• Title/Summary/Keyword: Adhesive Strength Test

Search Result 628, Processing Time 0.025 seconds

Comparative Study on Test Method of Compressive and Flexural Characteristics of Structural Adhesives for FRP Composites used in Strengthening RC Members (구조보강용 FRP 함침.접착수지의 압축.휨 특성치 시험방법 비교 연구)

  • You, Young-Chan;Choi, Ki-Sun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.349-352
    • /
    • 2006
  • Pull-off test is generally used as a method of evaluating bond strength of FRP with concrete at the job site. However, pull-off test damages FRP composites and the maximum pull-off strength is limited up to tensile strength of concrete. Accordingly, it is required to set-up a test method that can simply evaluate bond performance of structural adhesive. This study suggested compression and bending test of epoxy resin as test methods that can indirectly evaluate performance of adhesive, as well as standardized test specification for different types of specifications from various countries. In this study, the section dimension of compression and bending test specimens is unified, and standard test specimen size is achieved by test results.

  • PDF

The Effect of Nano Functionalized Block Copolymer Addition on the Joint Strength of Structural Epoxy Adhesive for Car Body Assembly (차체 구조용 에폭시 접착제의 접합강도에 미치는 나노 기능성 블록공중합체 첨가의 영향)

  • Lee, Hye-rim;Lee, So-jeong;Lim, Chang-young;Seo, Jong-dock;Kim, Mok-soon;Kim, Jun-ki
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.44-49
    • /
    • 2015
  • The structural epoxy adhesive used in car body assembly needs the highest level of joint mechanical strength under lap shear, T-peel and impact peel conditions. In this study, the effect of nano functionalized block copolymer addition on the impact peel strength of epoxy adhesive was investigated. DSC analysis showed that the addition of nano functionalized block copolymer did not affect the curing reaction of epoxy adhesive. From single lap shear test, it was found out that the addition of nano functionalized block copolymer slightly decreased the cohesive strength of cured adhesive layer. The addition of nano functionalized block copolymer showed beneficial effect on T-peel strength by changing the adhesive failure mode to the mixed mode. However, the addition of nano functionalized block copolymer just decreased the room temperature impact peel strength. It was considered that the addition of nano functionalized block copolymer could have effect on disturbing the crack propagation only for the case of slow strain rate.

Fatigue Strength Evaluation of T-Peel Adhesive Joing for Light Weight Material (경량 재료의 T형 접합이음의 피로강도 평가)

  • Lee, K.Y.;Kong, B.S.;Choi, H.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.166-173
    • /
    • 1998
  • The evaluation of joint fatigue strength of light weight materials for an electrical vehicle body has been performed through T-peel joint tests with the design parameters such as joint style, adherend type, adherend thickness, adhesive thickness, and various adhesives. Fatigue strength was evaluated through 5-Hz, tension-tension, load controlled test with the zero stress ratio. It was observed that the fatigue strength of the joint increases with the increase of the adherend thickness. With the increase of the adhesive thickness, however, the fatigue strength of the joint increases insignificantly. An aluminum-FRP adherend combination shows much higher fatigue strength than an aluminum-aluminum adherend combination. The results of fatigue tests were found to be consistent with those of static tests.

  • PDF

IN VITRO SHEAR BOND STRENGTH OF CERAMIC BRACKETS (도재 브라켓의 전단접착강도에 관한 실험적 연구)

  • Lee, Suhng-Jin;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.22 no.2 s.37
    • /
    • pp.449-474
    • /
    • 1992
  • The purpose of this study was to evaluate the in vitro shear bond strengths to enamel and the failure sites of three ceramic brackets and one metal bracket in combination with light cured orthodontic adhesive. The brackets were divided into four groups. Each ceramic bracket group had different bonding mechanisms with adhesive. Group A; metal bracket with foil-mesh base (control group) Group B; ceramic bracket with micromechanical retention Group C; ceramic bracket with chemical bonding Group D; ceramic bracket with mechanical retention and chemical bonding. Forty extracted human lower first premolars were prepared for bonding and 10 brackets for each group were bonded to prepared enamel surfaces with $Transbond^{\circledR}$ light cured ortho dontic adhesive. Twenty four hours after bonding, the Instron universal testing machine was used to test the shear bond strength of brackets to enamel. After debonding, brackets and enamel surfaces were examined under stereoscopic microscope to determine the failure sites, Statistical analysis of the data was carried out with ANOVA test and $Scheff\acute{e}$ test using SPSS PC+. The results were as follows. 1 . There were statistically significant differences in mean shear bond strengths of three ceramic bracket groups (p < 0.05). Shear bond strengths of group C and D were significantly higher than that of group B and shear bond strength of group C was significantly higher than that of group D. 2. Group C and D both had significantly higher shear bond strengths than metal bracket (group A), but there were no significant differences in shear bond strengths between group A and B (p < 0.05). 3. The failure sites of four bracket groups were also different. Group C and D failed primarily at enamel-adhesive interface, but group A and B failed primarily at bracket base-adhesive interface. 4. Among all ceramic bracket groups, group B was very similar to metal bracket in the aspect of shear bond strength and failure site.

  • PDF

An Experimental Study on the Characteristics of Evaluation with Feature of Self Levelling Primer (셀프레벨링 모르타르용 Primer 성상에 따른 특성평가에 관한 실험적 연구)

  • Kang, Dong-Gyun;Kim, Gyung-Yuk;Kim, Jung-Wan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.505-508
    • /
    • 2006
  • Self-leveling mortar is walkable bottom mortar which can maintain the horizontality of self fluid and have the the quick-setting quality, the low-human-effort practicable material of high-quality bottom in construction. In accordance with more adhesive strength with bottom side and absorption control, Primer is used for purpose to prevent pin-hole occurrence by self leveling mortar application prior to construction. This study is composed measurement of absorption, adhesive strength. Used material is NP-40 as nonionic emulsifying agent, uses SA-210L as negative ion emulsifying agent, uses APS, SBS as ridical initiator. A result of test, in accordance with image of Primer, as low temperature and application frequency, indicates low absorption rate and adhesive strength, as solid powder and dryness time is increse, absorption rate and adhesive strength lowly shows figure.

  • PDF

Study on Thermally Properties of $250^{\circ}F$ Epoxy-Adhesive Film for Aluminum Sandwich Construction with Weight Reduction (차체경량화 알루미늄 샌드위치구조용 $250^{\circ}F$ 에폭시 접착필름 열적 특성 평가)

  • Oh Kyung-Won;Lee Sang-Jin;Jeong Jong-Cheol;Cho Sea-Hyun;Mok Jai-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1089-1096
    • /
    • 2005
  • This study was experimental test of edgewise compression properties for aluminum(type-50XX) sandwich panel with thermal environment and surface treatment using adhesive film. There was decreasing $10\%-peel$ strength after thermal environment. Through compressive. buckling mode know to seen of properties of adhesive, sheet and core strength. First case of Chromate to aluminum sheet, know low shear strength of adhesive through buckling mode but case of Beomite to aluminum sheet, know than thin sheet and core low strength through buckling mode.

  • PDF

Effect of Sealing on the Corrosion Resistance of Plasma-Sprayed Alumina Coatings (실링이 플라즈마 스프레이 코팅된 알루미나 코팅재의 내부식성에 미치는 영향)

  • Kwon, Eui Pyo;Kim, Se Woong;Lee, Jong Kweon
    • Korean Journal of Materials Research
    • /
    • v.32 no.10
    • /
    • pp.442-447
    • /
    • 2022
  • Sealing treatment is a post-surface treatment of the plasma spray coating process to improve the corrosion resistance of the coating material. In this study, the effect of the sealing on the corrosion resistance and adhesive strength of the plasma spray-coated alumina coatings was analyzed. For sealing, an epoxy resin was applied to the surface of the coated specimen using a brush. The coated specimen was subjected to a salt spray test for up to 48 hours and microstructural analysis revealed that corrosion in the coating layer/base material interface was suppressed due to the resin sealing. Measurement of the adhesive strength of the specimens subjected to the salt spray test indicated that the adhesive strength of the sealed specimens remained higher than that of the unsealed specimens. In conclusion, the resin sealing treatment for the plasma spray-coated alumina coatings is an effective method for suppressing corrosion in the coating layer/base material interface and maintaining high adhesive strength.

Effect of Neonicochid Type Wood Preservative on Adhesive Properties of Resorcinol Resin for Lminated Wood (네오니코치드계 목재보존제가 집성재 제조용 레조르시놀 수지의 접착력에 미치는 영향)

  • Lee, Dong Heub;Lee, Jong Shin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.34-40
    • /
    • 2014
  • The effect of neonicochid type wood preservatives on adhesive properties of resorcinol-formaldehyde resin for laminated wood manufacture was examined. By the previous studies, it was verified that the neonicochid type preservative has a high termite-proofing and anti-mold effectiveness. Commercial ACQ (ammoniacal copper quaternary compounds) and CUAZ (copper azol compounds) were used as comparison preservatives of effects on adhesive properties. The wood specimens used japanese red pine (Pinus densifrora) after application with preservatives and then bonded with resorcinol-formaldehyde resin. Adhesive properties were evaluated by shearing strength of adhesive bond and wood failure to dry condition or after accelerated aging test. Of all laminated woods, the wood specimens spread with ACQ or CUAZ showed the lowest shearing strength of adhesive bond. We estimated that the decrease of shearing strength was caused by copper in the ACQ or CUAZ preservatives. On the application of the neonicochid type preservatives, the wood specimens showed the highest shearing strength even after accelerated aging test. From these results, it is concluded that the copper-free neonicochid type preservative not affected the curing of resorcinol-formaldehyde resin.

Bond strength of self-adhesive resin cements to composite submitted to different surface pretreatments

  • dos Santos, Victor Hugo;Griza, Sandro;de Moraes, Rafael Ratto;Faria-e-Silva, Andre Luis
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.12-16
    • /
    • 2014
  • Objectives: Extensively destroyed teeth are commonly restored with composite resin before cavity preparation for indirect restorations. The longevity of the restoration can be related to the proper bonding of the resin cement to the composite. This study aimed to evaluate the microshear bond strength of two self-adhesive resin cements to composite resin. Material and Methods: Composite discs were subject to one of six different surface pretreatments: none (control), 35% phosphoric acid etching for 30 seconds (PA), application of silane (silane), PA + silane, PA + adhesive, or PA + silane + adhesive (n = 6). A silicone mold containing a cylindrical orifice ($1mm^2$ diameter) was placed over the composite resin. RelyX Unicem (3M ESPE) or BisCem (Bisco Inc.) self-adhesive resin cement was inserted into the orifices and light-cured. Self-adhesive cement cylinders were submitted to shear loading. Data were analyzed by two-way ANOVA and Tukey's test (p < 0.05). Results: Independent of the cement used, the PA + Silane + Adhesive group showed higher microshear bond strength than those of the PA and PA + Silane groups. There was no difference among the other treatments. Unicem presented higher bond strength than BisCem for all experimental conditions. Conclusions: Pretreatments of the composite resin surface might have an effect on the bond strength of self-adhesive resin cements to this substrate.

Adhesive characteristics of water-paint and silane adhesive mixture (수성페인트-실란접착제 혼합물의 접착특성)

  • HAN, Hyun Kak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5721-5727
    • /
    • 2015
  • Paint must be resistant to the wear and tear of the atmosphere and should maintain its color and finish for a long time. The solvents of paints were organic solvent and water, common artificial source of VOCs(Volatile organic Solvent) include organic solvent. Using of organic solvent paint was decreased in the interior parts of automotive, exterior parts were still used organic solvent paint. Adhesive strength of water-paint was poor to compare with organic solvent paint and peeled off from the base materials, it was big quality problem. In this study, adhesive characteristics of water-paint and silane mixture was investigated. To improve adhesive strength of water-paint, it was necessary to mixing of adhesive material. Adhesive strength was measured using UTM(Universal Test Instrument) by ASTM D1002 and Peeling off condition was by ASTM D3359. Optimal mixing condition of water-paint and silane adhesive were $25^{\circ}C$, 500rpm, 20min., concentration of silane adhesive was 5 wt%.