• Title/Summary/Keyword: Bed Pressure

Search Result 540, Processing Time 0.027 seconds

A Study of Methane Oxidation over Transition Metal (TM)/CeO2 (TM=Ni, Co, Cu, Fe) (전이금속이 담지된 세리아의 메탄 산화 반응에 대한 연구)

  • Ahn, Ki-Yong;Chung, Yong-Chae;Lee, Jong-Ho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.346-352
    • /
    • 2012
  • The properties of methane oxidation were studied in this research over transition metal containing $CeO_2$ (TM/$CeO_2$, TM=Ni, Co, Cu, Fe) with TM content of 5 wt. % at atmospheric pressure. The characteristics of catalysts were investigated by various characterization techniques, including XRD, GC, SEM and EPMA analyses. The catalytic tests were carried out in a fixed Rmix ratio of 1.5 ($CH_4/O_2$) in a fixed-bed reactor operating isothermally at atmospheric pressure. Only the Ni/$CeO_2$ catalysts showed syngas production above $400^{\circ}C$ via typical partial oxidation reaction whereas other catalysts induced complete oxidation resulting in the production of $CO_2$ and $H_2O$ in whole reaction temperature range. From the quantitative analysis on carbon deposition after catalytic tests, Cu/$CeO_2$ was found to show the highest resistance on carbon deposition. Therefore Cu can be proposed as an efficient catalyst element which can be combined with a conventional Ni-based SOFC anode to enhance the carbon tolerance.

Design Study on a Variable Intake and a Variable Nozzle for Hypersonic Engines

  • Taguchi, Hideyuki;Futamura, Hisao;Shimodaira, Kazuo;Morimoto, Tetsuya;Kojima, Takayuki;Okai, Keiichi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.713-721
    • /
    • 2004
  • Variable air intake and variable exhaust nozzle of hypersonic engines are designed and tested in this study. Dimensions for variable geometry air intake, ram combustor and variable geometry exhaust nozzle are defined based on the requirements of a pre-cooled turbojet engine. Hypersonic Ramjet Engine is designed as a scaled test bed for each component. Actuation forces of moving parts for variable intake and variable nozzle are reduced by balancing the other force in the opposite direction. A demonstrator engine which includes variable intake and variable nozzle is designed and the components are fabricated. Composite material with silicone carbide is applied for high temperature parts under oxidation environment such as leading edge of the variable intake and combustor liner. Internal cooling structure is adopted for both moving and static parts of the variable nozzle. Pressure recovery and mass capture ratio of the variable intake at Mach 5 is obtained by a hypersonic wind tunnel test. Flow characteristics of the variable nozzle are obtained by a low temperature flow test. Wall temperature and heat flux of the nozzle at Mach 3 is obtained by a firing test. As results, the intake and the nozzle are proved to be used at designed pressure and temperature environment.

  • PDF

Investigation of Optimum Condition of Heat Treatment and Flow to Improve H2S Adsorption Capacity for Practical use of an Activated Carbon Tower (활성탄 흡착탑의 실용화를 위한 최적 유동특성 선정 및 열처리 조건에 따른 황화수소 포집능 향상 연구)

  • Jang, Younghee;Kim, Bong-Hwan;Kim, Sung Su
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.91-96
    • /
    • 2021
  • This study was conducted to improve the operating conditions of an adsorption tower filled with potassium impregnated activated carbon for high hydrogen sulfide capture capacity. Heat treatment modified the surface properties of activated carbon, and ultimately determined its adsorption capacity. The activated carbon doped with potassium showed 57 times more adsorption at room temperature than that of using the raw adsorbent. It is believed that uniform pore formation and strong bonding of the potassium on the surface of carbon contributed to the chemical and physical absorption of hydrogen sulfide. The SEM analysis on the surface structure of various commercial carbons showed that the modification of surface properties through the heat treatment generated the destruction of pore structures resulted in the decrease of the absorption performance. The pressure drop across the activated carbon bed was closely related with the grain size and shape. The optimum size of irregularly shaped activated carbon granules was 2~4 mesh indicating economical feasibility.

A Study on CFD of Turbo fan and Fabrication of Turbo Fan with Honeycombs by PBF (터보 팬의 유동해석 및 허니콤 구조가 적용된 터보 팬의 PBF 3D 프린팅 제작에 관한 연구)

  • Jin, Chul-Kyu;Lee, Haesoo;Lee, Un-Gil;Woo, Jae-Hyeog
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.899-908
    • /
    • 2022
  • In this study, a study was conducted to localize a large aluminum turbo fan used for tank powerpack. The turbo fan was scanned with a 3D scanner and then 3D modeling was performed. Computational fluid dynamics (CFD) were performed from the performance conditions of the fan, and structural analysis was performed using the pressure data obtained from CFD. The fan was reduced to 1/5 size by applying the geometric similarity. A 1/5 size fan has a honeycomb structure inserted into the front shroud and back shroud to reduce the weight by 5.3%. A 1/5 size fan was printed using a PBF 3D printer, and a 1/5 size fan with honeycombs was also printed. The pressure drop of 8.67 kPa and the required power of 138.19 kW, which satisfies the performance conditions of the fan, were confirmed from the results of CFD. The values of the maximum deformation amount of 0.000788 mm and the maximum effective stress of 0.241 MPa were confirmed from the structural analysis results. The fan printed by the PBF 3D printer had the same shape as the modeling, and the shape was perfect. There are no defects anywhere in appearance. However, the condition of the outer surface of the fan's back shroud is rough compared to other locations. The fan in which the honeycomb was inserted was also perfectly output, and the shape of the honeycomb was the same as the modeling.

Formation of Al2O2 supported Ni2P based 3D catalyst for atmospheric deoxygenation of rubberwood sawdust

  • Pranshu Shrivastava
    • Advances in Energy Research
    • /
    • v.8 no.4
    • /
    • pp.223-231
    • /
    • 2022
  • An ex-situ gravitational fixed bed pyrolysis reactor was used over Al2O3 supported Ni2P based catalyst with various Ni/P molar ratios (0.5-2.0) and constant nickel loading of 5.37 mmol/g Al2O3 to determine the hydrodeoxygenation of rubberwood sawdust (RWS) at atmospheric pressure. The 3D catalysts formed were characterized structurally as well as acidic properties were determined by hydrogen-temperature programmed reduction (TPR). The Ni2P phase formed completely on Al2O3 for 1.5 Ni/P ratio, although lesser crystallite sizes of Ni2P were seen at Ni/P ratios less than 1.5. Additionally, it was shown that when nickel loading level increased, acidity increased and specific surface area dropped, probably because nickel phosphate is not easily converted to Ni2P. When Ni/P ratio was 1.5, Ni2P phase fully formed on Al2O3. The catalytic activity was explained in terms of impacts of reaction temperature and Ni/P molar ratio. At relatively high temperature of 450℃, the high-value deoxygenated produce was predominantly composed of n-alkanes. Based on the findings, it was suggested that hydrogenolysis, hydrodeoxygenation, dehydration, decarbonylation, and hydrogenation are all part of mechanism underlying hydrotreatment of RWS. In conclusion, the synthesized Ni2P/ Al2O3 catalyst was capable of deoxygenating RWS with ease at atmospheric pressure, primarily resulting in long chained (C9-C24) hydrocarbons and acetic acid.

Experiment and Simulation of 2-bed PSA for Hydrogen Separation from H2/CH4 Gas Mixture (수소/메탄 혼합 기체로부터 수소 분리를 위한 두 탑 PSA 실험과 전산 모사)

  • Nam, Gi-Moon;Jeong, Byung-Man;Kang, Seok-Hyun;Lee, Chang-Ha;Lee, Byung-Kwon;Choi, Dae-Ki
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.249-258
    • /
    • 2005
  • A two-column six-step pressure swing adsorption(PSA) process was to study separation of hydrogen from hydrogen and methane($60_{vol}%/40_{vol}%$) binary system onto activated carbon adsorbent. The effects of the feed gas pressure, the feed flowrate and the P/F(purge to feed) ratio on the process performance were evaluated. The cyclic steady-states of PSA process were reached to after 15 cycles. $H_2$ purity increases according as the P/F ratio and pressure increase and the feed flow rate decreases; however, $H_2$ recovery shows an opposite phenomena to the purity. PSA process simulation studied to find optimum operation condition. In the results, 22 LPM feed flowrate, 11 atm adsorption pressure and 0.10 P/F ratio might be optimal values to obtain more than 75% recovery and 99% purity hydrogen. In this study was non-isothermal and non-adiabatic model considering linear driving force(LDF) model and Langmuir-Freundlich adsorption isotherm considered to compare between prediction and experimental data.

Experimental Study on the Adsorption Characteristics of Methane Gas Considering Coalbed Depth in Coalbed Methane Reservoirs (석탄층 메탄가스 저류층에서 탄층 심도를 고려한 메탄가스의 흡착 특성에 관한 실험 연구)

  • Chayoung Song;Dongjin Lee;Jeonghwan Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.39-48
    • /
    • 2023
  • This study presents the experimental results to measure the adsorption amount of methane gas by coal according to the conditions of a coalbed methane (CBM) reservoir. Adsorbed gas to coal seam particles was measured under reservoir conditions (normal pressure ~ 1,200 psi pressure range, temperature range15 ~ 45℃) using coal samples obtained from random mines in Kalimantan Island, North Indonesia. The obtained amount of absolute adsorbed gas was applied to triangular with linear interpolation to calculate the maximum amount of adsorbed gas according to temperature and pressure change, at which no experiment was performed. As a result, it was revealed that the amount of adsorbed gas to coal particles increased as the pressure increased and temperature decreased, but the increase of the amount of adsorbed gas decreased at more than an appropriate depth(1,000 ft). In the cleat permeability and cleat porosity for each depth of the coal bed considering the effective stress, the cleat permeability was 28.86 ~ 46.81 md, and the cleat porosity was 0.83 ~ 0.98%. This means that the gas productivity varies significantly with the depth because the reduction of the permeability according to the depth in the coal seam is significant. Therefore, a coalbed depth should be considered essential when designing the spacing of production wells in a coalbed methane reservoir in further study.

Removal of a High Load of Ammonia by a Marine Bacterium, Vibrio alginolyticus in Biofilter

  • Kim, Nam-Jin;Shoda, Makoto
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.5
    • /
    • pp.316-322
    • /
    • 2002
  • A newly isolated heterotrophic marine bacterium, Vibrio alginolyticus, was used to remove a high load of ammonia gas under non-sterile condition. The cells were inoculated onto an inorganic packing material in a fixed-bed reactor (biofilter), and a high load of ammonia, in the range of ammonia gas concentration of 170 ppm to 880 ppm, was introduced continuously. Sucrose solution and 3% NaCl was supplied intermittently to supplement the carbon source and water to the biofilter. The average percentage of gas removed exceeded 85% for 107-day operation. The maximum removal capacity and the complete removal capacity were$19\;g-N\;kg^{-1}$ dry packing material $day^{-1}$ and $16\;g-N\;kg^{-1}$ dry packing material $day^{-1}$, respectively, which were about three times greater than those obtained in nitrifying sludge inoculated onto the same packing material. On day 82, the enhanced pressure drop was restored to the normal one by NaOH treatment, and efficient removal characteristics were later observed. During this operation, the non-sterile condition had no significantly adverse effect on the removability of ammonia by V. alginolyticus.

A Survey on Prehospital Emergency Medical Service for the Improvement of Acute Coronary Syndrome Assessments - Focus on the Jecheon.Danyans Area - (급성관상동맥증후군 환자의 병원 전 119구급의료서비스 실태 및 개선방안 -충북 제천.단양을 중심으로-)

  • Roh, Sang-Gyun
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.293-299
    • /
    • 2008
  • From January, 2004 to July, 2007, 97 patients were diagnosed with Acute coronary syndrome(ACS) in Emergency Medical Center in Jecheon City in Korea. Among 97 patients, the prehospital assessment rates were as follows ; blood pressure check(27.80%, pulse rate check(33.0%), respiration check(23.7%). In hospital emergency care, oxygen supply was 52.6%, absolute bed rest was 12.4%, electrocardiogram(EKG) check was 4.1%, and nitroglycerin and intravenous fluid therapy was 0%. Therefore, ACS patients have not received sufficient prehospital cares till now. In order to improve the proficiency of the first aid emergency medical technicians(EMTs), it is necessary to provide the continuing On-the-job training(OJT) programs for prehospital emergency care.

Study on desulfurization performance of Zn-based solid sorbents at high temperature and pressure in the 0.3 bbl/d CTL(Coal-to-Liquid) process integrated with coal gasifier, F-T process and hot gas desulfurization process (석탄가스화기, F-T 공정, 건식탈황공정이 통합된 0.3 배럴/일 규모 석탄액화(CTL) 공정에서 고온, 고압 연속운전에서 아연계 탈황제의 탈황 성능 파악)

  • Park, Young Cheol;Jo, Sung-Ho;Jin, Gyoung Tae;Lee, Seung-Yong;Yi, Chang-Keun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.107.2-107.2
    • /
    • 2010
  • 고온건식탈황기술은 고온고압에서 석탄가스에 함유된 황화합물을 제거하는 기술로 석탄가스화에 의해 생성된 고온의 석탄가스의 열손실을 최소화하여 열효율이 높은 기술이다. 본 연구에서는 석탄으로부터 합성원유를 생산하는 0.3 배럴/일 규모 석탄액화(CTL)공정의 연계운전을 통하여 건식탈황공정의 성능을 평가하였다. 0.3 배럴/일 규모 석탄액화공정은 석탄가스화기, 건식탈황공정, 액화공정으로 구성되어 있으며 30 atm의 고압에서 운전된다. 건식탈황공정은 석탄가스화기와 액화공정 사이에 위치하여 석탄가스화로부터 생성된 석탄가스에 함유된 황화합물을 아연계 건식탈황제에 의해 제거한 후 액화반응기로 공급하여 황화합물에 의한 촉매의 피독을 막아주는 역할을 수행한다. 본 연구에서는 기존에 개발된 두 개의 기포유동층 반응기로 구성된 탈황장치를 30 atm에서 운전이 가능하도록 수정/보완하여 실제 운전압력인 30 atm의 고압에서 연속운전을 수행하였다. 실험 결과 탈황효율은 99% 이상이며 탈황반응기 출구 황화합물의 농도는 1 ppmv 이하로 유지하였다.

  • PDF