• Title/Summary/Keyword: Auxiliary Room

Search Result 57, Processing Time 0.025 seconds

A Study on the Influence of Hotel's Architectural Attributes on Operating Revenue - Focused on Tourist Hotel in Seoul - (호텔의 건축적 속성이 운영 수익에 주는 영향에 관한 연구 - 서울지역 관광호텔을 중심으로 -)

  • Kim, Hyun-Kwang;Whang, Hee-Joon
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.8
    • /
    • pp.43-50
    • /
    • 2018
  • The purpose of this study is to analyze the effect of architectural attributes on operating revenue by concentrating on the facility side and to investigate how much individual architectural factors can affect operating revenue. The time range of this study is limited to 2015, and the spatial range is limited to a tourist hotel in Seoul that can be easily surveyed and verified. The analysis method is to confirm the significance and influence of each attribute through regression analysis. According to the results, The room part such as number of rooms or area showed a relatively low correlation with "revenue per available room (Rev.PAR)" than "average daily rate (ADR)", but showed a high correlation with non - architectural attributes such as auxiliary facilities and chain. This shows that factors that influence the operating profit of hotel are not the part of the room but the other factors such as the auxiliary facilities work more. In addition, the presence of spa and the number of auxiliary facilities in the hotel have a positive effect on the operating profit of the hotel due to the non - architectural attributes. This is expected to provide a new direction for future research in studying hotel facilities.

A Study on Thermal and Fluid Characteristics inside Engine Room of Auxiliary Power Unit for Tracked Vehicle (궤도차량용 보조동력장치 엔진룸 내부 열유동 특성에 관한 연구)

  • Lee, Tae-Eui;Suh, Jeong-Se;Jeong, Sang-Hwan;Park, Young-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.85-93
    • /
    • 2009
  • This research is intended to grasp the characteristics of heat flow inside auxiliary power device engine room to obtain the design basic data through numerical analysis and experiment. For experiment cost reduction, numerical analysis was done to obtain quantitative data by observing the change in temperature distribution of major parts according to changes in normal condition, incompressible condition, engine surface heat emission rate and absorption temperature with the use of commercial STAR-CD. The experiment was done by grasping the temperature distribution of major interested parts inside engine room in loaded and unloaded conditions during engine operation. The temperature distribution data here will serve as useful design data during APU engine room designing.

Determination of Sizes of the Pump Rooms in Korean Nuclear Power Plants (한국형 원자력발전소 펌프실 면적 산정 방안)

  • Lee, Hyo-Sung;Koh, Churl-Kyun;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.9 no.2
    • /
    • pp.36-41
    • /
    • 2013
  • For areas installed with one pump, the trend for expected sizes of pump room areas is observed once pump power and floor dimensions are provided. However, these pump rooms with auxiliary charging pumps, turbine driven auxiliary feedwater pumps, and pump rooms with a separate valve room have unique ways to determine the pump room area. No definite trends are identified for areas installed with two pumps using pump power and floor dimensions. The relationship between pump power and floor dimensions is also unable to be found.

  • PDF

Operation Performance Evaluation on Auxiliary Heating Device to Prevent Condensation adjacent to Built-in Furniture of Apartment Units in Winter (기존 공동주택 붙박이장에서 겨울철 결로 방지를 위한 보조난방장치 운전 성능 평가)

  • Lee, Chae-Lyn;Lee, Hyun-Hwa;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.567-578
    • /
    • 2018
  • The purpose of this study was to evaluate condensation prevention for condensation vulnerable areas around built-in furniture of apartment buildings by applying auxiliary heating device. Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To solve these problems, auxiliary heating device was developed and could be installed. The aim of paper is to analyze the thermal environment around the built-in furniture which were applied and not applied auxiliary heating device in winter. In results, it was possible to increase the surface temperature of vulnerable areas around built-in furniture by applying auxiliary heating device, and to minimize condensation problems by using the minimum device.

The Diagnosis and Evaluation of Vibration and Noise in Vessel (선체에서 발생하는 진동과 소음의 진단 및 평가)

  • Gu, Dong-Sik;Lee, Jeong-Hwan;Choi, Byeong-Keun;Kim, Won-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.1
    • /
    • pp.42-49
    • /
    • 2008
  • Most of vessels are not evaluated for their vibration and noise effects to human body. The vibration and noise generated by engine and auxiliary machine in vessel is a negative element for seamen. Therefore, in this paper, the diagnosis and evaluation of vibration and noise from vessel is accomplished by a shipbuilding corporation. The vibration and noise transferred from engine room and auxiliary machine was measured during the steady-state operation, and the vibration and noise map of vessel was made. Also, in order to evaluate the ship environment for human, the diagnosis is carried out on the base of measurement results.

CCDP Evaluation of the Eire Areas in NPP Applying CEAST Model (II) (화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가(II))

  • Lee Yoon-Hwan;Yang Joon-Eon;Kim Jong-Hoon;Kim Woon-Byung
    • Fire Science and Engineering
    • /
    • v.19 no.3 s.59
    • /
    • pp.20-27
    • /
    • 2005
  • This paper evaluates the fire safety level of eight pump rooms in the nuclear power plant using a fire model, CFAST We estimate the Conditional Core Damage Probability (CCDP) of each room based on the analyzed results of CFAST Eight rooms located on the primary auxiliary building of the nuclear power plant are high pressure safety injection pump room A/B, low pressure safety injection pump room Am. containment sprdy pump room A/B, and motor-driven auxiliary feed water pump room A/B. The upper layer gas temperature of each room is estimated and the integrity of cable is reviewed. Based on the results, the integrity of the cable located at the upper part of compartment is maintained without thermal damage. The Conditional Core Damage Probability Is reduced to half of the old values. Accordingly, the fire safety assessment for eight pump rooms using the fire model will be capable of reducing the uncertainty and to develop a more realistic model.

Dynamic simulation of a solar absorption cooling system (태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션)

  • 정시영;조광운
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

A Flow Analysis of a Refrigeration Warehouse where an Unusual Death of an Operator Occurred by Deficiency of Oxygen

  • Park, Chan-Seong;Moon, Jung-Eun;Kim, Yoon-Ho;Kim, Jin-Pyo
    • International Journal of Safety
    • /
    • v.5 no.2
    • /
    • pp.29-33
    • /
    • 2006
  • A numerical flow analysis of the case of a refrigeration warehouse where an unusual death of an operator occurred by deficiency of oxygen is performed by using STAR-CD program of the computational fluid dynamics (CFD) code. The refrigeration room of the warehouse for storing the fruits maintains an atmosphere of 95% nitrogen and 5% oxygen by volume. When the operator was found dead in the refrigeration room, the room was in normal operating conditions except for the fact that the auxiliary door had been left open. For the flow analysis, unsteady 3-dimensional natural convection with mass transfer is considered. The flow analysis result is compared with the oxygen concentration level measured against time during on-site investigation. The change in oxygen concentration level in the warehouse due to the opening of the auxiliary door is found to be negligible.