• 제목/요약/키워드: Average radiation

검색결과 1,467건 처리시간 0.031초

이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구 (Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator)

  • 구본열;김가중
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.

Space Radiation Measurement on the Polar Route onboard the Korean Commercial Flights

  • Hwang, Jung-A;Lee, Jae-Jin;Cho, Kyung-Suk;Choi, Ho-Sung;Rho, Su-Ryun;Cho, Il-Hyun
    • Journal of Astronomy and Space Sciences
    • /
    • 제27권1호
    • /
    • pp.43-54
    • /
    • 2010
  • This study was performed by the policy research project of Ministry of Land, Transport and Maritime Affairs, which title is "Developing safety standards and management of space radiation on the polar route". In this research, total six experiments were performed using Korean commercial flights (B747). Three of those are on the polar route and the other three are on the north pacific route. Space radiation exposure measured on the polar route is the average 84.7 uSv. The simulation result using CARI-6M program gives 84.9 uSv, which is very similar to measured value. For the departure flight using the north pacific route, the measured space radiation is the average 74.4 uSv. It seems that is not so different to use the polar route or not for the return flight because the higher latitude effect causing the increase of space radiation is compensated by the shortened flight time effect causing decreasing space radiation exposure.

국내 태양광시스템 설치를 위한 수평면 전일사량과 일조시간 정밀조사 (A Detail Survey of Horizontal Global Radiation and Hours of Bright Sunshine for the Installation of Solar Photovoltaic System in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.48-56
    • /
    • 2011
  • Since the horizontal global radiation and hours of bright sunshine are a main factor for designing photovoltaic system, it is necessary to evaluate its characteristics all over the country. The work presented here are the investigation of horizontal global radiation and hours of bright sunshine in Korea. The data utilized in the investigation consist of horizontal global radiation and hours of bright sunshine collected for 28years(1982.12~2009.12) at measuring stations across the country. The analysis shows that the annual-average daily horizontal global radiation is3.61kWh/m2 and the annual-average daily hours of bright sunshineis 5.1 Hrs in Korea. We also constructed the contour map of hours of horizontal global radiation and hours of bright sunshine in Korea by interpolating actually measured data across the country.

인공위성을 이용한 국내 일사량 분포 예측 (Estimation of Solar Radiation Distribution in Korea Using a Satellite)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.99-106
    • /
    • 2011
  • Since the solar energy resource is the main input for sizing any solar photovoltaic system, it is essential to utilize the solar radiation data as an application and development of solar energy system increase. It will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations in Korea and for the more detailed analysis, images taken by geostationary satellite may be used to estimate solar irradiance fluxes at earth"s surface. It is based on the empirical correlation between a satellite derived cloud index and the irradiance at the ground. From the results, the measured data has been collected at 16 different stations and estimated using satellite at 23 different stations over the South Korea from 1982 to 2009. The Result of analysis shows that the annual-average daily global radiation on the horizontal surface is 3.56 kWh/ $m^2$/day and estimated solar radiation fluxes show reliable results for estimating the global radiation with average deviation of -7.27 to +3.65% from the measured values.

방사선 작업종사자의 피폭선량 비교 평가 (Comparative evaluation of radiation exposure in radiation-related workers)

  • 백성민;장은성
    • 한국방사선학회논문지
    • /
    • 제5권4호
    • /
    • pp.195-200
    • /
    • 2011
  • 최근의 방사선 피폭 선량을 조사하여 그 경각심을 일깨워주기 위함이다. 그 분석결과, K병원의 2008년도 평균피폭 선량은 $0.75{\pm}0.26mSv$, 2009년은 $0.67{\pm}0.30mSv$, 2010년은 $0.92{\pm}0.33mSv$였다. P병원은 2008년이 $0.43{\pm}0.13mSv$, 2009년 $0.43{\pm}0.20mSv$, 2010년이 $0.33{\pm}0.85mSv$로 나타났으며, 연령별 평균 피폭선량은 K병원의 20대가 13.39mSv, 30대 8.37mSv, 40대 1.19mSv, 50대 0.28mSv, 60대 0.32mSv로 나타났고 P병원은 20대 0.33mSv, 30대 1.41mSv, 40대 0.83mSv, 50대 1.66mSv, 60대 1.12mSv 였다. 또한 3년간 피폭선량의 평균을 성별로 나누어서 나타냈는데 K병원에서 남자의 피폭선량은 $2.92{\pm}1.03mSv$, 여자의 피폭선량은 $0.94{\pm}0.93mSv$였다. P병원에서의 남자의 피폭 선량은 $0.66{\pm}0.18mSv$이고 여자는 $1.80{\pm}0.60mSv$로 나타났다. 방사선을 취급하는 과별로 받는 년간 평균 피폭 선량은 영상의학과 $1.65{\pm}1.54mSv$, 방사선종양학과 $1.17{\pm}0.82mSv$, 핵의학과 $1.79{\pm}1.42mSv$, 기타 $0.99{\pm}0.51mSv$였으며 상대적으로 저선량율 에너지를 사용하는 핵의학과에서 다른 과와 비교해서 방사선 피폭이 높게 나타났으며(p<0.05), 핵의학과내에서는 특히 동위원소 조작실과 주입실의 년간 평균 피폭량이 $3.69{\pm}1.81mSv$으로 많은 피폭을 받고 있었다(p<0.01). 직종별 연평균 피폭선량은 의사 $1.75{\pm}1.17mSv$, 방사선사 $1.60{\pm}1.39mSv$, 간호사 $0.93{\pm}0.35mSv$, 기타 $1.00{\pm}0.3mSv$로 의사와 방사선사가 다른 직종에 비해 높게 나타났다(p<0.05). 방사선 작업 종사자에 대한 피폭측정 및 평가가 철저히 이루어져 피폭 가능성을 줄이는데 관심과 주의가 필요하며 누적 선량을 최소화하여 방사선 작업 종사자의 건강을 유지하고 증진 시켜야 할 것이다.

Nondestructive Estimation of Average Wood Moisture Content Using Surface Temperature Rise by Radiation Heating and Moisture Gradient

  • Lee, Hyoung-Woo;Kim, Byung-Nam
    • Journal of the Korean Wood Science and Technology
    • /
    • 제27권4호
    • /
    • pp.38-42
    • /
    • 1999
  • Average moisture content of 30mm-thick Korean red pine(Pinus densiflora) was estimated nondestructively and continuously using surface temperature rise by radiation heating and moisture gradient profile in wood. The surface temperature rises increased as surface moisture contents decreased and good relationships were found between surface moisture contents and surface temperature rises at three different feed speeds of 10, 20 and 30 m/min. Average moisture content could be described as a function of surface moisture content and wood thickness.

  • PDF

직무피폭의 선량제약치에 관한 연구: 분야별 전문가 의견 중심으로 (A Study on the Dose Constraints for Occupational Exposure: Focusing on Expert Opinions by Field of Ridiation Industry)

  • 박일;박찬희;정규환;박찬호;김용건;박태진
    • 방사선산업학회지
    • /
    • 제17권1호
    • /
    • pp.61-67
    • /
    • 2023
  • A Study on the Introduction of Dose Constraints for Occupational Exposures: Focusing on Experts' Opinions by Field of Radiation Industry. The International Commission on Radiological Protection suggests Justification, Optimization, and Dose Limits as the three principles of radiological protection, among which, as a means of protection optimization, ICRP 103 recommends to set dose constraints. In this study, opinions are collected from experts in each category of radiation industries for stakeholder participation to qualify dose constraints. A guidance and questionnaire for analyzing the dose constraints have been developed for their collection, and opinions were collected from radiation protection experts in selected categories. 20 out of 22 experts, consisted with 91%, have assessed the dose constraints setting is necessary, and 2 experts, consisted with 9%, assessed it is unnecessary. The average of dose constraint presented by experts for RI production institutions is to be the highest level of 15.3 mSv, and light-water reactors (14.6 mSv), non-destructive inspection (14.4 mSv), heavy-water reactor and medical institutes (13.9mSv) is to be above the overall average dose constraint. In case of public institutions, the average dose constraint is to be 8.6mSv, and research institutions (8.8mSv), educational institutions (9.6 mSv), waste disposal sites (9.7 mSv), and general industries (10.6 mSv) are resulted to below the overall average dose constraint. As for the means of setting dose constraints, 8 experts out of 22 suggested setting dose constraints for each specific industry or task. And, 5 experts especially suggest setting dose constraints for the specific groups with relatively high exposure, such as workers with above the record levels. As a countermeasure for workers who exceed the dose constraints, 15 experts out of 22 expressed that the cause analyses for them and preparation for a plan of reducing them are necessary.

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

전립선암 환자의 복부압박에 따른 표적 움직임 분석 (Analysis of target volume motion followed by induced abdominal compression in tomotherapy for prostate cancer)

  • 오정훈;정건아;정원석;조준영;김기철;최태규
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.69-76
    • /
    • 2014
  • 목 적 : 외부 압박을 통해 전립선암 환자의 복강 내 압력을 안정화시켜 움직임을 감소하여 치료 간(interfraction)과 치료 중(intrafraction)에 변화를 측정하여 평가하고자 시행하였다. 대상 및 방법 : 10명의 전립선환자들은 전체 치료과정동안 MVCT 스캔을 통해 치료 전과 후에 걸쳐 환자 당 60개의 영상을 획득하였고 획득한 좌우방향(X), 상하방향(Y), 전후방향(Z), 회전방향(Roll)에 대한 Shift 값들을 이용하여 복부 압박 시 치료 간 치료준비 변화와 치료 중 표적 움직임의 상호 연관성을 분석하였다. 결 과 : 치료 간의 움직임 변화는 평균 좌우방향(X)에서 $0.65{\pm}2.32mm$, 상하방향(Y)에서 $1.41{\pm}4.83mm$, 전후방향(Z)에서 $0.73{\pm}0.52mm$, 회전방향(Roll)에서 $0.96{\pm}0.21^{\circ}$로 나타났다. 치료 중 움직임 변화는 평균 좌우방향(X)에서 $0.15{\pm}0.44mm$, 상하방향(Y)에서 $0.13{\pm}0.44mm$, 전후방향(Z)에서 $0.24{\pm}0.64mm$, 회전방향(Roll)에서 $0.1{\pm}0.9^{\circ}$로 나타났다. 결 론 : 전처치과정과 외부에서 복부압박을 통한 전복부의 움직임을 제한한다면 치료동안에 내부 장기와 환자의 움직임을 감소시켜 보다 적은 여유(margin)로 계획용 표적체적(PTV)을 생성할 수 있어서 정상조직의 부작용 증가 없이 더욱 이상적인 선량 체적을 얻을 수 있을 것으로 사료된다.

운량과 일조시간에 의한 태양자원 예측 (Solar Radiation Estimation Using Cloud Cover and Hours of Bright Sunshine)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.126-129
    • /
    • 2012
  • In this work a new correlation has been made to predict the solar radiation for 16 different areas over Korea by estimating the regression coefficients taking into account cloud hours of bright sunshine. Particularly, the multiple linear regression model proposed shows reliable results for estimating the global radiation on a horizontal surface with monthly average deviation of -0.26 to +0.53% and each station annual average deviation of -1.61 to +1.7% from measured values.

  • PDF