• Title/Summary/Keyword: Body scan

Search Result 574, Processing Time 0.024 seconds

Studies on Representative Body Sizes and 3D Body Scan Data of Korean Adolescents (한국 청소년의 대표 인체치수 및 3D 인체형상자료에 관한 연구)

  • Choi, Seung-il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.227-232
    • /
    • 2016
  • 3D body scan data are used widely in various fields to make products and living spaces for superior human body fitness. Based on the 3D measurements of human bodies for teens in Size Korea 2013, this research provides a way of finding the representative body sizes and 3D body scan data. First, a multi-dimensional vector space consisting of many measurement items was projected onto a 2D vector space with circumference and length components via factor analysis. The representative body sizes and 3D scan data close to these values were obtained via the Mahalanobis distance in 2D space. Considering the adolescent growth pattern shown on this 2D space, males were divided into 4 age groups and females were divided into 3 age groups. Using the eigenbodies corresponding to the column vectors of the component score coefficient matrix, the representative body sizes of 13 measurement items (male) and 14 measurement items (female) for each age group were calculated. The representative body sizes and 3D scan data are very useful for modeling representative 3D human figures.

Usefulness of Blood Pool Half Body in Three Phase Bone Scan in Patients with R/O Reflex Symphathetic Dystrophy Syndrome (반사성교감신경 이영양증후군 환자의 삼상 골 스캔 시 Half Body 혈액 풀 영상의 적용)

  • Lee, Moo-Seok;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.105-110
    • /
    • 2010
  • Purpose: Three phase bone scan was considered sensitive in Patients with Reflex Symphathetic Dystrophy Syndrome (RSDS). Generally, three phase bone scan in the RSDS patients shows increased uptake of one side extremity joint. But three phase bone scan has been performed with flow, blood pool and delayed scan. We performed blood pool half body scan in order to investigate its usefulness. Materials and Methods: From October 2007 to September 2009, three phase bone scan (flow, blood pool, half body blood pool, delayed) was performed after injection of 750 MBq of $^{99m}Tc$-DPD in diagnosed patients with RSDS (M:F=8:7, R:L=9:6). For quantitative analysis, we obtained the count ratios of bilateral hands by drawing a region of interest (ROI) in the three phase images and compared with the count ratios of shoulders in half body blood pool and delayed images. Results: In flow images, right/left ratios were $1.09{\pm}0.53$. In blood pool images, right/left ratios were $1.13{\pm}0.47$ (hand), $1.08{\pm}0.26$ (shoulder). In delayed images, right/left ratios were $1.24{\pm}0.75$ (hand), $1.11{\pm}0.31$ (shoulder). As a result, Log of right/left counts of the others and that of shoulder blood pool image were correlated well with statistical significance (Spearman's R, p<0.005 SPSS for windows ver.12.0). Conclusion: Half body blood pool scan may be helpful in the diagnosis of patients with RSDS. Moreover, Half body blood pool scan reduced false negative and false positive rates. In order to improve agreement on interpretation of RSDS, Blood pool half body scan should be established as common criteria.

  • PDF

Upper Body Measurement of Men using 3D Body Scanner -Compared to Anthropometry- (3차원 바디 스캐너를 이용한 남성 상반신 인체측정 -직접측정과의 비교-)

  • Paek, Kyung-Ja;Lee, Jeong-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.24-34
    • /
    • 2008
  • Three dimensional body scan technology is being targeted for utilization in the apparel industry. The purpose of this study was to test reliability of the body scan data targeting from 20 to 24 year old men by comparing 3DM, 3D body-scanning semi-auto measurement extraction method, Scanworx, 3D body-scanning auto measurement extraction method, and traditional anthropometric method. We found significant differences in 9 out of 25 items in upper body measurements using 3DM and 16 out of 25 items using Scanworx. In the range of difference value of scan measures, it showed 1 item in the absolute value of more than 40mm between two measuring methods, 3 items in 20 up to 40mm, and less than 20mm in other items. Overall, in height items, the numerical value of traditional measure was higher and in girth, width, depth items, 3D scan measure was higher. We found out that reliability of 3D measurements taken from whole body scans was different according to scanners, scanning softwares, programs, and subjects.

Evaluating the Usability of Medical Body Wrap in Whole Body Bone Scan (전신 뼈 검사에서 의료용 신체 고정구의 유용성 평가)

  • Dong-Oh Shim;Woo-Young Jung;Jae-Kwang Ryu;Cheol-Hong Park;Yoon-Jae Kim
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.49-56
    • /
    • 2024
  • Purpose: When performing nuclear medicine examinations, body wraps or plastic supports are used to support and immobilize the patient's upper extremities to prevent patient safety accidents. However, the existing plastic supports compromised patient and staff safety, including finger entrapment and falls. Moreover, the body wrap provided by manufacturers compromised image quality such as upper extremities cutoff during whole body bone scan. Therefore, a new design of body wrap was developed to improve the issue, and this study aims to evaluate the usability of this medical body wrap. Materials and Methods: To evaluate the usability of the newly designed medical body wrap, a quality assessment of whole body bone scan images and a user satisfaction survey were conducted. Adult patients (male:female=129:152, age: 60.3±12.4 years, BMI: 24.0±4.2) aged 16 years or older who underwent a whole body bone scan during two periods: June to July 2022 (before improvement, n=139) and June to July 2023 (after improvement, n=142) were randomly selected for image quality evaluation. Five radiotechnologists visually evaluated the posterior view of the whole body bone image, including the left and right elbow (2 points), arm (2 points), whether the hand is extended (2 points), whether the hand is included (2 points), and the number of visible fingers (10 points), with a total of 18 points, which were converted to 100 points and analyzed for difference before and after improvement using an independent sample t-test. The user satisfaction questionnaire was evaluated using a 5-point Likert scale among 16 radiotechnologists from three general hospitals who experienced the new body wrap. Results: The image quality assessment was 82.0±13.8 before the improvement and 89.3±10.1 after the improvement, an average of 7.3 points higher, with a statistically significant difference (t=5.02, p<0.01). The user satisfaction survey showed an overall satisfaction rating of 4.1±0.8 for ease of use, 3.8±0.7 for scan preparation time, 3.9±0.7 for patient safety, 3.8±1.2 for scan accuracy, and 4.2±0.7 for recommendation (87.5% questionnaire response rate). Conclusion: The developed body wrap showed higher image quality and user satisfaction compared to the old method. Considering these results, it is deemed that the new body wrap may be more useful than existing methods.

Displacement of scan body during screw tightening: A comparative in vitro study

  • Kim, JungHan;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.307-315
    • /
    • 2020
  • PURPOSE. The purpose of this study was to evaluate the occurrence of displacement while tightening the screw of scan bodies, which were compared according to the material type. MATERIALS AND METHODS. Three types of scan bodies whose base regions were made up of polyether ether ketone (PEEK) material [Straumann Group, Dentium Group, and Myfit (PEEK) Group] and another scan body whose base region was made up of titanium material [Myfit (Metal) Group] were used (15 per group). The reference model was fabricated by aligning the scan body library on the central axis of the implant, and moving this position by the resin model. The screws of the scan bodies were tightened to the implant fixture with torques of 5 Ncm, 10 Ncm, and a hand tightening torque. After the application of the torque, the scan bodies were scanned using a laboratory scanner. To evaluate the vertical, horizontal, and 3-dimensional (3D) displacements, a 3D inspection software program was used. To examine the difference among groups, one-way analysis of variance and Tukey's HSD post hoc test were used (α=.05). RESULTS. There were significant differences in 3D, vertical, and horizontal displacements among the different types of scan bodies (P<.001). There was a significantly lower displacement in the Straumann group than in the Myfit (PEEK) and Dentium groups (P<.05). CONCLUSION. The horizontal displacement in all groups was less than 10 ㎛. With the hand tightening torque, a high vertical displacement of over 100 ㎛ occurred in PEEK scan bodies (Myfit and Dentium). Therefore, it is recommended to apply a tightening torque of 5 Ncm instead of a hand tightening torque.

Classification of Side Somatotype of Upper Lateral Torso Analyzing 3D Body Scan Image of American Females (미국 여성의 3차원 바디 스캔 이미지 분석을 통한 상반신 측면체형 분류)

  • Na, Hyun-Shin
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.4 s.113
    • /
    • pp.9-17
    • /
    • 2007
  • Somatotype is human body shape and physique type which can be classified not only by the size, but also by the shape or posture of the body. Postural variations in the alignment of the back, shoulder, and neck can have an adverse effect on the fit of garments designed to hang from the shoulders. There have been some previous studies about the lateral upper torso by analyzing photographic measurements. In this study, 3D body scan images were used to classify the side somatotype of upper lateral method even though they are major data in the classification of upper torso. This study focused on following objective.; 1) To apply new and developing technology into the apparel industry analyzing 3D body scan images. 2) To classify upper laterla torso using the data through the new improver technology, 3D body scanner. 3) To propose basic materials for well fitted garments for each type of figure. The test subjects for this study were two hundreds nine female aged 19 years and up who were recruited in Cornell university body scan research team. Seventeen Variables(12 angles, 5 lengths) out of 3D body scan data were measured based on these landmarks and applied to analyze. The result of factor analysis indicated that 6 factors were extracted through factor analysis and orthogonal rotation by the method of Varimax and those factors comprise 62.5% of total variance. And the somatotype of upper body is classified into 3 types of figures according to cluster analysis; Bent forward posture, Straight posture, Swayback posture. Future study could be addressed about the somatotype of body by the age group based on the large database with wide variety of age.

Landmark Extraction for 3D Human Body Scan Data Using Markerless Matching (마커 없는 매칭을 활용한 3 차원 인체 스캔 데이터의 기준점 추출)

  • Yoon, Dong-Wook;Heo, Nam-Bin;Ko, Hyeong-Seok
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.163-167
    • /
    • 2009
  • 3D human body scan technique is known to be practically useful in industrial field as the technique becomes more precise and cheaper. Landmark extraction is essential for full utilization of the scan data. In this paper, we suggest an algorithm for automatic landmark extraction. For this purpose, we perform markerless matching to the target data using PCA analysis and quasi-Newton optimization. Landmarks are extracted from the topology of resulting body.

  • PDF

Usability verification of virtual clothing system for the production of a 3D avatar reproduced from 3D human body scan shape data - Focusing on the CLO 3D program - (3차원 인체스캔형상을 재현한 3D 아바타 제작을 위한 가상착의 시스템의 활용성 검증 -CLO 3D 프로그램을 중심으로-)

  • Hong, Eun-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.22 no.1
    • /
    • pp.1-13
    • /
    • 2020
  • The purpose of this study is to create a 3D avatar from 3D human body shape data using the CLO 3D virtual clothing program and to verify the feasibility of avatar production using the virtual clothing system for verifying size and shape. The research method was to select one virtual representative model that is the closest to the mean size of each body item for each age group. Using the 3D human body scan shape of a 40-69 years old male was applied to the CLO 3D virtual wearing system. Using the CLO 3D Avatar conversion menu, we verified the feasibility of creating a 3D avatar that reproduces the human body scan shape. In the dimension comparison between the 3D avatar and the fictitious representative model, the dimension difference was noticeable in height, circumference, and length. However, as a result, the converted 3D avatar showed less than a 5% difference in most human dimensions. In addition, since the body shape and posture were reproduced similarly, the utilization of the avatar was verified.

Body Shapes of Aged Women Applying 3D Body Scan Data (인체 형상 데이터를 이용한 실버 여성 3차원 체형 연구)

  • Kim, Soo-A;Choi, Hei-Sun
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.6
    • /
    • pp.1099-1111
    • /
    • 2009
  • The purpose of this study is to classify body shapes of aged women by using 3D body scan data. For the body shape analysis and classification, 3D body scan data of 270 aged women were used, and 16 main measurements consisting of a human body were used to conduct factor analysis, cluster analysis and discriminant analysis. The analysis were performed on all 'the method using the absolute value', 'the method using index of height and weight', and 'the method using index of height', and according to the classification results, the method which categorizes body shapes best in terms of their shapes was adopted. As the factor analysis result using the numerical value of height to categorize the body shapes of the aged women, factor 1 was the thickness and width for the height, factor 2 was the height of the upper part of the body for the height, factor 3 was the height of hips for the height, and factor 4 was the height of belly for the height. When the body shapes were categorized with the deducted factors as variables, they were divided into two types. Type 1 was a short and fat body shape($\blacksquare$ type) and 55.6% of the subjects were of this type. Type 2 was for the body shape whose vertical height, including weight, was long but all kinds of width and thickness were small, that is, tall and thin body shape($\blacksquare$ type), and 44.4% of the aged women were in this case.

  • PDF

A study on procedure for classifying male muscular lower body somatotype from general anthropometric database

  • Lee, Minji;Chun, Jongsuk
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.4
    • /
    • pp.585-595
    • /
    • 2013
  • The most researches developing pattern of compression style sportswear were targeted at the live model that has muscular body build. The purpose of this study was developing a method for classifying men's lower body types in terms of muscular body build. The 3D human body scan data and body measurements of 30s of Size Korea were analyzed. The subjects (n=203) were men between the ages of 30 and 39 years. Men's muscular body build was classified with two key dimensions, thigh girth and calf girth. The subjects were divided into four groups. From each group, average subjects (n=42) whose height and weight were close to the mean value ($mean{\pm}1/2$ S.D.) were selected. 42 subjects were divided up as four groups. Group I (n=7) was thigh and calf developed body type. Group II (n=9) was thigh developed body type. Group III (n=11) was calf developed body type. Group IV (n=15) was thigh and calf undeveloped body type. Four groups had distinct different at widths (n=4), depths (n=4), and girths (n=9) dimensions. The results showed that the muscular men in their 30s could be defined by thigh and calf girths. The thigh developed muscular men had thigh girth over 60cm and the calf developed muscular men had calf girth over 38cm. From each group one representative was selected by 3D body scan figure.