb. Sp.)은 부드러운 음식을 먹인 실험군에서 유의하게 증가하였다(p<0.05). 3. Surface to volume ratio(BS/BV), structure model index(SMI), degree of anisotropy (DA)는 두 군 사이에 유의한 차이를 보이지 않았다(p>0.05). 4. 조직 절편을 관찰한 결과, 부드러운 사료를 먹인 실험군에서 하악 과두의 연골층의 증식 층과 전체 두께가 상당히 감소하였다.

  • PDF

Three-dimensional bio-printing and bone tissue engineering: technical innovations and potential applications in maxillofacial reconstructive surgery

  • Salah, Muhja;Tayebi, Lobat;Moharamzadeh, Keyvan;Naini, Farhad B.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.18.1-18.9
    • /
    • 2020
  • Background: Bone grafting has been considered the gold standard for hard tissue reconstructive surgery and is widely used for large mandibular defect reconstruction. However, the midface encompasses delicate structures that are surrounded by a complex bone architecture, which makes bone grafting using traditional methods very challenging. Three-dimensional (3D) bioprinting is a developing technology that is derived from the evolution of additive manufacturing. It enables precise development of a scaffold from different available biomaterials that mimic the shape, size, and dimension of a defect without relying only on the surgeon's skills and capabilities, and subsequently, may enhance surgical outcomes and, in turn, patient satisfaction and quality of life. Review: This review summarizes different biomaterial classes that can be used in 3D bioprinters as bioinks to fabricate bone scaffolds, including polymers, bioceramics, and composites. It also describes the advantages and limitations of the three currently used 3D bioprinting technologies: inkjet bioprinting, micro-extrusion, and laserassisted bioprinting. Conclusions: Although 3D bioprinting technology is still in its infancy and requires further development and optimization both in biomaterials and techniques, it offers great promise and potential for facial reconstruction with improved outcome.

형태학적 지수에 기반한 뼈 미세구조의 평가 (Evaluation of Bone Micro-architecture based on histomorphometry)

  • 박상철
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2005년도 춘계공동학술대회 발표논문
    • /
    • pp.862-865
    • /
    • 2005
  • 해면골에 대한 평가는 일반적으로 골밀도를 기준으로 평가하지만, 골밀도는 뼈의 특성을 70-80% 정도만 설명하는 것으로 알려져 있다. 이에 따라 골밀도로 설명이 되지 않는 나머지 특성을 뼈 미세구조의 형태학적 특성을 이용하여 설명하려는 노력이 생체역학 분야에서 오랫동안 있어 왔다. 본 연구는 CAD/CAM 분야의 feature extraction 기술을 이러한 생체역학 분야에 접목함으로써 뼈의 미세구조 평가를 위한 새로운 형태학적 지수 개발의 가능성을 탐색하고자 한다.

  • PDF

Effect of Korean Red Ginseng on radiation-induced bone loss in C3H/HeN mice

  • Lee, Jin-Hee;Lee, Hae-June;Yang, Miyoung;Moon, Changjong;Kim, Jong-Choon;Bae, Chun-Sik;Jo, Sung-Kee;Jang, Jong-Sik;Kim, Sung-Ho
    • Journal of Ginseng Research
    • /
    • 제37권4호
    • /
    • pp.435-441
    • /
    • 2013
  • This study investigated the effects of Korean Red Ginseng (KRG) on radiation-induced bone loss in C3H/HeN mice. C3H/HeN mice were divided into sham and irradiation (3 Gy, gamma-ray) groups. The irradiated mice were treated for 12 wk with vehicle, KRG (per os, p.o.) or KRG (intraperitoneal). Serum alkaline phosphatase (ALP), tartrate-resistant acid phosphatase, estradiol level, and biomechanical properties were measured. Tibiae were analyzed using micro-computed tomography. Treatment of KRG (p.o., 250 mg/kg of body weight/d) significantly preserved trabecular bone volume, trabecular number, structure model index, and bone mineral density of proximal tibia metaphysic, but did not alter the uterus weight of the mice. Serum ALP level was slightly reduced by KRG treatment. However, grip strength, mechanical property, and cortical bone architecture did not differ among the experimental groups. The results indicate that KRG can prevent radiation-induced bone loss in mice.

Finite element analysis of the behavior of elliptical cracks emanating from the orthopedic cement interface in total hip prostheses

  • Ali Benouis;Mohammed El Sallah Zagane;Abdelmadjid Moulgada;Murat Yaylaci;Djafar Ait Kaci;Merve Terzi;Mehmet Emin Ozdemir;Ecren Uzun Yaylaci
    • Structural Engineering and Mechanics
    • /
    • 제89권5호
    • /
    • pp.539-547
    • /
    • 2024
  • This study examines crack behavior within orthopedic cement utilized in total hip replacements through the finite element method. Its main goal is to compute stress intensity factors (SIF) near the crack tip. The analysis encompasses two load types, static and dynamic, applied to a crack starting from the interface between the cement and bone. Specifically, it investigates SIFs under mixed mode conditions during three activities: normal walking, climbing upstairs, and downstairs. The results highlight that a crack originating from a micro-interface under substantial loading can cause cement damage, leading to prosthetic loosening. Stress intensity factors in modes I, II, and III are influenced by the crack tip's orientation and location in the bone cement, with a 90° orientation yielding notably higher values across all three modes.