• Title/Summary/Keyword: Assist device

Search Result 271, Processing Time 0.028 seconds

Implementation of The User-level Flash File System Based on Linux (리눅스 기반의 사용자 수준 플래시 파일 시스템의 구현)

  • Kwon, Woo-Il;Park, Hyun-Hui;Yang, Seung-Min
    • The KIPS Transactions:PartA
    • /
    • v.11A no.3
    • /
    • pp.139-148
    • /
    • 2004
  • The number of applications of small embedded systems such as PDAs, electronic note books, etc. based on Kinux, have increased. Due to the monolithic characteristic of Linux kernel, it is not suitable to satisfy the various kinds of embedded application requirement. To assist the shortcoming of monolithic kernel, we implement uJFFS 113th file system as an application program process which runs in user space. This solution consists of a file system and a flash device driver, and makes Linux kernel smaller by separating the file system from the kernel. uJFFS consists of ujffs_fs that plays a part of file system and ujffs_drv that controls a flash device. Which provides the same user interface as Linux does. A Device driver for the physical device is implemented in user pace, which prevents kernel failures from file system errors. So uJFFS can increase stability of the system.

Development of a Mouse for Alternative Computer Access Using Smart Device (스마트기기를 이용한 컴퓨터 대체접근 마우스 개발)

  • Jang, U.H.;Hong, W.K.;Kim, C.G.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2014
  • Almost of alternate computer access devices which assist people with disabilities to utilize the computer connected to computer by some cables or installed in as a S/W program. These devices have some spatial limitations to the people with disabilities, it can't guarantee the free and diverse access to the computer. For these reasons, in this paper, an Android-based mouse program for alternative computer access was developed. A people with physical disabilities who has some limitation of hand movements can use it in anywhere and anytime using only the fine motor skill of the upper limbs. The developed device recognizes the user's point touch and transforms it into the location of mouse cursor. The location information transferred to the computer via Bluetooth communication module equipped in smart devices. Also the group scanning method which can reduce the user's fatigue degree was employed and click, double click, drag & drop functions by hand's movements were equipped. The developed device will help the people with disabilities to use computer with brief touch and convenient operation without spatial limitation.

  • PDF

Mechanical Assessments Development of Through The EV-Relay's Impurse Prediciton (EV Relay의 충격량 예측을 통한 기계적 시험법 개발)

  • Kim, Eung-Nam;Park, Guk-Nam;Ryu, Hang-Su;Park, Hong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.868-869
    • /
    • 2011
  • Domestic Foreign automaker's are focused on the high-efficiency, low emission cars development. On the way, the hybrid car is the first priority. Hybrid electric vehicle battery pack configurations, EV Relay one of the key components of the engine driving, to assist in the drive motor to supply electrical energy to the battery is a device for opening and closing of the output device. EV Relay determine the longevity and the replacement cycle, The EV Relay environmental conditions and duty cycle considering the reliability tests are essential requirements of many automotive companies to respond to RFQ, this test is essential. This paper using Maxwell Software for Prediction of the Ev Relay impulse, the theoretical data to obtain the impulse to develop methods for mechanical testing after to take advantage of it.

  • PDF

A Clinical Experience of Korean Artificial Heart(AnyHeart) (한국형 인공심장(AnyHeart)의 임상경험)

  • Sun, Kyung;Son, Ho-Sung;Jung, Jae-Seung;Chung, Bong-Kyu;Lee, Sung-Ho;Shin, Jae-Seung;Kim, Kwang-Taik;Lee, Hye-Won;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.548-552
    • /
    • 2002
  • Korean artificial heart(AnyHeart) is a single-pieced and implantable hi-ventricular pulsaile pump adapting a moving actuator mechanism. The authors report a case of clinical application of AnyHeart as a life-saving device for the patients with end-stage heart disease combined with biventricular failure.

Enhancement of H.264/AVC Encoding Speed and Reduction of CPU Load through Parallel Programming Based on CUDA (CUDA 기반의 병렬 프로그래밍을 통한 H.264/AVC 부호화 속도 향상 및 CPU 부하 경감)

  • Jang, Eun-Been;Ha, Yun-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.858-863
    • /
    • 2010
  • In order to enhance encoding speed in dynamic image encoding using H.264/AVC, reducing the time for motion estimation which takes a large portion of the processing time is very important. An approach using graphics processing unit(GPU) as a coprocessor to assist the central processing unit(CPU) in computing massive data, will be a way to reduce the processing time. In this paper, we present an efficient block-level parallel algorithm for the motion estimation(ME) on a computer unified device architecture(CUDA) platform developed in general-purpose computation on GPU. Experiments are carried out to verify the effectiveness of the proposed algorithm.

Energetics of the Heart Model with the Ventricu1ar Assist Device

  • Chung, Chanil-Chung;Lee, Sang-Woo;Han, Dong-Chul;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 1996
  • We investigated the energistics of the physiological heart model by comparing predictive indexes of the myocardial oxygen consumption (MOC), such as tension-time index (R), tension-time or force-time inteual (FTI), rate-pressure product (RPP), pressure-work index, and systolic pressure-volume area (PVA) when using the electro-hydraulic left ventricular device (LVAD). We developed the model of LVAD incorporated the closed-loop cardiovascular system with a baroreceptor which can control heart rate and time-varying elastance of left and right ventricles. On considering the benefit of the LVAD, the effects of various operation modes, especially timing of assistance, were evaluated using this coupled computer model. Overall results of the computer simulation shows that our LVAD can unload the ischemic (less contractile) heart by decreasing the MU and increasing coronary flow. Because the pump ejection at the end diastolic phase of the natural heart may increase the afterload of the left ventricle, the control scheme of our LVAD must prohibit ejecting at this time. Since the increment of coronary flow is proportional to the peak aortic pressure after ventricle contraction, the LVAD must eject immediately following the closure of the aortic valve to increase oxygen availability.

  • PDF

Blood Compatibility of Hollow Fiber Membranes Treated by Plasma Polymerization (플라즈마 중합 처리된 중공사 막의 혈액 적합성)

  • Lee, Sam-Cheol;Kwon, O-Sung
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.233-240
    • /
    • 2005
  • Surface modification of polypropylene hollow fiber membranes was performed in order to develop blood-compatibility biomaterials for use in the blood contacting surfaces and oxygenation membranes of a lung assist device (LAD), important medical device even more useful. Blood compatibility of materials was determined by using anticoagulation blood and evaluating formation of blood clots on their surfaces as well as activation of plasma coagulation cascade, platelet adhesion, and aggregation. It was verified that the number of platelets on the silicone coated fibers was significantly lower than that on untreated fiber membrane, indicating improved blood compatibility. It was also found that the polypropylene hollow fiber membranes using plasma treatment exhibited suppression of complement activation in blood compatibility test.

A Study on the Direction of the Development of Hearable Devices for Seniors -Focusing on Wireless Earphones- (시니어를 위한 히어러블 디바이스 개발 방향성 연구 -무선 이어폰을 중심으로-)

  • Kijeong, Choi;Seunghee, Suh
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.135-152
    • /
    • 2022
  • This study aimed to evaluate the user experience of hearable devices for seniors and suggest possible development directions. A literature review, case study, and in-depth interviews were conducted. Based on the literature review, convenience, accessibility, transmissibility, wearability, aesthetics, and interest were determined as the user experience factors of hearable devices. Then, in-depth interviews were conducted with 12 participants aged 60 or older regarding four devices. Participants tried four different types of wireless earphones which were selected based on a case study: open-type, kernel-type, neckband-type, and earring-type. Regarding convenience, the participants preferred to carry small devices and regarding accessibility, participants responded positively for most product types. For transmissibility and wearability, there were differences depending on whether devices were put on correctly, but the participants preferred products that did not wholly block external sounds. For aesthetics, participants preferred small and cutting-edge designs. Interest was noticeable among those who had not used the devices before, and for stability, the neckband-type was the most preferred. Based on the results we suggest designing small cutting-edge designs and button-type assist devices, not blocking the external sound, providing a participation program, simplifying device functions, and establishing a method that can be combined with and stored in clothes and a delivery method that can signal danger.

Application Design and Implementation for Spinal Disorder Prevention using Kotlin (코틀린을 사용한 척추 질환 예방을 위한 Application 설계 및 구현)

  • Kyoung-Ju Minn
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.2
    • /
    • pp.71-77
    • /
    • 2024
  • The increasing use of smart devices in South Korea has led to a rise in patients with spinal disorders. This study aims to develop an Android application with exercise prompts to prevent spinal disorders, enhance the usability of healthcare applications, and utilize Android's overlay technology to encourage physical activity. Considering South Korea's total population, it is estimated that around one million individuals may suffer from spinal disorders due to smart device usage. Emphasizing the importance of maintaining proper posture and regular exercise habits, this research highlights the need for innovative application development to assist users in preventing musculoskeletal disorders caused by smart device usage.

Intensive management of acute right heart failure (급성 우심 부전의 집중 치료)

  • Kim, Gi Beom;Noh, Chung Il
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.11
    • /
    • pp.1041-1048
    • /
    • 2007
  • Not a few patients in children and adolescents are suffering from right ventricular (RV) dysfunction resulting from various conditions such as chronic lung disease, left ventricular dysfunction, pulmonary hypertension, or congenital heart defect. The RV is different from the left ventricle in terms of ventricular morphology, myocardial contractile pattern and special vulnerability to the pressure overload. Right ventricular failure (RVF) can be evaluated in terms of decreased RV contractility, RV volume overload, and/or RV pressure overload. The management for RVF starts from clear understanding of the pathophysiology of RVF. In addition to correction of the underlying disease, management of RVF per se is very important. Meticulous control of volume status, inotropic agents, vasopressors, and pulmonary selective vasodilators are the main tools in the management of RVF. The relative importance of each tool depends on the individual clinical status. Medical assist device and surgery can be considered selectively in case of refractory RVF to optimal medical treatment.