• Title/Summary/Keyword: Anderson sampler

Search Result 27, Processing Time 0.019 seconds

A Study on the Size Distribution of Suspended Particulate in Broiler Houses (육용계사내 부유먼지의 입도 분포에 관한 연구)

  • 김종오;용준환
    • Korean Journal of Poultry Science
    • /
    • v.20 no.1
    • /
    • pp.11-15
    • /
    • 1993
  • Environmental measurements were made in 10 broiler confinement houses in order to characterize dust contaminants. Particles were collected by filters on nine stages Anderson Air Sampler, The obtained results were summarized as follows ; 1. The concentrations of the total suspended particles(TSP) were 7.584 mg/$m_3$~11.589mg/$m_3$ in 10 day old broiler houses and 15.836 mg/$m_3$~22.471 mg/$m_3$ in 30 day old broiler houses. 2. The concentrations of the coarse particles were 4.974 mg/$m_3$~18.981 mg/$m_3$ in 10 broiler confinement houses. Therefore, it was found that the coarse particles contributed to TSP between 65.6% and 85.0%. 3. The dust levels were higher in 30 day old broiler houses with TSP averaging about 19.341 mg/$m_3$ than 9.491 mg/$m_3$ in 10 day old broiler houses. In view of the above results , It was concluded that domestic broiler houses need artificial ventilation system.

  • PDF

The Study on Secondary Pollutants of $PM_{10}$ in Pocheon (포천지역에서 측정한 $PM_{10}$중 2차 생성입자에 관한 연구)

  • Park Tae-Sool
    • Journal of environmental and Sanitary engineering
    • /
    • v.20 no.4 s.58
    • /
    • pp.9-20
    • /
    • 2005
  • The purpose of the study was characteristics of secondary pollutants of $PM_{10}$ collected in pocheon between August 2002 and June 2003. The ambient concentrations of $PM_{10}$ mass, 9 water-soluble anions and cations, and 13 bulk composition trace elements were determined from filter samples collected by $PM_{10}$ high volume air sampler(UV-15H, Graseby-Anderson Co., USA). During this period average $PM_{10}$ mass concentration was $83.8{\mu}g/m^3(49.8{\mu}g/m^3\~111.6{\mu}g/m^3)$ in Pocheon. Mechanism for transformation of secondary pollutants by soluble ion components is divided into two categories; $NaNO_3$ type by the reaction of sea salt and $HNO_3$ in the atmosphere, and nitrate salt or phosphate salt type such as $(NH_4)_2SO_4,\;NH_4NaSO_4,\;and\;(NH_4)_2SO_4(2NH_4O_3)$.

Characterization of Size distribution of Anion Species in Atmospheric Aerosols (대기에어로졸중 음이온성분에 대한 입경분포의 변화특성)

  • 최금찬;박정호;임경택
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.124-129
    • /
    • 1994
  • Aerosol size distribution was determined using Anderson sampler for the anions( sulfate nitrate and chloride ) and TSP. Ionic species concentration and size distribution have been investigated in the daytime and nightime individually. Size classified samples were extracted with distilled water and analyzed for C $l^{[-10]}$ , N $O_3$$^{[-10]}$ and S $O_4$$^{2-}$, by ion chromatography. The size distribution of these ions and TSP was analyzed to investigate the seasonal and diurnal variation of concentrations as follows: (1)Size distribution of TSP showed bi- modal type in the daytime, but indicated tri-mode distribution in the nightime without any seasonal variation. (2)Sulfate concentrations were higher in fine- mode both in the daytime and nightime but fraction of sulfate was higher in coarse-mode during the Yellow Sand Period. (3)Nitrate and Chloride ions are dominant in fine-mode in winter while dominant in coarse-mode in the summer.

  • PDF

Characteristics of domestic coals and efficient control of coal dust (국내 석탄광 분진의 특성과 효율적 제어)

  • Kim, Soo Hong;Kwon, Jun Wook;Kim, Sun Myung;Kim, Yun kwang;Jang, Yun Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.4
    • /
    • pp.589-609
    • /
    • 2017
  • This study carried out the density and energy dispersive X-ray spectroscopy and particle size analysis which are the physical characteristics of coal dust by collecting samples of coal dust in the five domestic mines to control the coal dust through ventilation in the workplace for coal mining in the country. This will contribute to a more comfortable working environment by understanding the physical characteristics of the coal dust which is derived from any hard coal produced domestically. In particular, the result of PSA analysis showed that the size of coal dust sample for this study ranged from $0.007{\sim}88.614{\mu}m$ were the particles less than $3.5{\mu}m$, the size range responsible for pneumoconiosis. To observe the flow of coal dust collected on the wind speed, the fallout of coal dust produced by the wind tunnel for the wind was measured and the particle size analysis of coal dust fallout was carried out. In addition, airborne dust is measured according to the mine velocity by using a multi-stage Anderson sampler in the mine where fine dust is generated in a large amount and the wind speed is found out to control the coal dust below $3.5{\mu}m$. In addition, natural ventilation pressure of A mine was calculated to prevent over design of the main fan.

Daily Concentration Measurements of Water-soluble Inorganic Ions in the Atmospheric Fine Particulate for Respiratory Deposition Region (호흡기 침착부위에 따른 미세먼지 중 수용성 이온성분의 일별 농도 측정)

  • Kang, Gong-Unn;Lee, Sang-Bok
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.387-397
    • /
    • 2005
  • In oder to understand the deposition possibility of water-soluble inorganic ions in the atmospheric fine particulates for the human respiratory tract, the mass size distribution of ion species was measured using an Anderson sampler in the Iksan during fall, 2004. Samples were analyzed for major water-soluble ions using Dionex DX-100 ion chromatograph. The size distribution of water-soluble inorganic ions in the atmospheric particulates appeared bimodal distribution, which were divided around $1-2{\mu}m$ into two groups. Mass site distribution of total ion in the coarse mode was found to be almost similar level during the sampling period, but fluctuations of mass size distribution in the fine mode were observed. Considering the mass size distribution of total ion concentrations for the respiratory deposition region, it was found that about 77.1% of total tons could be deposited in the alveolar region, and which dominated the daily variation of total ion concentrations. The concentration of total ions, which could be deposited in both the head region and the tracheobronchial region, was $3.95{\mu}g/m^3$, whereas that in the alveolar rerion was $13.28{\mu}g/m^3$. Dominant ions which could be deposited in the alveolar region were ${NO_3}{^-},\;{SO_4}^{2-}\;and\;{NH_4{^+}$, accounting for about 40%, 27% and 22% of the total ions, respectively. Although $K^+$ was approximately 3% of total ions, it was shown that most of this could be deposited in the alveolar region due to its high fraction of small size distribution originated from anthropogenic source of biomass burning. The presence of these ions in the fine mode may be of public health significance as they are very biologically harmful to health and have a high probability of being deposited in human lung tissue.

Particle Size Distribution of Suspended Particulates in the Atmosphere of a Seoul Residential Area (한 도시 분진의 유해성 입도 분포에 대한 조사 연구)

  • Han, Eui-Jung;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.19 no.1 s.19
    • /
    • pp.130-136
    • /
    • 1986
  • The particle size of suspended particulates was measured by a Anderson air sampler from Mar. 1982 to Feb. 1984 in a part of Seoul. It was concluded as follows : 1) The arithmetic concentration of suspended particulates was $147.8{\mu}g/m^3$ in Spring, 136.9 in Summer, 131.9 in Autumn and 158.1 in Winter respectively. 2) The cumulative distribution of suspended particulates size in logarithmic diagram showed similar to normal log distribution. 3) The atmospheric particulate matters showed a bimodal size distribution on the base of unit particle concentrations, which divided at approximately $2{\mu}m$ in the diameter. 4) While the fine particulates less than $2.1{\mu}m\;was\;35.4{\sim}45.0%$, the coarse particulates was $55.0{\sim}64.5%$. 5) The higher the concentration of suspended particulates, the more increased the ratio of fine particulates. The higher the concentration of suspended particulates, the lower median size of suspended particulate as well. 6) The respirable dust particulates less than $4.7{\mu}m\;was\;52.2{\sim}62.9%$ in seasonal average through the 2 year samples. With the above result, air pollution concerned with public health could be evaluated and the control measures also are suggested.

  • PDF

Analysis of Variation in Total Airborne Bacteria Concentration to Assess the Performance of Biological Safety Cabinets in Microbial Laboratories

  • Hwang, Sung Ho;Park, Hyun Hee;Yoon, Chung Sik
    • Safety and Health at Work
    • /
    • v.5 no.1
    • /
    • pp.23-26
    • /
    • 2014
  • Background: The purpose of this study was to compare the concentration of total airborne bacteria (TAB) in biosafety cabinets (BSCs) at universities and hospital microbial laboratories to assess the performance of BSCs. Methods: TAB was determined by using the single-stage Anderson sampler (BioStage Viable Cascade Impactor). The samples were obtained three times (with the BSC turned off and the shield open; with the BSC turned off and the shield closed; and with the BSC tuned on and operating) from the areas in front of 11 BSCs. Results: TAB concentrations of accredited and nonaccredited BSCs were determined. No significant differences were observed in the TAB concentrations of the accredited BSCs and the nonaccredited BSCs for the areas outside the BSCs in the laboratories (p > 0.05). TAB concentrations for the BSCs sampled with the shield open and the instrument turned off showed differences based on the sampling site outside the BSC in each laboratory. Conclusion: These results imply that TAB concentration is not altered by the performance of the BSCs or TAB itself and/or concentration of TAB outside the BSC is not a good index of BSC performance.

Characteristics of PM10, VOCs and Aldehydes Levels in Nail and Hair Shops (네일샵미용실의 실내공기 중 미세먼지(PM10), 휘발성 유기화합물 (VOCs), 알데하이드류(Aldehydes)의 농도 및 업소 특성에 따른 상관성 분석)

  • Lee, Boram;Kuag, Sooyoung;Yang, Wonho;Jun, Sang il;Kim, Jung-su;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.6
    • /
    • pp.509-515
    • /
    • 2017
  • Objectives: The purpose of this study was to assess the indoor levels of $PM_{10}$, VOCs and aldehydes in nail shop and hair salon. Methods: The field survey was conducted for 52 hair salons 52 nail shops, and 26 shop-in-shops in Seoul and Daegu city. The field technicians investigated characteristics of each shop including operating time, indoor volume, ventilation and so on. Indoor concentrations of $PM_{10}$, VOCs and aldehydes, indoor temperature and humidity were measured in 12 hair salons, 12 nail shops and 6 shop-in shops. MP Surveryor II (Graywolf, USA) was used to measure $CO_2$ concentration, temperature and humidity for 8 hours. $PM_{10}$ concentrations were measured by minivolume air sampler with Teflon quartz filter ($0.2{\mu}m$ pore size, ${\varphi}$ 47 mm, Graseby-Anderson TEF-DISKTM) for 6 hours. VOCs passive sampler (OVM 3500) was used to collect VOCs for 8 hours and analyzed by GC/MSD. Results: The $CO_2$ concentrations were $759.4{\pm}58.2$ ppm in nail shops, $731.0{\pm}72.5$ ppm in hair salons, and $656.4{\pm}31.2$ ppm in shop-in-shops. The $PM_{10}$ concentrations were $27.5{\pm}14.2{\mu}g/m^3$ in nail shops, $33.1{\pm}6.3{\mu}g/m^3$ in hair salons, and $39.0{\pm}26.9{\mu}g/m^3$ in shop-in-shops. TVOCs concentrations were $3085.4{\pm}1667.8{\mu}g/m^3$ in nail shops, $2131.1{\pm}617.3{\mu}g/m^3$ in hair salons, and $1550.3{\pm}529.0{\mu}g/m^3$ in shop-in-shops. TVOCs concentrations in nail shops were significantly higher than those in hair salons and shop-in-shops (p=0.002). Formaldehyde concentrations were $60.8{\pm}36.6{\mu}g/m^3$ in nail shops, $89.1{\pm}55.4{\mu}g/m^3$ in hair salons, and $45.1{\pm}22.5{\mu}g/m^3$ in shop-in-shops. Conclusion: TVOCs concentrations in nail shop were the highest among others. TVOC concentrations in all stores exceeded indoor air quality stand of indoor air quality control in public-use facilities, etc act.

A Pilot Study on the Assessment of Bioaerosols in Restaurants (음식점의 공기 중 부유미생물 분포 평가를 위한 기초연구)

  • Kim, Jong-Gyu;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.2
    • /
    • pp.133-140
    • /
    • 2016
  • Objectives: A pilot study was undertaken to assess the bioaerosol levels in restaurants and determine the effects of variations in temperature, relative humidity, and air movement on these levels. It focused on the differences between kitchens and dining areas, as well as between summer and winter. Methods: A field survey was performed in six restaurants. An Anderson type air sampler was used for sampling bioaerosols, such as total suspended bacteria (TSB), Gram-negative bacteria (GNB), Gram positive bacteria (GPB), opportunistic bacteria (OP), Staphylococcus spp., and total suspended fungi (TSF). Results: The average levels of TSB were $1{\times}10^2CFU/m^3$ and of TSF they were $1{\times}10^0{\sim}10^1CFU/m^3$. The kitchens had higher bioaerosol levels compared to dining areas, and summer showed much higher levels than winter. The concentration of OP in summer was more than six-fold that of winter. S. aureus was detected both in kitchens and dining areas, even in winter. The main effect of air movement on TSB levels was significant (p<0.05), as was air temperature, relative humidity and air movement on TSF levels (p<0.05). Conclusion: There was a wide variation in bioaerosol levels among different restaurants. The results indicate that cooking foods may be a key factor affecting bioaerosol levels. The effects of air temperature and relative humidity reveal that bioaerosol levels may vary according to the season. The observation of pathogenic bacteria suggests that the hygiene management of establishments should be improved. Future research is needed to characterize the relation between bioaerosol levels and the occupant density of the dining area.

Isolation and Identification of Filamentous Fungi from Indoor Air of a Sogokju Traditional Rice Wine Factory (소곡주 공장의 공기로부터 곰팡이의 분리 및 동정)

  • Park, Ji-Eun;Jeon, Young-Jae;Kim, Ji-Hye;Kim, Seong-Hwan
    • The Korean Journal of Mycology
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • To investigate the mycoflora of indoor air in a Sogokju, traditional rice wine, factory, fungi were sampled and analyzed from the air of several rooms in the factory using an Anderson air sampler and from two kinds of Nuruk. Twelve fungal species belonging to the genera of Aspergillus, Penicillium, Gibberella, Cladosporium, and Talaromyces were isolated. Species belonging to Aspergillus and Penicillium genera were the major species. Seven different species of Penicillium were isolated from each different room of the factory. The Aspergillus species found from indoor air of the factory was also found from Nuruk. Rhizopus sp. was commonly isolated from Nuruk but not from indoor air of the factory. This is first report of fungi present in indoor air of a traditional rice wine factory in Korea.