• Title/Summary/Keyword: Alarm-System

Search Result 1,030, Processing Time 0.037 seconds

Harmony Matters in Alarm Design: Investigating the Impact of Consonance on Alarm System

  • Ilgang Mukko Lee;Yunsun Alice Hong;Juhyun Jay Lee;Kwanghee Han
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.4
    • /
    • pp.406-416
    • /
    • 2023
  • Alarm system performance is a critical aspect of safety. While existing research has extensively examined the influence of acoustic attributes on alarm performance, consonance's impact remains largely uncharted territory. This study bridges this research gap by investigating the effect of consonance on alarm systems. We extend our investigation to encompass not only the sound characteristics of the alarm but also the acoustic qualities of the surrounding environment, recognizing their potential impact on alarm efficacy. Prior studies consistently link consonance to annoyance levels, resulting in a negative user experience. Thus, we explore the relationship between consonance and alarm system performance, with a particular focus on modulating annoyance as an explanatory factor. Utilizing an oddball paradigm, we categorized standard and oddball sounds into consonant and dissonant types, creating four sound combinations. Participants were asked to respond to the irregularly presented oddball sounds while ignoring the constantly presented standard sounds. Our results reveal significant differences between groups, with the Standard Consonant/Oddball Dissonant (SC/OD) group displaying notably slower response times than the Standard Dissonant/Oddball Consonant (SD/OC) group. This reaction time variation aligns with differences in annoyance levels, as the SC/OD group reports higher annoyance, suggesting that reaction time discrepancies may be linked to increased arousal due to heightened annoyance.

Development of Alarm Processing Algorithm for SAS (변전소 자동화를 위한 Alarm Processing 방법 개발)

  • Jin, B.G.;Hyun, S.H.;Lee, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.161-162
    • /
    • 2006
  • There are many alarms in Substation Automation System because of data types and quantities increasing, so it is very difficult for operators to know the actual situations. In order to help operators easily make decision, some unnecessary alarms should be removed or combined as one. In this paper, alarm processing is using the structure of substation system and the relation of measured data and events to make some rules. Conventional alarm processing just gives data, but proposed alarm processing gives the whole information. In a simulation model system, the data such as voltage, current and CB status are collected by HyperSim and saved in DB, then proposed alarm processing has been testified using those data based on real-time simulation.

  • PDF

A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment (에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구)

  • Lee, Tae Gyu;Choi, Kyeong Seo;Shin, Youn Soon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.7
    • /
    • pp.217-224
    • /
    • 2022
  • Today, with the development of technology and industry, fire accidents in special buildings are increasing as special buildings increase. However, despite the rapid development of information and communication technology, human casualties are steadily occurring due to the underdeveloped and ineffective indoor fire alarm system. In this study, we confirmed that the existing indoor fire alarm system using acoustic alarm could not deliver a sufficiently large alarm to the in-room personnel. To improve this, we designed and implemented a fire alarm system using edge computing and beacons. The proposed improved fire alarm system consists of terminal sensor nodes, edge nodes, a user application, and a server. The terminal sensor nodes collect indoor environment data and send it to the edge node, and the edge node monitors whether a fire occurs through the transmitted sensor value. In addition, the edge node continuously generate beacon signals to collect information of smart devices with user applications installed within the signal range, store them in a server database, and send application push-type fire alarms to all in-room personnel based on the collected user information. As a result of conducting a signal valid range measurement experiment in a university building with dense lecture rooms, it was confirmed that device information was normally collected within the beacon signal range of the edge node and a fire alarm was quickly sent to specific users. Through this, it was confirmed that the "blind spot problem of the alarm" was solved by flexibly collecting information of visitors that changes time to time and sending the alarm to a smart device very adjacent to the people. In addition, through the analysis of the experimental results, a plan to effectively apply the proposed fire alarm system according to the characteristics of the indoor space was proposed.

A Study on the False Alarm Management of Alarm Monitoring Service (기계경비의 오경보 관리방안)

  • Chung, Tae-Hwang
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.93-99
    • /
    • 2012
  • This study is to present false alarm management of alarm monitoring service, by literature analysis and interview with the persons in charge of service of alarm monitoring service companies. To reduce false alarm by customer's mistake, development of educational tool that could provide practical effect is needed. Also institutional consent to charge a specific sum of money could be considered for unnecessary dispatch that occurred by customer's mistake. To improve the false alarm by defect of equipments and installation of electronic security system, standardization of technical regulation and system installation is necessary. And to improve the performance of passive infrared sensor that cause most false alarm, the development of new type of sensor is required. It could be considered that guideline on educational contents and term definition about false alarm could be come under the security regulation.

The study of Connection Emergency lantern with Fire Alarm System (자동화재탐지설비와 휴대용비상조명등의 연동에 대한 연구)

  • Chun, Jung-Ham;Lee, Sang-Hwa;Kwon, Oh-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.108-111
    • /
    • 2008
  • Emergency lantern is an escape equipment of fire fighting. This equipment of obligation installation in buildings. But, We cast doubt on this equipment's reliability. Therefor we have need to study of this equipment's reliability. This paper research general emergency lantern for up grade reliability. For connection to fire alarm system, alarm for get lost general emergency lantern, and pilot lamp for interruption of electric power, and charge to rechargeable battery in general emergency lantern from fire alarm system. Then view very good result in reliability.

  • PDF

Structural Reliability Analysis of Automatic Fire Detectors for Reduction of False Alarms (화재감지기의 오보 감소를 위한 구조 신뢰도 분석)

  • 김주홍;임현교
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.1
    • /
    • pp.6-12
    • /
    • 1993
  • Now it is reported that there are many companies and factories which confront to the problem of false alarm in Automatic Fire Detecting System (AFDS). Though an AFDS is a high-priced and very important device in detecting a fire. the problem degrades the reliability and utility, eventually faith. of the system. This is a research concerned about the problem of false alarm of fire detectors in an AFDS. Structure of detectors was modeled up as a general K out-of n system. and reliability characteristics including false alarm rate and missed alarm rate, are derived from it. For decision of an optimal structure of detectors. preliminary analysis on various criteria is accomplished. It is concluded that appropriate modification of a detector with plural sensors may increase the system reliability and decrease the false alarm rate.

  • PDF

Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver (재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Yang, Seung-Hyun;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

Development of a foaling alarm system using an accelerometer

  • Youngwook, Jung;Honghee, Chang;Minjung, Yoon
    • Journal of Animal Science and Technology
    • /
    • v.64 no.6
    • /
    • pp.1237-1244
    • /
    • 2022
  • Horse breeders suffer massive economic losses due to dystocia, abortion, and stillbirths. In Thoroughbred mares, breeders often miss the foaling process because approximately 86% of the foaling events occur from 19:00 to 7:00; consequently, breeders cannot assist mares experiencing dystocia. To solve this problem, various foaling alarm systems have been developed. However, there is a need to develop a new system to overcome the shortcomings of the existing devices and improve their accuracy. To this end, the present study aimed to (1) develop a novel foaling alarm system and (2) compare its accuracy with that of the existing FoalertTM system. Specifically, eighteen Thoroughbred mares (11.9 ± 4.0 years old) were included. An accelerometer was used to analyze specific foaling behaviors. Behavioral data were transmitted to a data server every second. Depending on the acceleration value, behaviors were automatically classified by the server as categorized behaviors 1 (behaviors without change in body rotation), 2 (behaviors with sudden change in body rotation, such as rolling over), and 3 (behaviors with long-term change in body rotation, such as lying down laterally). The system was designed to alarm when the duration of categorized behaviors 2 and 3 was 12.9% and that of categorized behavior 3 was 1% during 10 min. The system measured the duration of each categorized behavior every 10 min and transmitted an alarm to the breeders when foaling was detected. To confirm its accuracy, the foaling detection time of the novel system was compared with that of FoalertTM. The novel foaling alarm system and FoalertTM alarmed foaling onset respectively 32.6 ± 17.9 and 8.6 ± 1.0 min prior to foal discharge, and the foaling detection rate of both systems was 94.4%. Therefore, the novel foaling alarm system equipped with an accelerometer can precisely detect and alert foaling onset.

Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings (공동주택 화재경보 발생음 특성에 관한 실험연구)

  • Lee, Min-Joo;Kang, Hee-Hyuk;Kwon, Bong-Suk;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

A Study of Data Mining Methodology for Effective Analysis of False Alarm Event on Mechanical Security System (기계경비시스템 오경보 이벤트 분석을 위한 데이터마이닝 기법 연구)

  • Kim, Jong-Min;Choi, Kyong-Ho;Lee, Dong-Hwi
    • Convergence Security Journal
    • /
    • v.12 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The objective of this study is to achieve the most optimal data mining for effective analysis of false alarm event on mechanical security system. To perform this, this study searches the cause of false alarm and suggests the data conversion and analysis methods to apply to several algorithm of WEKA, which is a data mining program, based on statistical data for the number of case on movement by false alarm, false alarm rate and cause of false alarm. Analysis methods are used to estimate false alarm and set more effective reaction for false alarm by applying several algorithm. To use the suitable data for effective analysis of false alarm event on mechanical security analysis this study uses Decision Tree, Naive Bayes, BayesNet Apriori and J48Tree algorithm, and applies the algorithm by deducting the highest value.