• Title/Summary/Keyword: Apartment Supply

Search Result 322, Processing Time 0.023 seconds

A Study on Impact Sound Performance accoring to Variation of Floor Construction Method in Apartment Building (공동주택 바닥의 구법 변화에 따른 충격음 차단성능에 관한 연구)

  • Kim, Sun-man;Jee, Nam-Yong;Kim, Jae-Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.97-101
    • /
    • 2003
  • Currently, it is increasing the importance of floor impact sound performance in apartment building due to users' various needs for comfortable residential environments. However, there are little date on floor impact sound performance because Korean apartment building floor is an ON-DOL which is made of several elements. In this study, floor impact sound performance according to variation of floor construction method were investigated. And based on these investigated results, datas can be used to supply constructor and comsumer basis data to estimate floor impact sound performance.

  • PDF

A Basic Study on the Solution of Maintenance Problems for the Improvement Residential Satisfaction in Apartment House (거주자 중심의 공동주택 주거만족도 향상을 위한 유지관리 문제점 개선방안에 관한 기초연구)

  • Jung, Jung-hee;Byun, Jeong-Yoon;Seo, Hee-Chang;Kim, Ju-Hyung;Kim, Jae-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.345-346
    • /
    • 2012
  • The Korean construction market and housing policy have been increasingly focusing on supplier. As opposed to houses in private areas, Apartment House using the common infrastructure such as elevators, electrical facilities, heating system and hot water supply system need joint management. Their management usually depends on the resident cooperation or outsourcing. On this study, I investigated the level of satisfaction of Apartment House residents and its managing personnel, the conditions of its management, and analysed the important factors which influence the degree of residence satisfaction with respect to its maintenance and management.

  • PDF

A Study on Impact Sound Performance according to Variation of Floor Construction Method in Apartment Building (공동주택 바닥의 구법 변화에 따른 충격음 차단성능에 관한 연구)

  • 김순만;지남용;김재훈
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.97-101
    • /
    • 2003
  • Currently, it is increasing the importance of floor impact sound performance in apartment building due to users' various needs for comfortable residential environments. However, there are little data on floor impact sound performance because Korean apartment building floor is an ON-DOL which is made of several elements. In this study, floor impact sound performance according to variation of floor construction method were investigated. And based on these investigated results, datas can be used to supply constructor and comsumer basis data to estimate floor impact sound performance

  • PDF

Development of a Method of Pre-Feasibility Study for the Application of Co-Generation System in New Apartment (신설아파트 열병합발전 도입에 대한 예비 타당성 분석기법 개발)

  • Kee, Woo-Bong;Kim, Kwang-Ho
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.185-193
    • /
    • 2007
  • The object of this study is the development of a Method which is enable to review the preliminary feasibility for co-generation system in new apartment buildings. In Korea co-generation systems have been installed in most of large industrial plants and commercial buildings which consume a large quantity of electric and heat energy, for energy saving and cutting products cost, under positive governmental supports. However for apartment buildings which consume quite a large electric and heat energy, are still remained in conventional energy supply system, and are not popular to utilize useful co-generation system. One of the major reason for these is the lack of clear and easy justification tool. In this circumstance, this study can provide a tool to verify the feasibility of co-generation in apartment buildings with this handy tools for planners and designers beforehand.

  • PDF

A Study on the Policy Agenda for Activating PC Apartment using Focus Group Interview(FGI) (FGI를 사용한 PC공동주택 활성화 정책과제 모색)

  • Bae, Byung-Yun;Kang, Tai-Kyung;Shin, Eun-Young;Kim, Kyong-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.888-895
    • /
    • 2020
  • In the construction industry, off-site construction (OSC) is drawing attention as a production method due to changes in working hours and the supply and demand of manpower. In 1991, there was a policy of spreading and expanding the use of precast concrete (PC) apartment homes, but they have not been actively used so far since they were discontinued due to quality problems. In this study, policy tasks were analyzed to motivate the application of OSC-based PCs in the apartment housing sector, and policy directions were derived by conducting focus group interviews (FGI). Nine policies are suggested regarding the following topics: PC apartment supply quantity provision, priority application of public housing, priority supply of public housing, preferential floor area ratio, funding, tax support, improvement of business area structure, improvement of delivery method, factory certification system, and training of experts. The results of the FGIs are as follows. First, in order to revitalize PC apartment homes, leading efforts from the public sector are required. Second, rather than reorganizing the business sector or introducing a new delivery method, a policy direction that induces the strengthening of cooperation is desirable. Third, PC activation should be promoted on an institutional basis for securing appropriate construction costs and quality.

A Study on Improved Operation of Apartment Heating System in a Machine Room (공동주택 기계실 난방설비 운전 개선 연구)

  • Seo, Jeong-Ah;Shin, Younggy;Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • This study proposes an idea for energy saving in apartment machine rooms. A conventional district heating system is equipped with constant-flow pumps and bypass valves to regulate pump differential pressure. Each family unit is equipped with a constant-flow on/off valve. This leads to excessive hot water circulation and a high return temperature. To reduce energy loss, this study assumes that each family unit is renovated with a heating valve which regulates the return temperature at $35^{\circ}C$. The hot water supply pump is also replaced with a pump with an inverter to vary flow rate. Expected energy savings is then estimated from field test data. According to the results, pump electricity consumption was reduced by 6,100 kWh for a family unit building over about half a year. The supply temperature can also be lowered by $5^{\circ}C$, which can contribute to a production of electricity of 10.3 kWh/ton of hot water.

A Study on the Estimation model of the Amount of the Electric Energy Consumption according to the Apartment Heating Type (공동주택 난방방식별 전력에너지 소비량 추정모델 작성 연구)

  • Lee, Kang-Hee;Yang, Jae-Hyuk;Ryu, U-Sang
    • KIEAE Journal
    • /
    • v.10 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • Electric energy is indispensible of the development of the industrial and living sector. Among the energy sectors, the building area shares 20% of the produced electric power in Korea. As we plan to supply the apartment, we need to forecast the required amount of the electric energy and supply the infrastructure to apartment for the lighting, cooling. Nonetheless, it is not easy to forecast the required amount of the electric energy, considering the management aspect, building physical aspect and social-geographic aspect. In this paper, it studied the estimation model of the electric energy, reflecting the affecting variables such as total area, number of household, geography and so on. The estimation model is proposed in 3-types which explained in central heating, individual heating and district heating, and each type have two estimation model, reflecting the affecting variable and corelation between variables to eliminate the muticolinearity. The unit of electric energy consumption per area and year is similar in three heating type and the results are as follows; the central heating is $34.446kWh/yr{\cdot}m^2$, individual type is $35.756446kWh/yr{\cdot}m^2$ and district heating is $34.285446kWh/yr{\cdot}m^2$.

Balcony window style photo-voltaic(PV) system design by considering resident's residential time rate - Focus on the design of apartment building balcony window PV system and it's performance - (거주자 주택 점유율을 고려한 공동주택 발코니 PV시스템 디자인 - 공동주택의 발코니 PV시스템 디자인과 성능검증 중심으로 -)

  • Chin, Kyung-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • In case of general residential house, photovoltaic can be installed at roof, wall, and any other places. But, in case of apartment building, there has not enough roof space to install photovoltaic panels to supply enough electricity. Actually, apartment building roof and facade wall (exclude the balcony window space) is not enough space to produce and supply the electricity to residents by installing PV panel. Generally, the space of facade balcony with windows in facade wall at apartment building occupied about $70{\sim}80%$, in all facade space. So, if we could use the balcony and windows space in facade as PV to generating electricity, there could contribute the energy saying. But, PV cell is opacify. So if it installed at front window area in apartment building, residents may have displeasure for that opacity character. But the other hand, residents are not always in house especially in day time that is exactly good time for generating electricity by PV. If we can use PV at the facade balcony with window without collusion of resident's displeasure, there have good attraction to using sustainable energy. Hence, this study suggests the design of facade balcony window style PV by considering resident's living pattern in apartment building. The methods of this study are as follows. At first, this study surveyed to the residents about residential time in their home and asked user demand by Delphi survey. At second, this study designed balcony open style PV system which oriented to the user demand. At third, this study tests designed result performance by computer simulation that compared design result with old design. As a result, For the purpose of satisfying the resident demand, there designed sliding window style which slide the several door systems to the one side. That would be make balcony absolute open scenery to the residents. Hence, the designed system performance results were as follows. When we compare the small apartment and large apartment, smaller one has good performance than larger one. Because resident's residential time characteristic. And that has more good electronic performance than vertical style that is similar to roof style.

A Study on the Qualification System for Raising Engineers of Maintenance for Apartment Houses - Based on the Qualification System of the United States - (공동주택 유지관리전문인력 육성을 위한 자격체계에 관한 연구 - 미국의 자격체계를 중심으로 -)

  • Park, Sang Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.1
    • /
    • pp.169-179
    • /
    • 2011
  • Korea owns vast amount of apartment houses no less than those of world prominent countries, but did not pay enough efforts to maintain existing apartment houses and develop policies to reuse them due to growth driven policy of housing supply like construction of new houses. Korea constructed tremendous amount of houses in short period through government led forced house supplying policy, and resulted in excess houses such that present house supply rate happened to be reaching 110%. However, recently there are growing demand of change in housing policy due to social environmental changes like low birth rate and aging of society etc and nationals' demand for improvement of residential quality. When such social changes are demanded and 80% of apartment houses in Korea are less than 20 years old, renovations and remodeling of apartment houses are anticipated to emerge as important matter. In particular, the apartment houses in Seoul and the 1st generation new cities like Bundang and Ilsan etc have passed considerable period of time after construction and require safety measure, it is quite impending to raise engineers for the maintenance of existing apartment houses. Therefore, in this paper, direction for the raising of maintenance engineers in Korea was proposed through analysis of relevant qualification system for the apartment houses maintenance engineers in the U.S.

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심(都心) 임대(賃貸)아파트의 에너지 및 상수(上水) 소비(消費) 특성(特性) 분석(分析))

  • Seo, Youn-Kyu;Kim, Joo-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.11a
    • /
    • pp.261-265
    • /
    • 2008
  • To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072m^2$ per year and they used $604.2MJ/m^2$ Typical energy consumption unit on $74.4m^2$ of area and $448.8MJ/m^2$ on $105.8m^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an Typical energy consumption unit standard through this research, apartments should use energy more efficiently.

  • PDF