• 제목/요약/키워드: Bio Sensors

검색결과 326건 처리시간 0.031초

Bio-Sensors for DNA and pH

  • Sawada, Kazuaki
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2004년도 International Symposium
    • /
    • pp.49-63
    • /
    • 2004
  • PDF

SQUID Systems for Magnetocardiographic Applications

  • Lee, Yong-Ho;Kim, Jin-Mok;Kwon, Hyuk-Chan;Yu, Kwon-Kyu;Kim, Ki-Woong;Park, Yong-Ki
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권2호
    • /
    • pp.1-6
    • /
    • 2007
  • As very sensitive magnetic field sensors, superconducting quantum interference devices (SQUIDs) are used to measure magnetic field signals from the human heart. By analyzing these cardiomagnetic signals, functional diagnoses of heart can be done. In order to measure weak biomagnetic signals, we need a multichannel SQUID array with sensor coverage large enough to cover the whole heart to enable the measurement in a single position setting. In this paper, we review the recent development of SQUID systems for measuring cardiomagnetic fields, with special emphasis on SQUID types.

브래그 격자 광도파로형 바이오 센서 (Polymeric Waveguide Bio Sensors with Bragg Gratings)

  • 이재현;김경조;오민철
    • 한국광학회지
    • /
    • 제17권1호
    • /
    • pp.54-59
    • /
    • 2006
  • 본 논문에서는 집적 광학 광도파로 소자 기술을 적용하여 생화학 물질의 성분을 정밀하게 측정 가능한 광소자로서 폴리머 광도파로와 브래그 격자를 이용하는 구조를 최초로 제안하였다. 유효굴절률법과 전송행렬법을 이용하여 최적의 감도를 가지는 브래그 격자 광도파로를 설계하였으며 코아와 하부 클래딩의 굴절률이 각각 1.540, 1.430인 폴리머를 이용하여 코아 두께가 $3{\mu}m$ 인 구조의 반전립 광도파로를 제작하였다. 코아 층까지 완성된 도파로 위에 레이저 빔 간섭계와 플라즈마 에칭을 이용하여 격자를 형성한 뒤 격자표면에 20 nm 두께의 Au층을 증착하고 칼릭사린(calixarene) 단분자층을 만들어 바이오센서를 제작하였다. 제작된 광센서를 이용하여 PBS(phosphate bufferedsaline) 용액에 함유된 $K^+$의 농도에 따라 브래그 반사픽이 단파장으로 이동하는 것을 관찰할 수 있었다.

u-EMS : 바이오 센서 네트워크 기반의 응급 구조 시스템 (u-EMS : An Emergency Medical Service based on Ubiquitous Sensor Network using Bio-Sensors)

  • 김홍규;문승진
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제13권7호
    • /
    • pp.433-441
    • /
    • 2007
  • 바이오센서는 생명공학 또는 의학 분야에서 사용되는 인간의 생체 신호를 감지할 수 있는 센서들로 의료기기에 주로 사용되는데, 최근 MEMS 기술의 발달로 작은 크기의 하드웨어에 센서 인터페이스, 프로세서, 무선통신, 배터리 등을 포함한 모듈을 센서노드(모트 : Mote)들로 구성된 센서기반 네트워크에서 바이오센서 네트워크로 응용분야를 확장하고 있다. 이에 본 논문에서는 바이오센서 기술과 센서네트워크 기술을 융합한 기술인 바이오 센서네트워크를 활용한 응급 구조 시스템의 설계 및 구현을 제안한다. 제안된 시스템에 사용된 바이오센서는 근전도(EKG), 혈압(Blood Pressure), 맥박(Heart Rate), 산소포화도(Pulse Oximeter), 혈당(Glucose)센서들로, 바이오센서에서 측정된 생체 신호를 센서네트워크 모트를 통해 데이타를 수집하고, 수집된 데이타를 이용하여 건강관리 측정 데이타로 활용하였으며 측정된 데이터는 무선단말기(PDA, 휴대폰), 전자액자 디스플레이장치 등에서 확인 가능하도록 구성하였다. 아울러, 제안한 u- 응급 구조 시스템의 유효성을 실험하기 위해서 사용자의 바이탈사인 정보와 주변 환경정보를 고려한 실험을 수행하였다.

A Unified Potentiostat for Electrochemical Glucose Sensors

  • Sohn, Ki-Sung;Oh, Seok-Jae;Kim, Eui-Jin;Gim, Jeong-Min;Kim, Nam-Soo;Kim, Yeong-Seuk;Kim, Jong-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권5호
    • /
    • pp.273-277
    • /
    • 2013
  • A unified potentiostat circuit for both $O_2$- and $H_2O_2$- based electrochemical glucose sensors was proposed and its function was verified by circuit simulations and measurement results of a fabricated chip. This circuit consisted of an operational amplifier, a comparator and current mirrors. The proposed circuit was fabricated with a $0.13{\mu}m$ thick oxide CMOS process and an active area of $360{\mu}m{\times}100{\mu}m$. The measurements revealed an input operation range from 0.5 V to 1.6 V in the $H_2O_2$- based bio-sensor and from 1.7 V to 2.6 V in the $O_2$- based bio-sensor with a supply voltage of 3.3 V. The evaluation results showed that the proposed potentiostat circuit is suitable for measuring the electrochemical cell currents of both $O_2$- and $H_2O_2$- based glucose sensors.

Highly Sensitive Flexible Organic Field-Effect Transistor Pressure Sensors Using Microstructured Ferroelectric Gate Dielectrics

  • 김도일;이내응
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.277.2-277.2
    • /
    • 2014
  • For next-generation electronic applications, human-machine interface devices have recently been demonstrated such as the wearable computer as well as the electronic skin (e-skin). For integration of those systems, it is essential to develop many kinds of components including displays, energy generators and sensors. In particular, flexible sensing devices to detect some stimuli like strain, pressure, light, temperature, gase and humidity have been investigated for last few decades. Among many condidates, a pressure sensing device based on organic field-effect transistors (OFETs) is one of interesting structure in flexible touch displays, bio-monitoring and e-skin because of their flexibility. In this study, we have investigated a flexible e-skin based on highly sensitive, pressure-responsive OFETs using microstructured ferroelectric gate dielectrics, which simulates both rapidly adapting (RA) and slowly adatping (SA) mechanoreceptors in human skin. In SA-type static pressure, furthermore, we also demonstrate that the FET array can detect thermal stimuli for thermoreception through decoupling of the input signals from simultaneously applied pressure. The microstructured highly crystalline poly(vinylidene fluoride-trifluoroethylene) possessing piezoelectric-pyroelectric properties in OFETs allowed monitoring RA- and SA-mode responses in dyanamic and static pressurizing conditions, which enables to apply the e-skin to bio-monitoring of human and robotics.

  • PDF

FFT analysis of load data during field operations using a 75-kW agricultural tractor

  • Ryu, Myong-Jin;Chung, Sun-Ok;Kim, Yong-Joo;Lee, Dae-Hyun;Choi, Chang-Hyun;Lee, Kyeong-Hwan
    • 농업과학연구
    • /
    • 제40권1호
    • /
    • pp.53-59
    • /
    • 2013
  • Analysis of load data during field operations is highly important for optimum design of power drive lines for agricultural tractor. Objective of the paper was to analyze field load data using FFT to determine frequency and the energy levels of meaningful cyclic patterns. Rotary tillage, plowing, baling, and wrapping operations were selected as major field operations of agricultural tractor. An agricultural tractor with power measurement system was used. The tractor was equipped with strain-gauge sensors to measure torque of four driving axles and a PTO axle, speed sensors to measure rotational speed of the driving axles and an engine shaft, pressure sensors to measure pressure of hydraulic pumps, an I/O interface to acquire the sensor signals, and an embedded system to calculate power requirement. In rotary tillage, calculated frequency was decreased as travel speed increased. In baler operation, calculated frequency was increased as PTO speed was increased. The calculated peak frequency levels and expected levels were similar. Results of the study would provide information on power utilization patterns and on better design of power drive lines.

One-dimensional Nanomaterials for Field Effect Transistor (FET) Type Biosensor Applications

  • Lee, Min-Gun;Lucero, Antonio;Kim, Ji-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제13권4호
    • /
    • pp.165-170
    • /
    • 2012
  • One-dimensional, nanomaterial field effect transistors (FET) are promising sensors for bio-molecule detection applications. In this paper, we review fabrication and characteristics of 1-D nanomaterial FET type biosensors. Materials such as single wall carbon nanotubes, Si nanowires, metal oxide nanowires and nanotubes, and conducting polymer nanowires have been widely investigated for biosensors, because of their high sensitivity to bio-substances, with some capable of detecting a single biomolecule. In particular, we focus on three important aspects of biosensors: alignment of nanomaterials for biosensors, surface modification of the nanostructures, and electrical detection mechanism of the 1-D nanomaterial sensors.

Au 전극의 DDT 보호막 처리 및 그 전기적 효과와 응용 (Electrical Property and Application of Au Electrodes Passivated with DDT Molecules)

  • 최민수;이동진;김태근;황성우
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.127-129
    • /
    • 2010
  • We report the passivation characteristics of dodecanethiol (DDT) molecules on gold electrodes of field effect transistor bio-sensors. The leakage current between the electrolyte and the electrode can be as small as 3pA when 7 mM of DDT passivation is performed. The DDT layer is also shown to resist the attack of acid up to 120 mins.

머리 움직임과 눈 깜박임을 이용한 컴퓨터 마우스 개발 (Development of a computer mouse by tracking head movements and eyeblink)

  • 박민제;강신욱;김수찬
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1107-1108
    • /
    • 2008
  • The purpose of this study is to develope a computer mouse using the head movements and eye blink in order to help the disability persons who can't move the hands or foot because of car accident or cerebral apoplexy. The mouse is composed of two gyro-sensors and photo sensor. The gryo-sensors detect the head horizontal and vertical angular velocities, respectively. The photo sensor detect the eye blink to perform click, double click, and to reset the head position. In the results, we could control the mouse points in real time using the proposed system.

  • PDF