PURPOSE. The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS. Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with ${\alpha}$-level of 0.05. RESULTS. 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION. Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.
Although there are many different ways that restorations can be made, it can be said that the biocompatibility of abutment and crown is very important in this experiment. When placed in the actual oral cavity, the differences were obvious. Compared to In-ceram Aluminium, the structure that is obtained after firing reveals a particularly homogeneous distribution of the crystal and glass phase. The In-ceram aluminium system had many problems, such as having weak tensile strength, and having low bonding strength due to the shrinking that occurs after firing. Because of the opaque finish of the metal frame, the two may look similar from the outside, but it is evident that there are differences between using a metal frame and In-ceram. VITA VM9 has been designed as a special ceramic featuring a fine structure or stabilized Zro2 substructures, and so the VITA VM9 excels in its light refraction and reflection behavior, which is similar to natural teeth. It also has outstanding chemical balance, which presents advantages such as considerably reduced accumulation of plaque on the ceramic surface.? This ultimately results in easier care and cleaning for the patient.
In order to investigate the internal adaptability and cytotoxicity for porcelain fused to metal Ni-Cr alloy, two commercial alloys (Generic Gold-R alloy, Aalba Dent- Valloy)were employed and compared with new developed beryllium free Ni-Cr alloy (KIST-K alloy). After cementation of each crown to abutment die before and after ceramic bonding respectively, dies were mounted to epoxy resin and the internal space was measured between crown and die of each point on sagittal section. The results were as follows: 1) The results show that the space between the crown and the die was largest at the incisal edge, followed by the shoulder or the bevel and chamfer. The least was to be in the axial surface. 2) There were no significant difference in the adaptability of the compared alloys. 3) On day 2 of the experiment the cell multiplication was slightly inhibited by R and K alloys. However, observations taken at day 4 and 7 showed normal cell multiplication process compared to control group. 4) Alloy V exhibited the most severe cell toxicity among the alloys tested on day 2. By day 4 and 7 it showed a decrease level in toxicity, however it did not exhibit normal cell growth as compared to control group.
This study aims to investigate the clinical outcome following treatment of peri-implantitis lesions. Five subjects with 7 implants were treated with surgical approach. Four subjects with 6 implants were initially treated with non-surgical approach or hygiene control. However, inflammation was not resolved and more bone loss was found. Therefore, surgical treatment was performed. After surgical exposure of the defect, granulation tissue was removed and implant surface was treated using tetracycline and chlorhexidine. Then, the flaps were sutured. The wound healing was performed in a non-submerged mode. The present finding demonstrates stable results without progression of bone loss. In one subject, deep V shaped bone defect was filled with bone substitute (ICB, CanCellous Bone, Rockey Mountain Tissue Bank, USA), and resorbable membrane (Lyoplant$^{(R)}$, B.Braun Aesculap AG, Germany) was placed over the grafted defect and healing abutment was connected. However, the inflammation was not resolved and more bone loss was found. At one month after regenerative surgery, the implant was removed.
Karakas-Stupar, Irina;Zitzmann, Nicola Ursula;Joda, Tim
The Journal of Advanced Prosthodontics
/
제14권2호
/
pp.63-69
/
2022
PURPOSE. The aim of this in vitro study was to investigate the accuracy (trueness and precision) of five intraoral scanners (IOS) using a novel reference model for standardized performance evaluation. MATERIALS AND METHODS. Five IOSs (Medit i500, Omnicam, Primescan, Trios 3, Trios 4) were used to digitize the reference model, which represented a simplified full-arch situation with four abutment teeth. Each IOS was used five times by an experienced operator, resulting in 25 STL (Standard Tessellation Language) files. STL data were imported into 3D software (Final Surface®) and examined for inter- and intra-group analyses. Deviations in the parameter matching error were calculated. ANOVA F-test and Kruskal-Wallis test were applied for inter-group comparisons (α = .05); and the coefficient of variation (CV) was calculated for intra-group comparisons (in % ± SD). RESULTS. Primescan (matching error value: 0.015), Trios 3 (0.016), and Trios 4 (0.018) revealed comparable results with significantly higher accuracy compared to Medit i500 (0.035) and Omnicam (0.028) (P < .001). For intra-group comparison, Trios 4 demonstrated the most homogenous results (CV 15.8%). CONCLUSION. The novel reference model investigated in this study can be used to assess the performance of dental scanning technologies in the daily routine setting and in research settings.
지르코니아 폴리크리스탈은 (Y-TZP) 다른 치과용 세라믹에 비해 기계적 강도와 파절저항성이 우수하다. 지르코니아 기반 세라믹은 캐드캠 시스템을 바탕으로 고정식 수복물 제작에 성공적으로 소개되어 왔다. 이는 고정식 수복물을 위한 금속 구조물의 임상적 대안으로 제시되었다. 지르코니아 수복물의 가장 흔한 합병증은 상부 도재의 파절이다. 다른 옵션은 고도로 반투명한 지르코니아를 전부지르코니아 고정식 수복물로 사용하는 것이다. 본 논문에서는 전부지르코니아 수복물의 장점, 지르코니아 수복물의 임상적용, 지대치 삭제, 대합치 마모, 지르코니아와 레진시멘트와의 접착, 그리고 기공소와의 의사소통에 관하여 보고하였다.
purpose: This study was to evaluate the shear bond strength of Lithium Disilicate Glass-Ceramic by removable method of temporary cement on the abutment tooth. Material and Method: Sixty molar teeth of human with the occlusal surface up were mounted in acrylic resin blocks. The 45 specimens were prepared to exposure dentin by diamond bur and the eugenol-containing temporary cement($Cavitec^{TM}$ ($KERR^{(R)}$, U.S.A)was applied to the dentin surfaces. After initial removal of the cement with a dental explorer, the specimens were divided into 4 groups of 15 specimens each. The dentin surfaces of the specimens were treated by rotary instrument with as follow pastes: $Zircate^{(R)}$ prophy paste(Dentsply, U.S.A), Radent Prophy Paste(Pascal company,inc. U.S.A), and Dental pumice(Wip mix corporation,U.S.A). An adhesive resin luting agent(Variolink $II^{(R)}$, Ivoclar Vivadent, Leichtenstein) including Monobond-S and $Excite^{(R)}$ was applied to all specimens. The ceramic specimens were made with an A1 ingot of IPS Empress $II^{(R)}$ (Ivoclar Vivadent, Leichtenstein). After the specimens were stored in distilled water for 48hr, the shear bond strength(MPa) was measured by a Universal testing machine(Zwick 145641, Zwick, Germany) at a 1mm/min cross-head speed. The data were statistically analyzed by one-way ANOVA and Duncan's multiple range test. Results: In all group, there were no significant differences in comparison with the control group(p>0.05). The pattern of most failure showed the mixed type of cohesive and adhesive failure. Conclusion: Resin bond strength of IPS Empress $II^{(R)}$ was not affected by removal method of the temporary cement.
Minhyeong Lee;Ilhan Chang;Seok-Jun Kang;Dong-Hyuk Lee;Gye-Chun Cho
Geomechanics and Engineering
/
제33권1호
/
pp.29-40
/
2023
Xanthan gum and starch compound biopolymer (XS), an environmentally friendly soil-binding material produced from natural resources, has been suggested as a slope protection material to enhance soil strength and erosion resistance. Insufficient wet strength and the consequent durability concerns remain, despite XS biopolymer-soil treatment showing high strength and erosion resistance in the dried state, even with a small dosage of soil mass. These concerns need to be solved to improve the field applicability and post-stability of this treatment. This study explored the utilization of an alkaline-based cation crosslinking method using calcium hydroxide and sodium hydroxide to induce non-thermal gelation, resulting in the enhancement of the wet strength and durability of biopolymer-treated soil. Laboratory experiments were conducted to assess the unconfined compressive strength and cyclic wetting-drying durability performance of the treated soil using a selected recipe based on a preliminary gel formation test. The results demonstrated that the uniformity of the gel structure and gelling time varied depending on the ratio of crosslinkers to biopolymer; consequently, the strength of the soil was affected. Subsequently, site soil treated with the recipe, which showed the best performance in indoor assessment, was implemented on the field slope at the bridge abutment via compaction and pressurized spraying methods to assess feasibility in field implementation. Moreover, the variation in surface soil hardness was monitored periodically for one year. Both slopes implemented by the two construction methods showed sufficient stability against detachment and scouring, with a higher soil hardness index than the natural slope for a year.
연구 목적: 임플란트-골 계면에서 발생하는 과도한 열은 골유착을 저해하여 임플란트의 실패를 유발한다. 이에 이번 연구에서는 임플란트 금 합금 보철물의 교합면 삭제시 임플란트-골 계면으로의 열전달 양상과 냉각 방식의 효율성을 알아 보고자 하였다. 연구 재료 및 방법: 온도 감지 장치 제작을 위하여 Internal cone 연결형태의 임플란트에 16개의 K형 열전대를 부착하여 아크릴릭 레진에 포매하였다. 치과용 금 합금과 주조용 abutment를 사용하여 교합면에 3개의 요철을 가지는 시편을 10개 제작하였고, 연결 나사를 이용하여 임플란트와 연결한 뒤 온도 감지 장치를 $37^{\circ}C$ 유지되는 수조에 위치시켰다. 저속 핸드피스와 green stone bur를 이용하여 30초 동안 보철물의 요철을 삭제하였는데, 무냉각군, 공기 냉각 군, 물 분사 냉각 군으로 나누어 요철을 삭제하였다. 보철물이 삭제 되는 동안 임플란트의 부위별로 온도가 0.05초 간격으로 기록되었고, 삭제를 멈춘 뒤에도 무 냉각 군의 경우 임계 온도인 $47^{\circ}C$ 이하로 온도가 하강할 때까지, 공기 냉각군과 물 분사 냉각군의 경우 삭제 중단 후 30초 동안 추가로 온도를 기록하였다. 냉각 방식에 따른 임플란트-골 계면의 온도를 알아보고, 임플란트의 부위별 온도변화의 유의차를 알아보기 위하여 one-way ANOVA를 실시하였고, Turkey HSD 이용하여 95% 유의수준에서 사후 검증하였다. 결과: 무 냉각 군은 임플란트-골 계면의 온도가 $47^{\circ}C$ 이상으로 상승하였으며, 임플란트의 경부에서 유의하게 높은 열이 측정되었다(P>.05). 공기냉각군과물분사냉각군은 임플란트-골 계면의 온도가 $47^{\circ}C$ 이하로 유지되었다. 무 냉각 군에서 임플란트 경부의 온도가 $47^{\circ}C$에 도달되는 데는 약 $10.8{\pm}1.5$초가 소요되었다. 공기 냉각 군과 물 분사 냉각 군 사이에서는 임플란트-골 계면 온도의 유의차가 없었다(P>.05). 결론: 이상의 결과로부터 임플란트 금 합금 보철물의 교합면 삭제 시, 임플란트 주위 조직에 위해를 가할 수 있는 임계 온도 이상의 열이 발생했음을 알 수 있었으며, 냉각 방식은 공기 냉각과 물 분사 냉각 모두 효과적이라고 생각된다.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제34권5호
/
pp.571-577
/
2008
Introduction: Possible etiologic factors associated with bone loss around implants after implantation are surgical trauma, occlusal overload, periimplantitis, presence of micro gap and the formation of biologic distances. Tarnow et al. observed that the crestal bone loss was greater when the distance between the implants was <3mm than when the implants were ${\geq}\;3mm$ apart. The aim of this study was to evaluate the influence of different interimplant distance on marginal bone and crestal bone resorption in the beagle dogs. Materials and methods: The mandibular premolars of 5 dogs were extracted bilaterally. After 12 weeks of healing, each dog received 7 implants. On each side, implants were separated by 2mm (Group 1) and by 5mm (Group 2). After 16 weeks of healing, the dogs were sacrificed. Marginal bone loss was determined through linear measurements made between the implant-abutment junctions and the most coronal portions of the bone in contact with the implant surface. A line was drawn uniting the implant-abutment junctions of the adjacent implants, and a linear measurement was made at the midpoint in the direction of the most coronal peak of the interimplant bone crest to determine the crestal bone loss. Both of them was measured radiologically and histologically. Result and conclusion: In radiological analysis, the mean of marginal bone loss was $1.26{\pm}0.14mm$ for group 1 and $1.23{\pm}0.34mm$ for group 2, the mean of crestal bone loss was $1.10{\pm}0.14mm$ for group 1 and $1.02{\pm}0.30mm$ for group 2. The results were not statistically significant between 2 groups. In histological analysis, the mean of marginal bone loss was $1.63{\pm}0.48mm$ for group 1 and $1.62{\pm}0.50mm$ for group 2, the mean of crestal bone loss was $1.23{\pm}0.35mm$ for group 1 and $1.15{\pm}0.39mm$ for group 2. The differences were also not statistically significant. The clinical significance of this result is that the increase in the crestal bone loss results in the increase in the distance between the base of the interproximal contact of the crowns and the bone crest, and this determines if papilla will be present or absent between implants. Considering this fact, keeping up sufficient interimplant distance is important to minimize crestal bone loss.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.