200 t/d급 MHI 석탄 가스화기의 석탄 및 공기 배분에 따른 가스화 특성 평가 (Influence of coal and air flow rate distribution on gasification characteristics in 200 t/d scale MHI coal gasifier)

  • 도윤영;예인수;김봉근;류창국
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.93-96
    • /
    • 2015
  • Commercial coal gasifiers typically use entrained flow type reactors, but have unique features in terms of reactor shape, gasifying agent, coal feeding type, ash/slag discharge, and reaction stages. The MHI gasifier is characterized as air-blow dry-feed entrained reactor, which incorporates a short combustion stage at the bottom and a tall gasification stage above. This study investigates the flow and reaction characteristics inside a MHI gasifier by using computational fluid dynamics (CFD) in order to understand its design and operation features. For its pilot-scale system at 200 ton/day capacity, the distribution of coal and air supply between the two reaction stages was varied. It was found that the syngas composition and carbon conversion rate were not significantly influenced by the changes in the distribution of coal and air supply. However, the temperature, velocity and flow pattern changed sensitively to the changes in the distribution of coal and air supply. The results suggest that one key factor to determine the operational ranges of coal and air supply would be the temperature and flow pattern along the narrower wall between the two reaction stages.

  • PDF

급기가 되는 이중바닥 구조체의 열 성능 평가 (Estimation of the thermal performance on the double slab floor with supplying air)

  • 차광석;박명식;이대우;남우동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

가변속 왕복동 압축기의 급유 촉진기구 설계 (Design of Oil Supply Enhancement Device for a Variable Speed Reciprocating Compressor)

  • 김현진;이태진
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.25-31
    • /
    • 2003
  • This paper addresses an oil supply enhancement device to resolve a shortage of oil supply or no oil supply at all encountered at low speed operation for a variable speed reciprocating compressor used for household refrigerators. The oil supply enhancement device comprises a moving cylinder attached to the lower end of crankshaft and two of fluid diodes, each one at the inlet and outlet of the cylinder. Up-and-down movement of the cylinder against the lower end of the crankshaft together with the functioning of the two fluid diodes produces net oil flow from oil reservoir to inside the crankshaft. The experiment on the test bench has shown that enough oil supply into the oil feeding hole cu be made by using this device even at low speed range. Some analytical study has also been carried out to under-stand its oil supply mechanism.

클린룸의 상부 플레넘 설계를 위한 유동특성 실험 (Airflow Characteristic Experiments for the Upper Plenum Design of Clean Room)

  • 오명도;배귀남;김석철;이춘식
    • 설비공학논문집
    • /
    • 제1권4호
    • /
    • pp.276-289
    • /
    • 1989
  • The airflow characteristics in both the upper plenum and the clean space of clean room are investigated by measuring the pressure distribution of the upper plenum and the velocity profile in the clean space, at the various conditions of the supplied airflow rate, the volume of upper plenum and the air supply type. The performance of vertical air supply type and horizontal air supply type is analyzed in terms of the airflow uniformity which is frequently used in indicating the clean room performance, and the relations among the volume of upper plenum, the supplied airflow rate and the airflow uniformity are confirmed. The results of this experimental study can be applied to the designing of the upper plenum of clean room.

  • PDF

에너지 절약형 공기압 시스템 특성에 관한 연구 (A Study on the Energy Saving Type Pneumatic System Characteristics)

  • 김형의;김동수;강보식;성백주
    • 연구논문집
    • /
    • 통권25호
    • /
    • pp.91-98
    • /
    • 1995
  • Recently, improving the energy efficiency of a pneumatic system and reducing the consumption of compressed air were a concern of scholars at domestic and abroad. The using fields of a pneumatic system are widely used in factory automation of manufacturing line, chemical factories with explosiveness danger and petroleum industries etc. In particular, pneumatic cylinder is applied to feeding work of workpiece. jig tools and press mechanism, reciprocation and rotary motion with rack and pinion. In this study, the experimental apparatus consisted to pneumatic cylinder, dual supply pressure regulator and solenoid valve. The dual supply pressure regulator connected to outlet port of solenoid valve. The supply pressure($4.5kg_f/cm^2$) of compressed air goes into the rodless chamber 1 to drive the piston rod forward which is named working stage. The supply pressure ($2kg_f/cm^2$) of compressed air goes into the rod chamber 2 to drive the piston rod backward which is named no-working stage. Accordingly, the research results of this study can be obtained to Energy-Saving Effects of the compressed air about 35%.

  • PDF

기계 환기시스템의 실내 환기성능 특성 해석에 관한 연구 (A Study on Characteristic Analysis for Indoor Ventilation Performance of Mechanical Ventilation System)

  • 구재현
    • 한국가스학회지
    • /
    • 제16권2호
    • /
    • pp.31-37
    • /
    • 2012
  • 본 연구는 실내 쾌적성 제어를 위하여 룸 에어컨의 환기성능을 분석한다. 실험장치는 환경공조챔버, 룸 에어컨, 추적가스 측정시스템, 급기팬과 제어기로 구성된다. 환기성능은 ASTM Standard E741-83 기준에 근거하여 환경공조챔버 내 CO2 추적가스기법을 사용한 체강법에 의해 재실자와 급기 환기량에 따라 평가된다. 급기 환기량 증가에 따라 환기성능이 증가함을 파악하였으며 재실자가 없는 경우 CO2 가스는 빠르게 감소하며 이때의 환기성능은 55%까지 증가한다. 그리고 1명의 재실자가 있는 경우 1시간 경과후 급기량 570 lpm에서 환기성능은 자연감쇠와 비교하여 25%까지 증가한다. 실험 데이터를 사용하여 환경공조챔버 내 룸 에어컨의 환기성능 모델링을 도출하였다.

공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구 (Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires)

  • 김병준;양영;신원규
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.78-86
    • /
    • 2020
  • 본 연구에서는 공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관하여 수치해석을 수행하였다. 수치해석을 통해 댐퍼의 급기량과 방화문에서의 방연풍속의 관계식을 선형적으로 나타내었고 국가화재안전기준인 방연풍속 0.7 m/s를 만족하는 댐퍼의 최소유량을 선정할 수 있었다. 댐퍼의 최소유량을 적용하여 댐퍼의 급기 방향과 설치 높이에 따라 방연속도를 분석하였다. 댐퍼의 급기 방향이 상향인 경우와 댐퍼가 높게 설치되었을 때 댐퍼의 급기 방향이 하향인 경우보다 방화문 상부에서 더 큰 방연풍속을 나타내었고 누출된 연기 농도가 더 낮은 것을 확인할 수 있었다. 따라서 방화문 상부에서 큰 방연풍속을 확보하는 것이 제연에 더 효율적일 것으로 판단된다.

주택 대변기용 상수에 대한 우수대체 효과에 따른 연구 (The Study on the Effect of Exchanging Water Supply on the Rainwater in Closet of Detached House)

  • 조성우
    • 설비공학논문집
    • /
    • 제21권4호
    • /
    • pp.209-214
    • /
    • 2009
  • The purpose of this study is to investigate the effect exchanging water supply on the' rainwater in detached house. It is difficult to decide water supply amount for a closet in detached house, Therefore, to obtain water supply for closet in detached house, it used regression equation using 1,569 data of frequency of used closet and during 120 days. In detached house, the frequency of used closet is 14.6 times/day and water supply amount is $219 {\ell}/day$. The optimum rainwater tank size which is decided by regression equation and using weather data is $8.5\;m^3$. The effect exchanging water supply on the rainwater in detached house is up 50%.

치과용 고속 에어터빈 핸드피스의 공급관로 분석 및 성능평가 (Supply Route Analysis and Performance Evaluation of Dental High-Speed Air Turbine Handpiece)

  • 한명철;김정관;최명욱
    • 한국정밀공학회지
    • /
    • 제28권1호
    • /
    • pp.80-88
    • /
    • 2011
  • The dental high-speed air turbine handpiece is one of the most popular devices that have been widely used as the main means of cutting tooth structure and restorative material in dentistry. In consideration of usage and marketability of the dental handpiece, it is obviously worthy of investigating it. The goal of this paper is to establish the relationship between the air turbine speed and the supply route inside the handpiece. To do this, the Computational Fluid Dynamics(CFD) tool, Fine$^{TM}$/Turbo is used and the optimal supply route position is suggested from the simulation results. In addition, as an attempt for domestic product, the reverse engineering process of a high speed dental handpiece by 3D X-Ray CT equipment and wire cutting is presented for the Mark II model in NSK. In doing so, the 3D modeling of the handpiece parts is carried out with CATIA V5, and the interference between parts is examined. Finally, the result of performance test for the prototype produced in this research is presented.

마이크로 관류수차의 상수도 관로시스템 적용에 관한 연구 (Application of Micro Cross-Flow Turbine to Water Supply System)

  • 최영도;쿠로카와준이치
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.36-43
    • /
    • 2006
  • Recently, micro hydropower and it's useful utilization are taking a growing interest as a countermeasure of global worming by carbon dioxide and exhaustion of fossil fuel. The purpose of this study is to investigate the possibility of extracting micro hydropower wasted by a valve in water supply system using micro cross-flow hydraulic turbine. In order to fulfill the functions of controlling flow rate and pressure in substitute for the valve, air and water are supplied into an air suction hole which is installed on the side wall of micro cross-flow hydraulic turbine. The results show that in case of supplying a lot of air into the air suction hole, about 50% of flow rate and relatively high value of loss coefficient are controlled by the turbine. Moreover, including high possibility of applying the micro cross-flow turbine to water supply system, extended application of the turbine to the water discharge system of drainage and irrigation canal.