• 제목/요약/키워드: Averaging method

검색결과 555건 처리시간 0.032초

Errors in Estimated Temporal Tracer Trends Due to Changes in the Historical Observation Network: A Case Study of Oxygen Trends in the Southern Ocean

  • Min, Dong-Ha;Keller, Klaus
    • Ocean and Polar Research
    • /
    • 제27권2호
    • /
    • pp.189-195
    • /
    • 2005
  • Several models predict large and potentially abrupt ocean circulation changes due to anthropogenic greenhouse-gas emissions. These circulation changes drive-in the models-considerable oceanic oxygen trend. A sound estimate of the observed oxygen trends can hence be a powerful tool to constrain predictions of future changes in oceanic deepwater formation, heat and carbon dioxide uptake. Estimating decadal scale oxygen trends is, however, a nontrivial task and previous studies have come to contradicting conclusions. One key potential problem is that changes in the historical observation network might introduce considerable errors. Here we estimate the likely magnitude of these errors for a subset of the available observations in the Southern Ocean. We test three common data analysis methods south of Australia and focus on the decadal-scale trends between the 1970's and the 1990's. Specifically, we estimate errors due to sparsely sampled observations using a known signal (the time invariant, temporally averaged, World Ocean Atlas 2001) as a negative control. The crossover analysis and the objective analysis methods are for less prone to spatial sampling location biases than the area averaging method. Subject to numerous caveats, we find that errors due to sparse sampling for the area averaging method are on the order of several micro-moles $kg^{-1}$. for the crossover and the objective analysis method, these errors are much smaller. For the analyzed example, the biases due to changes in the spatial design of the historical observation network are relatively small compared to the tends predicted by many model simulations. This raises the possibility to use historic oxygen trends to constrain model simulations, even in sparsely sampled ocean basins.

서울 지역에 내린 우수 pH 특성 (PH Characteristics of Precipitation in Seoul Area)

  • 이민희;에이지 히라이;모토이치 미야자키;테츠리 차지;전호
    • 환경위생공학
    • /
    • 제9권2호
    • /
    • pp.1-7
    • /
    • 1994
  • Rainwater was collected in Seoul area from January 1991 to December 1993 (over 3years) and by the analysis of the chemical components contained in rainwater, investigated the components that effect on rainwater pH Through the above studies the following conclusions were obtained. 1) Method for Averaging pH Volume weighted method is considered to be acceptable providing that precipitation is measured at the same time when the samples are taken, without precipitation data a simple averaging method should be the next choice. 2) Annual average rainwater pH was 4.98 in 1991, 4.80 in 1992, 4.67 in 1993, measurement range was 3.6-8.1. 3) In the relationship between rainwater pH and rainfall amounts rainwater pH for light rain(<15mm rainfall) was existent in the wide range(pH 4-7), but for heavy rain was corresponded to the annual average values. 4) Annual frequency of pH was Birrndat the frequency($\gamma $) between the density of the [$H^{+}$] and pH in the rainwater(over 3years ), $NO_{3}^{-}$ was excellent and the obtained results was 0.62 in 1992. Also In the correlation coefficient($\gamma $) according to the pH range $SO_{4}^{2-}, NO_{3}^{-}$, were 0.85 ,0.68 at 3.6 $Cl^-$ was 0.99(1993). At 4.1$NO_{3}^{-}(\gamma=0.48)$ in 1992, SO_4^{2-}($\gamma$=0.54), $NO_{3}^{-}(\gamma$=0.72), $Cl^- (\gamma$=0.49) in 1993. 6) pH values gradually increased with increase in $Ca^{2+}/SO_{4}^{2-}$.

  • PDF

Design and Realization of a Digital PV Simulator with a Push-Pull Forward Circuit

  • Zhang, Jike;Wang, Shengtie;Wang, Zhihe;Tian, Lixin
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.444-457
    • /
    • 2014
  • This paper presents the design and realization of a digital PV simulator with a Push-Pull Forward (PPF) circuit based on the principle of modular hardware and configurable software. A PPF circuit is chosen as the main circuit to restrain the magnetic biasing of the core for a DC-DC converter and to reduce the spike of the turn-off voltage across every switch. Control and I/O interface based on a personal computer (PC) and multifunction data acquisition card, can conveniently achieve the data acquisition and configuration of the control algorithm and interface due to the abundant software resources of computers. In addition, the control program developed in Matlab/Simulink can conveniently construct and adjust both the models and parameters. It can also run in real-time under the external mode of Simulink by loading the modules of the Real-Time Windows Target. The mathematic models of the Push-Pull Forward circuit and the digital PV simulator are established in this paper by the state-space averaging method. The pole-zero cancellation technique is employed and then its controller parameters are systematically designed based on the performance analysis of the root loci of the closed current loop with $k_i$ and $R_L$ as variables. A fuzzy PI controller based on the Takagi-Sugeno fuzzy model is applied to regulate the controller parameters self-adaptively according to the change of $R_L$ and the operating point of the PV simulator to match the controller parameters with $R_L$. The stationary and dynamic performances of the PV simulator are tested by experiments, and the experimental results show that the PV simulator has the merits of a wide effective working range, high steady-state accuracy and good dynamic performances.

A COST-EFFECTIVE MODIFICATION OF THE TRINOMIAL METHOD FOR OPTION PRICING

  • Moon, Kyoung-Sook;Kim, Hong-Joong
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제15권1호
    • /
    • pp.1-17
    • /
    • 2011
  • A new method for option pricing based on the trinomial tree method is introduced. The new method calculates the local average of option prices around a node at each time, instead of computing prices at each node of the trinomial tree. Local averaging has a smoothing effect to reduce oscillations of the tree method and to speed up the convergence. The option price and the hedging parameters are then obtained by the compact scheme and the Richardson extrapolation. Computational results for the valuation of European and American vanilla and barrier options show superiority of the proposed scheme to several existing tree methods.

2:1 내부공진을 갖는 케이블의 비선형 진동의 분기해석 (Bifurcation Analysis of Nonlinear Oscillations of Suspended Cables with 2-to-1 Internal Resonance)

  • 장서일
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1144-1149
    • /
    • 1998
  • A two degree-of-freedom model of suspended cables is studied for forced resonant response. The method of averaging is used to obtain first-order approximations to the response of the system. A bifurcation analysis of the averaged system is performed in the case of 2-to-1 internal resonance. Nonlinear coupled-mode motions are found to bifurcate from single-mode responses and further bifurcate to limit cycle motions via Hopf bifurcations. The limit cycle solutions undergo period doubling bifurcations to chaos.

  • PDF

강압형 스위치드-커패시터 DC-DC 컨버터의 동특성해석 및 제어회로 설계 (Dynamic Analysis and Control Design of a Step-Down Switched-Capapcitor Dc-Dc Converter)

  • 최병조
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.485-488
    • /
    • 2000
  • In this paper dynamic analyses and control design of a step-down switched-capacitor dc-dc converter are presented. Open-loop dynamics of the converter are analyzed using the stage-space averaging technique. A systmatic control design method that offers excellent closed-loop performance for the converter is proposed, The analysis results and dynamic performance of the converter are verified using 18 W experimental converter that delivers a 5V/3.5V output from a 11-16V input source.

  • PDF

單一 排出源大氣汚染 短期모델에 관한 硏究 -Tracer Gas에 의한 擴散實驗- (On the Short Term Air Pollution Dispersion Model for the Single Souce -Diffusion Experiment With Tracer Gas-)

  • 李鍾範;姜寅求
    • 한국대기환경학회지
    • /
    • 제5권2호
    • /
    • pp.84-96
    • /
    • 1989
  • To evaluate the short term air pollution dispersion model, the diffusion experiment was conducted on the flat terrain near Chuncheon. Sulfur hexafluoride $(SF_6)$ gas was used to determine the horizontal spread of plume $(\sigmay)$ for calculated by CRSTER model. Results show that CRSTER model underestimates $\sigma$y because averaging time adjustment is not applied to calculate the $\sigma$y. The scheme that can estimate the atmospheric stability more accurate than Turner method, was presented.

  • PDF

Efficient Rolling Shutter Distortion Removal using Hierarchical Block-based Motion Estimation

  • Lee, Donggeun;Choi, Kang-Sun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권4호
    • /
    • pp.205-211
    • /
    • 2014
  • This paper reports an efficient algorithm for accurate rolling shutter distortion removal. A hierarchical global motion estimation approach for a group of blocks reduces the level of computation by three orders of magnitude. In addition, the motion of each scanline is determined accurately by averaging two candidates obtained through cubic spline interpolation. The experimental results show that the proposed method produces accurate motion information with significant computation reduction and corrects the rolling shutter distortion effectively.

스위칭 레귤레이터의 최적 LQ 제어 (OPTIMAL LQ CONTROL OF BUCK SWITCHING REGULATOR)

  • 유경상;권오규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.401-404
    • /
    • 1989
  • In this paper an optimal LQ controller is designed for the output characteristic improvement of buck-type switching regulators. State-space averaging method is adopted for modelling of switching regulators. The LQ controller is derived via an unified operator form for the application to both continuous-time and discrete-time control systems. Some design parameters of the LQ controller are chosen through a computer simulation and the LQ controller is implemented by analog circuits.

  • PDF

DC - DC 콘버어터의 다출력화에 따른 정상특성 및 안정성 해석 (Steady-State and Stability Analysis of Multioutput DC-DC Converter)

  • 김능수;이윤종;김희준
    • 대한전기학회논문지
    • /
    • 제37권8호
    • /
    • pp.534-539
    • /
    • 1988
  • The dynamic chatacteristics and stability including steady state characteristic of the currentfed DC-to-DC converter with multiouput, which has a considerable advantage about the multioutut circuit,are analyzed in this paper. It is performed by using the steady state averaging method. As result, we know that the error, which is caused by secondary winding resistance of the transformer, exists between the two outputs in the steady state characteristics. Furthemore, it is verified that the current-fed DC-to-DC converter has also excellent stability in the multioutput application.

  • PDF