• Title/Summary/Keyword: Air pollution particle

Search Result 299, Processing Time 0.029 seconds

Comparative In Vitro Biological Toxicity of Four Kinds of Air Pollution Particles

  • Shin, Han-Jae;Cho, Hyun Gi;Park, Chang Kyun;Park, Ki Hong;Lim, Heung Bin
    • Toxicological Research
    • /
    • v.33 no.4
    • /
    • pp.305-313
    • /
    • 2017
  • Accumulating epidemiological evidence indicates that exposure to fine air pollution particles (APPs) is associated with a variety of adverse health effects. However, the exact physiochemical properties and biological toxicities of fine APPs are still not well characterized. We collected four types of fine particle (FP) (diesel exhaust particles [DEPs], natural organic combustion [NOC] ash, synthetic organic combustion [SOC] ash, and yellow sand dust [YSD]) and investigated their physicochemical properties and in vitro biological toxicity. DEPs were almost entirely composed of ultrafine particles (UFPs), while the NOC, SOC, and YSD particles were a mixture of UFPs and FPs. The main elements in the DEPs, NOC ash, SOC ash, and YSD were black carbon, silicon, black carbon, and silicon, respectively. DEPs exhibited dose-dependent mutagenicity even at a low dose in Salmonella typhimurium TA 98 and 100 strains in an Ames test for genotoxicity. However, NOC, SOC, and YSD particles did not show any mutagenicity at high doses. The neutral red uptake assay to test cell viability revealed that DEPs showed dose-dependent potent cytotoxicity even at a low concentration. The toxicity of DEPs was relatively higher than that of NOC, SOC, and YSD particles. Therefore, these results indicate that among the four FPs, DEPs showed the highest in vitro biological toxicity. Additional comprehensive research studies such as chemical analysis and in vivo acute and chronic inhalation toxicity tests are necessary to determine and clarify the effects of this air contaminant on human health.

Effect of May 31, 2022 Miryang Forest Fire on Fine Particle Concentration in Nearby Urban Areas (2022년 5월 31일 발생한 밀양산불이 인근 도시 지역의 미세먼지 농도에 미치는 영향)

  • Byung-Il Jeon
    • Journal of Environmental Science International
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 2023
  • This study investigated the effect of May 31, 2022 Miryang wildfire on fine particle concentrations in Busan and Gimhae, which are neighboring urban areas. In addition, fine particle characteristics and air pollution concentrations were investigated in Miryang, where haze occurred. The Miryang city wildfire that occurred on May 31, 2022, at 0925 LST, was driven by strong north winds and increased fine particle concentrations in Dongsangdong and Jangyoodong, Gimhae City, which are approximately 35 km to the southeast and south, respectively, of the wildfire occurrence site. Furthermore, the fine particle concentration in Myeongjidong, which is approximately 50 km south-southeast of the wildfire site, exhibited a temporary increase at 1400 LST owing to the effects of wildfire smoke. On the morning of June 1, the day after the fire, the Miryang area had very bad visibility because of the smoke from the fire. Therefore the PM10 and PM2.5 concentrations in Naeildong, 3 km south of the wildfire site, were 276 ㎍/㎥ and 222 ㎍/㎥, respectively, at 1200 LST. In addition, the gases O3, CO, and SO2 showed high concentrations at the time of haze generation. This study provides insights into policy making in response to the rapid increase in fine dust when wildfire occurs near cities.

Development of IoT based Real-Time Complex Sensor Board for Managing Air Quality in Buildings

  • Park, Taejoon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.75-82
    • /
    • 2018
  • Efforts to reduce damages from micro dust and harmful gases in life have been led by national or local governments, and information on air quality has been provided along with real-time weather forecast through TV and internet. It is not enough to provide information on the individual indoor space consumed. So in this paper, we propose a IoT-based Real-Time Air Quality Sensing Board Corresponding Fine Particle for Air Quality Management in Buildings. Proposed board is easy to install and can be placed in the right place. In the proposed board, the air quality (level of pollution level) in the indoor space (inside the building) is easy and it is possible to recognize the changed indoor air pollution situation and provide countermeasures. According to the advantages of proposed system, it is possible to provide useful information by linking information about the overall indoor space where at least one representative point is located. In this paper, we compare the performance of the proposed board with the existing air quality measurement equipment.

FIELD EXPERIENCE OF PORTABLE SMPS+C NANO PARTICLE SIZER

  • Gerhart, Ch.;Grimm, H.J.;Heim, M.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.47-48
    • /
    • 2003
  • This new family of portable real time SEQUENTIAL MOBILITY PARTICLE COUNTER and SIZER (SMPS+C) is designed for mobility and easy field use. An integrated battery assures hours of operation, a data logger system storage of all optioned results and a user friendly powerful software easy operation. This technology not only simplifies the SMPS operation, but it permits new on site application monitoring up to a remote wireless telephone operation. (omitted)

  • PDF

Lagrangian Particle Dispersion Model Based on Non-equilibrium Level 2.5 Closure Model in the Convective Boundary Layer (열대류 경계층에서 비평형 2.5 난류모델을 기초로 한 라그란지안 입자 확산 모델)

  • 구윤서
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.167-168
    • /
    • 2000
  • 복잡한 구조를 갖고 시간에 따라서 변하는 바람장내에서 공장굴뚝과 같은 점오염원에서 배출되는 오염물질의 확산을 계산하기 위해서 라그란지안 입자확산모텔(Lagrangian Particle Dispersion Model, LPDM)을 사용하는 것이 최근의 연구 동향이다. 구윤서(1999a, 1999b)는 중립 및 안정한 대기조건에서 바람장 계산시 비평형 2.5 난류모델을 이용한 LPDM을 개발하여 복잡한 대기흐름내 확산현상을 보다 정확히 모사할 수 있는 LPDM을 제시하였다. (중략)

  • PDF

Particle Refractive Index Effects on Aerosol Size Distribution Measured by An Optical Particle Counter (입자의 굴절률변화에 따른 광학적 입자 계수기로 측정된 대기 에어러솔 크기분포의 측정오차)

  • 이권호;김영준;정희숙;정창훈
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.314-315
    • /
    • 2002
  • 대기중에는 다양한 크기와 모양, 그리고 화학성분을 가진 입자들이 존재한다. 이러한 입자들은 발생원이 다양하고 대기중에 존재하면서 광화학적인 변화를 거쳐 형성되기도 한다. 입자의 화학조성과 크기는 발생원을 구분하기 위한 일반적인 척도로 쓰이고 있다. 대기 에어러솔의 크기분포특성은 에어러솔의 변화 요소인 발생원과 제거 그리고 동역학적인 과정을 이해하는데 중요한 역할을 한다. (중략)

  • PDF

Evaluation of an electrical impactor with porous metal substrate (다공성 금속판을 이용한 전기적 임팩터의 평가)

  • Jeong Jeong-Seon;Gwon Sun-Park;Lee Gyu-Won
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.276-277
    • /
    • 2002
  • One of drawbacks of the inertial impactor measurement is the required long sampling time (Keskinen et al., 1992). In a gravimetric method, an impaction substrate must be weighed and placed on the corresponding collection plate before being assembled. After sampling, the inertial impactor is disassembled and the collection plate is weighted again. The sampling time depends on the sampled particle mass because the collected particle mass must be sufficiently high to be measured by a sensitive microbalance. (omitted)

  • PDF

Physico-chemical characterization of individual particles emitted from the air pollution point sources (대기 점오염원에서 배출되는 개별입자상물질의 물리화학적 특성)

  • Park Jeong-Ho;Suh Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.761-770
    • /
    • 2005
  • Scanning electron microscopy / energy dispersive X-ray analyzer(SEM/EDX) has played an important role for evaluation the source of atmospheric particle because it is a powerful tool for characterizing individual particles. The SEM/EDX system provides various physical parameters like optical diameter, as well as chemical information for a particle-by-particle basis. The purpose of the study was to classify individual particle emitted from the point sources based on clustering analysis and physico-chemical analysis by SEM/EDX. The total of 490 individual particle were analyzed at 8 point sources including coal-fired power plant, incinerator, H-C oil boiler, and metal manufacturing industry. The main components were Si and AI in the coal-fired power plant, Cl and Na in the domestic waste Incinerator, S in the H-C oil boiler and S and Fe in the metal manufactory industry, respectively.

A Study on the Shapes of Aerosol Particles at a Bus Stop in the Eastern Part of Seoul (도심 내 버스정류장 부근의 에어로졸 입자 크기 및 형상 관찰)

  • Jeong, Sang Bin;Heo, Ki Joon;Sin, Chang Hoon;Zhao, YuanQing;Lee, Byung Uk
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.109-114
    • /
    • 2016
  • People in metropolitan cities can be exposed to particulate air pollutants at public transportation systems such as bus stops. In this study, we sampled aerosol particles with an impactor at a bus stop. We analyzed the shapes of these particles with an optical microscope. It was estimated that fibers, silicons, byproducts of combustion, and pollens existed in the air environments at the bus stop with analysis of shapes of sampled particles.