• Title/Summary/Keyword: Advanced Dentistry

Search Result 1,058, Processing Time 0.036 seconds

Effect of sintering programs and surface treatments on monolithic zirconia

  • Seren Nur Dokuzlu ;Meryem Gulce Subasi
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.25-37
    • /
    • 2024
  • PURPOSE. To investigate the effect of sintering programs and surface treatments on surface properties, phase transformation and flexural strength of monolithic zirconia. MATERIALS AND METHODS. Zirconia specimens were sintered using three distinct sintering programs [classic (C), speed (S), and superspeed (SS)] (n = 56, each). One sample from each group underwent scanning electron microscopy (SEM) and grain size analysis following sintering. Remaining samples were divided into five subgroups (n = 11) based on the surface treatments: control (CL), polish (P), glaze (G), grind + polish (GP), and grind + glaze (GG). One sample from each subgroup underwent SEM analysis. Remaining samples were thermally aged. Monoclinic phase volume, surface roughness, and three-point flexural strength were measured. Monoclinic phase volume and surface roughness were analyzed by Kruskal-Wallis and Dunn tests. Flexural strength was analyzed by two-way ANOVA and Weibull analysis. The relationships among the groups were analyzed using Spearman's correlation analysis. RESULTS. Sintering program, surface treatment, and sintering × surface treatment (P ≤ .010) affected the monoclinic phase volume, whereas the type of surface treatment and sintering × surface treatment affected the surface roughness (P < .001). Type of sintering program or surface treatment did not affect the flexural strength. Weibull analysis revealed no significant differences between the m and σo values. Monoclinic phase volume was positively correlated with surface roughness in the SGG and SSP groups. CONCLUSION. After sintering monolithic zirconia in each of the three sintering programs, each of the surface treatments can be used. However, for surface quality and aging resistance, G or GG can be recommended as a surface finishing method.

Assessment Methods for Problematic Eating Behaviors in Children and Adolescents With Autism Spectrum Disorder

  • Miji Lee;Seolha Lee;Jong-Woo Sohn;Ki Woo Kim;Hyung Jin Choi
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.35 no.1
    • /
    • pp.57-65
    • /
    • 2024
  • Autism spectrum disorder (ASD) can be associated with eating problems. However, currently, there is a lack of established guidelines for assessing and addressing eating behaviors in individuals with ASD. This gap in research exists due to the challenges associated with using traditional assessment methods, which may lead to discrepancies in responses and unintentional potential biases from caregivers. In this review, we provided a comprehensive overview of various eating behaviors commonly observed in individuals with ASD. These behaviors include 1) food neophobia, 2) selective eating, 3) binge eating, 4) food avoidance, 5) chewing and swallowing problems, 6) pica, 7) rumination, 8) rituals, and 9) problematic behaviors. Furthermore, we provide a perspective of utilizing digital tools: 1) augmentative and alternative communication; 2) ecological momentary assessment; and 3) video analysis, behavioral analysis, and facial expression analysis. This review explores existing assessment methods and suggests novel assessment aiding together.

Effect of different pattern size and pattern shape on castability of commercially pure titanium (납형의 크기와 형태가 티타늄의 주조성에 미치는 영향)

  • Seo, Yoon-Jeong;Oh, Gye-Jeong;Lee, Hyo-Il;Shin, Yoo-Jin;Kim, Hong-Joo;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.261-268
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effect of geometrically different wax pattern shapes and sizes on the castability of Grade2 Cp-Ti (commercially pure titanium). Materials and methods: Total of 40 mesh wax pattern ($61mm{\times}24mm$, 207 grids), ($61mm{\times}17mm$, 138 grids) was cast in this experiment. Depending on the geometrical shape of the wax pattern, 8 groups was organized; Flat, Semicircular, Horse-shoe and V-shape, each consisting 5 samples. Runner-bar sprue was used in all patterns. The number of completely cast grid in wax pattern served as a measure for the castability of comercially pure titanium. Results: The mean value of square count in each group was as followed; 133.20 squares in group SS (96.52%), 132.40 squares in group SH (95.94%), 132.00 squares in group SF (95.65%), 127.60 squares in SV (91.43%), 198.60 squares in group LF (95.94%), 197.80 squares in group LV (95.56%), 196.40 squares in group LS (94.88%), and 188.00 squares in group LH (90.82%). Conclusion: Within the limitations of this study the results indicate that there were no sttistically significant difference in castability of titanium regarding wax pattern shape (P>.05). However, Small size wax patterns were showing the noticeable castability more than Large size pattern.

Position of maxillary central incisor and intercanine width in Korean adults (한국 유치악 성인의 상악 중절치 위치 및 견치간 거리에 관한 연구)

  • Yang, Dong-Hun;Lee, Jee-Yun;Ban, Jae-Sam;Oh, Gye-Jeong;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.147-152
    • /
    • 2013
  • Purpose: The aim of this study was to propose the position of maxillary anterior teeth and intercanine width measurements based on the incisive papilla in accordance with the cephalic type and gender of dentate Korean adult with normal teeth alignment. Materials and methods: 42 students with Class I normal occlusion, without crowding or spacing, were selected from the Chonnam National University School of Dentistry. The lateral skull radiographs of the subjects were taken and were classified as different cephalic types, based on their PFH / AFH ratios. 42 casts of their maxilla were prepared and both the distance between the upper central incisors and the middle of the incisor papilla was measured with a vernier caliper (A) and the distance between the maxillary canine cusp tips (B) were measured. Statistical analysis was performed using SPSS version 15 and their significance was investigated. Results: For dolichocephalic group, the mean values for A and B were 8.43 (SD: 0.61) and 36.73 (SD: 2.17), respectively. The mean value for A was 8.51 (SD: 1.27) for the mesocephalic group and 8.76 (SD 1.03) for the brachycephalic group. The mean value for B was 35.91 (SD: 1.86) for the mesocephalic group and 37.34 (SD: 2.23) for the brachycephalic group. For the male group, the mean A value was 8.86 (SD: 1.04) and the mean B value was 37.60 (SD: 0.24). For the female group, the mean A value was 8.41 (SD: 0.93) and the mean B value was 36.18 (SD: 2.01). The difference between male and female group in A values were not statistically significant (P>.05). The B values of the male subjects were greater than those of the female subjects and was statistically significant (P<.05). Conclusion: 42 students with normal dentition and occlusion in korea, the distance from the incisive papilla and the incisal edge of maxillary central incisors had no difference in cephalic type or gender. However, the distance between the cusp tip of both canines had significant difference in gender where the male showed higher values than the female, while having no difference in cephalic types.

Stress distribution in bone surrounding maxillary molar implants under different crown-to-fixture ratio: A 3D FEM analysis (치관/고정체 비에 따른 상악 구치부 임플란트 주변골의 응력 분포에 대한 3차원 유한요소법적 분석)

  • Park, Jong-Chan;Shin, Sang-Wan;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.479-489
    • /
    • 2008
  • Statement of the problem: Under anatomical limitations on maxillary posterior region, a poor crown-to root ratio acting on dental implants can result in undesirable stress in surrounding bone, which in turn can cause bone defects and eventual failure of implants. Purpose: The purpose is to compare stress distribution due to different crown-root ratio and effect of splinting between natural teeth and implants in maxillary molar area under different loads. Material and methods: Analysis of stress arising supporting bone of the natural teeth and the implant was made with 3-dimensional finite element method. The model simulated naturel teeth was made with 2nd premolar and 1st molar in the maxillary molar region (Model T). The model simulated implants placed on same positions with two parallel implants of Straumann Dental Implant cemented abutment (Model I). Each model was designed in different crown-root ratio (0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it non-splinted or splinted. After that, 300 N force was loaded to each model in five ways (Load 1: middle of occlusal table, Load 2: middle of buccal cusp, Load 3: middle of lingual cusp, Load 4: horizontal load to buccal cusp of anterior abutment only, Load 5: horizontal load to middle of buccal cusp of each abutment), and stress distribution was analyzed. Results and conclusion: On all occasions, stress was concentrated at the cervical region of the implant. Under load 1, 2 and 3, stress was not increased even when crown-root ratio increases, but under load 4 and 5, when crown-root ratio increases, stress also increased. There was difference in stress values between natural teeth and implants when crown-root ratio gradually increases; In case of natural teeth, splinting decreased stress under vertical and horizontal loads. In case of implants, splinting decreased stress under vertical loads 1,2 and 3, but increased maximal stress under loads 2 and 3. Under horizontal loads, splinting decreased stress, however the effect of splinting decreased under load 5 than load 4. Furthermore, the stress was increased, when crown-root ratio is 1.25:1. Clinical implications: This limited finite element study suggests that the stress on supporting bone may be increased under non-axial loads and poor crown-root ratio. Under poor crown-root ratio, excessive stress was generated at the cervical region of the implant, and decreased splinting effect for stress distribution, which can be related to clinical failure.

The effect of Ca-P coatings of anodized implant surface on response of osteoblast-like cells in vitro (임플란트 표면의 Ca-P 코팅 방법이 MG63 골모유사세포 반응에 미치는 영향에 대한 in vitro 연구)

  • Kim, Il-Yeon;Jung, Sung-Min;Hwang, Soon-Jung;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.376-384
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the response of osteoblast-like cells to Ca-P coated surface obtained via Ion beam-assisted deposition (IBAD) method and Sol-Gel process on anodized surface by cellular proliferation and differentiation. Material and methods: The surface of a commercially pure titanium (Grade IV) discs with dimension of 10mm diameter and 2 mm thickness was modified by anodic oxidation under a constant voltage of 300 V. The experimental groups were coated with Ca-P by the IBAD method and Sol-Gel process on anodized surface. The surface roughness (Ra) of specimens was measured by optical interferometer and each surface was examined by SEM. To evaluate cell response, MG63 cells were cultured and cell proliferation, ALP activity and the ability of cell differentiation were examined. Also, cell morphology was examined by SEM. The significant of each group was verified by Kruskal-Wallis Test ($\alpha$=.05). Results: The Ra value of Ca-P coated surface by IBAD method was significantly higher than Ca-P coated surface by Sol-gel process (P < .05). The level of cell proliferation and ALP activity was higher in Ca-P coated surface by IBAD method (P<.05). The expression of ALP showed higher level expression in Ca-P coated surface by IBAD method. Cells grown on Ca-P coated surface by IBAD method were uniformly distributed and developed a very close layer. Conclusion: These experiments showed better performances of Ca-P coated surface by IBAD method with respect to Ca-P coated surface by Sol-gel process. Ca-P coated surface by IBAD method appear to give rise more mature osteoblast characteristics and might result in increased bone growth and bone-implant contact.

The effect of various sandblasting conditions on surface changes of dental zirconia and shear bond strength between zirconia core and indirect composite resin

  • Su, Naichuan;Yue, Li;Liao, Yunmao;Liu, Wenjia;Zhang, Hai;Li, Xin;Wang, Hang;Shen, Jiefei
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.214-223
    • /
    • 2015
  • PURPOSE. To measure the surface loss of dental restorative zirconia and the short-term bond strength between an indirect composite resin (ICR) and zirconia ceramic after various sandblasting processes. MATERIALS AND METHODS. Three hundred zirconia bars were randomly divided into 25 groups according to the type of sandblasting performed with pressures of 0.1, 0.2, 0.4 and 0.6 MPa, sandblasting times of 7, 14 and 21 seconds, and alumina powder sizes of 50 and $110{\mu}m$. The control group did not receive sandblasting. The volume loss and height loss on zirconia surface after sandblasting and the shear bond strength (SBS) between the sandblasted zirconia and ICR after 24-h immersion were measured for each group using multivariate analysis of variance (ANOVA) and Least Significance Difference (LSD) test (${\alpha}$=.05). After sandblasting, the failure modes of the ICR/zirconia surfaces were observed using scanning electron microscopy. RESULTS. The volume loss and height loss were increased with higher sandblasting pressure and longer sandblasting treatment, but they decreased with larger powder size. SBS was significantly increased by increasing the sandblasting time from 7 seconds to 14 seconds and from 14 seconds to 21 seconds, as well as increasing the size of alumina powder from $50{\mu}m$ to $110{\mu}m$. SBS was significantly increased from 0.1 MPa to 0.2 MPa according to the size of alumina powder. However, the SBSs were not significantly different with the sandblasting pressure of 0.2, 0.4 and 0.6 MPa. The possibilities of the combination of both adhesive failure and cohesive failure within the ICR were higher with the increases in bonding strength. CONCLUSION. Based on the findings of this study, sandblasting with alumina particles at 0.2 MPa, 21 seconds and the powder size of $110{\mu}m$ is recommended for dental applications to improve the bonding between zirconia core and ICR.

An Analysis of the Job Performance in Operative Restoration by Dental Hygienists (치과위생사의 치과보존분야 직무수행 현황 분석)

  • Cho, Pyeong-Kyu
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.277-291
    • /
    • 2004
  • The purpose of this study is to analyze the dental hygienists' overall performance in operative restoration and the clinical performance in operative restoration according to dental hygienists' career and to provide basic data for establishing the appropriate range of dental hygienists' work. Subjects of this study are 339 dental hygienists working at dental clinic and hospital nationwide, selected by their working place, career, type of clinic, and location of clinical institution. The distribution of people who responded to the survey shows that 81 belong to beginner level(less than 2 years since entering clinic), 115 intermediate level(2 to 3 years since entering clinic), 81 higher level(4 to 5 years since entering clinic) and 62 advanced level(more than 6 years since their entering clinic). In terms of the types of clinical institution, 178 belong to dental clinics and 161 belong to dental hospitals. The survey used in this study are focused on perception about clinical performance in operative dentistry and adequacy of the work. Operative dentistry consists of operative restoration and endodontic therapy. The operative restoration consists of 15 categories such as patient welcoming, examination and diagnosis, planning of treatment, anesthesia, control of moisture, cavity preparation, pulp protection, matrix band application, amalgam filling, resin filling, glass ionomer cement filling, abrasive strip removal, rubber dam removal, bite check and polishing, patient education, and arrangement. The reliability was Cronbach's Alpha .9453. SPSS 10.0 for Windows was used to analyze the responses. One way ANOVA was utilized to verify the differences in the dental hygienists' job performance in operative restoration and their job performance according to career. When significant difference was found. Duncan multi comparison post hoc was done. To sum up the results of this study, patient welcoming look the first place in the operative restoration. It was followed by patient education, examination and diagnosis, introducing treatment plan, resin filling, glass ionomer cement filling, amalgam filling, bite check and polishing, anesthesia, pulp protection, control of moisture, abrasive strip removal, cavity preparation, matrix band application, rubber dam removal, and anesthesia. In terms of the clinical performance by career, there were significant differences in 19 activities such as medical eraluation, oral examination, patient charting, intra oral readio graphs, firm developing fixing mounting, curing light gun, education of attention content after operation. Based on the results of this study, the specific range of operative restoration for dental hygienists should be focused on providing basic data for dentists' diagnosis, alleviation of fear and aching accompanied by injection and anesthesia, data providing for dentists' decision of anesthesia degree, and maximization of control of moisture.

  • PDF

PHOTOTOXIC EFFECTS OF LOW LEVEL LASER IRRADIATION ON HUMAN OSTEOSARCOMA CELLS (골육종세포에 미치는 레이저 조사의 광독성 효과)

  • Son, Jang-Ho;Cho, Young-Chul;Ryu, Sung-Ho;Kim, Gyoo-Cheon;Sung, Iel-Yong;Park, Bong-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.6
    • /
    • pp.509-515
    • /
    • 2004
  • Photodynamic therapy(PDT) has advanced to clinical trials for the treatment of a variety of solid tumors and presents an alternative treatment option for tumors resistant to chemo-and/or radio-therapy. PDT is based on the combination of laser light of appropriate wavelength and energy to activate a systemically or locally applied photosensitizer that concentrates preferentially in malignant tissues. In this study, phototoxicity of laser EIT 21 was analysed in human osteosarcoma cell(HOS) and the second objective of this study was to determine the ability of laser EIT 21 to induce apoptosis. This study demonstrated that laser EIT 21 had a phototoxicity to HOS cells. In order to examinate whether cell death was induced by necrosis or apoptosis, variety of techniques which assess apoptosis were used. TUNEL assay showed only a few the positive reaction on condensed nuclei. It is hard to find condensed or fragmented nuclei on HOS cells irradiated with laser EIT 21 in Hemastat and AO/EB stain. By DNA electrophoresis, cells also did not show DNA degradation characteristic of apoptosis with a ladder pattern of DNA fragments. Apoptosis-related factors were analyzed by western blotting. The expression of p53 was constant and cells irradiated with laser did not show the caspase-3 and PARP degradation, therefore we suggest that p53 and caspase-3 are not involved in laserinduced cell death.

Bond strength of veneer ceramic and zirconia cores with different surface modifications after microwave sintering

  • Saka, Muhammet;Yuzugullu, Bulem
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.485-493
    • /
    • 2013
  • PURPOSE. To evaluate the effects of surface treatments on shear bond strength (SBS) between microwave and conventionally sintered zirconia core/veneers. MATERIALS AND METHODS. 96 disc shaped Noritake Alliance zirconia specimens were fabricated using YenaDent CAM unit and were divided in 2 groups with respect to microwave or conventional methods (n=48/group). Surface roughness (Ra) evaluation was made with a profilometer on randomly selected microwave (n=10) and conventionally sintered (n=10) cores. Specimens were then assessed into 4 subgroups according to surface treatments applied (n=12/group). Groups for microwave (M) and conventionally (C) sintered core specimens were as follows; $M_C$,$C_C$: untreated (control group), $M_1,C_1:Al_2O_3$ sandblasting, $M_2,C_2$:liner, $M_3,C_3:Al_2O_3$ sandblasting followed by liner. Veneer ceramic was fired on zirconia cores and specimens were thermocycled (6000 cycles between $5^{\circ}-55^{\circ}C$). All specimens were subjected to SBS test using a universal testing machine at 0.5 mm/min, failure were evaluated under an optical microscope. Data were statistically analyzed using Shapiro Wilk, Levene, Post-hoc Tukey HSD and Student's t tests, Two-Way-Variance- Analysis and One-Way-Variance-Analysis (${\alpha}$=.05). RESULTS. Conventionally sintered specimens ($1.06{\pm}0.32{\mu}m$) showed rougher surfaces compared to microwave sintered ones ($0.76{\pm}0.32{\mu}m$)(P=.046), however, no correlation was found between SBS and surface roughness (r=-0.109, P=.658). The statistical comparison of the shear bond strengths of $C_3$ and $C_1$ group (P=.015); $C_C$ and $M_C$ group (P=.004) and $C_3$ and $M_3$ group presented statistically higher (P=.005) values. While adhesive failure was not seen in any of the groups, cohesive and combined patterns were seen in all groups. CONCLUSION. Based on the results of this in-vitro study, $Al_2O_{3-}$ sandblasting followed by liner application on conventionally sintered zirconia cores may be preferred to enhance bond strength.