• Title/Summary/Keyword: Biological filters

Search Result 131, Processing Time 0.021 seconds

Characteristics of Bacterial Communities in Biological Filters of Full-Scale Drinking Water Treatment Plants

  • Choi, Yonkyu;Cha, Yeongseop;Kim, Bogsoon
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.1
    • /
    • pp.91-104
    • /
    • 2019
  • The taxonomic and functional characteristics of bacterial communities in the pre-chlorinated rapid filters and ozonated biological activated carbon (BAC) filters were compared using Illumina MiSeq sequencing of the 16S rRNA gene and community-level physiological profiling (CLPP) based on sole-carbon-source utilization patterns. Both the rapid filters and BAC filters were dominated by Rhizobiales within ${\alpha}-proteobacteria$, but other abundant orders and genera were significantly different in both types of filter. Firmicutes were abundant only in the intermediate chlorinated rapid filter, while Acidobacteria were abundant only in the BAC filters. Bacterial communities in the rapid filter showed high utilization of carbohydrates, while those in the BAC filters showed high utilization of polymers and carboxylic acids. These different characteristics of the bacterial communities could be related to the different substrates in the influents, filling materials, and residual disinfectants. Chlorination and ozonation inactivated the existing bacteria in the influent and formed different bacterial communities, which could be resistant to the oxidants and effectively utilize different substrates produced by the oxidant, including Phreatobacter in the rapid filters and Hyphomicrobium in the BAC filters. Bradyrhizobium and Leptothrix, which could utilize compounds adsorbed on the GAC, were abundant in the BAC filters. Ozonation increased taxonomic diversity but decreased functional diversity of the bacterial communities in the BAC filters. This study provides some new insights into the effects of oxidation processes and filling materials on the bacterial community structure in the biological filters of drinking water treatment plants.

The Effect of Vacuum Pressure in Membrane Filtration Systems for the Efficient Detection of Bacteria from Natural Mineral Water

  • LEE, KI-YONG;CHANG-JAE WOO;TAE-RYEON HEO
    • Journal of Microbiology and Biotechnology
    • /
    • v.8 no.2
    • /
    • pp.124-128
    • /
    • 1998
  • The procedures currently used for determining microbiological quality of natural mineral water recommend filtration through membrane filters. In this study, we evaluated the effect of vacuum pressure for the accurate detection of bacteria from water samples seeded with Escherichia coli. We observed that the number of E. coli detected increased with increasing vacuum pressure. In order to examine the retention rate of bacteria in the holes of the membranes under the different pressures, the membrane filters were removed after filtration, washed with sterile water by vortexing, and placed on m-Endo agar plates. With all the filters tested, the number of E. coli retained within the filters at negative 600 mmHg was approximately 10 to $20\%$ higher than that obtained with 100 mmHg. These results demonstrate that the vacuum pressure exerted during the filtration procedure may affect the fixation of bacteria into some portions of openings in the membrane filter.

  • PDF

Time Domain Analysis of Digital Filters for Noise Cancelling in ECG Signals (ECG신호의 잡음 제거를 위한 디지탈 필터의 시간 영역 해석)

  • Nam, Hyun-Do;Ahn, Dong-Jun;Lee, Cheol-Heui
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.137-145
    • /
    • 1993
  • Time domain analysis as well as frequency domain analysis of signal conditioning filters is very useful for practical applications. Time domain analysis of digital filters for noise cancelling in ECG signals is presented. Several band pass and band reject filters are designed for the analysis. Computer simulations are performed to compare the distortions of the Butterworth type filters and linear phase optimal FIR filters which are widely used for ECG signal processing. Band reject filters are applied to power line interference cancelling in ECG signals.

  • PDF

Design and Distortion Analysis of Digital Filters for ECG Waveforms Detection (EOG 신호의 파형 감지를 위한 디지털 필터의 설계 및 왜형 해석)

  • Nam, Hyun-Do;Ahn, Dong-Jun;Lee, Cheol-Heui
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.05
    • /
    • pp.70-73
    • /
    • 1993
  • Design as well as Distortion analysis of signal conditioning filters is very useful for practical applications. Distortion analysis of digital filters for wave forms detection in ECG signals is presented. Several band pass and band reject filters are designed for the analysis. Computer simulations are performed to compare the distortions of the Butterworth type filters and linear phase optimal FIR filters which are widely used for ECG signal processing.

  • PDF

Design of FPGA Adaptive Filter for ECG Signal Preprocessing (FPGA를 이용한 심전도 전처리용 적응필터 설계)

  • 한상돈;전대근;이경중;윤형로
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.285-291
    • /
    • 2001
  • In this paper, we designed two preprocessing adaptive filter - high pass filter and notch filter - using FPGA. For minimizing the calculation load of multi-channel and high-resolution ECG system, we utilize FPGA rather than digital signal processing chip. To implement the designed filters in FPGA, we utilize FPGA design tool(Altera corporation, MAX-PLUS II) and CSE database as test data. In order to evaluate the performance in terms of processing time, we compared the designed filters with the digital filters implemented by ADSP21061(Analog Devices). As a result, the filters implemented by FPGA showed better performance than the filters based on ADSP21061. As a consequence of examination, we conclude that FPGA is a useful solution in multi-channel and high-resolution signal processing.

  • PDF

Analysis and effectiveness of biological thin Layer (Schmutzdecke) on the sand surface in slow sand filtration processes (완속여과 공정에서 표층 생물막 생성 및 제어와 원인조류 규명)

  • Kim, Seong-Su;Park, No-Suk;Kim, Chung-Hwan;Park, Jong-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.3
    • /
    • pp.289-298
    • /
    • 2008
  • Because of their simplicity, efficiency, and economy, slow sand filters are appropriate means of water treatment for small water systems. Biological activity within the sand bed have the strongest influence on removal efficiency of pollutants by slow sand filtration. This report investigated the microorganisms(algae) of slow sand filtration pilot plant at Y water treatment plant. Data were collected at inflow and slow sand filtration from May to October, 2007. The results indicated that the light exposure was influenced on microorganism in slow sand filtration according to the formation of algal biofilm. The relative contribution of biomass and accumulated particulates to head loss development in slow sand filters requires further study.

Design of a pattern recognizing neural network using information-processing mechanism in optic nerve fields (시각정보 처리 메커니즘을 이용한 형태정보인식 신경회로망의 구성)

  • Kang, Ick-Tae;Kim, Wook-Hyun;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.33-42
    • /
    • 1995
  • A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filters representing global features is proposed in this network.

  • PDF

Survival of Microorganisms on Antimicrobial Filters and the Removal Efficiency of Bioaerosols in an Environmental Chamber

  • Kim, Sung Yeon;Kim, Misoon;Lee, Sunghee;Lee, JungEun;Ko, GwangPyo
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.9
    • /
    • pp.1288-1295
    • /
    • 2012
  • Exposure to bioaerosols causes various adverse health effects including infectious and respiratory diseases, and hypersensitivity. Controlling exposure to bioaerosols is important for disease control and prevention. In this study, we evaluated the efficacies of various functional filters coated with antimicrobial chemicals in deactivating representative microorganisms on filters or as bioaerosols. Tested functional filters were coated with different chemicals that included (i) Ginkgo and sumac, (ii) Ag-apatite and guanidine phosphate, (iii) $SiO_2$, ZnO, and $Al_2O_3$, and (iv) zeolite. To evaluate the filters, we used a model ventilation system (1) to evaluate the removal efficiency of bacteria (Escherichia coli and Legionella pneumophila), bacterial spores (Bacillus subtilis spore), and viruses (MS2 bacteriophage) on various functional filters, and (2) to characterize the removal efficiency of these bioaerosols. All experiments were performed at a constant temperature of $25^{\circ}C$ and humidity of 50%. Most bacteria (excluding B. subtilis) rapidly decreased on the functional filter. Therefore, we confirmed that functional filters have antimicrobial effects. Additionally, we evaluated the removal efficiency of various bioaerosols by these filters. We used a six-jet collision nebulizer to generate microbial aerosols and introduced it into the environmental chamber. We then measured the removal efficiency of functional filters with and without a medium-efficiency filter. Most bioaerosol concentrations did not significantly decrease by the functional filter only but decreased by a combination of functional and medium-efficiency filter. In conclusion, functional filters could facilitate biological removal of various bioaerosols, but physical removal of these by functional was minimal. Proper use of chemical-coated filter materials could reduce exposure to these agents.

Custom-Made ITE Type Hearing Protection Device Using a Small Acoustic Filter

  • Lee, Yun-Jung;Kim, Pil-Un;Jung, Young-Jin;Chang, Yong-Min;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.376-383
    • /
    • 2006
  • Noise induced hearing loss (NIHS), the well-known occupational disease, is caused by continuous excessive noise. The prevention of NIHS is very important, because it is unrecoverable. There are some kinds of hearing protection device (HPD), and those are effective in preventing NIHS. But workers in noisy environment often resist to wearing them. Because they are ready - made products, so workers feel uncomfortable to wear. Also, they didn't maintain the conversation frequency range, so workers are hard to communicate in wearing them. To prevent hearing loss effectively, it is important that workers keep wearing HPD. Therefore, a HPD is needed to be comfortable to wear and be effective not only in hearing protection but also in preserving communication ability. So we proposed a custom - made hearing protection device in which a small acoustic filter is inserted. We designed several kinds of small acoustic filters and carried out some acoustic experiments for measuring characteristics of filters. We confirmed that acoustic transmission characteristic can be adjusted from experimental results using designed small acoustic filters. And we researched for the actual efficiency of a new developed custom - made hearing protection device using a small size acoustic filter. Also, we found out that workers are more satisfied with the new development than a former protection device from a workers' response.

Biodegradation of UV Filters in Biological Activated Carbon (BAC) Process : Biodegradation Kinetic (BAC 공정에서의 자외선 차단제 생물분해 특성 : 생물분해 동력학)

  • Seo, Chang-Dong;Son, Hee-Jong;Jung, Jong-Moon;Choi, Jin-Taek;Ryu, Dong-Choon;Jang, Seong-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.739-746
    • /
    • 2014
  • In this study, The effects of empty bed contact time (EBCT) and water temperature on the biodegradation of 8 UV filters in biological activated carbon (BAC) process were investigated. Experiments were conducted at two water temperatures (7 and $18^{\circ}C$) and three EBCTs (5, 10 and 15 min). Increasing EBCT and water temperature increased the biodegradation efficiency of UV filters in BAC column. EHMC and BZC were the highest biodegradation efficiency, but BP and 4-MBC were the lowest. The kinetic analysis suggested a first-order reaction model for biodegradation of 8 UV filters at various water temperatures and EBCTs. The first-order biodegradation rate constants ($k_{bio}$) of 8 UV filters ranging from $0.2730{\sim}0.6365min^{-1}$ at $7^{\circ}C$ to $0.4824{\sim}0.8743min^{-1}$ at $18^{\circ}C$. By increasing the water temperature from $7^{\circ}C$ to $18^{\circ}C$, the biodegradation rate constants ($k_{bio}$) were increased 1.5~2.1 times.