• Title/Summary/Keyword: Apartment Supply

Search Result 322, Processing Time 0.022 seconds

Research on the Actual Condition of Risk of Remodeling Project (리모델링사업 리스크 실태조사 연구)

  • Lee, Teck-Wn
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.3
    • /
    • pp.215-222
    • /
    • 2003
  • When constructing buildings, planning, design, construction, using & maintenance as building life cycle. Due to industrialization in 1960s and development of new town from the late 1980s to the early 1990s, Korean housing supply rate reaches almost 100%. After construction companies confronted limit of new building construction, they recognized remodeling as a part of construction, and organized remodeling team or FM team to improve sustainable industrial area. However, since companies in Korea are lack of experience and research activities for remodeling, it makes obstacle to improvement of remodeling business. So the objective of this study is to help carry out remodeling business by suggesting the counterplan through investigation of a risk of apartment remodeling business.

  • PDF

A Study Regarding the Recognition and Use Actual Condition about the Western Style Furniture (입식가구에 관한 사용자 인식 및 이용실태에 관한 연구)

  • Yim, Jong-Hun;Kim, Kyung-Sook
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.11a
    • /
    • pp.86-90
    • /
    • 2006
  • Through this study, I conducted surveys on apartments with western style furniture to investigate perception on the western style furniture and its use. For the subject of survey, I selected three apartment complexes at Suji-gu, Yongin city which has been recently developed as a new town. Out of total 150 copies of survey sheets 142 fully answered copies were adopted as a final analysis data. Considering supply rate and application, sofa and chair of dining table were chosen to refer as western style furniture. As a result, most of the respondents had inconvenience in using western style furniture. Further study on side effects of adopting western style furniture should be followed.

  • PDF

A Study on the Effect of Brand Value Through Residential Satisfaction for CRM of Home Builders (주택건설업체의 CRM에 의한 주거만족도가 브랜드가치에 미치는 영향)

  • Jung, Suk Hwang;Chang, Seog Ju
    • Journal of Korean Society for Quality Management
    • /
    • v.44 no.2
    • /
    • pp.425-450
    • /
    • 2016
  • Purpose: This study can provide a strategic advantage for the marketing information of CRM of apartment provider microscopically. It is also expected to contribute to policy for public housing supply in the macro. Methods: This study is contained theoretical research on CRM & Residential Satisfaction & the brand of Apartments with the search for prior literature. Establish a research model to derive a hypothesis. It performs measurements aimed at an apartment tenant. After the test the hypothesis proposes a conclusion. Results: CRM activity of the housing construction companies is confirmed that a significant positive influence on residential satisfaction and brand value. Conclusion: Housing construction companies through improved residential satisfaction have on the growth strategy that takes the brand value in regardless of environmental factors. it is necessary to focus on CRM activities.

A Study on the Characteristic of the Thermal Environment in the Cooling System at the Apartment (공동주택 거실의 냉방방식에 따른 열환경 특성에 관한 연구)

  • 이무진
    • Journal of the Korean housing association
    • /
    • v.10 no.4
    • /
    • pp.111-120
    • /
    • 1999
  • The purpose of this study is to evaluate the efficiency of the thermal environment created by the cooling system at the apartment that combines the forced convection cooling(the system reducing humidity from room) with the floor cooling radiation which uses the floor panel from floor heating system, a general residential heating system in Korea. In this study, the combined cooling system in which air supply, spurt temperature difference and interior draft are reduced, is compared with the existing forced convection cooling system. To identify the effect of the comparison concretely, a comparative experiment is carried out on tour conditions, ie, convection cooling, floor radiation convection cooling and floor radiation cooling. Through it the characteristical thermal environment formed within the model room is analyzed, and the conveying system of compressed floor chill and condensation problem are reviewed.

  • PDF

A Post Occupancy Evaluation by the Rental Apartment tenants of National housing Size (국민주택규모 임대아파트 임차자의 거주 후 평가)

  • Lee, Sang-Un;Park, Kyoung-Ok
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.289-294
    • /
    • 2003
  • Purpose of this study is to supply data that need in qualitative improvement and plan for middle class through a post occupancy evaluation by the tenants in the rental apartment of national housing size. The results of this study are as follows; 1) Characteristic of household differ as the size tenants live in at present. But, usually characteristic of household was family life cycle was from child-rearing time to secondary education time, a family's number was 3${\sim}$4 person, and income per month was 1${\sim}$3 million won. 2) The satisfaction of whole and physical environment were satisfied more than average 3 points. However, the satisfaction of economic performance and administration environment were dissatisfied by average 3 points low. 3) Factors that affect in housing satisfaction were administration environment, the housing size, a family's number.

  • PDF

Improving the Thermal Environment of Balcony in Apartment House (공동주택 발코니의 열환경 향상방안)

  • Park, Sun-Hyo;Bae, Sang-Hanw;Hong, Cheon-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.41-46
    • /
    • 2003
  • In recent days, it is usual case to extend the dwelling area to the balcony which is provided by service area. But the use of the extended area can be arisen discomfort with a view point of thermal environment by excessive heat accumulation in summer and excessive cold draft in winter. In this study, the skills were reviewed to improve the thermal environment of the extended area and evaluations were carried out. Additional heat supply by heat-convector installed at the lower end of the curtain wall can improve the thermal environment of the extended area and also arise surface temperature of the curtain wall surface. And aluminum plate installed under the floor could not improve the thermal environment but it was effective to shortening the initial heating time.

  • PDF

A Study on Ventilation Effectiveness Characteristics in a Apartment Housing (공동주택에서 환기효율 특성에 관한 수치적 연구)

  • Cha, Kwang-Suk;Lee, Dae-Woo;Yeom, Dong-Suk;Park, Myung-Sig
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.39-44
    • /
    • 2005
  • Recently according to the fashion of well-being, it is increasing that heat recovery ventilator is applied to the apartment housing, But the uniform locations of inlet and outlet in each room may provide better indoor air quality than ununiform locations of inlet and outlet. Proper design of air supply system requires information concerning the gas concentration difference between the ventilation effectiveness at the breathing line. This paper presents models to predict the gas concentration difference and the ventilation effectiveness, based on the two cases with proper number of outlets. As one of the results it is desirable to set the outlet location near the furniture which produce the contamination gas so much.

  • PDF

Simulation of Heat Supply Control of Continuous Heating System of Multistoried Apartment in Consideration of Radiation Heat Transfer (복사열전달을 고려한 고층아파트 연속난방 열공급제어 시뮬레이션)

  • Choi, Y.D.;Hong, J.K.;Yoon, J.H.;Lee, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.78-92
    • /
    • 1994
  • Thermal performance of pipe network of continuous heating system controlled by thermostat and flow control valve was simulated in consideration of radiation heat transfer and solved by linear analysis method. Thermal performance of real apartment building with radiant floor heating system was simulated by equivalence heat resistance-capacity method. This method enables to simulate the unsteady variation of temperature or each element of building. Heat transfer characteristics of each element were also investigated.

  • PDF

Experimental Study on the Effect of Ventilation System on Indoor Air Quality in New Apartment Buildings (신축 공동주택에서의 강제환기장치 사용에 따른 실내공기질 개선효과 실증연구)

  • Lee, Gyu-Dong;Park, Young-Sok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.143-146
    • /
    • 2006
  • There has been growing concern regarding IAQ(Indoor Air Quality) recently, and IAQ problems from the air-tightness and use of chemical materials addition to the building materials have become increasingly important factors in the built environment. Ventilation is supposed as the solution of healthy indoor quality, and Korea government requests that all new apartment buildings must have a ventilation system as a matter of duty since January, 2006. The purpose of this study is to investigate the indoor concentration change of VOCs include the Formaldehyde according to many different ventilation supply types. Results showed that the reduction effect of target pollutants by the ventilation system was very slight. The cause of these results was attribute to increase the emission rate of building materials by increasing the ventilation rate.

  • PDF

A Study on the Analyses of Defect Occurrences and its Repair Costs in the Public Equipment of an Deteriorated Apartment House (노후 아파트 공용설비부문의 하자발생과 보수비용 분석에 관한 연구)

  • 전규엽;조극래;홍원화
    • Journal of the Korean housing association
    • /
    • v.14 no.4
    • /
    • pp.11-19
    • /
    • 2003
  • This study intends to predict prospective defects and establish the plan of Preventive Maintenance through research and analysis of defect occurrences and their repair costs in the public equipment of ‘H’ apartment house from 1998 to 2001. According to results of the analysis, more than 90% of defects and their repair costs for 4 years of the building have occurred in heating, hot water and water supply equipments. In case of specific classification in each equipment, more than 60% of defects were found at hot water pipes and heating pipes, and their repair costs covered more than 60% of the total defect costs. After two repairs by ‘Preventive Maintenance’ had been performed in the year 1998, total defects and defects of each equipment each yew have increased in number from 1999 to 2001. But total repair costs and repair costs of each equipment have not increased as time has gone by, because repair costs have relationship with the price of materials and labor, the part of defect and the scale of repair.