• 제목/요약/키워드: Body temperature measurement

검색결과 223건 처리시간 0.034초

방전플라즈마 소결 공정을 이용한 스퍼터링 타겟용 타이타늄 소결체 제조 및 특성 평가 (Fabrication and Evaluation Properties of Titanium Sintered-body for a Sputtering Target by Spark Plasma Sintering Process)

  • 이승민;박현국;윤희준;양준모;우기도;오익현
    • 대한금속재료학회지
    • /
    • 제49권11호
    • /
    • pp.845-852
    • /
    • 2011
  • The Spark Plasma Sintering(SPS) method offers a means of fabricating a sintered-body having high density without grain growth through short sintering time and a one-step process. A titanium compact having high density and purity was fabricated by the SPS process. It can be used to fabricate a Ti sputtering target with controlled parameters such as sintering temperature, heating rate, and pressure to establish the optimized processing conditions. The compact/target(?) has a diameter of ${\Phi}150{\times}6.35mm$. The density, purity, phase transformation, and microstructure of the Ti compact were analyzed by Archimedes, ICP, XRD and FE-SEM. A Ti thin-film fabricated on a $Si/SiO_2$ substrate by a sputtering device (SRN-100) was analyzed by XRD, TEM, and SIMS. Density and grain size were up to 99% and below $40{\mu}m$, respectively. The specific resistivity of the optimized Ti target was $8.63{\times}10^{-6}{\Omega}{\cdot}cm$.

생체 센서 시스템을 이용한 실시간 원격 홈 네트워크 시스템 (Real time remote management for home network system using bio-physical sensor)

  • 김정래
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권1호
    • /
    • pp.117-124
    • /
    • 2011
  • 본 논문은 생체 센서 시스템(bio-physical sensor system)을 이용하여 홈 네트워크 시스템을 구성하고, 생체 신호가 전달되도록 생체 신호 원격용 네트워크를 구현하였다. 측정 시스템의 구성조건은 시각(Vision), 체성감각(Somatosensory), 전정기관(Vestibular), 중추신경계통(CNS)의 변위점에서 평가하고, 맥박(Heart Rate), 체온(Temperature), 체중(Weight)을 기본 측정항목에 사용하였다. 주파수 변동에 따른 0.01 단위로 측정하여 평균값을 가지고 기준치에 비교하여 설정환경을 구성하고 측정값을 결정하였다. 생체 신호는 신체의 균형조절기능인 신경생리학적 감각처리 및 운동 출력기전으로 시각, 체성감각, 전정기관, 중추신경계통, 체질량지수(BMI)의 신체적 감각 기관의 수용체들 간의 운동에 대한 균형과 자세를 통한 기준으로 정상적인 균형 조절 상태와 균형의 크기 형태로 구분하고, 건강의 상태를 확인하도록 의미를 부여하였다. 본 연구의 결과로 제안한 홈 네트워크를 통해 헬스 센터 및 건강관리 중앙 시스템에 단말기를 통하여 전송됨으로 전문가을 통한 건강 관리시스템이 진행되는 결과를 얻을 수 있고, 다양한 신체적 파라메타를 통한 원격네트워크 모니터링 기능의 관리시스템이 형성 될 것으로 추론 할 수 있다.

Swan-Ganz Catheter를 이용한 심폐기능 이상자의 정확한 Cardiac Output 측정 플랫폼 개발 (Cardiac Output Measurement Platform Development Using Swan-Ganz Catheter in Cardiopulmonary Patients with More Accurate)

  • 정용현;나상신;김영길
    • 한국정보통신학회논문지
    • /
    • 제15권7호
    • /
    • pp.1591-1597
    • /
    • 2011
  • 본 논문에서는 심폐기능에 이상이 있는 중환자의 상태를 진단하거나 치료 방향을 정하기 위하여 심박 출량을 측정하는 플랫폼 구현에 관한 연구로써, 센서가 내장된 Swan-Ganz Catheter를 체내에 삽입 후, 생리식염수를 투입하여 생기는 온도변화량을 열희석법을 이용하여 심박출량을 구하는 방법을 사용한다. Swan-Ganz Catheter는 온도센서와 압력센서를 포함하고 있으며 이를 통해 입력되는 센서 값을 보다 세밀하게 수집한다면 심박출량, 전선 및 폐혈관저항, 산소소모량 등을 보다 정확하게 계산해 낼 수가 있으므로 환자의 상태를 보다 정확하게 진단 및 치료가 가능하게 한다.

반환부하법에 의한 옥외 주상용 몰드변압기의 과전열화 특정 (The Energized Aging Property of Pole Mount Mold transformer by Back-to-back Method)

  • 황보국;조한구;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.484-487
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. In this paper, the proto type mold transformer of 50kVA class is investigated by routine, type, special test. The outdoor energized aging test is investigated by back-to-back method to verify the long time performance of pole mold transformer. The aging process of transformer is analyzed by various diagnosis method such as DC voltage-current test, $tan{\delta}$, Meggar measurement, winding temperature and etc.

  • PDF

Haar Cascade 결괏값 선별 알고리즘을 통한 마스크 착용 여부와 발열 체크 (The Use of Haar Cascade Result selection algorithm to check Wearing Masks and Fever Abnormality)

  • 김의정
    • 한국정보통신학회논문지
    • /
    • 제26권2호
    • /
    • pp.193-198
    • /
    • 2022
  • 최근 코로나19를 예방하기 위해 마스크 착용 유무와 체온을 확인하는 곳이 많아졌다. 그러나 이러한 것은 사람이 수동으로 측정하거나 한 명씩 기계 앞에서 측정하는 방식이 대부분이므로 측정 방식에 따라 결과가 달라지고 인력 낭비가 발생한다. 또한 기계는 일반적으로 최고 온도만을 측정하므로 발열의 기준 또한 신뢰할 수 없다. 입구에 사람이 몰려 병목이 발생할 수 있으며 측정 장소는 대부분 입구 하나이므로 확진자의 동선 추적시에도 불편하다. 따라서 본 연구에서는 발열자와 마스크 미착용자를 카메라, 열화상 카메라, Haar Cascade 및 결괏값 선별 알고리즘을 활용하여 자동으로 분류하고 실시간으로 알려 전염병 확산을 억제하는 방법에 대해 제안하고자 한다.

Design of A Downlink Power Control Scheme in Unequal Error Protection Multi-Code CDMA Mobile Medicine System

  • Lin, Chin-Feng;Lee, Hsin-Wang;Hung, Shih-Ii;Li, Ching-Yi
    • 한국정보기술응용학회:학술대회논문집
    • /
    • 한국정보기술응용학회 2005년도 6th 2005 International Conference on Computers, Communications and System
    • /
    • pp.335-338
    • /
    • 2005
  • In this paper, we propose a downlink power control scheme to apply in the unequal error protection multi-code CDMA mobile medicine system. The mobile medicine system contains (i) blood pressure and body temperature measurement value, (ii) ECG medical signals measured by the electrocardiogram device, (iii) mobile patient's history, (iv) G.729 audio signal, MPEG-4 CCD sensor video signal, and JPEG2000 medical image. By the help of the multi-code CDMA spread spectrum communication system with downlink power control scheme and unequal error protection strategy, it is possible to transmit mobile medicine media and meet the quality of service. Numerical analysis and simulation results show that the system is a well transmission platform in mobile medicine.

  • PDF

적외선 측정 기법을 이용한 초음속 유동내 열전달 측정 (Heat Transfer Measurement in a Supersonic Flowfield by an Infra-red Thermography)

  • 유만선;이종주;송지운;조형희
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.359-362
    • /
    • 2006
  • 초음속 유동내 노출된 표면에서의 열전달 특성 파악을 위하여 적외선 측정 방법이 적용되었다. 등열유속 조건을 만족하는 표면 온도를 적외선 카메라로 촬영하여 이로부터 대류 열전달 계수를 계산하였으며, 실린더가 설치된 표면 근방에서 증가된 열전달 계수 분포를 도출해 낼 수 있었다.

  • PDF

평판 투명 물체의 형상측정을 위한 비접촉식 광센서 개발 (Development of a noncontact optical sensor for measuring the shape of transparent plates)

  • 윤상필;유영기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.214-214
    • /
    • 2000
  • This paper deals with the non contact optical sensor to measure the shape of transparent plates such as glass panel of LCD(Liquid Crystal Display). The conventional methods to obtain the shape or thickness of a transparent plates are contact type sensor such as LVOT(Linear Variable Differential Transformer). Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition, the high temperature glass casting makes the size of sensor body changed. These reasons makes the sensor degraded. In this paper, to overcome these problem, we proposed a low cost noncontact optical sensor this is composed of the Hologram laser unit of a CD-Pickup and a plastic lens. To evaluate the performance of the proposed optical sensor, a series of experiments were performed for various measurement condition. Based upon observation of the experimental result, the developed sensor shows good result for measuring the shape of transparent plates.

  • PDF

딥러닝 알고리즘을 활용한 마스크 착용 판별 및 체온 측정 시스템 구현 (Implementation of facemask wearing identification and body temperature measurement system using deep learning)

  • 방민기;김도연;최다영;이준범;정영석
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2021년도 제64차 하계학술대회논문집 29권2호
    • /
    • pp.523-524
    • /
    • 2021
  • COVID-19 확산으로 인해 우리나라는 공공장소 출입 시 마스크 착용이 의무화되었고, 체온이 37.5℃ 이상일 경우 발열로 간주하여 출입을 금지함에 따라 이를 효율적으로 검사할 수 있는 자동화 시스템을 개발하고자 한다. 이를 위해 다양한 각도, 마스크의 착용 위치에 따른 자료를 수집하여 모델에 적용하였고, 실시간 영상은 96.5%의 높은 정확도를 보였고, 영상 처리 추론 속도는 28fps임을 확인했다. 본 논문은 딥러닝 알고리즘을 활용한 마스크 착용 판별 및 체온 측정 시스템을 제시한다.

  • PDF

건물 계단 이용에 따른 심폐기능의 변화 (Variation of Cardiopulmonary Function by Use of Building Stairs)

  • 이승주
    • 대한물리치료과학회지
    • /
    • 제3권2호
    • /
    • pp.989-995
    • /
    • 1996
  • 본 연구는 건물 계단을 올라감에 따른 심폐기능의 변화를 알아보기 위해 안동전문대학 물리치료과에 재학 중인 1, 2, 3학년 학생 총 136명 중 50명을 무작위로 추출하여 1995년 9월 20일에서 10월 3일까지 14일간 조사된 연구의 분석결과는 다음과 같다. 1. 연구대상자의 일반적인 특성 중 신장은 평균 166.4cm, 체중은 57.7kg이었다. 2. 안정시 수축기혈압은 평균 121.3mmHg, 이완기 혈압은 78.5 mmHg였다. 3. 안정시 맥박수는 평균 71.8회, 호흡수는 20.4회, 체온은 $36.8^{\circ}C$였다. 각 층에서 심폐기능의 변화를 파악하기 위해 분산분석을 실시한 결과는 다음과 같다. 1. 측정 후 2, 3, 4충간의 수축기혈압은 각각 129.0 mmHg, 127.0 mmHg, 132.0 mmHg로 3층에서는 약간 낮았으나 점차 증가하였고 (P=0.1919), 이완기혈압도 80.1mmHg, 76.5mmHg, 82.0 mmHg로 3층에서 약간 낮은 후 점차 증가하였으나 통계적 차이는 없었다(P=0.4229). 2. 맥박수는 2, 3, 4층에서 각각 74.0회, 73.1 회, 74.0회로 충간의 뚜렷한 차이가 없었다(P = 0.8148). 3. 호흡수는 2, 3, 4층에서 21.4회, 23.1회, 24.6회로 층수가 높아짐에 따라 횟수가 증가하여 통계적으로 유의한 차이를 보였다(P = 0.0071). 4. 체온은 2, 3, 4층에서 36.8, 36.6, $36.5^{\circ}C$로 통계적으로 유의하게 낮아짐을 나타내었다(P=0.0040). 따라서 본 연구결과에 의하면 건물의 계단을 올라감에 따라 호흡수는 증가하였고, 체온은 낮아짐을 알 수 있었다. 그래서 중추신경계환자 및 노약자들은 이 점을 의식해야 될 것으로 사료되며, 본 연구는 정상인을 대상으로 측정을 실시하였지만 향후 환자를 대상으로 한 연구가 요구된다.

  • PDF