• 제목/요약/키워드: Auxiliary Room

검색결과 57건 처리시간 0.024초

호텔의 건축적 속성이 운영 수익에 주는 영향에 관한 연구 - 서울지역 관광호텔을 중심으로 - (A Study on the Influence of Hotel's Architectural Attributes on Operating Revenue - Focused on Tourist Hotel in Seoul -)

  • 김현광;황희준
    • 대한건축학회논문집:계획계
    • /
    • 제34권8호
    • /
    • pp.43-50
    • /
    • 2018
  • The purpose of this study is to analyze the effect of architectural attributes on operating revenue by concentrating on the facility side and to investigate how much individual architectural factors can affect operating revenue. The time range of this study is limited to 2015, and the spatial range is limited to a tourist hotel in Seoul that can be easily surveyed and verified. The analysis method is to confirm the significance and influence of each attribute through regression analysis. According to the results, The room part such as number of rooms or area showed a relatively low correlation with "revenue per available room (Rev.PAR)" than "average daily rate (ADR)", but showed a high correlation with non - architectural attributes such as auxiliary facilities and chain. This shows that factors that influence the operating profit of hotel are not the part of the room but the other factors such as the auxiliary facilities work more. In addition, the presence of spa and the number of auxiliary facilities in the hotel have a positive effect on the operating profit of the hotel due to the non - architectural attributes. This is expected to provide a new direction for future research in studying hotel facilities.

궤도차량용 보조동력장치 엔진룸 내부 열유동 특성에 관한 연구 (A Study on Thermal and Fluid Characteristics inside Engine Room of Auxiliary Power Unit for Tracked Vehicle)

  • 이태의;서정세;정상환;박영식
    • 한국정밀공학회지
    • /
    • 제26권12호
    • /
    • pp.85-93
    • /
    • 2009
  • This research is intended to grasp the characteristics of heat flow inside auxiliary power device engine room to obtain the design basic data through numerical analysis and experiment. For experiment cost reduction, numerical analysis was done to obtain quantitative data by observing the change in temperature distribution of major parts according to changes in normal condition, incompressible condition, engine surface heat emission rate and absorption temperature with the use of commercial STAR-CD. The experiment was done by grasping the temperature distribution of major interested parts inside engine room in loaded and unloaded conditions during engine operation. The temperature distribution data here will serve as useful design data during APU engine room designing.

한국형 원자력발전소 펌프실 면적 산정 방안 (Determination of Sizes of the Pump Rooms in Korean Nuclear Power Plants)

  • 이효승;고철균;문승재
    • 플랜트 저널
    • /
    • 제9권2호
    • /
    • pp.36-41
    • /
    • 2013
  • 펌프실 내 펌프가 1대 배치되는 경우 펌프 동력과 펌프기초 면적이 주어지면 펌프실 면적을 찾을 수 있다. 다만, 일부 펌프는 펌프와 발전소 배치 특이성에 따라 펌프실 면적이 결정된다. 그러나 펌프실 내 펌프가 2대 배치되는 경우 펌프 동력과 펌프기초 면적을 이용한 펌프실 면적을 구하는 연계관계를 찾을 수 없다. 그리고 펌프 동력과 펌프기초 면적의 연계관계도 찾을 수 없다.

  • PDF

기존 공동주택 붙박이장에서 겨울철 결로 방지를 위한 보조난방장치 운전 성능 평가 (Operation Performance Evaluation on Auxiliary Heating Device to Prevent Condensation adjacent to Built-in Furniture of Apartment Units in Winter)

  • 이채린;이현화;임재한;송승영
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.567-578
    • /
    • 2018
  • The purpose of this study was to evaluate condensation prevention for condensation vulnerable areas around built-in furniture of apartment buildings by applying auxiliary heating device. Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To solve these problems, auxiliary heating device was developed and could be installed. The aim of paper is to analyze the thermal environment around the built-in furniture which were applied and not applied auxiliary heating device in winter. In results, it was possible to increase the surface temperature of vulnerable areas around built-in furniture by applying auxiliary heating device, and to minimize condensation problems by using the minimum device.

선체에서 발생하는 진동과 소음의 진단 및 평가 (The Diagnosis and Evaluation of Vibration and Noise in Vessel)

  • 구동식;이정환;최병근;김원철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.42-49
    • /
    • 2008
  • Most of vessels are not evaluated for their vibration and noise effects to human body. The vibration and noise generated by engine and auxiliary machine in vessel is a negative element for seamen. Therefore, in this paper, the diagnosis and evaluation of vibration and noise from vessel is accomplished by a shipbuilding corporation. The vibration and noise transferred from engine room and auxiliary machine was measured during the steady-state operation, and the vibration and noise map of vessel was made. Also, in order to evaluate the ship environment for human, the diagnosis is carried out on the base of measurement results.

화재모델 CFAST를 이용한 원전 화재구역의 CCDP평가(II) (CCDP Evaluation of the Eire Areas in NPP Applying CEAST Model (II))

  • 이윤환;양준언;김종훈;김운형
    • 한국화재소방학회논문지
    • /
    • 제19권3호
    • /
    • pp.20-27
    • /
    • 2005
  • 본 논문에서는 화재 모델 CFAST를 사용하여 원자력발전소에 있는 8개 펌프실의 화재 안전 수준을 평가해 보고, 그 결과를 조건부 노심손상확률에 반영하여 분석해 보았다. 분석 대상 구역은 원자력발전소 일차보조건물에 위치한 고압안전주입 펌프실 A/B,저압안전주입 펌프실 A/B, 격납건물 살수 펌프실 A/B 및 모터구동 보조급수 펌프실 A/B 총 8곳이었다. 각 화재구역의 상부층 가스 온도를 분석하였으며, 분석 결과를 바탕으로 상부층에 위치한 케이블의 손상 유무를 파악하였다. 분석 결과에 의하면 총 8개 화재구역의 상부층 케이블은 건전성을 유지하는 것으로 확인되었다. 케이블의 건전성 평가 결과를 바탕으로 각 화재구역의 조건부 노심손상확률을 평가한 결과, 기존의 보수적인 가정 하에 수행된 화재위험도분석 결과보다 약 2배정도 감소하는 보다 현실적이고 불확실성이 감소한 결과를 도출할 수 있었다.

태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션 (Dynamic simulation of a solar absorption cooling system)

  • 정시영;조광운
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

A Flow Analysis of a Refrigeration Warehouse where an Unusual Death of an Operator Occurred by Deficiency of Oxygen

  • Park, Chan-Seong;Moon, Jung-Eun;Kim, Yoon-Ho;Kim, Jin-Pyo
    • International Journal of Safety
    • /
    • 제5권2호
    • /
    • pp.29-33
    • /
    • 2006
  • A numerical flow analysis of the case of a refrigeration warehouse where an unusual death of an operator occurred by deficiency of oxygen is performed by using STAR-CD program of the computational fluid dynamics (CFD) code. The refrigeration room of the warehouse for storing the fruits maintains an atmosphere of 95% nitrogen and 5% oxygen by volume. When the operator was found dead in the refrigeration room, the room was in normal operating conditions except for the fact that the auxiliary door had been left open. For the flow analysis, unsteady 3-dimensional natural convection with mass transfer is considered. The flow analysis result is compared with the oxygen concentration level measured against time during on-site investigation. The change in oxygen concentration level in the warehouse due to the opening of the auxiliary door is found to be negligible.