• 제목/요약/키워드: Automotive Air Conditioning System

검색결과 226건 처리시간 0.03초

수직 Rayleigh 유동내의 입자 거동 해석 (Analysis of Particles Motion in Vertical Rayleigh Flow)

  • 고석보;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권6호
    • /
    • pp.447-456
    • /
    • 2007
  • Suspended particles behavior when they go through a vertical riser with heat transfer is of significant concern to system designers and operators in pneumatic transport, various processes such as in chemical, pharmaceutical and food industries. When it comes with the energy system, that knowledge is critical to the reliable design practices of related equipment as heat exchangers, especially in the phase of system scale-up. Without haying a good understanding of the related physics, many scale-up practices based on their pilot plant experience suffer from unexpected behaviors and problems of unstable fluidization typically associated with excessive pressure drop, pressure fluctuation and even unsuccessful particle circulation. In the present study, we try to explain the observed phenomena with related physics, which may help understanding of our unanswered experiences and to provide the designers with more reliable resources for their work. We selected hot exhaust gas with solid particle that goes through a heat exchanger riser as our model to be considered. The effect of temperature change on the gas velocity, thermodynamic properties, and eventually on the particles motion behavior is reviewed along with some heat transfer analyses. The present study presents an optimal riser length at full scale under given conditions, and also defines the theoretical limiting length of the riser. The field data from the numerical analysis was validated against our experimental results.

설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권12호
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

고분자불질 및 계면활성제의 유동마찰 저감 특성 비교 연구 (A Comparison Study on Drag Reduction Characteristics of Polymer and Surfactant as Drag Reduction Additive)

  • 조성환;유재성;김성수;정상훈;윤석만
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.398-403
    • /
    • 2010
  • The drag reduction(DR) of non-ionic surfactant and polymer according to the variation of fluid velocity, temperature and surfactant concentration was investigated experimentally. For this experiment, the kind of surfactant was non ionic amine-oxide and the kinds of polymer were polyacrylamide and xantan gum. An experimental apparatus equipped with one water storage tanks was built and two flow meters, two pressure gauges for data logging system was installed. Results showed that the kinds of polymer, polyacrylamide and xantan gum, had DR of below 20% for below 500 ppm in fluid temperature of $50{\sim}80^{\circ}C$. But the kind of surfactant, amine oxide, had DR of above 40% for 500~1000 ppm in fluid temperature of $50{\sim}80^{\circ}C$. As a result, amin oxide showed better materials to use to the district heating system.

Research on One Dimensional Dynamic Model in Water Transportation of PEM Fuel Cell

  • Bakhtiar, Agung;You, Jin-Kwang;Park, Jong-Bum;Hong, Boo-Pyo;Choi, Kwang-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.382-387
    • /
    • 2012
  • Water balance has a significant impact on the overall fuel cell system performance. Proper water management should provide an adequate membrane hydration and avoidance of water flooding in the catalyst layer and gas diffusion layer. Considering the important of advanced water management in PEM fuel cell, this study proposes a simple one dimensional water transportation model of PEM fuel cell for use in a dynamic condition. The model has been created by assumption that the output is the water liquid saturation difference. The liquid saturation change is the total difference between the additional water and the removal water on the system. The water addition is obtained from fuel cell reaction and the electro osmotic drag. The water removal is obtained from capillary transport and evaporation process. The result shows that the capillary water transport of low temperature fuel cell is high because the evaporation rate is low.

  • PDF

하천수 열원 2단압축 열펌프의 최적 중간압에 관한 실험적 연구 (An Experimental Study on the Optimal Intermediate Pressure of a 2-Stage Compression Heat Pump Using River Water)

  • 박차식;정태훈;주영주;김용찬
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.333-339
    • /
    • 2009
  • The objective of this study is to predict optimal intermediate pressure of a 2-stage compression heat pump system using river water. To determine the maximum performance of the 2-stage compression heat pump system, the experimental evaluations on the 2-stage compression cycle were carried out under various operating conditions. Electronic expansion valves were applied to control intermediate pressure and superheat. Based on the experimental data, an empirical correlation for predicting optimal intermediate pressure which considering cycle operating parameters was developed. The present correlation was verified by comparing the predicted data with the measured data. The predictions showed a good agreement with the measured data within a relative deviation of ${\pm}4%$ at various operating conditions.

베이즈 분류기를 이용한 수냉식 냉동기의 고장 진단 방법에 관한 실험적 연구 (An Experimental Study on Fault Detection and Diagnosis Method for a Water Chiller Using Bayes Classifier)

  • 이흥주;장영수;강병하
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.508-516
    • /
    • 2008
  • Fault detection and diagnosis(FDD) system is beneficial in equipment management by providing the operator with tools which can help find out a failure of the system. An experimental study has been performed on fault detection and diagnosis method for a water chiller. Bayes classifier, which is one of classical pattern classifiers, is adopted in deciding whether fault occurred or not. Failure modes in this study include refrigerant leakage, decrease in mass flow rate of the chilled water and cooling water, and sensor error of the cooling water inlet temperature. It is possible to detect and diagnose faults in this study by adopting FDD algorithm using only four parameters(compressor outlet temperature, chilled water inlet temperature, cooling water outlet temperature and compressor power consumption). Refrigerant leakage failure is detected at 20% of refrigerant leakage. When mass flow rate of the chilled and cooling water decrease more than 8% or 12%, FDD algorithm can detect the faults. The deviation of temperature sensor over $0.6^{\circ}C$ can be detected as fault.

$CO_2$ 냉동시스템용 PAG오일과 POE오일의 항흡습성에 관한 실험적 연구 (An Experimental Study on Non-hygroscopic Propertiy of PAG and POE Oils for a $CO_2$ Refrigeration System)

  • 이성광;강병하
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.388-393
    • /
    • 2008
  • This study has been conducted to select the suitable refrigeration oil for a $CO_2$ refrigeration system. Non-hygroscopic property of refrigeration oils is one of the most important properties for refrigeration oils. PAG and POE oils are considered as test oils in this study. Transient variation of water content of PAG and POE oils was measured for 3 different vessels in the environmental conditions, such as in the range of temperature $25^{\circ}C$ to $40^{\circ}C$ and relative humidity 40% to 85%. The results obtained that water content of both POE and PAG is increased with an increase in the contact area with ambient for 3 different vessels. It is also found that water content of both POE and PAG is increased as the ambient temperature and relative humidity is increased. Non-hygroscopic property of POE oil is found to be much superior than that of PAG oil.

PEM연료전지의 수분전달에 있어서 1차원 해석을 수행한 동적모델에 관한 연구 (Analysis on a Dynamic Model with One Dimension in Water Transportation of PEM Fuel Cell)

  • 아궁박티르;홍부표;유진광;김영복;윤정인;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.118-123
    • /
    • 2012
  • Water balance has a significant impact on the overall fuel cell performance. Maintenance of proper water management should provide an adequate membrane hydration and avoidance of water flooding in the catalyst layer and gas diffusion layer. Considering the important of advanced water management in PEM fuel cell, this study proposes a simple one dimensional water transportation model of PEM fuel cell for use in a dynamic condition. The model has been created by assumption that the output is the water liquid saturation difference. The liquid saturation change is the total difference between the additional water and the removal water on the system. The water addition is obtained from fuel cell reaction and the electro osmotic drag. The water removal is obtained from capillary transport and evaporation process. The result shows that the capillary water transport of low temperature fuel cell is high because the evaporation rate is low.

고분 공조시스템의 운전특성 및 제습부하에 관한 연구 (A Study on the Performance and Dehumidification Load of an HVAC System for Conservation of Ancient Tombs)

  • 박진양;고석보;전희호;전용두;이금배
    • 설비공학논문집
    • /
    • 제19권3호
    • /
    • pp.253-262
    • /
    • 2007
  • Although the importance of good conservation of historical sites including ancient royal tombs is well aware, still not much attention has been paid for facilities to realize it. There are numerous ancient royal tombs spread in Korean peninsula which are opened and some of them are selectively on display for public access. However, the conservation measures of these sites have not been seriously investigated. Even the level of understanding of the underground environment of tombs is not satisfactory. In the present study, we focus on the dehumidification loads to maintain appropriate conservation conditions in terms of temperature and humidity. Two experimental tombs different in size were built in KNU (Kongju National University) campus with the dimensions ($L{\times}W{\times}H$) of $1.0m{\times}2.8m{\times}1.0m\;and\;1.3m{\times}3.0m{\time}1.2m$, respectively, HVAC systems are installed to maintain a suitable condition for conservation, i.e., $22{\pm}2^{\circ}C$ in temperature and $55{\pm}5%$ in relative humidity. The condensed water are measured to estimate the dehumidification loads while the temperature and the humidity inside the tombs were maintained within the specified range.

버섯재배사의 공조시스템 설계에 대한 연구 (A study on the design of air conditioning system in the mushroom cultivation greenhouse)

  • 류경진;손재환;한창우;나규동
    • 한국산학기술학회논문지
    • /
    • 제18권2호
    • /
    • pp.743-750
    • /
    • 2017
  • 온실에서 버섯을 재배할 때 균일한 온도 분포가 되도록 하는 것이 중요하다. 지하 공기를 이용하여 비닐 하우스, 버섯재배사에 일정 온도의 공기를 공급하며 균일하게 유지하게 한다. 버섯재배사 구조는 7단 4열의 다배열 균상들 사이의 공기 흐름을 원활히 하고 위, 아래 균상 간의 환경 차이를 방지한다. 0.5m/s의 속도로 유입되는 공기는 초기 내부온도 간의 차이에 따라 밀도 차에 따른 부력에 의한 효과 역시 무시할 수 없으며, 온실내의 유동 해석을 통해 적정 온도가 균등하게 분포하도록 FCU(Fan Coil Unit)와 Fan의 위치를 정해야 한다. 본 연구에서는 유동해석을 통해 FCU와 Fan으로 구성된 샌드위치 단열 패널형의 버섯재배사의 공조시스템을 설계할 수 있었다. 그리고 재배사 내부의 온도 및 유동 해석을 통해 FCU(유입구)와 Fan(출구)의 위치가 서로 다른 Case에서 유입되는 공기의 순환 경로가 길어지면서 비교적 균일한 온도분포를 갖는데 유리함을 알 수 있었다. 따라서 이러한 환경 개선을 통해 버섯의 생육 및 품질 균일성을 도모할 수 있었다.