• Title/Summary/Keyword: Air Force

Search Result 1,948, Processing Time 0.027 seconds

Effect of Aircraft Noise of the Air Force on Noise Sensitivity, Psychosocial Status and Behaviour of Elementary Students (공군 항공기 소음이 초등학생의 소음 민감도, 정서 및 행동에 미치는 영향)

  • Oh, Won-Ki;Kim, Hyeong-Su;Chang, Sung-Hoon;Lee, Kun-Sei;Kim, Keun-Whoe;Choi, Hee-Jung;Ham, Eun-Mee;Son, Ju-Hyoung
    • Journal of agricultural medicine and community health
    • /
    • v.33 no.3
    • /
    • pp.279-291
    • /
    • 2008
  • = ABSTRACT =Objectives : We evaluated the effect of the aircraft noise on the behavior and affect status of the local elementary school students. Methods : The daytime noise levels of the exposed and control areas were compared and the self answered questionnaires from 272 students and their parents of the exposed area and 91 of the control area were collected. The questionnaires are regarding the noise sensitivity and the psychosocial status of the students, noise sensitivity of the parents and the parents' behavioral evaluation for their children. Results : The mean noise level of the exposed area (67.6 dB(A)) showed higher level than the control area (57.1 dB(A), 58.2 dB(A), 60.2 dB(A)) and it was statistically significant. The mean score for noise sensitivity and the mean score for brief mental exam. in the exposed students were lower than the mean scores in the control group but they were not statistically significant (p=0.056 & 0.165). The mean score for behavioral evaluation of students by their parents in the exposed area(15.5) was higher than the mean score in the control group(13.2) and it was statistically significant(p=0.043). The mean score for noise sensitivity in the exposed parent(27.5) was higher than the mean score in the control group(24.1) and it was statistically significant(p=0.045). Conclusions : This study revealed that the noise sensitivity of the parents affected the behavioral evaluation of the students than noise-exposure itself. The further study is needed to evaluate relationship between aircraft noise and it's effect on children's health.

Effects of 8 Weeks Resistance Training on Nitric Oxide (NO) Concentration and Mean Arterial Pressure (MAP) in Young Men (건강한 젊은 성인에서 8주 규칙적인 저항성 트레이닝이 산화질소(NO) 농도와 평균동맥압(MAP)에 미치는 영향)

  • Kim, Young-Il;Paik, Il-Young;Kwak, Yi-Sub;Kim, Keun-Soo;Woo, Jin-Hee
    • Journal of Life Science
    • /
    • v.19 no.5
    • /
    • pp.625-632
    • /
    • 2009
  • The purpose of this study was to examine the effect of exercise training on nitric oxide (NO) levels, mean arterial pressure (MAP), blood pressure (BP), and heart rate (HR) in college students. 5 subjects were randomly assigned to two experimental groups; an aerobic training group (ATG) and a resistance training group (RTG). In aerobic training, based on measured maximum oxygen consumption rate, 70% exercise intensity was applied and conducted for 60 min. In resistance training, 70% of 1-RM was performed for 90 min. Blood sampling was conducted 3 times during resting state, post-exercise, and after 30 minutes of recovery. The results are as followed. For the post training values of $VO_2max$, % body fat and MAP, there were significant differences in the ATG compared to pre training (p<0.05). However, there were no differences in the RTG between pre and post training. NO increased post training, during rest and at the end of exercise compared to pre training in the ATG (p<0.05). Also, the HR decreased in post training at the end of exercise (p<0.05), however, there were no significant differences in SBP and DBP between pre and post training in the ATG. The HR, SBP and DBP did not change at all in post training compared to pre training in the RTG. In conclusion, an increase in the production of Nitric Oxide (NO) concentration and $VO_2max$, decrease of body fat% and physiological variables (HR, BP, MAP) were shown to be more effective in aerobic training (AT) than resistance training (RT).

Study on Bullet-Proof Performance of Multi-Layered Hybrid Armor Against 9mm FMJ Projectile (9mm 권총탄 위협을 받는 적층구조의 방탄성능 연구)

  • Lee, Jong-Gu;Kim, Siho;Kim, Gunin;Cho, Maenghyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.6
    • /
    • pp.487-495
    • /
    • 2012
  • In order to prevent the high velocity bullet from penetration, aluminum alloy and RHA(Rolled Homogeneous Armour) steel, which have a high tensile and compressive strength, are usually used as the bullet-proof armor material. Although these materials have a good bullet proof performance, but not an area density which is a weight increasing factor of bullet-proof armor. Therefore, Mg(magnesium) alloy is a promising substitute for the traditional bullet-proof armor material due to the relatively low areal density. The spatial efficiency of Mg alloy, however, is inferior to the traditional material's, which is a volume(thickness) increasing factor of bullet-proof armor. In this study, we select the multi-layered hybrid armor which consist of Ceramic, with a high strength; Mg alloy, with a low areal density; Kevlar, with a high tensile strength-to-weight ratio; in order to make up for the poor spatial efficiency of Mg alloy. By predicting V50 of the multi-layered armor against 9mm FMJ(Full Metal Jarket). we show that the multi-layered armor have the capability in improving bullet-proof performance in the respect of the areal density, but also the spatial efficiency.

A Study of Surface Electromyography Measurement of Facial Muscles in Normal Person (정상인의 안면부 운동 시 표면근전도 측정 연구)

  • Lee, Hyung Geol;Jung, Da Jung;Choi, Yoo Min;Kim, Suk Hee;Yook, Tae Han;Song, Beom Yong;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.31 no.2
    • /
    • pp.51-63
    • /
    • 2014
  • Background or Objectives : The purpose of this study is to measure surface Electromyography(sEMG) of facial muscles in normal person and to find method for standardizing of sEMG's value. Methods : We measured 3points on face, frontalis muscle($GB_{14}$), zygomaticus muscle($SI_{18}$), orbicularis oris muscle($LI_{19}$) of 40 normal person by sEMG. 40 normal person consist with two groups, each 20 male, 20 female. Average age of subject was $26.50{\pm}4.79$. SEMG instrument QEMG-4 XL was used. After training exercise of facial muscles, sEMG's root mean square value was measured once. Results : 1. In whole experimental group, frontalis muscle's both side average was $78.36{\pm}40.87$, zygomaticus muscle's both side average was $84.70{\pm}49.81$, orbicularis oris's both side average was $104.83{\pm}38.81$. 2. Left side of Frontalis muscle, both side of zygomaticus muscle are high marked in male than female in statistically. 3. In whole experimental group, average of ratio comparing smaller value with bigger value in difference between left side and right side was $19.60{\pm}12.88$ %. 4. Average of asymmetry index(AI) was $11.46{\pm}8.36$ %. orbicularis oris muscle's average of AI had least difference was $8.95{\pm}7.50$ %. zygomaticus muscle's average of AI had most difference was $13.95{\pm}8.90$ %. Conclusions : The result of this study could provide useful information of field of sEMG is used in oriental medicine treatment of facial muscles. To assess efficacy of treatment in facial muscles, we need to standardize facial muscle's sEMG values by using AI, ratio comparing values and etc.

Response Characteristics of the PZT Transducers during Glass Capillary Breakage (유리모세관 파괴시 방출된 탄성파에 대한 PZT 변환기의 응답특성)

  • Lee, Jong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.1
    • /
    • pp.33-41
    • /
    • 1998
  • The response characteristics of the PZT transducers during glass capillary breakage were studied at the epicenter of the glass plate. The PZT transducers had been made by using EC-65 PZT ceramics(supplied by Edo co.) with a constant area and a various thickness. The theoretical displacement and velocity at the epicenter of glass plate with an air boundary condition were calculated by assuming the point load of 1N force strength and a rise time of 280 ns with a ramped functional dependence, and the 1st pulses of the PZT transducer may be considered as the vertical velocity incident on the electrode of the PZT ceramic. The responses of the PZT transducer may be depended on the thickness mode of the PZT ceramic below 0.33 in the ratio of the thickness to the diameter of PZT ceramic, but the reponse of the PZT transducer may be depended on the other modes of PZT transducer in the addition of the thickness mode of the PZT ceramic above 0.33. The full time of half maximum at the 1st pulse was nearly 280 ns without a variation of applied breakage load and the resonant frequency of the PZT transducer, and then may be considered as the rise time of a AE source. The maximum amplitude of the 1st pulse depended on the incident vertical velocity and capacitance of the PZT transducer. Therefore, the full time of half maximum and maximum amplitude of the 1st pulse may be considered as the rise time and strength of acoustic emission source respectively.

  • PDF

Vibration Modeling and Optimal Design of Differential Electromagnetic Transducer for Implantable Middle Ear Hearing Devices using the FEA (FEA를 이용한 이식형 인공중이용 차동전자 트랜스듀서의 진동 모델링과 최적 설계)

  • Kim Min-Kyu;Lim Hyung-Gyu;Han Chan-Ho;Song Byung-Seop;Park Il-Yong;Cho Jin-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.7
    • /
    • pp.379-386
    • /
    • 2005
  • Among various kinds of hearing aids which have been developed so far. the conventional air conduction hearing aids have some problems such as the acoustic distortion, an howling effect due to acoustic feedback. Another type of hearing aid. the cochlear implant system can be applied to the profound imparied person. However. it shows the disadvantage that there is no possibility of recovery of the acoustic organ such as ossicle. On the other hand. the implantable middle ear heaving device directly vibratos the ossicular chain and has better sound qualify. good cosmetics for appearance. and wide frequency responses so that it can overcome the defects or the conventional hearing aids. In this paper, a mathematical modeling and a momentum equation derivation of the DET has been performed. For the optimization of the structure dimension generating maximal vibrating force of the DET. the computer simulation using a finite element analysis (FEA) software has been performed. Also. the vibrating transducer has been designed to make the frequency characteristics or the transducer be similar to those of the normal middle ear. Through the experimental results, the measured vibration characteristics of the DET has been evaluated to verify the performance for the application to implantable middle ear hearing devices.

Characteristics of the E- and F-region field-aligned irregularities in middle latitudes: Initial results obtained from the Daejeon 40.8 MHz VHF radar in South Korea

  • Kwak, Young-Sil;Yang, Tae-Yong;Kil, Hoysub;Phanikumar, Devulapalli Venkata;Heo, Bok-Haeng;Lee, Jae-Jin;Hwang, Junga;Choi, Seong-Hwan;Park, Young-Deuk;Choi, Ho-Seong
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.1
    • /
    • pp.15-23
    • /
    • 2014
  • We present preliminary observations of the field-aligned-irregularities (FAIs) in the E and F regions during the solar minimum (2009 - 2010) using the 40.8 MHz coherent backscatter radar at Daejeon ($36.18^{\circ}N$, $127.14^{\circ}E$, $26.7^{\circ}N$ dip latitude) in South Korea. The radar, which consists of 24 Yagi antennas, observes the FAIs using a single beam with a peak power of 24 kW. The radar has been continuously operated since December 2009. Depending on the manner of occurrence of the backscatter echoes, the E-region echoes are largely divided into two types: quasi-periodic (QP) and continuous echoes. Our observations show that the QP echoes occur frequently above an altitude of 105 km in the post-sunset period and continuous echoes occur preferentially around an altitude of 105 km in the post-sunrise period. QP echoes appear as striated discrete echoes for a period of about 10 - 20 min. The QP-type echoes occur more frequently than the continuous-type echoes do and the echo intensity of the QP type is stronger than that of the continuous type. In the F region, the FAIs occur at night at an altitude interval of 250 - 450 km. As time proceeds, the occurrence height of the FAIs gradually increases until early in the morning and then decreases. The duration of the F-region FAIs is typically a few hours at night, although, in rare cases, FAIs persist throughout the night or appear even after sunrise. We discuss the similarities and differences of the FAIs observed by the Daejeon radar in comparison with other radar observations.

A Fundamental Study of Eu2+ Luminescence in Aluminum Borate Compounds (Aluminum Borate 화합물에 있어서 EU2+이온의 발광성)

  • Chang, Ki-Seog
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.350-355
    • /
    • 2000
  • The compounds, CaAl$_2$(BO$_3$)$_2$O, SrAl$_2$(BO$_3$)$_2$O and BaAl$_2$(BO$_3$)$_2$O, are good host lattices for highly efficient $Eu^{2+}$ luminescence. The europium emission peaks at 450 nm in $Eu^{2+}$:CaAl$_2$(B0$_3$)$_2$O, 411 nm in $Eu^{2+}$: SrAl$_2$(BO$_3$)$_2$O and 375 nm in $Eu^{2+}$: BaAl$_2$(BO$_3$)$_2$O. The $Eu^{2+}$: CaAl$_2$(BO$_3$)$_2$O Phosphor shows a high output and should be a good maintenance in VUV Xe lamps. It is ideally suited for use in PDP phosphors. The $Eu^{2+}$ ion is interesting because the Stokes shift emission is a strong host dependent. The difference in the Stokes shift is oneimportant factor leadingto a difference in wavelength. If the 5d level of $Eu^{2+}$ ion is lower in energy,according to a decrease in the doping lattice size, then the emission wavelength will be longer and the Stokes shift will be smaller. Therefore, a knowledge of the relationship between the crystal lattice size and the Stokes shift. (orthe energy of the 5d level),is essential for beingable to predict $Eu^{2+}$ emission properties.

  • PDF

Human Exposures to Various Electromagnetic Forces : Measurement of Electromagnetic Force for Future Epidemiological Study (각종 전자파에 의한 인체의 노출 : 역학조사를 위한 전자파 측정)

  • Kim, Deok-Won;Ryu, Chang-Yong;Yoon, Hyung-Ro
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.191-200
    • /
    • 1995
  • Although air, water, and noise pollutions have been widely recognized, electromagnetic forces (EMF) hazard has been rarely recognized as a pollution and very little studies has been done in this country. Thus, in this study electromagnetic forces radiated by various home appliances, office machines, and communication equipments were measured and so were several places radiating strong EMF such as subway stations and electric substations. Among the home appliances microwave oven radiates lots of magnetic field and microwaves, and electric mattress does strong magnetic field. In video game room strong magnetic and considerable electric fields were measured. It was observed strong magnetic field inside of electric powered train and very strong magnetic and electric fields on some platforms. Hand-phone and car-phone radiate very hazardous level of microwaves to brain and that they rapidly come into wide use. In this study data base for various electric machines and places radiating strong EMFs were constructed and could be used for future epidemiological studies.

  • PDF

Oxygen Transfer System in Biological Fluidised Bed Using the Deep Shaft as Aeration Device (생물학적(生物學的) 유동층(流動層)을 이용(利用)한 폐수처리(廢水處理)에 있어서의 심층(深層) 폭기장치(曝氣裝置)에 의한 산소전달(酸素傳達) 시스템)

  • Kim, Hwan Gi;Ahn, Song Yeob;Jeong, Tae Seop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.13-24
    • /
    • 1988
  • This paper is concentrated on the development of oxygen transfer system by U-tube deep shaft in biological fluidised bed process. The depth of the shaft is 32 m, it is composed of downcomer and riser. Not only flow pattern and oxygen transfer in the deep shaft but also oxygen limitation in biofilm and oxygen utilization in biological fluidised bed are investigated. In this investigation, driving force for liquid circulation in the deep shaft is affected by air injection depth and gas hold-up in downcomer. Flow pattern of the deep shaft is revealed to plug flow. When flow velocity in the deep shaft is maintained to 0.52 m/sec, $K_La$ value is peak at 25~30 m depth in riser. The efficiency of dissolved oxygen supply which passed from the deep shaft to biological fluidised bed is estimated to 56~81 % in the organic wastewater treatment using the deep shaft and when dissolved oxygen concentration is 9.2 mg/l and over, limiting factors of flux and substrate within biofilm are organic materials. Terefore, organic loadings could be increase without decreasing of BOD removal efficiency.

  • PDF