• 제목/요약/키워드: Aging Measurement

검색결과 466건 처리시간 0.036초

OLED 패널의 노화 측정 및 보상 (Aging Measurement and Compensation for OLED Panel)

  • 정경중;정홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1009-1010
    • /
    • 2008
  • This paper presents a real-time aging measurement and feasible compensation system for the prolonged lifetime of OLED panel. The proposed system is composed of four parts, a PC with a man-machine interface, a measurement block, an adaptive amplifier block, and a compensation block. We apply a tree algorithm for less complexity and convenience of measurement on the degree of aging. An adaptive multi-stage differential amplifier is also implemented to deal with a various range of input voltages at the same spot.

  • PDF

HFPD 패턴분석을 이용한 절연열화 진단 (Insulation Ageing Diagnosis Using HFPD Pattern Analysis)

  • 김덕근;여인선;임장섭;이진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1726-1728
    • /
    • 2003
  • The aging diagnosis method using partial discharge measurement detects discharge signals that critical cause of failure in insulation material operated a long time and can diagnose aging state of insulation materials with an aging analysis algorithm. The HFPD measurement method is a technique to analyze aging state of high voltage insulation materials and detect higher frequency signals than conventional PD measurement method therefore it takes less noise effect and could execute active line measurement. It is possible to analyze main discharge phenomena and obtain access to aging progress occurred in insulation materials through accumulation of HFPD signals during determined interval and expression of fractal dimension using statistical process of accumulated signals. The HFPD signals that occurred in each applied voltages are measured during 180 cycles and accumulated to the same phase of one cycle. These patterns that made by previous method are normalized with logarithm function and than inputted to neural networks. The aging diagnosis of insulation material was possible and the recognition ratio of neural network appeared very high.

  • PDF

고체 합성수지절연체와 표면노화 진단기술로서의 부분방전 측정평가기술에 대하여 (Partialt Discharge Measurement Techniques for Diagnosis of Surface Aging on Organic Insulation)

  • 박완기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.50-56
    • /
    • 1994
  • Partial discharge on organic insulation surfaces are an important sauce of aging. Furthermore the modern PD measurement technigues are rapid developed as quality control and diagnostic tests to determine the fitness for use of HV equipment employing sol id electrical insulation. This paper deals with theory of conventional PD measurement and new tendency of technical development on PD measurements und evaluations. Finally the Measuring system used for diagnosing the surface aging on the organic insulation at High Voltage Laboratory of Technical University of Darmstadt in Germany is presented.

  • PDF

CV케이블의 부분방전 신호를 통한 열화과정의 정량적 진단 (Normalization Diagnosis of Aging Process on Partial Discharge Signals of CV Cable)

  • 소순열;임장섭;김진사;이준웅;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.451-455
    • /
    • 1997
  • The partial discharge has been blown as the chief breakdown of power equipments. The analysis and the recognition is much difficult because the partial discharge signal is very small and has complex aging pattern. Recently, insulation aging diagnosis based on pattern of phase(Ф), partial discharge magnitude(q), number(n) has been very important. Owing to depreciate the reappearance of aging progress at the electrical tree pattern and to be difficult to analyze visually, the study on partial discharge pattern is suggested to normalizing analysis method of partial discharge signals. This parer is purposed on prediction of life-time measurement of cv-cable, on decision of risk degree with normalization and real-time measurement of partial discharge signals for aging diagnosis of cv-cable. As normalizing the aging signals of electrical tree in cv-cable, it is able to confirm risk degree of insulation material with the distribution of Ф-q-n and recognize the process of aging pattern using neural network.

  • PDF

Jerk 함수를 적용한 태양광 스트링 내의 노후화 모듈 검출 기법 (Detection of Aging Modules in Solar String with Jerk Function)

  • 손한별;박성미;박성준
    • 전력전자학회논문지
    • /
    • 제24권5호
    • /
    • pp.356-364
    • /
    • 2019
  • In this study, major problems, such as licensing problems due to civil complaints, deterioration of facility period, and damage of modules, are exposed to many problems in domestic businesses. Particularly, the photovoltaic (PV) modules applied to early PV systems have been repaired and replaced over the past two decades, and a new module-based aging detection method is needed to expand the maintenance market and stabilize and repair power supplies. PV modules in a PV system use a string that is configured in series to generate high voltage. However, even if only one module of the solar modules connected in series ages, the power generation efficiency of the aged string is reduced. Therefore, we propose a topology that can measure the instantaneous PV characteristic curve to determine the aging module in the solar string and the aging judgment algorithm using the measured PV characteristic curve.

용존산소활량 측정용 지르코니아 갈바니 센서 (Zirconia galvani sensor for the measurement of oxygen activity)

  • 오영제
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.441-448
    • /
    • 2009
  • Magnesia partially stabilized zirconia(Mg-PSZ) solid electrolytes for an improvement of thermal shock resistance, which is suitable for the measurement of oxygen activity in a molten steel, were prepared by post-thermal aging treatment. The steelmaking oxygen sensor elements were formed by an injection molding method, sintered at $1650^{\circ}C$, and then thermal aged ranged from 1250 to $1400^{\circ}C$. Sintered density and porosity were decreased as increasing the magnesia content in a zirconia-magnesia solid solution. Fractions of cubic phase to the synthesized Mg-PSZ solid electrolytes were ranged from 13.13 to 79.54.% after post-thermal aging treatment. Very dense microstructure without voids in the grains was obtained by the post-thermal aging process. Fine tetragonal phase crystallites precipitated on the cubic surface during post-thermal aging up to $1300^{\circ}C$ improve a thermal shock resistance and reappearance of electro motive force(EMF) curve.

지중 배편케이블의 열화에 미치는 온수의 영향 (Effects of Hot Water on the Aging of URD Power Cables)

  • 한재홍;송일근;김주용;이병성;정종욱
    • 한국전기전자재료학회논문지
    • /
    • 제15권7호
    • /
    • pp.609-614
    • /
    • 2002
  • In this study, we investigated the effects of hot water on the aging of URD power cables due to the hot water ingress to power distribution lines. Hot water contacted and non-contacted cables extracted from 2 distribution lines were characterized by the measurement of oxidation induction time(OIT) and chemical structure. In OIT measurement, hot water contacted cables showed the shorter OIT than non-contacted ones. Especially, hot water contacted insulation layer near insulation shield showed the shortest OIT. In chemical structure analysis, the antioxidant content was decreased and the acid concentration was increased by hot water ingress. From this results, it can be concluded that the hot water ingress to power cable may be accelerate the aging by means of antioxidant consumption.

Development of Aging Diagnosis Device Through Real-time Battery Internal Resistance Measurement

  • Kim, Sang-Bum;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권2호
    • /
    • pp.129-135
    • /
    • 2022
  • Currently, the rapid growth of electric vehicles and the collection and disposal of waste batteries are becoming a social problem. The purpose of this paper is to propose a fast and efficient battery screening method through a safe inspection and storage method according to the collection and storage of waste batteries of electric vehicles. In addition, as the resistance inside the waste battery increases, an instantaneous voltage drop occurs, and there is a risk of overcharging and overdischarging compared to the initial state of the battery. Accordingly, there are great difficulties in operation, so the final goal of this study is to develop a device for diagnosing aging through real-time battery internal resistance measurement. Final result As a result of simulation of the internal resistance measurement test circuit through external impedance (AC), the actual simulation value was 0.05Ω, RS = Vrms / Irms => Vrms = 8.0036mV, Irms = 162.83Ma. Substitute the suggested method. The result was calculated as Rs = 0.0495Ω. It is possible to measure up to 64 impedances inside the aging diagnostic equipment that enables real-time monitoring of the developed battery cells, and the range can be changed according to the application method.

BD-R 장기보존 특성 평가를 위한 가속 열화 실험 조건과 안정성 평가 기준에 관한 연구 (A Study on Suitable Condition of Accelerated Aging Test and Evaluation Criteria of Data Stability for Archival Performance Analysis of BD-R media)

  • 이관용;박선주;김도현;조이형;김영주
    • 정보저장시스템학회논문집
    • /
    • 제10권1호
    • /
    • pp.7-13
    • /
    • 2014
  • The Blu-ray Disc Recordable(BD-R) is one of strong candidates for archival application among optical media formats, because of its large capability. However, the well-defined accelerated aging test conditions and evaluation criteria have not yet been fully confirmed for BD-R. In this study, the data stability and degradation aspect of BD-R were analyzed by the random-symbol error rate(R-SER) measurement after the accelerated aging test. And a reasonable test condition of accelerated aging for BD-R and the appropriate evaluation criterion using R-SER measurement were discussed.

가속열화시험에 의한 18kV ZnO 피뢰기의 누설 전류 특성 분석 (Leakage Current Characteristics of 18kv ZnO Lightning Arresters by Accelerated Aging Test)

  • 김주용;송일근;김찬영;문재덕
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.62-67
    • /
    • 2002
  • This paper provides the results of accelerated aging test of 18kV ZnO lightning arresters to investigate the leakage current characteristics. It was impossible to establish the replacement criterion for field operating lightning arrester because conventional aging test was only focused on the aging of ZnO elements. In general, it is possible to replace the aged arresters before the failure in the field using the leakage current measurement because it must be increased by the aging. But we can not use the method because we don't know the characteristics of the installed lightning arresters. Therefore in this paper we applied operating voltage and accelerating cycle which consists of temperature and humidity to the arresters. Then we measured the variation of total and resistive leakage current and found out the characteristics of the acted lightning arresters.