• Title/Summary/Keyword: Analog Test

Search Result 532, Processing Time 0.032 seconds

Evaluation of transcutaneous electrical nerve stimulation as an adjunct therapy in trigeminal neuralgia - a randomized double-blind placebo-controlled clinical study

  • Bisla, Suman;Gupta, Ambika;Agarwal, Shalini;Singh, Harneet;Sehrawat, Ankita;Singh, Aarti
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.6
    • /
    • pp.565-574
    • /
    • 2021
  • Background: Trigeminal neuralgia (TN) is a severe form of pain that affects the daily activities of a patient. Transcutaneous electrical nerve stimulation (TENS) therapy is an emerging option for the treatment of acute and chronic pain. The aim of this study was to evaluate the effect of TENS therapy as an adjunct to drug therapy for the treatment of TN. Methods: A total of 52 patients diagnosed with TN according to the International Classification of Headache Disorders (version 3) were included. Each patient was randomized to either the TENS or placebo TENS groups. Intervention was given in continuous mode and 100-Hz frequency for 20 mins biweekly for 6 weeks. Parameters were measured at baseline, TENS completion and 3 months, 6 months, and 1 year of follow up. The parameters observed were mean carbamazepine dose, mean visual analog scale (VAS) score, mean present pain intensity (PPI) score, and functional outcome. Non-parametric analyses, one-way ANOVA and the Kruskal-Wallis test were applied for intragroup comparisons, while the Mann-Whitney U test and independent t-test were used for intergroup comparisons of variables. The chi-square test was applied to analyze categorical data. Results: Compared to the placebo TENS group, the mean dose of carbamazepine in the TENS group was significantly reduced at TENS completion, as well as at 6 months and 1 year follow up. Changes in mean VAS score, mean PPI score, and functional outcome did not show significant differences between the groups (P>0.05). Conclusion: TENS therapy does not lead to any changes in pain levels but it may reduce the mean dose of carbamazepine when used as an adjunct treatment in patients with TN.

The Impact of Community-based Integrated Care Service Policy's Home-visiting Exercise Guidance Services on Depression, Pain, and Balance among the Elderly: A case study (지역사회 통합돌봄 정책에서 방문운동지도 서비스가 노인의 우울증과 통증 그리고 균형에 미치는 영향: 사례 연구)

  • Gwan-Hyeok Go;Byeong-Jo Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.179-188
    • /
    • 2024
  • Purpose : The home-visiting exercise guidance service is a component of the community-based integrated care policy in District J of Busan Metropolitan City. This study aims to investigate the effects of the service provided by physical therapists on depression, pain, and balance among the elderly. Methods : Three elderly individuals were selected as study participants. Depression was assessed using the beck depression inventory (BDI) and the short geriatric depression scale-Korea (SGDS-K). Pain was evaluated using the visual analog scale (VAS). Balance was assessed using the berg balance scale (BBS), functional reach test (FRT), and timed up and go test (TUGT). The evaluation data were compared by averaging the values from the first and eighth sessions. Additionally, the overall satisfaction with the home-visiting exercise guidance service was surveyed. Results : In the depression assessment, the beck depression inventory score decreased (by 16.67±5.69 points), and the short geriatric depression scale score decreased (by 4.67±2.52 points). The visual analog scale score for pain decreased (by 2.67±0.58 points). In the balance assessment, the berg balance scale score increased (by 7.67±2.52 points), the functional reach test distance extended (by 4.67±0.58 cm), and the timed up and go test time decreased (by 5.33±0.58 s). Overall satisfaction with the home-visiting exercise guidance service was high (4.26±0.14 points). Conclusion : The home-visiting exercise guidance service received high satisfaction ratings from the participants. It was effective in reducing depression and pain while improving balance, potentially reducing fall risk factors among the elderly. These findings suggest that the home-visiting exercise guidance service, delivered by physical therapists, could significantly enhance the quality of life for elderly individuals by addressing issues related to depression, pain, and fall prevention within the community. Consequently, it is recommended that this service be continued and expanded as part of government policy.

A Study on the Automatic Test Strategy of the Electronic Circuit Board Using Artificial Intelligence (인공지능기법을 이용한 전자회로보오드의 자동검사전략에 대한 연구)

  • 고윤석
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.12
    • /
    • pp.671-678
    • /
    • 2003
  • This paper proposes an expert system to generate automatically the test table of test system which can highly enhance the quality and productivity of product by inspecting quickly and accurately the defect device on the electronic circuit board tested. The expert system identifies accurately the tested components and the circuit patterns by tracing automatically the connectivity of circuit from electronic circuit database. And it generates automatically the test table to detect accurately the missing components, the misplaced components, and the wrong components for analog components such as resistance, coil, condenser, diode, and transistor, based on the experience knowledge of veteran expert. It is implemented in C computer language for the purpose of the implementation of the inference engine using the dynamic memory allocation technique, the interface with the electronic circuit database and the hardware direct control. And, the validity of the builded expert system is proved by simulating for a typical electronic board model.

A Study on the Test Strategy of the Mounted Devices on the Electronic Circuit Board (부품이 실장된 아날로그 회로 보오드의 검사 전략에 대한 연구)

  • Ko, Yun-Seok;Choi, Byung-Kun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2196-2198
    • /
    • 2001
  • Because the circuit board has the structure connected by circuit patterns, the work to test whether the analog devices or circuits such as resisters, capacitors, inductors, diodes, etc. on the tested board is goof or not is very difficult. This paper proposes the test method of identifing the faulted devices or faulted circuit on the circuit board using guarding circuit. The guarding method is the techniqus measuring accurately the value of the devices by separating the electronic devices to be tested from around it. Finally, the availability and accuracy of the proposed test method is verified by applying the technique to a test electronic circuit.

  • PDF

A Comparative Study of the Effect of Two Analgesic Administration Methods on Post Operative Pain (수술환자에 었어서 마약성 진통제의 자가투여 방법과 근육주사 방법의 효과에 대한 비교연구)

  • 이정화
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.2
    • /
    • pp.401-410
    • /
    • 1997
  • An acute pain is the common experience following surgery. Pain is a most miserable experience in person and most preoperative patients have fear o! postoperative pain. In nursing, it is very important to understand and relieve the pain of post oprative patients as much as possible. This study was designed to compare the descriptive patterns of pain between group of Patient Controlled Analgesia and group of traditional Muscular Injection in surgcal patients. This information can be utilited as data of understanding nursing care and treatment planning for pain in surgical patients. The subjects in this study were 45 post-hysterectomy patients in Gynecology ward in C. N. U. H., in Taejon. Data was collected from May 12 to June 27. 1996. The instrumants used for this study were subjective Visual Analog Scale, Objedive nonverbal pain scale composed of Facial Apperance. Vocal Sound Change, and Sweating score. and the Melzack's Mcgill pain Qusetionaire. nine Items of Developmental Pain Intensity Scale by Lee En Ok. Analysis of data was done by using S. P. S. S. percentage, t-test, x²-test. ANOVA, and Repeated measure ANOVA. Results were obtained as follows. 1. Hypothesis 1 : There was very highly statistically significant difference in subjective self-report pain score(Visual Analog Scale) between PCA Group and IM Group(P=0.0001). 2. Hypothesis 2 : There was very highly statistically significant difference in muscle strength score (Visual Analog Scale) between PCA Group and IM group(P0.0001). 3. Hypothesis 3 : There was very highly statistically significant difference in facial appearance score between PCA Group and IM group(P=0.0001). 4. Hypothesis 4 : There was very highly statistically significance difference in vocal sound change score between PCA Group and IM group(P=0.0001). 5. Hypothesis 5 : There was no statistically significant difference sweating scores between PCA group and IM group(F=2.50, P=0.1220). But, postoperation time of 12, 24 was statistically difference between two groups(P=0.0001). So, it was partially supported. 6. Hypothesis 6 : There was very highly statistically significant difference in vocabulary pain score between PCA Group and IM group. 7. Hypothesis 7 : There was very highly statistically significant difference in amounts of total analgesic between PCA Group and IM group. There was very highly statistically significant difference in Visual Analog Pain Score, Facial Appearance Score, Vocal Sound Change Score, Vocabulary Score, amounts of total analgesic between PCA group and IM group. So, It is verified to asses of postoperative pain with VAS, Checklist of facia appearance, vocal sound change, and sweating, and Vocabulary Scale.

  • PDF

An Information Transmission Method of the DC Switchgear for Light Railway Vehicle (경량전철용 직류배전반의 정보 전송방식)

  • Lee, H.D.;Kim, S.N.;Ryu, S.P.;Lee, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.143-145
    • /
    • 2005
  • This paper describes the transmission method of an information using communication networks between RTU(Remote Terminal Unit) and PCU(Protection and Control System) of the DC switchgear for Light Railway Vehicle. Also the test result carried out in the laboratory was represented. In this test, transmission signal waveform, polling time, response time and request/response frame between RTU and PCU were measured. The field test including the measurements of analog signal and status of the digital logic operation of PCU was conducted in Gyeongsan Test Track.

  • PDF

A Design and Implementation of Circuit for Efficient Power LED Dimming Control (효율적인 고출력 LED 디밍 제어를 위한 회로 설계 및 구현)

  • Kim, Doo-Hyun;Choi, Jae-Ho;Cho, Beom-Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2280-2288
    • /
    • 2014
  • The conventional dimming control methods of LED (Light-emitting dioades) include Analog, PWM (Pulse Width Modulation), and FM (Frequency Modulation) Control. Analog dimming is controlled by adjusting forward current of Power LED. Although Analog dimming is possible to control linearly the brightness levels on a whole range (0%~100%), it comes into existence a variation of wavelength by changing the Power LED's forward current. PWM dimming has achieved by varying in duty of full current flowing to the Power LED. Generally, PWM dimming doesn't make variation of wavelength but have difficulty with adjusting the linear brightness level between 0% and 10%. FM dimming method is on the same wavelength as PWM dimming, however, it has problem of flickering at low level of dimming. This paper propose a efficient dimming control method of Power LED in order to overcome the disadvantages of the above mentioned methods. We apply to Analog method in low level of dimming control and use PWM method in dimming range from 10% to 100%. For the experiment, we design and implement a circuit and test the proposed method. Consequently, we can control the linear brightness of Power LED across the whole range and get the constant wave at different dimming level. The experimental results show the benefits of the proposed method.

Test Methods of a TRNG (True Random Number Generator) (TRNG (순수 난수 발생기)의 테스트 기법 연구)

  • Moon, San-Gook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.803-806
    • /
    • 2007
  • Since the different characteristics from the PRNG (Pseudo Random Number Generator) or various deterministic devices such as arithmetic processing units, new concepts and test methods should be suggested in order to test TRNG (Ture Random Number Generator). Deterministic devices can be covered by ATPG (Automatic Test Pattern Generation), which uses patterns generated by cyclic shift registers due to its hardware oriented characteristics, pure random numbers are not possibly tested by automatic test pattern generation due to its analog-oriented characteristics. In this paper, we studied and analyzed a hardware/software combined test method named Diehard test, in which we apply continuous pattern variation to check the statistics. We also point out the considerations when making random number tests.

  • PDF

Design of a Rule-Based Solution Based on MFC for Inspection of the Hybrid Electronic Circuit Board (MFC 기반 하이브리드 전자보오드 검사를 위한 규칙기반 솔루션 설계)

  • Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.9
    • /
    • pp.531-538
    • /
    • 2005
  • This paper proposes an expert system which is able to enhance the accuracy and productivity by determining the test strategy based on heuristic rules for test of the hybrid electronic circuit board producted massively in production line. The test heuristic rules are obtained from test system designer, test experts and experimental results. The guarding method separating the tested device with circumference circuit of the device is adopted to enhance the accuracy of measurements in the test of analog devices. This guarding method can reduce the error occurring due to the voltage drop in both the signal input line and the measuring line by utilizing heuristic rules considering the device impedance and the parallel impedance. Also, PSA(Parallel Signature Analysis) technique Is applied for test of the digital devices and circuits. In the PSA technique, the real-time test of the high integrated device is possible by minimizing the test time forcing n bit output stream from the tested device to LFSR continuously. It is implemented in Visual C++ computer language for the purpose of the implementation of the inference engine using the dynamic memory allocation technique, the interface with the electronic circuit database and the hardware direct control. Finally, the effectiveness of the builded expert system is proved by simulating the several faults occurring in the mounting process the electronic devices to the surface of PCB for a typical hybrid electronic board and by identifying the results.

Digital Microflow Controllers Using Fluidic Digital-to-Analog Converters with Binary-Weighted Flow Resistor Network (이진가중형 유체 디지털-아날로그 변환기를 이용한 고정도 미소유량 조절기)

  • Yoon, Sang-Hee;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1923-1930
    • /
    • 2004
  • This paper presents digital microflow controllers(DMFC), where a fluidic digital-to-analog converter(DAC) is used to achieve high-linearity, fine-level flow control for applications to precision biomedical dosing systems. The fluidic DAC, composed of binary-weighted flow resistance, controls the flow-rate based on the ratio of the flow resistance to achieve high-precision flow-rate control. The binary-weighted flow resistance has been specified by a serial or a parallel connection of an identical flow resistor to improve the linearity of the flow-rate control, thereby making the flow-resistance ratio insensitive to the size uncertainty in flow resistors due to micromachining errors. We have designed and fabricated three different types of 4-digit DMFC: Prototype S and P are composed of the serial and the parallel combinations of an identical flow resistor, while Prototype V is based on the width-varied flow resistors. In the experimental study, we perform a static test for DMFC at the forward and backward flow conditions as well as a dynamic tests at pulsating flow conditions. The fabricated DMFC shows the nonlinearity of 5.0% and the flow-rate levels of 16(2$^{N}$) for the digital control of 4(N) valves. Among the 4-digit DMFC fabricated with micromachining errors, Prototypes S and P show 27.2% and 27.6% of the flow-rate deviation measured from Prototype V, respectively; thus verifying that Prototypes S and P are less sensitive to the micromachining error than Prototype V.V.