DOI QR코드

DOI QR Code

초음파 감쇠계수에 의한 균열길이의 측정

Measurement of Crack Length by Ultrasonic Attenuation Coefficient

  • 정남용 (숭실대학교 기계공학과) ;
  • 박성일 (숭실대학교 대학원 기계공학과)
  • 발행 : 2004.04.01

초록

In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

키워드

참고문헌

  1. Chung, N. Y., Park, S. L., Lee, M. D., 2001, 'Detection of Interface Crack Using Ultrasonic Method in Adbesively Bonded Joint,' Transaction of the KSME, A, Vol. 25, No. 3, pp. 415-423
  2. Lee, J. H., Choi, S. W., 2000, 'Crack Size Determination Through Neural Network Using Back Scattered Ultrasonic Signal,' Transaction of the KSME, A, Vol. 24, No. 1, pp. 52-61
  3. Derouiche, Z., 1995, 'Ultrasonic Characterization of Heterogeneous Materials Using a Stochastic Approach,' J. Acoust. Soc. Am., Vol. 97, No. 4, pp. 2304-2315 https://doi.org/10.1121/1.411955
  4. Moriyama, S., Kimura, K., 1998, 'Effect of Surface Roughness on Sensitivity of Ultrasonic Normal Beam Testing,' J. JSNT, Vol. 47, No, 5, pp. 315-321
  5. Silk, M. G., 1987, 'Change in Ultrasonic Defect Location and Sizing,' NDT International, Vol. 20, No. 1, pp. 9-14 https://doi.org/10.1016/0308-9126(87)90367-1
  6. Chiou, C. P., Schmerr, L. W., 1991, 'A Quasi-Pulse-Echo Technique for Ultrasonic Flaw Classification,' Ultrasonic, Vol. 29, pp. 471-481 https://doi.org/10.1016/0041-624X(91)90078-M
  7. Paradis, L., Srruys, Y., 1986, 'A Time-of-Flight Method for Crack Evaluation Using Focused Ultrasonic Probes,' Meterials Evaluation, pp. 568-570
  8. Ping, W., Stepinski, T., 2000, 'Quantitative Estimation of Ultrasonic Attenuation in a Solid in the Immersion Case with Correction of Diffraction Effects,' Ultrasonics., Vol. 38, pp. 481-485 https://doi.org/10.1016/S0041-624X(99)00037-2
  9. Albert, S. B., Robert, E. G., 1991, 'Ultrasonic Testing,' Nondestructive Testing Handbook., Vol. 7, pp. 377-390
  10. Joseph, L. R., Paul, A. M., 1974, 'Ultrasonic Signal-Processing Concepts for Measuring the Thickness of Thin Layer,' ASNT Material Evaluation., Vol. 32, No. 12, pp. 225-249
  11. Djelouah, H., Bocquet, M., 2000, 'Application of Ultrasonic Reflection Mode Conversion Transducers in NDE,' NDT&E International., Vol. 33, pp. 91-99 https://doi.org/10.1016/S0963-8695(99)00027-4
  12. Robert, A. S., 1991, 'Practice for the Measurement of the Apparent Attenuation of Longitudinal Ultrasonic Waves by Immersion Method,' ASTM Section 3., Vol. 0303, E.E.664-78, pp. 263-265
  13. Kline, R. A., 1983, 'Measurement of Attenuation and Dispersion Using an Ultrasonic Spectroscopy Technique,' J. Acoust. Soc. Am., Vol. 76, No. 2, pp. 498-504 https://doi.org/10.1121/1.391591
  14. Ping, H., Jun, Z., 2001, 'Acoustic Dispersion and Attenuation Measurement Using both Transmitted and Reflected Pulses,' Ultrasonics., Vol. 39, pp. 27-32 https://doi.org/10.1016/S0041-624X(00)00037-8
  15. Badidi Bouda, A., 2003, 'Grain Size Influence on Ultrasonic Velocities and Attenuation,' NDT&E International., Vol. 36, pp.1-5 https://doi.org/10.1016/S0963-8695(02)00043-9
  16. Gross, B. and Srawley, J. E., 1966, 'Stress Intensity Factors by Boundary Collocation for Single Edge Notch Specimens Subject to Double Cantilever Beam Model for Studying Splitting Forces,' NASA Tech. Note, D-3295