• 제목/요약/키워드: Adhesive Strength Test

검색결과 628건 처리시간 0.027초

상이질 접착제의 적용방법에 따른 전단결합강도와 접착양상에 관한 연구 (INFLUENCE OF APPLICATION METHODS OF A DENTIN ADHESIVE ON SHEAR BOND STRENGTH AND ADHESIVE PATTERN)

  • 박성택;문주훈;조영곤;온영석
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.381-391
    • /
    • 1999
  • A new 5th generation adhesive system(ONE-STEP) has been supplied which operators can apply to conditioned tooth surfaces by one simplified step. The purpose of this study was to determine whether different methods of adhesive application and various air drying duration after applying adhesive affect the shear bond strength of composite resin to dentin, and to evaluate the adhesive pattern of composite resin and dentin under SEM. Seventy-seven extracted human molar teeth were cleaned and mounted in palstic test tubes. The occlusal dentin surfaces were exposed with Diamond Wheel Saw and smoothed with Lapping and Polishing Machine (South Bay Technology Co., U.S.A.). Teeth were randomly divided into 7 groups (n=11), In experimental A group, adhesive was applied to dentin with agitation for 20 sec. In experimental N-A group, adhesive were continuously applied to dentin for 20 sec. Also control and experimental 1, 2, 3, 4 groups were dried for 10, 0, 5, 20, 30 seconds after applying adhesive, respectively, Adhesives were light cured for 10 sec. A gelatin capsule 5mm in diameter was filled with Aelitefil$^{TM}$ composite resin, placed on the treated dentin surface and light cured for 40 see, from three sides, All specimens were stored in distilled water at room temperature for 24 hours. The shear bond strengths were measured using a universal testing machine(AGS-1000 4D, Japan) at a crosshead speed of 5mm/min. An one-way ANOVA and LSD test were used for statistical analysis of the data. For SEM evaluation, seven specimens were made and sectioned. Representive postfracture and seven specimens were mounted on brass stubs, sputter-coated with gold and observed under SEM. The results were as follows : 1. The shear bond strength of experimental A group which adhesive were applied to dentin with agitation was higher than that of experimental N-A group (continuous application), and there was significant difference between two groups (p<0.01). 2. The interface between composite and dentin according to different application methods showed close adaptation in experimental A group and showed tinny gap in experimental N-A group. 3. The shear bond strength accoding to various air drying duration was the lowest value(7.57${\pm}$2.60 MPa) in experimental 1 group, so there was significant difference between experimental 1 group and other four groups (p<0.05). But there was no significant difference of shear bond strength between four groups (p>0.05). 4. The interface between composite and dentin according to various air drying duration showed close adaptation in control group and tinny gap in experimental 3 and 4 groups. But experimental 1 and 2 groups showed $30{\mu}$ and 6 - $10{\mu}m$ thick gaps, respectively.

  • PDF

특수시멘트 혼입 에폭시 수지계 콘크리트용 바탕조정재의 기초물성에 관한연구 (A Study on Fundamental Performance of Epoxy Resin Mortar Mixed Special Cement for Concrete Surface Control)

  • 최성민;김용현;황원주;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표회 논문집(I)
    • /
    • pp.145-150
    • /
    • 1998
  • This study deals with the effect on performance of epoxy resign mortar mixed special cement for surface control and maintenance of aging concrete construction. The test of main property of epoxy resign in this study are the evaluation on the adhesive strength between substrate and epoxy resign mortar under the environment of wet or concrete substrate surface. We gained the test results of good adhesive strength over 15 kgf/$\textrm{cm}^2$ under the wet and dry condition of concrete surface.

  • PDF

중간레진의 친수성이 상아질 접착에 미치는 영향 (EFFECT OF INTERMEDIATE RESIN HYDROPHILICITY ON BOND STRENGTH OF SINGLE STEP ADHESIVE)

  • 김용성;박상혁;최기운;최경규
    • Restorative Dentistry and Endodontics
    • /
    • 제32권5호
    • /
    • pp.445-458
    • /
    • 2007
  • 단일과정 접착제를 이용함에 있어 복합레진과의 부적합성을 개선하고자 중간레진이 결합에 영향을 미칠 것으로 사료된다. Experimental single step system (Bisco Ltd., Schaumburg, IL)을 대조군으로 하고 6종의 중간레진을 접착제의 중합여부, 복합레진의 광중합-자가중합 여부로 분류하였다. 상아질에 대한 광중합 또는 자가중합형 복합레진의 결합강도를 측정하고 접착계면에 대한 투과전자현미경 관찰하여 다음과 같은 결론을 얻었다. 1. 중간레진의 적용은 광중합형 복합레진의 결합강도를 증가시키지 않았다. 2. 자가중합형 복합레진의 결합강도는 중간레진을 적용할 경우 증가하였다. 3. 중간레진의 적용 전 접착제의 중합여부는 결합강도의 변화에 영향을 미치지 않았다. 4. 중간레진이 친수성일 때 소수성 중간레진을 적용할 때 보다 높은 결합강도를 나타냈으나 통계적 유의차는 없었다. 광중합형 복합레진의 수복 시 단일과정 접착제를 사용하는 것은 초기 결합강도에 영향을 미치지 않으며, 자가중합형 복합레진을 단일과정 접착제와 사용할 때는 접착층의 투과도를 감소시키는 소수성의 중간레진을 적용하여 부적합성을 해소할 수 있을 것이다.

세라믹 박판의 접착 강도 측정 (Measurement of Adhesion Strength for Ceramic Sheet)

  • 허용학;김동일;김동진;이경호;김동진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1798-1802
    • /
    • 2007
  • Adhesion strength of single layer ceramic capacitor sheet was measured using a peel testing system developed in this study. The peel test specimens with various dimensions were prepared from the ceramic sheet cast on the PET film. In peel test, the sheet specimen was adhered on the glass jig floating on the liquid media, which was designed to minimize the friction, and the specimen was then pulled up by micro-actuator. During the separation of the sheet from the PET film, peel force was measured. To normalize the testing condition, 3 different widths of the specimen were selected: 5, 10 and 20 mm. was used Furthermore, testing speed effect was investigated in this study. From the resullts using various testing conditions, the standard method for the peel strength testing may be suggested. Based on the testing condition, effect of peel angle on the strength was experimentally examined. It was found that the adhesive strength for the ceramic sheet is nearly identical, irrespective of the specimen width ranged from 5 to 20 mm, while the adhesive strength was increased with increasing testing speed. Furthermore, the strength was shown to be dependent on the peel angle.

  • PDF

수치 모델을 사용한 콘크리트-FRP 부착면의 거동 특성 (Charateristics of Adhesive Joint between Concrete and FRP Using Numerical Method)

  • 조정래;조근희;박영환;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.219-222
    • /
    • 2003
  • Substantial experimental and theoretical work exists on the bond characteristics of FRP-concrete adhesive joints. Experimental studies show that the bond strength cannot always increase with an increase in the bond length, and that the ultimate strength is strongly influenced by the concrete strength. To solve this feature, analytic solutions based on fracture mechanics are widely used, and the local shear stress-slip curve with a softening branch is known as more rational model. The analytic solution, however, cannot describe various shapes of model curve. In this study, numerical method using interface element is introduced to express various shapes of model curve. Characteristics of adhesive joint is investigated for the shapes of the model curve and their parameters. And the numerical solutions are compared with the test results of CFRP sheet adhesive joints.

  • PDF

요소(尿素)·멜라민·페놀공축합수지(共縮合樹脂)가 합판(合板)의 재질(材質)에 미치는 영향(影響) (Effects of Urea-Phenol-Melamine Copolymer Adhesive on the Plywood Qualities)

  • 이화형;홍승도
    • Journal of the Korean Wood Science and Technology
    • /
    • 제12권1호
    • /
    • pp.38-43
    • /
    • 1984
  • Water soluble urea-melamine-phenol copolymer adhesive manufactured with 80 percent of urea resin contents was manufactured by different molar ratio for a high temperature curing type, and their properties and strengthes were examined through manufactures of plywood with Kapur (Dryobalanops spp.) veneers. The results are summarized as follows: 1. Specific gravities of air dried plywood manufactured from each adhesive ranged from 0.78 to 0.84 and their moisture contents met the KS requirement. 2. In dry and wet shear strength, $U_{80}M_{10}P_{10}$ copolymer resin showed the highest value and urea resin was the lowest, indicating that melamine and phenol were effective for increasing glue shear strength of urea resin. 3. In case of glue shear strength after boiling test, phenolic resin was the nest and melamine was not so effective as phenol on reinforcement of boiling water resistance of urea resin.

  • PDF

아크릴계 점착제의 제조 및 점착특성에 관한 연구 (Preparation and Characteristics of Acrylic Pressure-Sensitive Adhesives)

  • 김남석;박근호
    • 한국응용과학기술학회지
    • /
    • 제18권4호
    • /
    • pp.316-324
    • /
    • 2001
  • To prepare an acrylic type pressure-sensitive adhesive, quarternary polymers were synthesized from butyl acrylate (BA), 2-ethyl hexyl acrylate (2-EHA), methyl methacrylate (MMA), and 2-hydroxy ethyl methacrylate (2-HEMA). The quarternary polymers were identified by FT-IR and Molecular weight was measured by Gel Pearmeation Chromatography. Also, viscosity, solid content and peel strength were examined. The peel strength was 160 $g_{f}/25$ mm when the volume ratio of feed monomer to solvent was 1.3:1, and the ratio was relevant to commercial usage. The pot life of adhesive was 30 sec at the 50 m/min of heat treatment rate at, and it indicated that the minimum drying time was 30 sec. In weathering resistance test, peel strength of $160{\sim}180$ $g_{f}/25$ mm after 1000 h, with no residual remains on the adhesive surface.

소독제가 개인용 트레이와 실리콘 인상재의 접착력에 미치는 영향에 대한 연구 (EFFECT OF DISINFECTION OF CUSTOM TRAY MATERIALS ON ADHESIVE PROPERTIES OF SEVERAL IMPRESSION MATERIAL SYSTEMS)

  • 김정한;정창모;전영찬;황의성
    • 대한치과보철학회지
    • /
    • 제34권2호
    • /
    • pp.290-298
    • /
    • 1996
  • The effects of impression tray disinfection procedures on the bond strength of impression-material adhesive to two of types resin trays were evaluated with a tensile test. Autopolyme-rizing acrylic resin was formed into 1x1x1 cm cubes. A hook was attached to each cube with autopolymerizing acrylic resin. Perforated trays were fabricated with stops to maintain an even 3 cm of impression material over the resin block. Hook on the opposite side of the perforated tray permitted attachment of the metal plate to a mechanical testing machine. Before adhesive was applied, one third of the resin specimens were immersed in a 5% sodium hypochlorite solution : one third in a 2% glutaradehyde solution, and one third were kept in the "as fabricated" condition. Three products(Perfect ups, Exafine, and Exp-ress) of polyvynil siloxane impression material-adhesive system were evaluated. The resin-impression material-metal plate couples were attached to a mechanical testing machine and tensile forces were applied at a separation rate of 10 centimeters per second. The results were as follows; 1. Both disinfectant and adhesive had effects on bond strength values, but adhesive had more effect than disinfectant(p<0.01). However, there was no interaction between dinin-fectant and adhesive(p>0.01). 2. Mean bond strength values for the Perfect materials were about 85% less than that of the Exafine or the Express materials. However, there was no stastically significant difference between the mean bond strength values of the Exafine materials and the Express materials(p>0.05). 3. The use of disinfectants produced significant reduction in bond strength values(p<0.05). But there was no stastically significant difference between the mean bond strength values of the groups treated with disinfectants(p>0.05).

  • PDF

Effect of chlorhexidine application on the bond strength of resin core to axial dentin in endodontic cavity

  • Kim, Yun-Hee;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.207-214
    • /
    • 2012
  • Objectives: This study evaluated the influence of chlorhexidine (CHX) on the microtensile bonds strength (${\mu}TBS$) of resin core with two adhesive systems to dentin in endodontic cavities. Materials and Methods: Flat dentinal surfaces in 40 molar endodontic cavities were treated with self-etch adhesive system, Contax (DMG) and total-etch adhesive system, Adper Single Bond 2 (3M ESPE) after the following surface treatments: (1) Priming only (Contax), (2) CHX for 15 sec + rinsing + priming (Contax), (3) Etching with priming (Adper Single Bond 2), (4) Etching + CHX for 15 sec + rinsing + priming (Adper Single Bond 2). Resin composite build-ups were made with LuxaCore (DMG) using a bulk method and polymerized for 40 sec. For each condition, half of specimens were submitted to ${\mu}TBS$ after 24 hr storage and half of them were submitted to thermocycling of 10,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ before testing. The data were analyzed using ANOVA and independent t-test at a significance level of 95%. Results: CHX pre-treatment did not affect the bond strength of specimens tested at the immediate testing period, regardless of dentin surface treatments. However, after 10,000 thermocycling, all groups showed reduced bond strength. The amount of reduction was greater in groups without CHX treatments than groups with CHX treatment. These characteristics were the same in both self-etch adhesive system and total-etch adhesive system. Conclusions: 2% CHX application for 15 sec proved to alleviate the decrease of bond strength of dentin bonding systems. No significant difference was shown in ${\mu}TBS$ between total-etching system and self-etching system.

혼성층의 두께가 three-step과 self-etching 상아질 접착제의 미세인장결합강도에 미치는 효과 (THE EFFECT OF HYBRID LAYER THICKNESS ON MICROTENSILE BOND STRENGTH OF THREE-STEP AND SELF-ETCHING DENTIN ADHESIVE SYSTEMS)

  • 이혜정;박정길;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.491-497
    • /
    • 2003
  • The purpose of this study was to evaluate the correlation between hybrid layer thickness and bond strength using confocal laser scanning microscope and microtensile bond strength test of two adhesive systems. The dentin surface of human molars. sectioned to remove the enamel from the occlusal surface. Either Scotchbond Multi-Purpose(3M Dental Product, St. Paul, MN, U.S.A) or Clearfil SE Bond (Kuraray, Osaka, Japan) was bonded to the surface. and covered with resin-composite. The resin-bonded teeth were serially sliced perpendicular to the adhesive interface to measure the hybrid layer thickness by confocal laser scanning microscope. The specimen were trimmed to give a bonded cross-sectional surface area of $1\textrm{mm}^2$, then the micro-tensile bone test was performed at a cross head speed of 1.0 mm/min. All fractured surfaces were also observed by stereomicroscope. There was no significant differences in bond strengths the materials(p>0.05). However. the hybrid layers of three-step dentin adhesive system, SM, had significantly thicker than self-etching adhesive system. CS(p<0.05). Pearson's correlation coefficient showed no correlation between hybrid layer thickness and bond strengths(p>0.05). Bond strengths of dentin adhesive systems were not dependent on the thickness of hybrid layer.