• Title/Summary/Keyword: Area ratio method

Search Result 1,944, Processing Time 0.029 seconds

A Study on Facades of Buildings - The window area ratio distribution of building facade in Tokyo - (건물파사드에 관한 실측조사 연구 - 일본 동경지역의 벽체의 창면적비를 중심으로 -)

  • Kim, Chong-Min;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.71-80
    • /
    • 2003
  • The purpose of this study is to analyze the window area ratio distribution of building facade in Tokyo metropolitan area. The survey was carried out in Marunouchi, Kanda, Kasai and Todoriki district. The results of this study were as follows; to propose of window area ratio production method, analyzed and surveyed window area ratio of each district building-used and to compared every wall window area ratio of building. Every wall window area ratio of office district is $20\sim40%$, ones of non-office district is 15% or 35%. Residential area results are every wall window area ratio of apartment is 35%, ones of a house is 15%. To increase of office building to appear that Kanda, Kasai added window area ratio. But, Marunouchi, Todoriki wad not this tendency. Above mentioned results are made out database.

Estimation of Forest Management Ratio under Article 3.4 of the Kyoto Protocol: A Case Study on the Chungcheongbuk-do (교토의정서 제3조 4항의 산림경영율 추정방안 및 사례분석 - 충청북도를 대상으로 -)

  • Kim, Hyungho;Kang, Hyeondeug;Kim, Rae Hyun;Kim, Cheol Min;Koh, Kwang Chul;Lee, Kyeong Hak
    • Journal of Korean Society of Forest Science
    • /
    • v.102 no.4
    • /
    • pp.608-616
    • /
    • 2013
  • The objective of this study was to suggest contingent valuation method, simple random sampling method, systematic sampling method, maximum practice area method, and overlay practice area method as the estimation methods for forest management area to estimate carbon dioxide sink by forest management as stated in Article 3.4 of the Kyoto Protocol. A case study for Chungcheongbuk-do was performed using maximum practice area method which was thought of as the most rational method within MRV(Measurable, reportable and verifiable). The forest management ratio was defined as forest management area over the total forest area. Based on the definition of forest management activity, forest area was divided into practice forest land and non-practice forest land. The area of forest mangement for practices was based on the 'National Forest Management Information System' and the history of practices from the 'Proposals on Private Management Information Database'. The area of forest management for non-practices was based on the public used forest land from 'Categorial map of forest land'. It was shown that the forest management area of Chuncheongbuk-do was 115,566 ha for practice forest land, and 131,008 ha for non-practice forest land. The forest managent ratio was 49.7% of the total forest area of 495,806 ha. This study made possible to the estimation of the forest management ratio under Kyoto Protocol, and had an advantage in searching for a practical method of forest management plan in which the forest management ratio could be enhanced.

An Experimental Study of the Variable Sonic/supersonic Ejector Systems (가변형 음속/초음속 이젝터 시스템에 관한 실험적 연구)

  • Lee Jun Hee;Kim Heuy Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.554-560
    • /
    • 2005
  • A new method to improve the efficiency of a hydrogen fuel cell system was introduced by using variable sonic/supersonic ejectors. To obtain the variable area ratio of the nozzle throat to ejector throat which controls the mass flow rate of the suction flow, the ejectors used a movable cylinder inserted into a conventional ejector-diffuser system. Experiments were carried out to understand the flow characteristics inside the variable ejector system. The secondary mass flow rates of subsonic and supersonic ejectors were examined by varying the operating pressure ratio and area ratio. The results showed that the variable sonic/supersonic ejectors could control the recirculation ratio by changing the throat area ratio, and also showed that the recirculation ratio increased fur the variable sonic ejector and decreased for the variable supersonic ejector, as the throat area ratio increases.

Studies on Damping Ratio of Nailed Joint Connecting Wall to Floor in Light Frame House (경골목조주택의 벽체-바닥체 못결합부의 감쇠비에 관한 연구)

  • Kim, Kwang-Mo;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.65-71
    • /
    • 1996
  • In the design of wood structures, the consideration of the dynamic load effect has been increased. Generally, damping ratio is presented as the method of considering dynamic load effect. So, the relationship between joint type and damping ratio was investigated. It has been known that the joint extremely damp the dynamic load in wood structures. Static test was performed to determine the effects of nail size and friction area on joint strength and stiffness. Joint strength and stiffness were increased with nail size. However, the static properties of joint was not affected by friction area. Cyclic test was performed to determine the effects of nail size, friction area and load magnitude on damping ratio, Damping ratio was affected by all factors. Increasing the width of the bottom plate was suggested as the most adequate method to increase the damping ratio without the reduction of the static properties of the structures.

  • PDF

Remote Sensing Application for the Mineralized Zone Using Landsat TM Data (LANSAT TM자료에 의한 광화대조사 응용기법개발)

  • 姜必鍾;智光薰;曺民肇;崔映燮;Choi, Young Sup
    • Korean Journal of Remote Sensing
    • /
    • v.2 no.2
    • /
    • pp.79-94
    • /
    • 1986
  • TM data, which have better resolution in spatial and spectral than MSS data, were used for this study, and several Image Processing Techniques (IPT) were examined for finding the best IPT to fit to lineament extraction and mineralized zone mapping. The Ryeongnam area was selected as test area, because the area is one of major mineralized zones in Korea and its hydrothermal alteration zone is wider and deeper than other areas. The spatial filtering method is most optimum one for limeament extraction: that is, the directional spatial filtering is most efficient to detect N-S, E-W direction lineaments on the image, and the high boost filtering can be applied for mapping all direction lineaments. The ratio method was selected for detecting altered zone. It is possible to make several tens combinations in ratio with 7 bands of TM data, but considering spectral characteristics of each band of TM to the geological meterials and vegetation, the band 4/band 3(A), band 5/band 7(B), and B/A ratio methods were chosen among them. The 5/7 ratio image did not show clearly the altered area due to noise from vegetation cover, so the 4/3 ratio imae was used for trying to decrease the effect of vegetation. As a result the B/A ratio image showed quite nicely the altered zone of the test area. In conclusion, the spatial filtering is the best image processing techniques for lineament mapping, and the B/A ratio image in TM data is useful for the mineralized zone mapping.

Variation of Stress Concentration Ratio with Area Replacement Ratio for SCP-Reinforced Soils under Quay Wall (치환율에 따른 안벽구조물 하부 SCP 복합지반의 응력분담비)

  • 김윤태
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2004
  • In order to accelerate the rate of consolidation settlement, to reduce settlement, and to increase bearing capacity for soft ground under quay, sand compaction pile method (SCP) has usually been applied. SCP-reinforced ground is composite soil which consists of the sand pile and the surrounding soft soil. One of main important considerations in design and analysis for SCP-reinforced soils is stress concentration ratio according to area replacement ratio. In this paper, the numerical analysis was conducted to investigate characteristics of stress concentration ratio in composite ground. It was found that stress concentration ratio of composite ground is not constant as well as depends on several factors such as area replacement ratio, depth of soft soil, and consolidation process. The values of stress concentration ratio increase during loading stage due to stress transfer of composite soil, and reach up to 2.5∼12 according to area replacement ratio at the end of construction. After the end of consolidation, however, these values are converged to 2.5 to 6.0 irrespective of area replacement ratio due to increase in effective stress of soft soil during consolidation process.

A Study on the Age Estimation Based upon Attrition of Molars (증령에 따른 구치의 학모면적비에 관한 연구)

  • 양무도;이승우
    • Journal of Oral Medicine and Pain
    • /
    • v.6 no.1
    • /
    • pp.91-100
    • /
    • 1981
  • The author collected 146 men's stone models and 175 women;s stone models over the age of twenties, and studied area ratio of attrition of molars. Area ratio of attrition = (area of attrition / area of occlusal surface)*100(%) All data were analyzed by means of statistical method, and following results were obtained. 1. There was correlation between age and area ratio of attrition, that is, area ratio of attrition was increased with aging process. 2. Regression equtions and coefficients of correlation showed a significant meaning. 3. Generally, upper teeth showed higher tendency of area ratio of attrition, being compared with lowers. 4. Being compared with male and female, there was no uniform difference.

  • PDF

A Numerical Analysis for the Influential Factors on the Stress Concentration Ratio (모래다짐말뚝지반의 응력분담비에 영향을 미치는 인자에 대한 해석적 연구)

  • Choi, Hyo-Won;Shin, Hyun-Young;Yoo, Han-Kyu;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.966-973
    • /
    • 2005
  • The stress concentration ratio in accordance with area replacement ratios were considered as core elements of design. However, the stress concentration ratio will be vary depends on progress of consolidation in clay ground. And, since it is not sure to know the affecting factors accurately, the value is decided based on field experiences. To use SCP method more effective and correspond to soil improvement, the decision on proper area replacement ratio through the exact stress concentration ratio is very important. Accordingly, a numerical analysis on influence of various factors that needed to make rational designing guide for decision of proper area replacement ratio to stress concentration ratio was executed in this study.

  • PDF

Studies on the Evaluation Method of Heavy Metal Contamination Degree in the Han River (한강 저질중의 중금속 오염도 평가 방법에 관한 연구)

  • 어수미;박성배
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.47-57
    • /
    • 1992
  • This study was performed to evaluate contamination degree of heavy metals in sediments of Han River, compared with other nation's evaluation method. The results were as follows 1. The contamination Ratio calculation method by heavy metal concentration in differnt fraction size has a limitation to apply to all of the areas of Han river because of its characteristics of sediment. As a result, this method applied to only 4 areas of Pal Dang, Wang Sook Chon, Uk Chon, and Bul Kwang Chon, and Contmination Ratio of heavy metals in those areas were relatively low of below 3. So it's considered that those areas have less contaminated from anthropogenic contaminants. 2. The Contamination Ratio calculation method by heavy metal concentration in different areasthat of upper area to be background level-has a limitation also to apply to Han river. But it is considered that this method was relatively suitable to apply, so it should be prepared evaluation standand method for them. Contamination ratio from background level as Pal Dang area were most high in An Yang Chon. So it must be prepared purification and control measure at An Yang Chon.

  • PDF

A Study on the Shear Strength Characteristics of Composited Ground applying RAP Method by Large Direct Shear Test (대형직접전단시험에 의한 RAP 복합지반의 전단강도 특성 연구)

  • Chun, Byung-Sik;Seo, Deok-Dong;Kim, Jong-San
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.82-89
    • /
    • 2004
  • To secure stability and availability of Rammed Aggregate Pier method as the foundation of a structure, the shear strength characteristics according to the area replacement ratio of RAP and the relative density of in-situ ground was studied through soil laboratory tests and large direct shear tests in a model ground. As a result, the internal friction angle tends to increase in proportion to in-situ relative density(Very Loose, Loose, Medium) in composite ground formed by the same area replacement ratio of RAP and also increase in proportion to increasing the area replacement ratio(30, 40, 50%) of RAP in the same ground condition. Furthermore, the comparative analysis between the experimental value and theoretical value of the shear strength is carried out.

  • PDF