• 제목/요약/키워드: Alarm Unit

검색결과 84건 처리시간 0.025초

사례기반의 암전류 원인 진단 모델링 및 표준화 (Case Based Diagnosis Modeling of Dark Current Causes and Standardization of Diagnosis Process)

  • 조행득
    • 한국자동차공학회논문집
    • /
    • 제25권2호
    • /
    • pp.149-156
    • /
    • 2017
  • Various kinds of accessories(e.g., clock, radio, automatic door locks, alarm devices, etc.) or unit components (e.g., black box, navigation system, alarm, private audio, etc.) require dark current even when the vehicle power is turned off. However, accessories or unit components can be the causes of excessive dark current generation. It results in battery discharge and the vehicle's failure to start. Therefore, immediate detection of abnormal dark current and response are very important for a successful repair job. In this paper, we can increase the maintenance efficiency by presenting a standardized diagnostic process for the measurement of the dark current and the existing problem. As a result of the absence of a system to block the dark current in a vehicle, diagnosis and repair were performed immediately by using a standardized dark current diagnostic process.

생체 신호를 활용한 영아 돌연사 알람 시스템 (Alarm System for Sudden Infant Death using Bio-Signals)

  • 윤수정;인치호
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.197-202
    • /
    • 2016
  • 본 논문에서는 영아 돌연사를 방지하기 위해 영아의 생체신호를 분석하여 위험상황이 발생했을 때 보호자에게 위험신호를 알려주는 영아 돌연사 모니터링 시스템을 제안한다. 영아 돌연사(SID)는 생후 한 달에서 일년 사이의 건강한 아기가 원인불명으로 사망하는 것을 말한다. 제안한 영아 돌연사 모니터링 시스템은 생체신호를 센싱하는 부분과 생체 신호를 처리하는 프로세서부와 모니터링 및 알람부분으로 구성된다. PPG 센서를 사용하여 생체신호를 센싱하고 프로세서부에서는 센서를 통해 획득한 신호를 동잡음을 제거하여 부모에게 알람 및 모니터링 할 수 있게 하였다. 제안한 시스템은 영아의 심박동을 분석하여 위험상황인 경우 보호자에게 모니터링 및 경고 알람을 보내게 된다. 시스템의 실제 구현을 통해 모니터링 시스템의 성능을 평가하였다.

불꽃 감지기에서 오동작 방지에 관한 연구 (A Study on the protection of false alarm in the UV/IR flame detector)

  • 임병현;박성진;임종연;황종선;김영민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.209-212
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults, filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

적외선 센서와 무선통신을 이용한 열차접근경보시스템 개발 (Railway Access Alarm System Using Infrared Distance Sensor and Wireless Communication)

  • 황윤태;황성태;이윤성;김도근;이태규
    • 한국콘텐츠학회논문지
    • /
    • 제17권11호
    • /
    • pp.303-311
    • /
    • 2017
  • 국내의 철도작업자의 안전사고는 열차 운행 기관사의 부주의, 선로변 작업자의 감각차단 현상 및 신호수의 실수 등으로 인해 추돌사고가 주요 원인으로 매년 꾸준히 발생하고 있으며 이러한 안전사고를 예방할 수 있는 대책 마련이 시급하다. 따라서 철도 작업 시, 선로변 작업자가 청각과 시각적으로 열차접근을 검지하여 열차 접근으로부터 대피할수 있는열차접근경보시스템을 개발하였다. 이 시스템은 철도 작업장에서 1.5km 이상 전후방 선로에 열차자동겸지장치를 설치하여 자동으로 열차 진입을 검지하도록 하고 작업장에 설치된 실시간 경보장치에 유무선으로 검지 신호를 전달하도록 하며, 검지신호를 수신한 실시간 경보장치는 LED 경보등 및 사이렌 등으로 작업자에게 경보신호를 주는 방식으로 작동된다. 이전의 시스템에 비해 원거리에 있는 열차접근의 검지가 가능하고 주로 무선통신방식을 채택하여 통신배선작업이 불필요하며 충전식 배터리와 태양광 충전장치를 통해 외부 전원 공급이 어려운 현장의 상황에 적합한 이점이 있다. 시스템의 현장검증을 통하여 열차자동검지장치와 실시간 경보장치의 성능평가를 실시하였고 100%구동을 확인하여 신뢰성을 검증하였다.

소형 표적 탐지를 위한 파노라믹 적외선 영상 향상 장치 및 경보시스템 구현 (The Realization of Panoramic Infrared Image Enhancement and Warning System for Small Target Detection)

  • 김기홍;김주영;정태연;전병균;이의혁;김덕규
    • 한국멀티미디어학회논문지
    • /
    • 제8권1호
    • /
    • pp.46-55
    • /
    • 2005
  • 본 논문에서는 소형 위협체를 조기에 탐지하여 위치를 알려주는 파노라믹 적외선 영상 경보 장치를 구현하였고, 경보 성능 향상을 위한 적외선 영상 향상 기법을 제안하였다. 구현 장치는 센서 헤드 유닛, 신호 처리 유닛 등으로 구성된다. 센서 헤드 유닛은 1차원 다중 배열 적외선 센서를 정속으로 고속 회전하여 360도의 넓은 시계 영역을 가지는 파노라믹 열영상을 획득한다. 신호 처리 유닛은 파노라믹 영상을 90도의 부영상으로 나누고, 각 부영역의 통계적 특성에 따라 적응적 평탄역값(adaptive plateau value)을 구한다 그리고 적응적 평탄역값으로 히스토그램을 변화시킴으로써 위협체을 두드러지게 하였으며, 실시간 처리를 위하여 DSP와 FPGA를 이용하여 장치를 구현하였다. 구현 시스템에 제안한 영상 향상 기법을 적용한 결과 기존 기법에 비해 오경보율이 낮음과 시각적으로 위협체의 식별이 용이함을 확인하였다.

  • PDF

머신비전을 이용한 PWM Shaft의 자동검사 시스템 개발 (Development of an Automatic Inspection System for PWM Shaft Using Machine Vision)

  • 배진호;김성관
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.125-130
    • /
    • 2013
  • In this paper, in order to overcome shortcomings of manual inspection for the automotive PWM Shaft, we developed an automated inline inspection system. The automated inline inspection system consists of the work feeder unit, conveying unit, outer diameter check unit, run-out and roundness check unit, machine vision, defective separation unit and status alarm unit. We used the machine vision system for automatic inspection process and designed the inline systems for automatic feeding and selecting process. Also the repeated operation test was performed in order to verify the precision and reliability of the proposed automated inline inspection system.

분리수거를 위한 페트병 분리시스템의 구현 (Implementation of Plastic Bottle Classification System for Recycling)

  • 박용하;박지훈;정호영;이주상;이중엽
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2021년도 춘계학술대회
    • /
    • pp.365-368
    • /
    • 2021
  • 본 연구에서는 적외선 센서를 이용한 페트병 분리수거 시스템을 구현하였다. 제안된 시스템은 인식부, 제어부, 알람부 및 구동부로 구성된다. 인식부는 페트병을 감지해 페트병과 센서와의 거리를 측정하고 값을 추출하고 추출된 값을 표준 범위와 비교하여 값이 표준 범위를 벗어날 경우에는 제어값을 제어부에 전송하고, 특정범위를 넘어간 경우 라벨 혹은 뚜껑의 유무결과를 제어부에 전송한다. 제어부에서는 센서부로부터 전송받은 결과값에 따라서 수거함의 입구를 개방하거나 알람부를 제어하는 기능을 수행한다. 제안된 시스템 구현을 위하여 인식부는 적외선 센서로 구현하였고, 제어부는 C언어 기반의 아두이노 스케치 프로그램으로 제작하였다. 또한, 인식부와 제어부는 아날로그 신호를 이용하여 통신할 수 있게 하였다. 제안된 시스템은 정해진 알고리즘에 따라 페트병의 라벨과 뚜껑의 유무를 정확히 판단한 후 라벨 혹은 뚜껑이 부착되었을 때 수거함의 입구를 막는다. 국민 1인당 배출되는 폐기물의 양이 높고 재활용이 되지 않아 쓰레기의 대다수를 소각시키고 있는 상황에서 본 연구에서 제안한 시스템을 통하여 페트병의 재활용률을 높이기를 기대한다.

  • PDF

화재 수신기용 과도현상 보호시스템 개발에 관한 연구 (A Study on the Transient Phenomenon Protection System Development for Fire Alarm System Control Unit)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제23권2호
    • /
    • pp.55-61
    • /
    • 2009
  • 본 연구에서는 서지나 순간 과전압 등에 의한 과도현상으로부터 보호될 수 있는 높은 신뢰성의 화재수신기가 될 수 있도록 과도현상 보호시스템의 개발에 대한 연구를 수행하였고, 보호시스템의 성능을 시험으로 입증함으로써 과도현상 보호시스템을 개발할 수 있는 기틀을 마련하였다. 과도현상 보호시스템의 개발을 위한 프로세스 정립과 이론을 바탕으로 과도현상으로부터 보호될 수 있는 1단계 및 2단계 보호시스템을 개발하였고, 소방법 및 관련규정에서 제시하는 제반 성능조건으로 시험하고 만족스런 결과를 얻음으로써, 과도현상 보호시스템을 개발할 수 있는 엔지니어링 데이터 구축과 원천기술을 확립하였다.

혼천시계의 시보시스템 구조 분석 (AN ANALYSIS OF STRUCTURE ON TIME SIGNAL SYSTEM OF HONCHEONSIGYE)

  • 김상혁;이용삼
    • 천문학논총
    • /
    • 제28권2호
    • /
    • pp.17-23
    • /
    • 2013
  • Song I-Yeong (1619 ~ 1692), who was an astronomy professor of Gwansanggam (觀象監, Bureau of Astronomy), created the Honcheonsigye (渾天時計, Armillary Clock) in 1669 (10th year of King Hyeonjong Era). Honcheonsigye was a unique astronomical clock which combined an armillary sphere, the traditional astronomical instrument of the Far East, with the power mechanism of western alarm clock. The clock part of this armillary clock is composed of two major parts which are the going-train, power unit used the weight, and the time signal system in a wooden case. The time signal system is composed of four parts which are the time-annunciator, the striking train, the 12 different time-announcing medallions and the sound bell. This clock has been neglected for many years and its several components have been lost. This study is to understand the structure of time signal system and suggests the restoration process.

A Study on the Design of Water Pollution Alarm System with Solar Cell

  • Yoon, Suk-Am;Cha, In-Su;Yu, Gwon-Jong
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.85-95
    • /
    • 2000
  • As the industry has been growing rapidly, the problem of environmental pollution has been on the rise seriously. In this paper, we used solar cells at the power supply unit of the equipment, which has been sold at present, for measuring the quality of water in order to complement the problem. Also, to get rid of the inconvenience that the examiners must go the job site, check and collect the polluted water we set the goal at designing the water pollution alarm system which measures the quality of water automatically using one-chip microprocessor and materializing the program.

  • PDF