• Title/Summary/Keyword: Air induction system

Search Result 141, Processing Time 0.025 seconds

Particulate Matter (PM2.5) State Inference by Rule Induction (규칙기반 초미세먼지 상태 추론)

  • Choi, Rock-Hyun;Kang, Won-Seok;Son, Chang-Sik
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.13 no.4
    • /
    • pp.179-185
    • /
    • 2018
  • Particulate Matter (PM2.5) has various adverse effects on health. Climate and industry activity and traffic volume are the main causes, especially in urban area. In order to construct an effective forecasting system, many measurement systems are required, but it is impossible in reality. Therefore, in this study, we propose a method to infer PM2.5 condition by using rule induction technique. The experimental results showed a classification accuracy of 71%.

Integrated Driver for the Full Rotation Using Six-axial Forces by the Induction Type of Axial-gap Motor (유도형 축방향 모터의 6축력 제어를 이용한 대회전 구현용 통합 구동기)

  • Jung Kwang-Suk;Lee Sang-Heon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.8
    • /
    • pp.798-804
    • /
    • 2006
  • To overcome the limited relative uncertainty and work range of the existing planar stage and the bulk structure of the contact-less motor for rotation, the novel operating principle to realize the precise rotation is suggested. It uses the two-axial vector forces, normal force and thrust force, of three-induction type of axial motors located $120^{\circ}$ apart, resulting in the contact-free rotation of the mover. Firstly in this paper, the magnetic forces across the air gap are modeled and simulated under the various conditions. It clarifies the feasible range of the derived solution. And the algorithm compensating the strong cross couple between the forces and the control inputs; generally AC magnitude and slip frequency, is given to realize the independent control of six axes. Finally, for the successfully implemented system, the round test and the micro step test results are given.

A Study on the Temperature Characteristics of Main Coolant Pump for System-integrated Modular Advanced Reactor (SMART 원자로용 냉각재 순환펌프의 온도특성에 관한 연구)

  • Gu, Dae-Hyeon;Bang, Deok-Je;Gang, Do-Hyeon;Kim, Jong-In;Jo, Yun-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.320-326
    • /
    • 2000
  • The canned motor of 3-phase induction is used for main coolant pump(MCP). The type of motor is canned-motor that stator and rotor are welded by sealed can. So, cooling water flows in the air gap of the canned motor as an independent cycling cooling system from the air gap to yoke of the motor to prevent high temperature of stator can and to lubricate bearing. Heat exchange is occurred between cooling water in the air gap and cooling water from the exterior pump to prevent rising of temperature in the motor. I has to analyze the characteristics of can exactly because the loss and the heat in the can are very important to design MCP. Therefore, thermal analysis is studied considering the effect of eddy-current los induced in the can.

  • PDF

Study on the Magnetic Field Measurement Using the Ultrasonic Transducer (초음파진동자를 이용한 자계측정방법 연구)

  • 손은영;류주현;윤광희;정영호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.350-355
    • /
    • 1997
  • A new magnetic field measuring system with induced coil is reported. This system consists of air-cared coil that is forced by the ultrasonic transducer. Induction voltage of coil is proportional to the DC magnetic field and the driving frequency of ultrasonic transducer by the principle of Faraday's law. The experimental measuring system is setup, and the possibility of a new magnetic field sensors is confirmed.

  • PDF

Development of Fault-Simulated System for Induction Motors (유도전동기 고장모의 시뮬레이터 개발)

  • Hwang, Don-Ha;Lee, Ki-Chang;Kang, Dong-Sik;Kim, Byong-Kuk;Jo, Won-Young;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.182-184
    • /
    • 2006
  • A down-scaled simulator is developed to simulate typical faults in induction motor such as short-turn stator winding, broken rotor bar, dynamic and static air-gap eccentricity, bearing trouble, and mechanical unbalance. The simulator is used as an initial builder to develop design algorithm for real-time faults detecting system by processing an abnormal signal and characteristics in each fault.

  • PDF

Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor (단상유도전동기의 돌입전류저감을 위한 제어기 설계)

  • Park, Su-Kang;Baek, Hyung-Lae;Lee, Sang-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

Implementation of Under Voltage Load Shedding for Fault Induced Delayed Voltage Recovery Phenomenon Alleviation

  • Lee, Yun-Hwan;Park, Bo-Hyun;Oh, Seung-Chan;Lee, Byong-Jun;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.406-414
    • /
    • 2014
  • Significant penetration of induction motor loads into residential neighborhood and commercial regions of local transmission systems at least partially determine a vulnerability to a fault induced delayed voltage recovery (FIDVR) event. Highly concentrated induction motor loads with constant torque could stall in response to low voltages associated with system faults. FIDVR is caused by wide spread stalling of small HVAC units (residential air conditioner) during transmission level faults. An under voltage load shedding scheme (UVLS) can be an effective component in a strategy to manage FIDVR risk and limit the any potential disturbance. Under Voltage Load Shedding take advantage of the plan to recovery the voltage of the system by shedding the load ways to alleviation FIDVR.

Formation of System Matrix for analyzing Magnetic Equivalent Circuit of Induction Motor (유도전동기의 자기등가회로 해석을 위한 시스템 매트릭스 구성)

  • Choi, Jae-Young;Lee, Eun-Woong;Jeong, Jong-Ho;Kim, Sung-Jong;Woo, Sung-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.330-332
    • /
    • 2000
  • To analyze the transient state of an induction motor, there have been studies for using the magnetic equivalent circuit method(MECD) instead of the time differential finite-element method. MECD which analyzes magnetic equivalent circuits after converting each part of an electric machine into the magnetic circuit elements, has the merits of short calculation-time and comparatively accurate results. To analyze an electric machine with MECM, we have to replace stator and rotor with the magnetic elements and express the air gap, where electromechanical energy conversion takes place, with the permeance. So in this study, to analyze an Induction Motor with HECM, we express the magnetic equivalent circuit as algebraic equations and then as the matrix for solving easily them. In particular, all relations are formed with matrixes to solve Mathematically them in the programming process later. As a result, this theory will be the basis on the static and dynamic analysis of an Induction Motor.

  • PDF

Modeling of inductive power collector for PRT system (PRT 시스템에 적합한 유도 전력 집전 장치의 모델링)

  • Han Kyung-Hee;Lee Byung-Song
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.794-799
    • /
    • 2005
  • In this paper, the inductive power collector using electromagnetic induction for the PRT(Personal Rapid Transit) system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power collector is used for the PRT system, which has a large air-gap and demands a large electrical power capability. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding. which was divided in half to increase both output current and output voltage was suggested. Also, model of power collector and parallel winding structure are presented, in addition, the performance of inductive power collector to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

MODELING OF PRESSURE CONTROL SYSTEM OF BOILER (보일러 풍압 제어 계통의 모델링)

  • Park, Min-Ho;Mok, Hyung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.362-366
    • /
    • 1987
  • The amount of inflowing Air into the boiler has controlled by manipulating the opening of valve, damper and vane, as fan operated by induction motor operats at constant speed, but these control methods are not efficient. Thus VVVf(Variable Voltage Variable Frequency) control of fan has selected to improve efficiency and to acquire power savings. Control system of Air Flow is affected by nonlinearity caused by load variation, vane opening, etc. The analysis of control parameter causing nonlinearity is needed to acquire optimal control and excellent transient response. This paper provides modeling of boiler with various load conditions and vane opening, and analysis of this system.

  • PDF