• Title/Summary/Keyword: Bone Development

Search Result 1,097, Processing Time 0.031 seconds

A Study of the Osteoporosis-related Lifestyle and Health Promotion Behavior of University and College Female Student (여대생의 골다공증 관련 생활습관과 건강증진 행위에 관한 조사연구)

  • Kim, Young-Mi;Kim, Myung-Hee
    • Journal of muscle and joint health
    • /
    • v.9 no.1
    • /
    • pp.53-67
    • /
    • 2002
  • Osteoporosis is a age-related metabolic disorder. Currently there is no cure, but there are measures that can prevent or deter the development of osteoporosis. Futhermore lifestyle among risk factors of osteoporosis may be modifiable. Osteoporotic preventive health promotion behavior may be more effective at early adult when make formation of peak bone mass. The purpose of this study was to identify of relation between the demographic variable, osteoporosis-related lifestyles and the health promotion behavior of University and College Female Students. The results were followed: 1. Demographic variables according to the health promotion behavior were significantly difference with age, body height, religion and income. 2. Osteoporosis-related lifestyles according to the health promotion behavior were significantly difference with element school milk intake, current milk intake, exercise and caffeine intake. 3. Health promotion behavior was positively correlation with age, body weight, height income, element school and current milk intake and exercise.

  • PDF

A Study of Geometrical Theory For Maxillary Sinus Projection in Children (소아 상악동 촬영의 기하학적 이론에 관한 연구)

  • Jeon, H.G.;Kwon, Y.H.;Lee, B.S.
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.51-54
    • /
    • 1997
  • This study is to evaluate the individual angulation on maxlliary sinus projection and establishing angulation in children by new geometrical method. There were two groups, which are 60 cases in children (ranged from 1yr to 3yrs, 3yrs to 8yrs, 8yrs to 12yrs) and 50 cases in adults. We analyzed the true lateral maxillary sinus film of total 110 patients using new geometrical method. We demonstrated an angle of maxillary sinus projection. Arithmetical average angulation in adults is 36.56 degrees that accord with Waters. Whereas it is not valid during development of facial bone in childhood. The individual range of angulation according to age was that 1yr to 3yrs is 50-47 degrees, 3yrs to 8yrs is 47-40 degrees, 8yrs to 12yrs is 40-38 degrees. This geomatrical method will be useful in establishing angulation for maxillary sinus profection.

  • PDF

A Development of Fuzzy Logic-Based Evaluation Model for Traffic Accident Risk Level (퍼지 이론을 이용한 교통사고 위험수준 평가모형)

  • 변완희;최기주
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.2
    • /
    • pp.119-136
    • /
    • 1996
  • The evaluation of risk level or possibility of traffic accidents is a fundamental task in reducing the dangers associated with current transportation system. However, due to the lack of data and basic researches for identifying such factors, evaluations so far have been undertaken by only the experts who can use their judgements well in this regard. Here comes the motivation this thesis to evaluate such risk level more or less in an automatic manner. The purpose of this thesis is to test the fuzzy-logic theory in evaluating the risk level of traffic accidents. In modeling the process of expert's logical inference of risk level determination, only the geometric features have been considered for the simplicity of the modeling. They are the visibility of road surface, horizontal alignment, vertical grade, diverging point, and the location of pedestrain crossing. At the same time, among some inference methods, fuzzy composition inference method has been employed as a back-bone inference mechanism. In calibration, the proposed model used four sites' data. After that, using calibrated model, six sites' risk levels have been identified. The results of the six sites' outcomes were quite similar to those of real world other than some errors caused by the enforcement of the model's output. But it seems that this kind of errors can be overcome in the future if some other factors such as driver characteristics, traffic environment, and traffic control conditions have been considered. Futhermore, the application of site's specific time series data would produce better results.

  • PDF

Digital Elderly Human Body Modeling Part I : Standard Anthropometry and Exterior/Interior Geometries (디지털 고령 인체 모델 구축 Part I : 표준 Anthropometry 및 내외형상)

  • Han, Ji-Won;Choi, Hyung-Yun;Yoon, Kyong-Han;Park, Yo-Han
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.1
    • /
    • pp.96-104
    • /
    • 2009
  • An anatomically detailed elderly human body model is under development. Using the anthropometric database of domestic nation-wide size survey, SizeKorea, a standard size and shape of 50th %tile elderly was constructed. Through the local recruitment process, a male volunteer with 71 years of age, 163cm of height and 63kg of weight has been selected. The exterior (skin) and interior (skeleton and organ) geometries were acquired from whole body 3D laser scan and various medical images such as CT, X-ray, and Ultrasonic of the volunteer. A particular attention has been paid into the combining process of exterior and interior geometries especially for joint articulation positions since they were measured at different postures (sitting vs. supine). A whole ribcage of PMHS which possessed similar anthropometry and age of standard 50th %tile elderly was prepared and dissected for the precise gauge of cortical rib bone thickness distributions. After completing the morphological construction of elderly human body, the finite element modeling will be processed by meshing elements and assigning mechanical properties to various biological tissues which reflect the aging effect.

Development of the External Fixator for a Bone Fracture (골절치료용 체외고정기기 개발을 위한 연구)

  • 윤희열;한정수;한창수
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.4
    • /
    • pp.317-322
    • /
    • 2002
  • In this paper, the problems of the external fixator that have developed for a distal radius fracture so far are analyzed, and accordingly, the characterizations, which must have a prototype, are arranged. C-Arm is used. This instrument makes it possible for the real play of the internal body by x-ray permeability. From this data. it is possible to induce important design factors Finally. a basic mechanism, which has to be applied, is decided, and the Solid Edge program, which uses a 3-D design tool, completes then total instrument design.

Strength Properties of Sandwich Panel core using Cellular lightweight Aggregate according to Curing Temperature (양생온도에 따른 다공성 경량골재를 활용한 샌드위치 패널심재의 강도 특성)

  • 노정식;김대규;도정윤;문경주;소양섭
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.35-38
    • /
    • 2003
  • The purpose of this study is to investigate the manufacture of light weight concrete panel using the artificial light-weight aggregate as a part of the substitution of foamed styrene and polyurethane because of narrow allocable temperature Bone in use. The experimental parameter of this study is 40, 60 and 8$0^{\circ}C$ of curing temperature at 100% relative humidity and the type of admixture such as cement, 6mm glass fiber and St/BA emulsion. Testing item is compressive and flexural strength and strength of specimen cured at standard condition is compared to that of specimen cured at 40, 60 and 8$0^{\circ}C$ of curing temperature at 100% relative humidity. As a result or this, it was revealed that the maximum or strength is developed in 6$0^{\circ}C$ or cure temperature at 100% relative humidity in case of the most of the specimen. Specimens modified by St/BA emulsion show the highest development of strength dependent on the curing tmeperature. So, it seems to be effective that evaporation curing method shoud be considered to curing the specimen as the panel core.

  • PDF

Biomechanical Effects of Facial Mask according to Direction of Forces on the Craniofacial Complex : A Finite Element Study (두개안면복합체에서 Face Mask의 견인방향에 따른 생역학적 연구 : 유한요소법 연구)

  • Hyun, Ha-Young;Cha, Kyung-Suk;Chung, Dong-Hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.359-371
    • /
    • 2007
  • Recently, many studies were reported accurate analysis of facemask effect due to the development of the personal computers and computer programs. The aim of this study is appropriate protraction direction of facemask using finite element study with computer aided design and computer aided measurement. The construction of the three dimensional FEM was based on the computer tomography(CT) scans of 13.5 year-old male subject. Protraction force of 500 mg was applied at 0, 30, 60 and 90 degrees downwards to the Frankfort horizontal plane, and maxillary displacement and stress distribution were measured. When 60 degree force was applied, it showed forward movement of premolar roots area and downward movement of anterior nasomaxillary area, and others showed clockwise rotation movement of the nasomaxillary complex. Finally, we can produce the protraction of maxillary bone without rotation of maxilla about 60 degrees.

Hierarchical porous carbon nanofibers via electrospinning

  • Raza, Aikifa;Wang, Jiaqi;Yang, Shan;Si, Yang;Ding, Bin
    • Carbon letters
    • /
    • v.15 no.1
    • /
    • pp.1-14
    • /
    • 2014
  • Carbon nanofibers (CNFs) with diameters in the submicron and nanometer range exhibit high specific surface area, hierarchically porous structure, flexibility, and super strength which allow them to be used in the electrode materials of energy storage devices, and as hybrid-type filler in carbon fiber reinforced plastics and bone tissue scaffold. Unlike catalytic synthesis and other methods, electrospinning of various polymeric precursors followed by stabilization and carbonization has become a straightforward and convenient way to fabricate continuous CNFs. This paper is a comprehensive and brief review on the latest advances made in the development of electrospun CNFs with major focus on the promising applications accomplished by appropriately regulating the microstructural, mechanical, and electrical properties of as-spun CNFs. Additionally, the article describes the various strategies to make a variety of carbon CNFs for energy conversion and storage, catalysis, sensor, adsorption/separation, and biomedical applications. It is envisioned that electrospun CNFs will be the key materials of green science and technology through close collaborations with carbon fibers and carbon nanotubes.

Development and Mechanical Performance Evaluation of Lumbar Porous Interbody Fusion Cage (요추부 다공성 추간체유합보형재의 개발 및 기계적 성능 평가)

  • Ahn, Yoon-Ho;Yoo, Kyeong-Joo;Park, Kwang-Min;Cha, Eun-Jong;Kim, Kyung-Ah;Ahn, Kyoung-Gee
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.14-21
    • /
    • 2020
  • Recently, porous additive manufactured(AM) cages have been introduced to provide more desirable stiffness and may be beneficial to bone ingrowth. They are designed to attempt to reduce the subsidence problem of traditional titanium cage and to get osseointegrative property that PEEK doesn't have. This study was performed to evaluate the mechanical performance of newly developed lumbar porous AM cages. Three types of mechanical tests were performed in accordance with the ASTM standards: Static compression, compression-shear, and subsidence tests. The porous AM cages with 60% porosity showed similar device stiffness and strength as the various products submitted to FDA 510(k), and their wider contact area improved the subsidence test results by about 50%. In conclusion, the porous AM cages developed in this study were considered mechanically safe and could be an alternative to solid PEEK cages.

Current Status of Health Screening in Korea (한국의 건강검진 현황)

  • Jo, Han-Ik
    • Journal of Korea Association of Health Promotion
    • /
    • v.2 no.2
    • /
    • pp.215-230
    • /
    • 2004
  • Along with a development of medical technology, a variety of tests, such as laboratory tests, x-ray and endoscopies are being used in health screening tests. As the tests determine the quality of health screening, test items and methods should be carefully selected. This study was to get hold of the test items of major health screening programs in Korea. Most of the health screening programmes focused upon detection of risk factors and diagnosis of life-style related diseases(diabetes, hypertension, cardiovascular diseases, hypercholesterolemia, overweight, drinking, smoking, cerebrovascular diseases, osteoporosis) ,cancers(stomach, cervix, lung, breast, liver, colon, prostate, ovary, pancreas, thyroid, esophagus), infectious diseases (hepatitis, tuberculosis, sexually-transmitted diseases, parasites),chronic obstructive respiratory diseases, chronic renal diseases(bacteriuria, hematuria, proteinuria), anemia, glaucoma, hearing loss, Alzheimer disease, stress, early Psychiatric diseases. The health screening tests were basic physical examination, basic laboratory tests(CBC, urinalysis, liver function tests, lipid tests, glucose, HbAlc, uric acid, electrolytes, serological tests(HBsAg, HBs-Ab, HCV-Ab, HIV-Ab, VDRL) EKG, x-ray(chest PA, CT), endoscopy (gastroscopy, colonoscopy) , sonography(abdormen, thyroid, pelvis, breast) , cytology(cervix) ,bone density, tumor markers(NMP22, alpha-FP, CEA, CA-19-9, CA12S, PSA) and eye tests. Advanced technologies, like CT, PET, MIRI, MIRI/Angio, molecular testings) were widely usedin hospital health screening programmes. In summary, a variety of were utilized by stages or programmes, however a few subjects. tests were utilized in health screening in Korea. Those tests according to sex and age in most of health screening program used tests to excess disregarding health screening subject.

  • PDF