• Title/Summary/Keyword: Attenuation Measurement

Search Result 388, Processing Time 0.024 seconds

A study of estimation for excess attenuation of Noise propagated on the ground (지표면상을 전파하는 소음의 초과감쇠 산정방법에 관한 연구)

  • Oh, J.E.;Kim, D.G.;Yim, T.K.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.20-25
    • /
    • 1988
  • This study is to explain the characteristic of excess attenuation on the ground through the outdoors experiment about noise propagation and the reduced model experiment of acoustic. The outdoors experiment on the attenuation of noise propagation was tried with the small engine that had large acoustic output, and then it was conformed that there was relationship between the excess attenuation calculated by measurement from distance attenuation and Log(D/(Hs+Hr)). As a result, it was found that the attenuation of noise propogation depended upon the direction of the wind and frequency and was regressed in a straight line. And the numerical values of excess attenuation on the ground could be calculated by regarding Log(D/(Hs+Hr)) as a parameter with an airing resistance $\sigma$. It was found that when the mean square error between the excess attenuation calculated by measurement and the value calculated by a fomula $L=-20Log\mid1+(r_1/r_2)Qexp(ik, \bigtriangleup r)\mid$ about optional $\sigma$ was least, the optimal decision of u was made. As the characteristic of model is the model experiment on a reduced scale of 1 to 40, It was conformed that it corresponds enough with the measurement value with measuring the distance attenuation in the large anecoic chamber.

  • PDF

An Onboard Measurement System of Ultrasonic Velocity and Attenuation using the Wavelet Transform

  • Cho, Seog-bin;Ha, Sung-kil;Jung, Sung-Yun;Baek, Kwang-ryul
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1826-1828
    • /
    • 2004
  • In this paper, we present an ultrasonic velocity and attenuation measurement system. There are many ultrasonic measurement methods that are used in nondestructive testing applications. They include material property determination, microstructural characterization, and flaw detection. Ultrasonic parameters such as velocity and attenuation are most commonly used in them. Advanced signal analysis which is called "ime-frequency analysis"has been used widely in nondestructive evaluation applications. Wavelet transform is the most advanced technique for processing signals with time-varying spectra. Using the echo waveform gathered by the designed hardware system, we performed simulation of the signal processing algorithms. Then the algorithm is implemented on the system.

  • PDF

Prediction of Highway Traffic Noise-calculation of Sound Attenuation during Propagation (고속도로 교통소음 예측-전달감쇠 산정)

  • 조대승;김진형;최태묵;오정한;김성훈
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.3
    • /
    • pp.236-242
    • /
    • 2002
  • This paper presents some advanced and supplemental methods to enhance the accuracy In case of calculating geometric divergence attenuation, attenuation by multiple screening structures, ground attenuation at unflat surfaces of sound during propagation outdoors by the methods specified in ISO 9613-2. Moreover, a calculation method for considering short-term wind effect, specified in ASJ Model-1998, is also introduced. To verity the accuracy of adopted methods, we have carried out highway traffic noise prediction and measurement at tile twelve locations appearing representative road shapes and structures, such as flat, retained cut, elevated, barrier-constructed roads. From the results, we have confirmed the predicted results show good correspondence with the measured at direct, diffracted and reflected sound fields within 30 m from the center of near side lane.

Measurement of Crack Length by Ultrasonic Attenuation Coefficient (초음파 감쇠계수에 의한 균열길이의 측정)

  • Chung, Nam-Yong;Park, Sung-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.386-393
    • /
    • 2004
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

Nondestructive Creep Damage Evaluation of High-Temperature Pipelines by Ultrasonic Attenuation Measurement and Electric Resistance Methods (초음파 감쇠 및 전기저항 측정법에 의한 발전소 고온배관의 크리프손상 평가)

  • Lee, In-Cheol;Kil, Du-Song;Gung, Gye-Jo;Cho, Yong-Sang;Lee, Sang-Guk
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3 s.33
    • /
    • pp.100-107
    • /
    • 1999
  • Due to the high temperature and pressure, the materials of pipeline in power plant are degraded by creep damage. So far, many conventional measurement techniques such as replica method, electric resistance method, adn hardness test method for creep damage have been used. Among them, the replica method has mainly been used for the inspection of components. But this technique is restricted to the applications at the surface of the objects and cannot be used to material inside. In this paper, the measuring methods of evaluation by using ultrasonic attenuation and electric resistance for the creep detection of creep damage in the form of cavities on grain boundaries or intergranular microcracks were carried out. Absolute measuring method of quantitave ultrasonic attenuation technique for 1Cr0.5Mo material degradation was analyzed for determining the creep degradation steps using life prediction formula. As a result of measurement for creep specimens, we founded that the coefficient of utrasonic attenuation was increased as the increase of creep life fracton(${phi}c$) and the decreasing rate of wlwctric resistance was also increased.

  • PDF

Left Ventricular Volume Measurement by Count Method with Attenuation Correction in Gated Blood Pool scan (심장풀스캔에서 방사능 계측법에 의한 좌심실 용적의 측정 -조직 감쇄의 보정에 의한 연구-)

  • Bom, Hee-Seung;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.1
    • /
    • pp.33-37
    • /
    • 1987
  • Attenuated end-diastolic and end-systolic left ventricular counts which obtained from cardiac gated blood pool scan were corrected using experimentally calculated attenuation coefficient $(\mu=0.13/cm)$ and depth of center of left ventricle. This method was confirmed to be correct experimentally using phantom balloon. To compare the accuracy of attenuated and attenuation-corrected left ventricular volume measurement, authors studied 10 patients with ischemic heart disease who underwent both gated blood pool scan and X-ray contrast ventriculography within a week. The attenuated and attenuation-corrected left ventricular volume measured by count method correlated with contrast ventriculographic volumes; however, attenuation corrected measurement was correlated more closely.

  • PDF

Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study (비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석)

  • Jung, Chang-Hoon;Park, Jin-Hee;Hwang, S.M.
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.4
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

Measurement of Rain Induced Attenuation using the Beacon Signal of Koreasat-3

  • Choi, Dong-You;Park, Chang-Gyun
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.3
    • /
    • pp.119-123
    • /
    • 2004
  • This paper presents here the results of the measurements of rain-induced attenuation in the vertically polarized signal propagating at 12.2525 GHz during some rain events, which occurred in the rainy wet season of the year 2001 at Yong-in, Korea(temperate climate). The attenuation measured experimentally was compared with that obtained using the International Telecommunication Union Radio Communication Sector(ITU-R) model, the SAM model and the Global model. In this paper, measured results are in good agreement with the ITU-R prediction.

The Research on the Simultaneous Examination of Thyroid Uptake Measurement and Thyroid Scan using Attenuation Filter (감쇄필터를 이용한 갑상선섭취율 측정과 갑상선스캔의 동시검사법 연구)

  • Lee, Hyo-Yeong;Kim, Jong-Eon;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.309-313
    • /
    • 2011
  • It is necessary for patients to wait twice for the thyroid examination of thyroid uptake measurement and thyroid scan by using $^{99m}Tc$-pertechnetate. In the study, a method of simultaneous examination of thyroid uptake measurement and thyroid scan by one intravenous injection of $^{99m}Tc$-pertechnetate was suggested by using attenuation filter. As a result, there was a significant correlation between control group and experimental group according to existence of attenuation filter. Consequently, the simultaneous examination of thyroid uptake measurement and thyroid scan by one intravenous injection can be applied clinically.