• 제목/요약/키워드: Accuracy Standards

검색결과 493건 처리시간 0.03초

QFD 기법을 이용한 패키지 소프트웨어의 품질 요구사항 획득 (Acquiring Quality Requirements of Package Software using Quality Function Deployment Technique)

  • 유영관;이종무
    • 품질경영학회지
    • /
    • 제29권2호
    • /
    • pp.120-130
    • /
    • 2001
  • In this paper, the QFD(quality function deployment) technique is used to acquire the quality requirements of package software which is sold in commercial software shop. To select the principal quality characteristics of package software, an user survey was conducted for a quality model developed based on the international standards and the previous research. The software user is divided into three groups: the general user, the expert, and the developer. Based on the survey results, the top 10 quality characteristics are selected including accuracy, suitability, installability, de-installability, and maturaty. Then, the QFD technique is applied to choose the software quality attributes which have strong correlation with the selected quality characteristics, some of which are traceability, accuracy, modularity, completeness, and self-descriptiveness. The developed procedure can be used in evaluating the quality of package software with lower costs and efforts.

  • PDF

피팅용 프레스 포밍 파이프 성형 모델 선정 및 검증 (Selection and Verification of Press Forming Pipe Model using Pipefitting)

  • 김태걸;김태호;박준홍;박영철
    • 한국기계가공학회지
    • /
    • 제14권3호
    • /
    • pp.43-49
    • /
    • 2015
  • This paper describes the design of a forged fitting form to acquire a method of product design measurement by target measurement standards. The pipefitting connects each pipe and combines seals and nipples with the pipes normally. Therefore, the section combined with the fitting pipe was measured by a 3D scanner, and the acquired measurement and the design measurement were obtained after modification of the forged fitting pipe by that standard. Moreover, the accuracy of the model was verified through leakage testing of the oil and verification of the design measurement for accuracy decisions on the design measurement after modification of the product.

디지탈 화상처리를 이용한 게이지 블록의 측정 자동화 (Automatic measurement of gage block using digital image processing)

  • Ko, Y.U.;Suh, H.S.;Eom, T.B.
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.56-65
    • /
    • 1994
  • We have carried out a research on automatic measurement of gage blocks below 250mm and then improved the accuracy of the system, and reduced the measurement time using image processing technique and computer interface. The accuracy of the system is (230+10330 $L^{2}$)$^{2}$ nm (L:m) with confidence level of 95%. We participated APMP gage block intercomparision-1993/1994. The 1st round intercomparision showed that the measured values of all 5 gage blocks were within 21 nm from average.

  • PDF

차량 MMS를 이용한 국가기본도 수시 수정 (Frequent Unscheduled Revision of National Base Map with Vehicle-Based Mobile Mapping System)

  • 김창우;윤홍식;황진상;정태준;신동준
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.311-313
    • /
    • 2010
  • This study is on the adapting vehicle-based mobile mapping system to the frequent unscheduled revision of 1:5000 scale national base map. We analyzed map layers which could be built by vehicle-based mobile mapping systems and studied surveying methods for each layers. Also, the methods of maintain surveying accuracy to satisfy accuracy standards of national base map were suggested. The maps of Yeouido, Hyangnam, and Suwon area were revised by vehicle-based mobile mapping system on a trial bases and possibility of utilizing vehicle-based mobile mapping system for map revision was analyzed. As a results it was revealed that vehicle-based mobile mapping systems were adequate for a irregular revision of national base map.

  • PDF

우리나라 1등수준망의 조정계산 (Adjustment Computation of the Korean Primary Levelling Network)

  • 이석찬;조규전;고영호;이영진
    • 한국측량학회지
    • /
    • 제5권2호
    • /
    • pp.12-23
    • /
    • 1987
  • 본 연구에서는 국립지리원에서 1974년-1986년에 수행한 우리나라 제 1차 1등수준측량 데이터의 철저한 분석이 이루어졌다. 각 노선별 정확도의 분석과 조정결과의 검토를 통하여 각국의 경우와 비교ㆍ평가되었다. 연구결과로는 수준망에 내재된 정오차가 전반적으로 크게 나타나고 있으나 국제측지학협회(IAG)의 정밀수준측량 정확도를 만족하고 있으므로 지도제작이나 건설공사용으로 타당함을 보여주고 있다.

  • PDF

3-D Surface Profile Measurement Using An Acousto-optic Tunable Filter Based Spectral Phase Shifting Technique

  • Kim, Dae-Suk;Cho, Yong-Jai
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.281-287
    • /
    • 2008
  • An acousto-optic tunable filter based 3-D micro surface profile measurement using an equally spaced 5 spectral phase shifting is described. The 5-bucket spectral phase shifting method is compared with a Fourier-transform method in the spectral domain. It can provide a fast measurement capability while maintaining high accuracy since it needs only 5 pieces of spectrally phase shifted imaging data and a simple calculation in comparison with the Fourier transform method that requires full wavelength scanning data and relatively complicated computation. The 3-D profile data of micro objects can be obtained in a few seconds with an accuracy of ${\sim}10nm$. The 3-D profile method also has an inherent benefit in terms of being speckle-free in measuring diffuse micro objects by employing an incoherent light source. Those simplicity and practical applicability is expected to have diverse applications in 3-D micro profilometry such as semiconductors and micro-biology.

순음 청력검사를 위한 원격진단 모니터링 시스템 (Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry)

  • 이강호;권영은;권오원
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

Uncertainty Quantification of Thermophysical Property Measurement in Space and on Earth: A Study of Liquid Platinum Using Electrostatic Levitation

  • Jannatun Nawer;Takehiko Ishikawa;Hirohisa Oda;Chihiro Koyama;Douglas M. Matson
    • Journal of Astronomy and Space Sciences
    • /
    • 제40권3호
    • /
    • pp.93-100
    • /
    • 2023
  • A study of uncertainty analysis was conducted on four key thermophysical properties of molten Platinum using a noncontacting levitation technique. More specifically, this work demonstrates a detailed reporting of the uncertainties associated with the density, volumetric thermal expansion coefficient, surface tension and viscosity measurements at higher temperatures for a widely used refractory metal, Platinum using electrostatic levitation (ESL). The microgravity experiments were conducted using JAXA's Electrostatic Levitation Furnace (ELF) facility on the International Space Station and the terrestrial experiments were conducted using NASA's Marshal Space Flight Center's ESL facility. The performance of these two facilities were then quantified based on the measurement precision and accuracy using the metrological International Standards Organization's Guide to the Expression of Uncertainty Measurement (GUM) principles.

전압변성기 비교기의 위상각 오차 평가 (Evaluation for Phase displacement of Voltage Transformer Comparator)

  • 한상길;김윤형;정재갑;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2030-2031
    • /
    • 2008
  • We have developed the calibration technique of the VT comparator using nonreactive standard resistors and a standard capacitor, which evaluates both accuracy and linearity of the VT comparator by comparing experimental values with theoretical values. The specification for phase displacement of VT comparator have been revaluated.

  • PDF

Channel Estimation Scheme for WLAN Systems with Backward Compatibility

  • Kim, Jee-Hoon;Yu, Hee-Jung;Lee, Sok-Kyu
    • ETRI Journal
    • /
    • 제34권3호
    • /
    • pp.450-453
    • /
    • 2012
  • IEEE 802.11n standards introduced a mixed-mode format frame structure to achieve higher throughput with multiple antennas while providing backward compatibility with legacy systems. Although multi-input multi-output channel estimation was possible only with high-throughput long training fields (HT-LTFs), the proposed scheme utilizes a legacy LTF as well as HT-LTFs in a decision feedback manner to improve the accuracy of the estimates. It was verified through theoretical analysis and simulations that the proposed scheme effectively enhances the mean square error performance.